xref: /freebsd/lib/geom/raid/graid.8 (revision 95ee2897e98f5d444f26ed2334cc7c439f9c16c6)
1.\" Copyright (c) 2010 Alexander Motin <mav@FreeBSD.org>
2.\" All rights reserved.
3.\"
4.\" Redistribution and use in source and binary forms, with or without
5.\" modification, are permitted provided that the following conditions
6.\" are met:
7.\" 1. Redistributions of source code must retain the above copyright
8.\"    notice, this list of conditions and the following disclaimer.
9.\" 2. Redistributions in binary form must reproduce the above copyright
10.\"    notice, this list of conditions and the following disclaimer in the
11.\"    documentation and/or other materials provided with the distribution.
12.\"
13.\" THIS SOFTWARE IS PROVIDED BY THE AUTHORS AND CONTRIBUTORS ``AS IS'' AND
14.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
15.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
16.\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHORS OR CONTRIBUTORS BE LIABLE
17.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
18.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
19.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
20.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
21.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
22.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
23.\" SUCH DAMAGE.
24.\"
25.\" $FreeBSD$
26.\"
27.Dd April 4, 2013
28.Dt GRAID 8
29.Os
30.Sh NAME
31.Nm graid
32.Nd "control utility for software RAID devices"
33.Sh SYNOPSIS
34.Nm
35.Cm label
36.Op Fl f
37.Op Fl o Ar fmtopt
38.Op Fl S Ar size
39.Op Fl s Ar strip
40.Ar format
41.Ar label
42.Ar level
43.Ar prov ...
44.Nm
45.Cm add
46.Op Fl f
47.Op Fl S Ar size
48.Op Fl s Ar strip
49.Ar name
50.Ar label
51.Ar level
52.Nm
53.Cm delete
54.Op Fl f
55.Ar name
56.Op Ar label | Ar num
57.Nm
58.Cm insert
59.Ar name
60.Ar prov ...
61.Nm
62.Cm remove
63.Ar name
64.Ar prov ...
65.Nm
66.Cm fail
67.Ar name
68.Ar prov ...
69.Nm
70.Cm stop
71.Op Fl fv
72.Ar name ...
73.Nm
74.Cm list
75.Nm
76.Cm status
77.Nm
78.Cm load
79.Nm
80.Cm unload
81.Sh DESCRIPTION
82The
83.Nm
84utility is used to manage software RAID configurations, supported by the
85GEOM RAID class.
86GEOM RAID class uses on-disk metadata to provide access to software-RAID
87volumes defined by different RAID BIOSes.
88Depending on RAID BIOS type and its metadata format, different subsets of
89configurations and features are supported.
90To allow booting from RAID volume, the metadata format should match the
91RAID BIOS type and its capabilities.
92To guarantee that these match, it is recommended to create volumes via the
93RAID BIOS interface, while experienced users are free to do it using this
94utility.
95.Pp
96The first argument to
97.Nm
98indicates an action to be performed:
99.Bl -tag -width ".Cm destroy"
100.It Cm label
101Create an array with single volume.
102The
103.Ar format
104argument specifies the on-disk metadata format to use for this array,
105such as "Intel".
106The
107.Ar label
108argument specifies the label of the created volume.
109The
110.Ar level
111argument specifies the RAID level of the created volume, such as:
112"RAID0", "RAID1", etc.
113The subsequent list enumerates providers to use as array components.
114The special name "NONE" can be used to reserve space for absent disks.
115The order of components can be important, depending on specific RAID level
116and metadata format.
117.Pp
118Additional options include:
119.Bl -tag -width ".Fl s Ar strip"
120.It Fl f
121Enforce specified configuration creation if it is officially unsupported,
122but technically can be created.
123.It Fl o Ar fmtopt
124Specifies metadata format options.
125.It Fl S Ar size
126Use
127.Ar size
128bytes on each component for this volume.
129Should be used if several volumes per array are planned, or if smaller
130components going to be inserted later.
131Defaults to size of the smallest component.
132.It Fl s Ar strip
133Specifies strip size in bytes.
134Defaults to 131072.
135.El
136.It Cm add
137Create another volume on the existing array.
138The
139.Ar name
140argument is the name of the existing array, reported by label command.
141The rest of arguments are the same as for the label command.
142.It Cm delete
143Delete volume(s) from the existing array.
144When the last volume is deleted, the array is also deleted and its metadata
145erased.
146The
147.Ar name
148argument is the name of existing array.
149Optional
150.Ar label
151or
152.Ar num
153arguments allow specifying volume for deletion.
154.Pp
155Additional options include:
156.Bl -tag -width ".Fl f"
157.It Fl f
158Delete volume(s) even if it is still open.
159.El
160.It Cm insert
161Insert specified provider(s) into specified array instead of the first missing
162or failed components.
163If there are no such components, mark disk(s) as spare.
164.It Cm remove
165Remove the specified provider(s) from the specified array and erase metadata.
166If there are spare disks present, the removed disk(s) will be replaced by
167spares.
168.It Cm fail
169Mark the given disks(s) as failed, removing from active use unless absolutely
170necessary due to exhausted redundancy.
171If there are spare disks present - failed disk(s) will be replaced with one
172of them.
173.It Cm stop
174Stop the given array.
175The metadata will not be erased.
176.Pp
177Additional options include:
178.Bl -tag -width ".Fl f"
179.It Fl f
180Stop the given array even if some of its volumes are opened.
181.El
182.It Cm list
183See
184.Xr geom 8 .
185.It Cm status
186See
187.Xr geom 8 .
188.It Cm load
189See
190.Xr geom 8 .
191.It Cm unload
192See
193.Xr geom 8 .
194.El
195.Pp
196Additional options include:
197.Bl -tag -width ".Fl v"
198.It Fl v
199Be more verbose.
200.El
201.Sh SUPPORTED METADATA FORMATS
202The GEOM RAID class follows a modular design, allowing different metadata
203formats to be used.
204Support is currently implemented for the following formats:
205.Bl -tag -width "Intel"
206.It DDF
207The format defined by the SNIA Common RAID Disk Data Format v2.0 specification.
208Used by some Adaptec RAID BIOSes and some hardware RAID controllers.
209Because of high format flexibility different implementations support
210different set of features and have different on-disk metadata layouts.
211To provide compatibility, the GEOM RAID class mimics capabilities
212of the first detected DDF array.
213Respecting that, it may support different number of disks per volume,
214volumes per array, partitions per disk, etc.
215The following configurations are supported: RAID0 (2+ disks), RAID1 (2+ disks),
216RAID1E (3+ disks), RAID3 (3+ disks), RAID4 (3+ disks), RAID5 (3+ disks),
217RAID5E (4+ disks), RAID5EE (4+ disks), RAID5R (3+ disks), RAID6 (4+ disks),
218RAIDMDF (4+ disks), RAID10 (4+ disks), SINGLE (1 disk), CONCAT (2+ disks).
219.Pp
220Format supports two options "BE" and "LE", that mean big-endian byte order
221defined by specification (default) and little-endian used by some Adaptec
222controllers.
223.It Intel
224The format used by Intel RAID BIOS.
225Supports up to two volumes per array.
226Supports configurations: RAID0 (2+ disks), RAID1 (2 disks),
227RAID5 (3+ disks), RAID10 (4 disks).
228Configurations not supported by Intel RAID BIOS, but enforceable on your own
229risk: RAID1 (3+ disks), RAID1E (3+ disks), RAID10 (6+ disks).
230.It JMicron
231The format used by JMicron RAID BIOS.
232Supports one volume per array.
233Supports configurations: RAID0 (2+ disks), RAID1 (2 disks),
234RAID10 (4 disks), CONCAT (2+ disks).
235Configurations not supported by JMicron RAID BIOS, but enforceable on your own
236risk: RAID1 (3+ disks), RAID1E (3+ disks), RAID10 (6+ disks), RAID5 (3+ disks).
237.It NVIDIA
238The format used by NVIDIA MediaShield RAID BIOS.
239Supports one volume per array.
240Supports configurations: RAID0 (2+ disks), RAID1 (2 disks),
241RAID5 (3+ disks), RAID10 (4+ disks), SINGLE (1 disk), CONCAT (2+ disks).
242Configurations not supported by NVIDIA MediaShield RAID BIOS, but enforceable
243on your own risk: RAID1 (3+ disks).
244.It Promise
245The format used by Promise and AMD/ATI RAID BIOSes.
246Supports multiple volumes per array.
247Each disk can be split to be used by up to two arbitrary volumes.
248Supports configurations: RAID0 (2+ disks), RAID1 (2 disks),
249RAID5 (3+ disks), RAID10 (4 disks), SINGLE (1 disk), CONCAT (2+ disks).
250Configurations not supported by RAID BIOSes, but enforceable on your
251own risk: RAID1 (3+ disks), RAID10 (6+ disks).
252.It SiI
253The format used by SiliconImage RAID BIOS.
254Supports one volume per array.
255Supports configurations: RAID0 (2+ disks), RAID1 (2 disks),
256RAID5 (3+ disks), RAID10 (4 disks), SINGLE (1 disk), CONCAT (2+ disks).
257Configurations not supported by SiliconImage RAID BIOS, but enforceable on your
258own risk: RAID1 (3+ disks), RAID10 (6+ disks).
259.El
260.Sh SUPPORTED RAID LEVELS
261The GEOM RAID class follows a modular design, allowing different RAID levels
262to be used.
263Full support for the following RAID levels is currently implemented:
264RAID0, RAID1, RAID1E, RAID10, SINGLE, CONCAT.
265The following RAID levels supported as read-only for volumes in optimal
266state (without using redundancy): RAID4, RAID5, RAID5E, RAID5EE, RAID5R,
267RAID6, RAIDMDF.
268.Sh RAID LEVEL MIGRATION
269The GEOM RAID class has no support for RAID level migration, allowed by some
270metadata formats.
271If you started migration using BIOS or in some other way, make sure to
272complete it there.
273Do not run GEOM RAID class on migrating volumes under pain of possible data
274corruption!
275.Sh 2TiB BARRIERS
276NVIDIA metadata format does not support volumes above 2TiB.
277.Sh SYSCTL VARIABLES
278The following
279.Xr sysctl 8
280variable can be used to control the behavior of the
281.Nm RAID
282GEOM class.
283.Bl -tag -width indent
284.It Va kern.geom.raid.aggressive_spare : No 0
285Use any disks without metadata connected to controllers of the vendor
286matching to volume metadata format as spare.
287Use it with much care to not lose data if connecting unrelated disk!
288.It Va kern.geom.raid.clean_time : No 5
289Mark volume as clean when idle for the specified number of seconds.
290.It Va kern.geom.raid.debug : No 0
291Debug level of the
292.Nm RAID
293GEOM class.
294.It Va kern.geom.raid.enable : No 1
295Enable on-disk metadata taste.
296.It Va kern.geom.raid.idle_threshold : No 1000000
297Time in microseconds to consider a volume idle for rebuild purposes.
298.It Va kern.geom.raid.name_format : No 0
299Providers name format: 0 -- raid/r{num}, 1 -- raid/{label}.
300.It Va kern.geom.raid.read_err_thresh : No 10
301Number of read errors equated to disk failure.
302Write errors are always considered as disk failures.
303.It Va kern.geom.raid.start_timeout : No 30
304Time to wait for missing array components on startup.
305.It Va kern.geom.raid. Ns Ar X Ns Va .enable : No 1
306Enable taste for specific metadata or transformation module.
307.El
308.Sh EXIT STATUS
309Exit status is 0 on success, and non-zero if the command fails.
310.Sh SEE ALSO
311.Xr geom 4 ,
312.Xr geom 8 ,
313.Xr gvinum 8
314.Sh HISTORY
315The
316.Nm
317utility appeared in
318.Fx 9.0 .
319.Sh AUTHORS
320.An Alexander Motin Aq Mt mav@FreeBSD.org
321.An M. Warner Losh Aq Mt imp@FreeBSD.org
322