xref: /freebsd/tests/sys/cddl/zfs/tests/redundancy/redundancy_002_pos.ksh (revision cfd6422a5217410fbd66f7a7a8a64d9d85e61229)
1#!/usr/local/bin/ksh93 -p
2#
3# CDDL HEADER START
4#
5# The contents of this file are subject to the terms of the
6# Common Development and Distribution License (the "License").
7# You may not use this file except in compliance with the License.
8#
9# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
10# or http://www.opensolaris.org/os/licensing.
11# See the License for the specific language governing permissions
12# and limitations under the License.
13#
14# When distributing Covered Code, include this CDDL HEADER in each
15# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
16# If applicable, add the following below this CDDL HEADER, with the
17# fields enclosed by brackets "[]" replaced with your own identifying
18# information: Portions Copyright [yyyy] [name of copyright owner]
19#
20# CDDL HEADER END
21#
22
23# $FreeBSD$
24
25#
26# Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
27# Use is subject to license terms.
28#
29# ident	"@(#)redundancy_002_pos.ksh	1.3	07/05/25 SMI"
30#
31
32. $STF_SUITE/tests/redundancy/redundancy.kshlib
33
34#################################################################################
35#
36# __stc_assertion_start
37#
38# ID: redundancy_002_pos
39#
40# DESCRIPTION:
41#	A raidz2 pool can withstand 2 devices are failing or missing.
42#
43# STRATEGY:
44#	1. Create N(>3,<5) virtual disk files.
45#	2. Create raidz2 pool based on the virtual disk files.
46#	3. Fill the filesystem with directories and files.
47#	4. Record all the files and directories checksum information.
48#	5. Damaged at most two of the virtual disk files.
49#	6. Verify the data is correct to prove raidz2 can withstand 2 devices
50#	   are failing.
51#
52# TESTABILITY: explicit
53#
54# TEST_AUTOMATION_LEVEL: automated
55#
56# CODING_STATUS: COMPLETED (2006-08-21)
57#
58# __stc_assertion_end
59#
60################################################################################
61
62verify_runnable "global"
63
64log_assert "Verify raidz2 pool can withstand two devices are failing."
65log_onexit cleanup
66
67for cnt in 3 4; do
68	setup_test_env $TESTPOOL raidz2 $cnt
69
70	#
71	# Inject data corruption errors for raidz2 pool
72	#
73	for i in 1 2; do
74		damage_devs $TESTPOOL $i "label"
75		log_must is_data_valid $TESTPOOL
76		log_must clear_errors $TESTPOOL
77	done
78
79	#
80	# Inject bad devices errors for raidz2 pool
81	#
82	for i in 1 2; do
83		damage_devs $TESTPOOL $i
84		log_must is_data_valid $TESTPOOL
85		log_must recover_bad_missing_devs $TESTPOOL $i
86	done
87
88	#
89	# Inject missing device errors for raidz2 pool
90	#
91	for i in 1 2; do
92		remove_devs $TESTPOOL $i
93		log_must is_data_valid $TESTPOOL
94		log_must recover_bad_missing_devs $TESTPOOL $i
95	done
96done
97
98log_pass "Raidz2 pool can withstand two devices are failing passed."
99