Searched full:replaceable (Results 1 – 15 of 15) sorted by relevance
54 * @readw: [REPLACEABLE] hardware specific function for read short55 * @writew: [REPLACEABLE] hardware specific function for write short56 * @command: [REPLACEABLE] hardware specific function for writing58 * @wait: [REPLACEABLE] hardware specific function for wait on ready59 * @bbt_wait: [REPLACEABLE] hardware specific function for bbt wait on ready60 * @unlock_all: [REPLACEABLE] hardware specific function for unlock all61 * @read_bufferram: [REPLACEABLE] hardware specific function for BufferRAM Area62 * @write_bufferram: [REPLACEABLE] hardware specific function for BufferRAM Area63 * @read_word: [REPLACEABLE] hardware specific function for read65 * @write_word: [REPLACEABLE] hardware specific function for write[all …]
122 * @badblock_pattern: [REPLACEABLE] bad block scan pattern used for
13 FSI (FRU (Field Replaceable Unit) Service Interface) is a two wire bus. The
53 The FRU (Field Replaceable Unit) type
40 not replaceable and provide functionality which is complete hardware50 Generic functions are not replaceable and provide functionality which77 - [REPLACEABLE]79 Replaceable members hold hardware related functions which can be
26 parallel. In general, this is the Field Replaceable Unit (FRU) which
15 * XXX Some of this code should be replaceable by the upcoming OPP layer
2938 * nand_read_page_swecc - [REPLACEABLE] software ECC based page read function2984 * nand_read_subpage - [REPLACEABLE] ECC based sub-page read function3095 * nand_read_page_hwecc - [REPLACEABLE] hardware ECC based page read function3233 * nand_read_page_syndrome - [REPLACEABLE] hardware ECC syndrome based page read3625 * nand_read_oob_std - [REPLACEABLE] the most common OOB data read function3638 * nand_read_oob_syndrome - [REPLACEABLE] OOB data read function for HW ECC3692 * nand_write_oob_std - [REPLACEABLE] the most common OOB data write function3706 * nand_write_oob_syndrome - [REPLACEABLE] OOB data write function for HW ECC4048 * nand_write_page_swecc - [REPLACEABLE] software ECC based page write function4077 * nand_write_page_hwecc - [REPLACEABLE] hardware ECC based page write function[all …]
135 The DDR5 device contains number of memory media Field Replaceable Units (FRU)
3 * FRU (Field-Replaceable Unit) Memory Poison Manager
775 * A Greybus module represents a user-replaceable component on a GMP
1378 replacable||replaceable
1255 u8 FRUC; /* Field Replaceable Unit Code - not used */
8100 /* enum: Field Replaceable Unit inventory information for use on IPMI
10719 /* enum: Field Replaceable Unit inventory information for use on IPMI