Searched hist:d5172f2585cd0fc9788aa9b25d3dce6483321792 (Results 1 – 3 of 3) sorted by relevance
/linux/tools/testing/selftests/powerpc/pmu/sampling_tests/ |
H A D | mmcr0_fc56_pmc1ce_test.c | d5172f2585cd0fc9788aa9b25d3dce6483321792 Thu Jan 27 08:20:05 CET 2022 Athira Rajeev <atrajeev@linux.vnet.ibm.com> selftests/powerpc/pmu/: Add interface test for mmcr0_fc56 field using pmc1
The testcase uses event code 0x1001e to verify two bit settings (FC5-6 and PMC1CE) in Monitor Mode Control Register 0 (MMCR0). Check if FC5-6 bit to be set in MMCR0 when not using Performance Monitor Counter 5 and 6 (PMC5 and PMC6). And also PMC1CE is expected to be set when using PMC1. Test if these fields are programmed correctly via perf interface.
Signed-off-by: Athira Rajeev <atrajeev@linux.vnet.ibm.com> [mpe: Add error checking, drop GET_MMCR_FIELD, add to .gitignore] Signed-off-by: Michael Ellerman <mpe@ellerman.id.au> Link: https://lore.kernel.org/r/20220127072012.662451-14-kjain@linux.ibm.com
|
H A D | .gitignore | diff d5172f2585cd0fc9788aa9b25d3dce6483321792 Thu Jan 27 08:20:05 CET 2022 Athira Rajeev <atrajeev@linux.vnet.ibm.com> selftests/powerpc/pmu/: Add interface test for mmcr0_fc56 field using pmc1
The testcase uses event code 0x1001e to verify two bit settings (FC5-6 and PMC1CE) in Monitor Mode Control Register 0 (MMCR0). Check if FC5-6 bit to be set in MMCR0 when not using Performance Monitor Counter 5 and 6 (PMC5 and PMC6). And also PMC1CE is expected to be set when using PMC1. Test if these fields are programmed correctly via perf interface.
Signed-off-by: Athira Rajeev <atrajeev@linux.vnet.ibm.com> [mpe: Add error checking, drop GET_MMCR_FIELD, add to .gitignore] Signed-off-by: Michael Ellerman <mpe@ellerman.id.au> Link: https://lore.kernel.org/r/20220127072012.662451-14-kjain@linux.ibm.com
|
H A D | Makefile | diff d5172f2585cd0fc9788aa9b25d3dce6483321792 Thu Jan 27 08:20:05 CET 2022 Athira Rajeev <atrajeev@linux.vnet.ibm.com> selftests/powerpc/pmu/: Add interface test for mmcr0_fc56 field using pmc1
The testcase uses event code 0x1001e to verify two bit settings (FC5-6 and PMC1CE) in Monitor Mode Control Register 0 (MMCR0). Check if FC5-6 bit to be set in MMCR0 when not using Performance Monitor Counter 5 and 6 (PMC5 and PMC6). And also PMC1CE is expected to be set when using PMC1. Test if these fields are programmed correctly via perf interface.
Signed-off-by: Athira Rajeev <atrajeev@linux.vnet.ibm.com> [mpe: Add error checking, drop GET_MMCR_FIELD, add to .gitignore] Signed-off-by: Michael Ellerman <mpe@ellerman.id.au> Link: https://lore.kernel.org/r/20220127072012.662451-14-kjain@linux.ibm.com
|