Man page generated from reStructuredText.
.
. RS \\$1 . nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin] . nr rst2man-indent-level +1 .rstReportMargin post:
.. . RE indent \\n[an-margin]
old: \\n[rst2man-indent\\n[rst2man-indent-level]]
.nr rst2man-indent-level -1 new: \\n[rst2man-indent\\n[rst2man-indent-level]]
..
. -L, --Lid The address specified is a LID Define the common option -G
. -G, --Guid The address specified is a Port GUID Define the common option -s
. -s, --sm_port <smlid> use \(aqsmlid\(aq as the target lid for SA queries.
. -C, --Ca <ca_name> use the specified ca_name. Define the common option -P
. -P, --Port <ca_port> use the specified ca_port. Explanation of local port selection
.
. --config, -z <config_file> Specify alternate config file. NDENT 0.0 NDENT 3.5 Default: /etc/infiniband-diags/ibdiag.conf NINDENT NINDENT Define the common option -t
. -t, --timeout <timeout_ms> override the default timeout for the solicited mads.
. -h, --help show the usage message Define the common option -d
. NDENT 0.0
.
.
IBPING 8 "" "" "Open IB Diagnostics"
NAME
IBPING - ping an InfiniBand address
.
.nr rst2man-indent-level 0
.
\\$1 \\n[an-margin]
level \\n[rst2man-indent-level]
level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
-
\\n[rst2man-indent0]
\\n[rst2man-indent1]
\\n[rst2man-indent2]
..
.rstReportMargin pre:. RS \\$1 . nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin] . nr rst2man-indent-level +1 .rstReportMargin post:
.. . RE indent \\n[an-margin]
old: \\n[rst2man-indent\\n[rst2man-indent-level]]
.nr rst2man-indent-level -1 new: \\n[rst2man-indent\\n[rst2man-indent-level]]
..
SYNOPSIS
ibping [options] <dest lid | guid>
DESCRIPTION
ibping uses vendor mads to validate connectivity between IB nodes.
On exit, (IP) ping like output is show. ibping is run as client/server.
Default is to run as client. Note also that a default ping server is
implemented within the kernel.
OPTIONS
-c, --count
stop after count packets
-f, --flood
flood destination: send packets back to back without delay
-o, --oui
use specified OUI number to multiplex vendor mads
-S, --Server
start in server mode (do not return)
--dgid <gid>
destination GID: use when GRH is required in packets (IPv6 format)
Addressing Flags
Define the common option -L. -L, --Lid The address specified is a LID Define the common option -G
. -G, --Guid The address specified is a Port GUID Define the common option -s
. -s, --sm_port <smlid> use \(aqsmlid\(aq as the target lid for SA queries.
Port Selection flags
Define the common option -C. -C, --Ca <ca_name> use the specified ca_name. Define the common option -P
. -P, --Port <ca_port> use the specified ca_port. Explanation of local port selection
.
Local port Selection
Multiple port/Multiple CA support: when no IB device or port is specified
(see the "local umad parameters" below), the libibumad library
selects the port to use by the following criteria:
NDENT 0.0 NDENT 3.5 NDENT 0.0 1. 3
the first port that is ACTIVE.
2. 3
if not found, the first port that is UP (physical link up).
NINDENT If a port and/or CA name is specified, the libibumad library attempts
to fulfill the user request, and will fail if it is not possible.
For example:
NDENT 0.0 NDENT 3.5 ibaddr # use the first port (criteria #1 above) ibaddr -C mthca1 # pick the best port from "mthca1" only. ibaddr -P 2 # use the second (active/up) port from the first available IB device. ibaddr -C mthca0 -P 2 # use the specified port only.NINDENT NINDENT NINDENT NINDENT
Configuration flags
Define the common option -z. --config, -z <config_file> Specify alternate config file. NDENT 0.0 NDENT 3.5 Default: /etc/infiniband-diags/ibdiag.conf NINDENT NINDENT Define the common option -t
. -t, --timeout <timeout_ms> override the default timeout for the solicited mads.
Debugging flags
Define the common option -h. -h, --help show the usage message Define the common option -d
. NDENT 0.0
-d raise the IB debugging level.
May be used several times (-ddd or -d -d -d).
NINDENT Define the common option -e
.
NDENT 0.0
-e show send and receive errors (timeouts and others)
NINDENT Define the common option -v
.
NDENT 0.0
-v, --verbose increase the application verbosity level.
May be used several times (-vv or -v -v -v)
NINDENT Define the common option -V
.
-V, --version show the version info.
FILES
Common text for the config file.
CONFIG FILE
/etc/infiniband-diags/ibdiag.conf
A global config file is provided to set some of the common options for all
tools. See supplied config file for details.
AUTHOR
NDENT 0.0
Hal Rosenstock < \%halr@voltaire.com >
NINDENT Generated by docutils manpage writer.
.