| /linux/Documentation/networking/device_drivers/cellular/qualcomm/ |
| H A D | rmnet.rst | 43 Command (1)/ Data (0) bit value is to indicate if the packet is a MAP command 52 Multiplexer ID is to indicate the PDN on which data has to be sent. 70 Command (1)/ Data (0) bit value is to indicate if the packet is a MAP command 79 Multiplexer ID is to indicate the PDN on which data has to be sent. 124 Command (1)/ Data (0) bit value is to indicate if the packet is a MAP command 128 Next header is used to indicate the presence of another header, currently is 134 Multiplexer ID is to indicate the PDN on which data has to be sent. 149 Header Type is to indicate the type of header, this usually is set to CHECKSUM 159 Checksum Valid is to indicate whether the header checksum is valid. Value of 1
|
| /linux/Documentation/leds/ |
| H A D | well-known-leds.txt | 21 Game controllers may feature LEDs to indicate a player number. This is commonly 23 The "player LEDs" are then programmed with a pattern to indicate a particular 25 to indicate player 1, "-x--" to indicate player 2 etcetera where "x" means on. 101 multiple LEDs, use left/right, or top/bottom to indicate their
|
| /linux/Documentation/ABI/testing/ |
| H A D | sysfs-bus-iio-light-si1133 | 6 dark photodiode. "small" indicate the surface area capturing 14 dark photodiodes. "large" indicate the surface area capturing
|
| H A D | sysfs-devices-mmc | 8 is enabled, this attribute will indicate the start address of 19 is enabled, this attribute will indicate the size of enhanced
|
| H A D | sysfs-class-spi-eeprom | 7 name to indicate that it employs ferroelectric process.
|
| H A D | sysfs-class-firmware | 42 for firmware uploads. Echo 1 onto the loading file to indicate 45 file to indicate that the write is complete. For firmware
|
| H A D | sysfs-platform-intel-pmc | 8 manufacturing process to indicate that consequent reset
|
| H A D | sysfs-platform-dfl-port | 31 It's used to indicate transient AP1 state. Write 1 to this 39 It's used to indicate transient AP2 state. Write 1 to this
|
| H A D | sysfs-firmware-opal-sensor-groups | 9 can also indicate the group of sensors belonging to
|
| /linux/Documentation/trace/ |
| H A D | events-kmem.rst | 25 Heavy activity for these events may indicate that a specific cache is 65 is triggered. Significant amounts of activity here could indicate that the 71 indicate that the system is under memory pressure and can also indicate 97 is being concentrated in one place. It could also indicate that the per-CPU
|
| /linux/Documentation/userspace-api/gpio/ |
| H A D | gpio-v2-line-set-values-ioctl.rst | 30 to indicate the subset of requested lines to set and ``bits`` set to 31 indicate the new value.
|
| H A D | gpio-v2-get-lineinfo-ioctl.rst | 29 ``offset`` field set to indicate the line to be collected.
|
| /linux/Documentation/hwmon/ |
| H A D | occ.rst | 57 Temperature sensor fault boolean; 1 to indicate 58 that a fault is present or 0 to indicate that 64 VRM temperature alarm boolean; 1 to indicate 65 alarm, 0 to indicate no alarm
|
| H A D | sht15.rst | 67 flag to indicate not to reload from OTP (default to false). 69 flag to indicate the temp/humidity resolution to use (default to false).
|
| H A D | adt7410.rst | 53 INT pin to indicate that a minimum or maximum temperature set point has been 54 exceeded, as well as a critical temperature (CT) pin to indicate that the
|
| H A D | scpi-hwmon.rst | 33 The driver relies on device tree node to indicate the presence of SCPI
|
| /linux/Documentation/admin-guide/device-mapper/ |
| H A D | kcopyd.rst | 9 Users of kcopyd must first create a client and indicate how many memory pages 40 passing back the user's context pointer. It will also indicate if a read or
|
| /linux/drivers/net/hyperv/ |
| H A D | netvsc_drv.c | 667 struct rndis_indicate_status *indicate = &resp->msg.indicate_status; in netvsc_linkstatus_callback() local 680 memcpy(indicate, data + RNDIS_HEADER_SIZE, sizeof(*indicate)); in netvsc_linkstatus_callback() 683 if (indicate->status == RNDIS_STATUS_LINK_SPEED_CHANGE) { in netvsc_linkstatus_callback() 692 if (indicate->status_buflen < sizeof(speed) || in netvsc_linkstatus_callback() 693 indicate->status_buf_offset < sizeof(*indicate) || in netvsc_linkstatus_callback() 694 data_buflen - RNDIS_HEADER_SIZE < indicate->status_buf_offset || in netvsc_linkstatus_callback() 695 data_buflen - RNDIS_HEADER_SIZE - indicate->status_buf_offset in netvsc_linkstatus_callback() 696 < indicate->status_buflen) { in netvsc_linkstatus_callback() 701 speed = *(u32 *)(data + RNDIS_HEADER_SIZE + indicate->status_buf_offset) / 10000; in netvsc_linkstatus_callback() 707 if (indicate->status != RNDIS_STATUS_NETWORK_CHANGE && in netvsc_linkstatus_callback() [all …]
|
| /linux/Documentation/devicetree/bindings/sound/ |
| H A D | nvidia,tegra30-ahub.txt | 59 For RX CIFs, the numbers indicate the register number within AHUB routing 61 For TX CIFs, the numbers indicate the bit position within the AHUB routing
|
| /linux/Documentation/arch/arm64/ |
| H A D | elf_hwcaps.rst | 45 The majority of hwcaps are intended to indicate the presence of features 55 Such hwcaps indicate the availability of functionality that the ARM ARM 57 indicate that idreg.field is precisely equal to val, nor do they 58 indicate the absence of functionality implied by other values of 61 Other hwcaps may indicate the presence of features which cannot be
|
| /linux/Documentation/PCI/endpoint/ |
| H A D | pci-ntb-function.rst | 66 (ATU) and to indicate the link status. Endpoint can indicate the status of 67 commands issued by host in this region. Endpoint can also indicate the 131 CMD_LINK_UP (0x3): Command to indicate an NTB application is 134 raise a LINK_UP event to both the hosts to indicate the host
|
| /linux/Documentation/i2c/ |
| H A D | fault-codes.rst | 18 result for an operation ... it doesn't indicate that anything is wrong 93 Returned by I2C adapters to indicate that the address phase 98 Returned by driver probe() methods to indicate that they
|
| /linux/Documentation/devicetree/bindings/powerpc/opal/ |
| H A D | sensor-groups.txt | 13 - type : String to indicate the type of sensor-group
|
| /linux/Documentation/networking/ |
| H A D | secid.rst | 9 The secid member in the flow structure is used in LSMs (e.g. SELinux) to indicate
|
| /linux/Documentation/driver-api/usb/ |
| H A D | error-codes.rst | 132 to indicate timeout expired before the transfer 181 indicate hardware problems such as bad devices (including firmware) 187 controller use to indicate a transfer has failed because of device
|