xref: /freebsd/sys/dev/isci/scil/scic_port.h (revision 924226fba12cc9a228c73b956e1b7fa24c60b055)
1 /*-
2  * SPDX-License-Identifier: BSD-2-Clause OR GPL-2.0
3  *
4  * This file is provided under a dual BSD/GPLv2 license.  When using or
5  * redistributing this file, you may do so under either license.
6  *
7  * GPL LICENSE SUMMARY
8  *
9  * Copyright(c) 2008 - 2011 Intel Corporation. All rights reserved.
10  *
11  * This program is free software; you can redistribute it and/or modify
12  * it under the terms of version 2 of the GNU General Public License as
13  * published by the Free Software Foundation.
14  *
15  * This program is distributed in the hope that it will be useful, but
16  * WITHOUT ANY WARRANTY; without even the implied warranty of
17  * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU
18  * General Public License for more details.
19  *
20  * You should have received a copy of the GNU General Public License
21  * along with this program; if not, write to the Free Software
22  * Foundation, Inc., 51 Franklin St - Fifth Floor, Boston, MA 02110-1301 USA.
23  * The full GNU General Public License is included in this distribution
24  * in the file called LICENSE.GPL.
25  *
26  * BSD LICENSE
27  *
28  * Copyright(c) 2008 - 2011 Intel Corporation. All rights reserved.
29  * All rights reserved.
30  *
31  * Redistribution and use in source and binary forms, with or without
32  * modification, are permitted provided that the following conditions
33  * are met:
34  *
35  *   * Redistributions of source code must retain the above copyright
36  *     notice, this list of conditions and the following disclaimer.
37  *   * Redistributions in binary form must reproduce the above copyright
38  *     notice, this list of conditions and the following disclaimer in
39  *     the documentation and/or other materials provided with the
40  *     distribution.
41  *
42  * THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
43  * "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
44  * LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
45  * A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
46  * OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
47  * SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
48  * LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
49  * DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
50  * THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
51  * (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
52  * OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
53  *
54  * $FreeBSD$
55  */
56 #ifndef _SCIC_PORT_H_
57 #define _SCIC_PORT_H_
58 
59 /**
60  * @file
61  *
62  * @brief This file contains all of the interface methods that can be called
63  *        by an SCI Core user on a SAS or SATA port.
64  */
65 
66 #ifdef __cplusplus
67 extern "C" {
68 #endif // __cplusplus
69 
70 #include <dev/isci/scil/sci_types.h>
71 #include <dev/isci/scil/sci_status.h>
72 #include <dev/isci/scil/intel_sas.h>
73 
74 enum SCIC_PORT_NOT_READY_REASON_CODE
75 {
76    SCIC_PORT_NOT_READY_NO_ACTIVE_PHYS,
77    SCIC_PORT_NOT_READY_HARD_RESET_REQUESTED,
78    SCIC_PORT_NOT_READY_INVALID_PORT_CONFIGURATION,
79    SCIC_PORT_NOT_READY_RECONFIGURING,
80 
81    SCIC_PORT_NOT_READY_REASON_CODE_MAX
82 };
83 
84 /**
85  * @struct SCIC_PORT_END_POINT_PROPERTIES
86  * @brief  This structure defines the properties that can be retrieved
87  *         for each end-point local or remote (attached) port in the
88  *         controller.
89  */
90 typedef struct SCIC_PORT_END_POINT_PROPERTIES
91 {
92    /**
93     * This field indicates the SAS address for the associated end
94     * point in the port.
95     */
96    SCI_SAS_ADDRESS_T  sas_address;
97 
98    /**
99     * This field indicates the protocols supported by the associated
100     * end-point in the port.
101     */
102    SCI_SAS_IDENTIFY_ADDRESS_FRAME_PROTOCOLS_T  protocols;
103 
104 } SCIC_PORT_END_POINT_PROPERTIES_T;
105 
106 /**
107  * @struct SCIC_PORT_PROPERTIES
108  * @brief  This structure defines the properties that can be retrieved
109  *         for each port in the controller.
110  */
111 typedef struct SCIC_PORT_PROPERTIES
112 {
113    /**
114     * This field specifies the logical index of the port (0 relative).
115     */
116    U32  index;
117 
118    /**
119     * This field indicates the local end-point properties for port.
120     */
121    SCIC_PORT_END_POINT_PROPERTIES_T  local;
122 
123    /**
124     * This field indicates the remote (attached) end-point properties
125     * for the port.
126     */
127    SCIC_PORT_END_POINT_PROPERTIES_T  remote;
128 
129    /**
130     * This field specifies the phys contained inside the port.
131     */
132    U32  phy_mask;
133 
134 } SCIC_PORT_PROPERTIES_T;
135 
136 /**
137  * @brief This method simply returns the properties regarding the
138  *        port, such as: physical index, protocols, sas address, etc.
139  *
140  * @param[in]  port this parameter specifies the port for which to retrieve
141  *             the physical index.
142  * @param[out] properties This parameter specifies the properties
143  *             structure into which to copy the requested information.
144  *
145  * @return Indicate if the user specified a valid port.
146  * @retval SCI_SUCCESS This value is returned if the specified port was valid.
147  * @retval SCI_FAILURE_INVALID_PORT This value is returned if the specified port
148  *         is not valid.  When this value is returned, no data is copied to the
149  *         properties output parameter.
150  */
151 SCI_STATUS scic_port_get_properties(
152    SCI_PORT_HANDLE_T        port,
153    SCIC_PORT_PROPERTIES_T * properties
154 );
155 
156 /**
157  * @brief This method will add a phy to an existing port.
158  *
159  * @param[in]  port This parameter specifies the port in which to add a new
160  *             phy.
161  * @param[in]  phy This parameter specifies the phy to be added to the port.
162  *
163  * @return Indicate if the phy was successfully added to the port.
164  * @retval SCI_SUCCESS This value is returned if the phy was successfully
165  *         added to the port.
166  * @retval SCI_FAILURE_INVALID_PORT This value is returned if the supplied
167  *         port is not valid.
168  * @retval SCI_FAILURE_INVALID_PHY This value is returned if the supplied
169  *         phy is either invalid or already contained in another port.
170  */
171 SCI_STATUS scic_port_add_phy(
172    SCI_PORT_HANDLE_T port,
173    SCI_PHY_HANDLE_T  phy
174 );
175 
176 /**
177  * @brief This method will remove a phy from an existing port.
178  *
179  * @param[in]  port This parameter specifies the port in which to remove a
180  *             phy.
181  * @param[in]  phy This parameter specifies the phy to be removed from the
182  *             port.
183  *
184  * @return Indicate if the phy was successfully removed from the port.
185  * @retval SCI_SUCCESS This value is returned if the phy was successfully
186  *         removed from the port.
187  * @retval SCI_FAILURE_INVALID_PORT This value is returned if the supplied
188  *         port is not valid.
189  * @retval SCI_FAILURE_INVALID_PHY This value is returned if the supplied
190  *         phy is either invalid or
191  *         not contained in the port.
192  */
193 SCI_STATUS scic_port_remove_phy(
194    SCI_PORT_HANDLE_T  port,
195    SCI_PHY_HANDLE_T   phy
196 );
197 
198 /**
199  * @brief This method will request the SCI implementation to perform a
200  *        HARD RESET on the SAS Port.  If/When the HARD RESET completes
201  *        the SCI user will be notified via an SCI OS callback indicating
202  *        a direct attached device was found.
203  *
204  * @note The SCI User callback in SCIC_USER_CALLBACKS_T will only be called
205  *       once for each phy in the SAS Port at completion of the hard reset
206  *       sequence.
207  *
208  * @param[in]  port a handle corresponding to the SAS port to be
209  *             hard reset.
210  * @param[in]  reset_timeout This parameter specifies the number of
211  *             milliseconds in which the port reset operation should complete.
212  *
213  * @return Return a status indicating whether the hard reset started
214  *         successfully.
215  * @retval SCI_SUCCESS This value is returned if the hard reset operation
216  *         started successfully.
217  */
218 SCI_STATUS scic_port_hard_reset(
219    SCI_PORT_HANDLE_T port,
220    U32               reset_timeout
221 );
222 
223 /**
224  * @brief This API method enables the broadcast change notification from
225  *        underneath hardware.
226  *
227  * @param[in] port The port upon which broadcast change notifications
228  *            (BCN) are to be enabled.
229  *
230  * @return none
231  */
232 void scic_port_enable_broadcast_change_notification(
233    SCI_PORT_HANDLE_T  port
234 );
235 
236 #ifdef __cplusplus
237 }
238 #endif // __cplusplus
239 
240 #endif // _SCIC_PORT_H_
241 
242