-N show IS3 or IS4 general information.
-w show IS3 port xmit wait counters.
-i show IS4 counter group info.
-c <num,num> configure IS4 counter groups. Configure IS4 counter groups 0 and 1. Such configuration is not persistent across IS4 reboot. First number is for counter group 0 and second is for counter group 1. Group 0 counter config values: NINDENT NDENT 0.0
:: NDENT 7.0 NDENT 3.5 0 - PortXmitDataSL0-7 1 - PortXmitDataSL8-15 2 - PortRcvDataSL0-7 NINDENT NINDENT Group 1 counter config values: NINDENT NDENT 0.0
:: 1 - PortXmitDataSL8-15 2 - PortRcvDataSL0-7 8 - PortRcvDataSL8-15
-R, --Read <addr,mask> Read configuration space record at addr
-W, --Write <addr,val,mask> Write configuration space record at addr
--dgid <gid> destination GID: use when GRH is required in packets (IPv6 format) NINDENT
. -G, --Guid The address specified is a Port GUID Define the common option -L
. -L, --Lid The address specified is a LID Define the common option -s
. -s, --sm_port <smlid> use \(aqsmlid\(aq as the target lid for SA queries.
. -C, --Ca <ca_name> use the specified ca_name. Define the common option -P
. -P, --Port <ca_port> use the specified ca_port. Explanation of local port selection
.
ibaddr # use the first port (criteria #1 above) ibaddr -C mthca1 # pick the best port from "mthca1" only. ibaddr -P 2 # use the second (active/up) port from the first available IB device. ibaddr -C mthca0 -P 2 # use the specified port only.NINDENT NINDENT NINDENT NINDENT
. NDENT 0.0
-d raise the IB debugging level.
May be used several times (-ddd or -d -d -d).
NINDENT Define the common option -e
.
NDENT 0.0
-e show send and receive errors (timeouts and others)
NINDENT Define the common option -h
.
-h, --help show the usage message
Define the common option -v
.
NDENT 0.0
-v, --verbose increase the application verbosity level.
May be used several times (-vv or -v -v -v)
NINDENT Define the common option -V
.
-V, --version show the version info.
. -t, --timeout <timeout_ms> override the default timeout for the solicited mads. Define the common option -z
. --config, -z <config_file> Specify alternate config file. NDENT 0.0 NDENT 3.5 Default: /etc/infiniband-diags/ibdiag.conf NINDENT NINDENT
.
:: vendstat -N 6 # read IS3 or IS4 general information vendstat -w 6 # read IS3 port xmit wait counters vendstat -i 6 12 # read IS4 port 12 counter group info vendstat -c 0,1 6 12 # configure IS4 port 12 counter groups for PortXmitDataSL vendstat -c 2,8 6 12 # configure IS4 port 12 counter groups for PortRcvDataSL NINDENT
Hal Rosenstock < \%hal.rosenstock@gmail.com >