xref: /freebsd/tests/sys/cddl/zfs/tests/redundancy/redundancy_002_pos.ksh (revision a4e5e0106ac7145f56eb39a691e302cabb4635be)
1#!/usr/local/bin/ksh93 -p
2#
3# CDDL HEADER START
4#
5# The contents of this file are subject to the terms of the
6# Common Development and Distribution License (the "License").
7# You may not use this file except in compliance with the License.
8#
9# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
10# or http://www.opensolaris.org/os/licensing.
11# See the License for the specific language governing permissions
12# and limitations under the License.
13#
14# When distributing Covered Code, include this CDDL HEADER in each
15# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
16# If applicable, add the following below this CDDL HEADER, with the
17# fields enclosed by brackets "[]" replaced with your own identifying
18# information: Portions Copyright [yyyy] [name of copyright owner]
19#
20# CDDL HEADER END
21#
22
23#
24# Copyright 2007 Sun Microsystems, Inc.  All rights reserved.
25# Use is subject to license terms.
26
27. $STF_SUITE/tests/redundancy/redundancy.kshlib
28
29#################################################################################
30#
31# __stc_assertion_start
32#
33# ID: redundancy_002_pos
34#
35# DESCRIPTION:
36#	A raidz2 pool can withstand 2 devices are failing or missing.
37#
38# STRATEGY:
39#	1. Create N(>3,<5) virtual disk files.
40#	2. Create raidz2 pool based on the virtual disk files.
41#	3. Fill the filesystem with directories and files.
42#	4. Record all the files and directories checksum information.
43#	5. Damaged at most two of the virtual disk files.
44#	6. Verify the data is correct to prove raidz2 can withstand 2 devices
45#	   are failing.
46#
47# TESTABILITY: explicit
48#
49# TEST_AUTOMATION_LEVEL: automated
50#
51# CODING_STATUS: COMPLETED (2006-08-21)
52#
53# __stc_assertion_end
54#
55################################################################################
56
57verify_runnable "global"
58
59log_assert "Verify raidz2 pool can withstand two devices are failing."
60log_onexit cleanup
61
62for cnt in 3 4; do
63	setup_test_env $TESTPOOL raidz2 $cnt
64
65	#
66	# Inject data corruption errors for raidz2 pool
67	#
68	for i in 1 2; do
69		damage_devs $TESTPOOL $i "label"
70		log_must is_data_valid $TESTPOOL
71		log_must clear_errors $TESTPOOL
72	done
73
74	#
75	# Inject bad devices errors for raidz2 pool
76	#
77	for i in 1 2; do
78		damage_devs $TESTPOOL $i
79		log_must is_data_valid $TESTPOOL
80		log_must recover_bad_missing_devs $TESTPOOL $i
81	done
82
83	#
84	# Inject missing device errors for raidz2 pool
85	#
86	for i in 1 2; do
87		remove_devs $TESTPOOL $i
88		log_must is_data_valid $TESTPOOL
89		log_must recover_bad_missing_devs $TESTPOOL $i
90	done
91done
92
93log_pass "Raidz2 pool can withstand two devices are failing passed."
94