| /linux/Documentation/hwmon/ |
| H A D | ina209.rst | 48 in0_max_alarm shunt voltage max alarm limit exceeded 49 in0_min_alarm shunt voltage min alarm limit exceeded 50 in0_crit_max_alarm shunt voltage crit max alarm limit exceeded 51 in0_crit_min_alarm shunt voltage crit min alarm limit exceeded 61 in1_max_alarm bus voltage max alarm limit exceeded 62 in1_min_alarm bus voltage min alarm limit exceeded 63 in1_crit_max_alarm bus voltage crit max alarm limit exceeded 64 in1_crit_min_alarm bus voltage crit min alarm limit exceeded 71 power1_max_alarm power max alarm limit exceeded 72 power1_crit_alarm power crit alarm limit exceeded
|
| H A D | adm9240.rst | 187 0 +2.5 V_Error high or low limit exceeded 188 1 VCCP_Error high or low limit exceeded 189 2 +3.3 V_Error high or low limit exceeded 190 3 +5 V_Error high or low limit exceeded 192 6 FAN1_Error fan low limit exceeded 193 7 FAN2_Error fan low limit exceeded 194 8 +12 V_Error high or low limit exceeded 195 9 VCCP2_Error high or low limit exceeded
|
| H A D | max31760.rst | 33 OT threshold is exceeded, the SHDN pin is asserted low and can be used to 35 remote high-temperature threshold has been exceeded. 67 temp[1-2]_max Temperature max value. Asserts "ALERT" pin when exceeded 69 temp[1-2]_crit Temperature critical value. Asserts "SHDN" pin when exceeded
|
| H A D | ina3221.rst | 38 curr[123]_crit_alarm Critical alert current limit exceeded 42 curr[123]_max_alarm Warning alert current limit exceeded 54 curr4_crit_alarm Critical alert current limit exceeded for sum of
|
| H A D | adm1026.rst | 51 limit. If the limit is exceeded, an interrupt (#SMBALERT) can be 53 limits for each sensor. If this limit is exceeded, the #THERM output will 59 corresponds to a minimum fan speed. If the limit is exceeded, an interrupt
|
| H A D | adt7410.rst | 54 exceeded, as well as a critical temperature (CT) pin to indicate that the 55 critical temperature set point has been exceeded. Both pins can be set up with a
|
| H A D | xgene-hwmon.rst | 32 - An 1 would indicates on-die temperature exceeded threshold
|
| H A D | acbel-fsg032.rst | 70 power2_crit_alarm Output power crit alarm limit exceeded.
|
| H A D | lm85.rst | 194 that can be used to signal the chipset in case a limit is exceeded or the
|
| /linux/Documentation/filesystems/ |
| H A D | quota.rst | 46 - type of quota being exceeded (one of USRQUOTA, GRPQUOTA) 49 is being exceeded. 53 - what kind of limit is exceeded: 58 inode softlimit is exceeded longer 65 space (block) softlimit is exceeded
|
| H A D | ext2.rst | 229 count has been exceeded or if the maximum time between checks has been 230 exceeded.
|
| /linux/tools/perf/Documentation/ |
| H A D | intel-acr.txt | 13 period is exceeded. 23 taken. If "cycles" is exceeded first, both counters in the group will be 27 events in the group to be reset when the period is exceeded. In the 31 that both event counters will be reset if the sample period is exceeded
|
| H A D | perf-stat.txt | 374 compute whether a metric has exceeded its threshold expression. This 429 color red is used to signify a metric has exceeded a threshold
|
| /linux/Documentation/ABI/testing/ |
| H A D | sysfs-class-led-flash | 60 has exceeded the limit specific to the flash controller 61 * flash-timeout-exceeded 73 supply has exceeded the limit specific to the flash 88 the temperature of the LED has exceeded
|
| /linux/Documentation/networking/devlink/ |
| H A D | prestera.rst | 57 - Traps (exception) packets that exceeded port's MTU 63 - Traps (exception) IPv4 packets whose TTL exceeded 141 …g packets (dropped by Ingress policer, metering drop), e.g. packet rate exceeded configured bandwi…
|
| /linux/Documentation/userspace-api/media/v4l/ |
| H A D | ext-ctrls-flash.rst | 153 - Flash controller voltage to the flash LED has exceeded the limit 165 - Current in the LED power supply has exceeded the limit specific to 178 - The temperature of the LED has exceeded its allowed upper limit.
|
| /linux/Documentation/scheduler/ |
| H A D | sched-eevdf.rst | 18 has exceeded its portion. EEVDF picks tasks with lag greater or equal to
|
| /linux/Documentation/driver-api/iio/ |
| H A D | triggers.rst | 15 based on hardware generated events (e.g. data ready or threshold exceeded) or
|
| /linux/Documentation/firmware-guide/acpi/apei/ |
| H A D | output_format.rst | 24 [primary][, containment warning][, reset][, threshold exceeded]\
|
| /linux/Documentation/admin-guide/mm/damon/ |
| H A D | lru_sort.rst | 267 Number of times that the time quota limit for hot regions have exceeded. 292 Number of times that the time quota limit for cold regions have exceeded.
|
| H A D | reclaim.rst | 297 Number of times that the time/space quota limits have exceeded.
|
| /linux/kernel/sched/ |
| H A D | rt.c | 994 int exceeded; in update_curr_rt() local 999 exceeded = sched_rt_runtime_exceeded(rt_rq); in update_curr_rt() 1000 if (exceeded) in update_curr_rt() 1003 if (exceeded) in update_curr_rt()
|
| /linux/drivers/mtd/ubi/ |
| H A D | Kconfig | 21 of UBI devices. When this threshold is exceeded, UBI starts performing
|
| /linux/Documentation/watchdog/ |
| H A D | watchdog-api.rst | 178 exceeded:
|
| /linux/Documentation/networking/ |
| H A D | kcm.rst | 103 error when it is exceeded.
|