xref: /freebsd/sys/contrib/device-tree/Bindings/pci/brcm,iproc-pcie.txt (revision 5ca8e32633c4ffbbcd6762e5888b6a4ba0708c6c)
1* Broadcom iProc PCIe controller with the platform bus interface
2
3Required properties:
4- compatible:
5      "brcm,iproc-pcie" for the first generation of PAXB based controller,
6used in SoCs including NSP, Cygnus, NS2, and Pegasus
7      "brcm,iproc-pcie-paxb-v2" for the second generation of PAXB-based
8controllers, used in Stingray
9      "brcm,iproc-pcie-paxc" for the first generation of PAXC based
10controller, used in NS2
11      "brcm,iproc-pcie-paxc-v2" for the second generation of PAXC based
12controller, used in Stingray
13  PAXB-based root complex is used for external endpoint devices. PAXC-based
14root complex is connected to emulated endpoint devices internal to the ASIC
15- reg: base address and length of the PCIe controller I/O register space
16- #interrupt-cells: set to <1>
17- interrupt-map-mask and interrupt-map, standard PCI properties to define the
18  mapping of the PCIe interface to interrupt numbers
19- linux,pci-domain: PCI domain ID. Should be unique for each host controller
20- bus-range: PCI bus numbers covered
21- #address-cells: set to <3>
22- #size-cells: set to <2>
23- device_type: set to "pci"
24- ranges: ranges for the PCI memory and I/O regions
25
26Optional properties:
27- phys: phandle of the PCIe PHY device
28- phy-names: must be "pcie-phy"
29- dma-coherent: present if DMA operations are coherent
30- dma-ranges: Some PAXB-based root complexes do not have inbound mapping done
31  by the ASIC after power on reset.  In this case, SW is required to configure
32the mapping, based on inbound memory regions specified by this property.
33
34- brcm,pcie-ob: Some iProc SoCs do not have the outbound address mapping done
35by the ASIC after power on reset. In this case, SW needs to configure it
36
37If the brcm,pcie-ob property is present, the following properties become
38effective:
39
40Required:
41- brcm,pcie-ob-axi-offset: The offset from the AXI address to the internal
42address used by the iProc PCIe core (not the PCIe address)
43
44MSI support (optional):
45
46For older platforms without MSI integrated in the GIC, iProc PCIe core provides
47an event queue based MSI support.  The iProc MSI uses host memories to store
48MSI posted writes in the event queues
49
50On newer iProc platforms, gicv2m or gicv3-its based MSI support should be used
51
52- msi-map: Maps a Requester ID to an MSI controller and associated MSI
53sideband data
54
55- msi-parent: Link to the device node of the MSI controller, used when no MSI
56sideband data is passed between the iProc PCIe controller and the MSI
57controller
58
59Refer to the following binding documents for more detailed description on
60the use of 'msi-map' and 'msi-parent':
61  Documentation/devicetree/bindings/pci/pci-msi.txt
62  Documentation/devicetree/bindings/interrupt-controller/msi.txt
63
64When the iProc event queue based MSI is used, one needs to define the
65following properties in the MSI device node:
66- compatible: Must be "brcm,iproc-msi"
67- msi-controller: claims itself as an MSI controller
68- interrupts: List of interrupt IDs from its parent interrupt device
69
70Optional properties:
71- brcm,pcie-msi-inten: Needs to be present for some older iProc platforms that
72require the interrupt enable registers to be set explicitly to enable MSI
73
74Example:
75	pcie0: pcie@18012000 {
76		compatible = "brcm,iproc-pcie";
77		reg = <0x18012000 0x1000>;
78
79		#interrupt-cells = <1>;
80		interrupt-map-mask = <0 0 0 0>;
81		interrupt-map = <0 0 0 0 &gic GIC_SPI 100 IRQ_TYPE_NONE>;
82
83		linux,pci-domain = <0>;
84
85		bus-range = <0x00 0xff>;
86
87		#address-cells = <3>;
88		#size-cells = <2>;
89		device_type = "pci";
90		ranges = <0x81000000 0 0	  0x28000000 0 0x00010000
91			  0x82000000 0 0x20000000 0x20000000 0 0x04000000>;
92
93		phys = <&phy 0 5>;
94		phy-names = "pcie-phy";
95
96		brcm,pcie-ob;
97		brcm,pcie-ob-axi-offset = <0x00000000>;
98
99		msi-parent = <&msi0>;
100
101		/* iProc event queue based MSI */
102		msi0: msi@18012000 {
103			compatible = "brcm,iproc-msi";
104			msi-controller;
105			interrupt-parent = <&gic>;
106			interrupts = <GIC_SPI 96 IRQ_TYPE_NONE>,
107				     <GIC_SPI 97 IRQ_TYPE_NONE>,
108				     <GIC_SPI 98 IRQ_TYPE_NONE>,
109				     <GIC_SPI 99 IRQ_TYPE_NONE>,
110		};
111	};
112
113	pcie1: pcie@18013000 {
114		compatible = "brcm,iproc-pcie";
115		reg = <0x18013000 0x1000>;
116
117		#interrupt-cells = <1>;
118		interrupt-map-mask = <0 0 0 0>;
119		interrupt-map = <0 0 0 0 &gic GIC_SPI 106 IRQ_TYPE_NONE>;
120
121		linux,pci-domain = <1>;
122
123		bus-range = <0x00 0xff>;
124
125		#address-cells = <3>;
126		#size-cells = <2>;
127		device_type = "pci";
128		ranges = <0x81000000 0 0	  0x48000000 0 0x00010000
129			  0x82000000 0 0x40000000 0x40000000 0 0x04000000>;
130
131		phys = <&phy 1 6>;
132		phy-names = "pcie-phy";
133	};