xref: /freebsd/contrib/ntp/html/drivers/tf582_4.html (revision 416ba5c74546f32a993436a99516d35008e9f384)
1ea906c41SOllivier Robert<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
2ea906c41SOllivier Robert
3ea906c41SOllivier Robert<html>
4ea906c41SOllivier Robert
5ea906c41SOllivier Robert	<head>
6ea906c41SOllivier Robert		<meta name="GENERATOR" content="Adobe PageMill 3.0 per Windows">
7ea906c41SOllivier Robert		<meta http-equiv="Content-Type" content="text/html;charset=iso-8859-1">
8ea906c41SOllivier Robert		<title>PTB Modem Time Service</title>
9ea906c41SOllivier Robert		<link href="scripts/style.css" type="text/css" rel="stylesheet">
10ea906c41SOllivier Robert	</head>
11ea906c41SOllivier Robert
12ea906c41SOllivier Robert	<body>
13ea906c41SOllivier Robert		<h3>European Automated Computer Time Services</h3>
14*2b15cb3dSCy Schubert<p>Last update:
15*2b15cb3dSCy Schubert  <!-- #BeginDate format:En2m -->21-Oct-2010  23:44<!-- #EndDate -->
16*2b15cb3dSCy Schubert  UTC</p>
17ea906c41SOllivier Robert		<hr>
18ea906c41SOllivier Robert		<p>Several European countries use the following message data format:</p>
19ea906c41SOllivier Robert		<p><font size="-1" face="Courier New">Data format<br>
20ea906c41SOllivier Robert				0000000000111111111122222222223333333333444444444455555555556666666666777777777 7<br>
21ea906c41SOllivier Robert				0123456789012345678901234567890123456789012345678901234567890123456789012345678 9<br>
22ea906c41SOllivier Robert				1995-01-23 20:58:51 MEZ 10402303260219950123195849740+40000500 *<br>
23ea906c41SOllivier Robert				A B C D EF G H IJ K L M N O P Q R S T U V W XY Z&lt;CR&gt;&lt;LF&gt;<br>
24ea906c41SOllivier Robert				A year<br>
25ea906c41SOllivier Robert				B month<br>
26ea906c41SOllivier Robert				C day<br>
27ea906c41SOllivier Robert				D hour<br>
28ea906c41SOllivier Robert				E : normally<br>
29ea906c41SOllivier Robert				A for DST to ST switch first hour<br>
30ea906c41SOllivier Robert				B for DST to ST switch second hour if not marked in H<br>
31ea906c41SOllivier Robert				F minute<br>
32ea906c41SOllivier Robert				G second<br>
33ea906c41SOllivier Robert				H timezone<br>
34ea906c41SOllivier Robert				I day of week<br>
35ea906c41SOllivier Robert				J week of year<br>
36ea906c41SOllivier Robert				K day of year<br>
37ea906c41SOllivier Robert				L month for next ST/DST changes<br>
38ea906c41SOllivier Robert				M day<br>
39ea906c41SOllivier Robert				N hour<br>
40ea906c41SOllivier Robert				O UTC year<br>
41ea906c41SOllivier Robert				P UTC month<br>
42ea906c41SOllivier Robert				Q UTC day<br>
43ea906c41SOllivier Robert				R UTC hour<br>
44ea906c41SOllivier Robert				S UTC minute<br>
45ea906c41SOllivier Robert				T modified julian day (MJD)<br>
46ea906c41SOllivier Robert				U DUT1<br>
47ea906c41SOllivier Robert				V direction and month if leap second<br>
48ea906c41SOllivier Robert				W signal delay (assumed/measured)<br>
49ea906c41SOllivier Robert				X sequence number for additional text line in Y<br>
50ea906c41SOllivier Robert				Y additional text<br>
51ea906c41SOllivier Robert				Z on time marker (* - assumed delay / # measured delay)<br>
52ea906c41SOllivier Robert				&lt;CR&gt;!&lt;LF&gt; ! is second change !<br>
53ea906c41SOllivier Robert			</font></p>
54ea906c41SOllivier Robert		<p>This format is an ITU-R Recommendation (ITU-R TF583.4) and is now available from the primary timing centres of the following countries: Austria, Belgium, Germany, Italy, The Netherlands, Poland, Portugal, Romania, Spain, Sweden, Switzerland, Turkey and United Kingdom. Some examples are:</p>
55ea906c41SOllivier Robert		<ul>
56ea906c41SOllivier Robert			<li>In Germany by Physikalisch-Technische Bundesanstalt (PTB)'s timecode service. Phone number: +49 5 31 51 20 38.
57ea906c41SOllivier Robert				<p>For more detail, see <a href="http://www.ptb.de/english/org/4/43/433/disse.html">http://www.ptb.de/english/org/4/43/433/disse.htm</a></p>
58ea906c41SOllivier Robert			<li>In the UK by National Physical Laboratory (NPL)'s TRUETIME service. Phone number: 0891 516 333
59ea906c41SOllivier Robert				<p>For more detail, see <a href="http://www.npl.co.uk/npl/ctm/truetime.html">http://www.npl.co.uk/npl/ctm/truetime.html</a></p>
60ea906c41SOllivier Robert			<li>In Italy by Istituto Elettrotecnico Nazionale &quot;Galileo Ferrais&quot; (IEN)'s CTD service. Phone number: 166 11 46 15
61ea906c41SOllivier Robert				<p>For more detail, see <a href="http://www.ien.it/tf/time/Pagina42.html">http://www.ien.it/tf/time/Pagina42.html</a></p>
62ea906c41SOllivier Robert			<li>In Switzerland by Swiss Federal Office of Metrology's timecode service. Phone number: 031 323 32 25
63ea906c41SOllivier Robert				<p>For more detail, see <a href="http://www.metas.ch/en/labors/official-time/modem/index.html">http://www.ofmet.admin.ch/de/labors/4/Zeitvert.html </a></p>
64ea906c41SOllivier Robert			<li>In Sweden by SP Swedish National Testing and Research Institute 's timecode service. Phone number: +46 33 415783.
65ea906c41SOllivier Robert				<p>For more detail, see <a href="http://www.sp.se/metrology/timefreq/eng/tandf.htm">http://www.sp.se/metrology/timefreq/eng/tandf.htm</a></p>
66ea906c41SOllivier Robert		</ul>
67ea906c41SOllivier Robert		<dl></dl>
68ea906c41SOllivier Robert		<h4>Additional Information</h4>
69ea906c41SOllivier Robert		<p><a href="../refclock.html">Reference Clock Drivers</a></p>
70ea906c41SOllivier Robert		<hr>
71ea906c41SOllivier Robert		<script type="text/javascript" language="javascript" src="scripts/footer.txt"></script>
72ea906c41SOllivier Robert	</body>
73ea906c41SOllivier Robert
74ea906c41SOllivier Robert</html>
75