xref: /freebsd/sys/contrib/device-tree/Bindings/iio/temperature/mlx90632.txt (revision 2e3507c25e42292b45a5482e116d278f5515d04d)
1* Melexis MLX90632 contactless Infra Red temperature sensor
2
3Link to datasheet: https://www.melexis.com/en/documents/documentation/datasheets/datasheet-mlx90632
4
5There are various applications for the Infra Red contactless temperature sensor
6and MLX90632 is most suitable for consumer applications where measured object
7temperature is in range between -20 to 200 degrees Celsius with relative error
8of measurement below 1 degree Celsius in object temperature range for
9industrial applications. Since it can operate and measure ambient temperature
10in range of -20 to 85 degrees Celsius it is suitable also for outdoor use.
11
12Be aware that electronics surrounding the sensor can increase ambient
13temperature. MLX90632 can be calibrated to reduce the housing effect via
14already existing EEPROM parameters.
15
16Since measured object emissivity effects Infra Red energy emitted, emissivity
17should be set before requesting the object temperature.
18
19Required properties:
20  - compatible: should be "melexis,mlx90632"
21  - reg: the I2C address of the sensor (default 0x3a)
22
23Example:
24
25mlx90632@3a {
26	compatible = "melexis,mlx90632";
27	reg = <0x3a>;
28};