Lines Matching +full:periodic +full:- +full:op +full:- +full:mode

69 .Op Ar start Op Ar stop
79 .Cm show foreign Op Ar volume
153 .Cm cache Ar volume Op Ar setting Oo Ar value Oc Op ...
176 .Ar drive Ns Op \&, Ns Ar drive Ns Op ",..."
177 .Op Ar drive Ns Op \&, Ns Ar drive Ns Op ",..."
187 .Cm add Ar drive Op Ar volume
207 .Cm patrol Ar command Op Ar interval Op Ar start
217 .Cm foreign clear Op Ar config
222 .Cm foreign diag Op Ar config
227 .Cm foreign preview Op Ar config
232 .Cm foreign import Op Ar config
252 .Cm ctrlprop Ar rebuild Op Ar rate
257 .Cm ctrlprop Ar alarm Op Ar 0/1
270 .Bl -tag -width indent
294 .Bl -tag -width indent
347 The fifth group of commands are used to manage controller-wide operations.
350 .Bl -tag -width indent
370 .Op Ar start Op Ar stop
382 .Bl -tag -width indent
386 Periodic progress updates for long-running operations such as background
421 the controller for each low-level request.
433 .Bl -tag -width indent
462 .Bl -tag -width indent
496 Abort an in-progress rebuild operation on
507 .Bl -tag -width indent
508 .It Cm cache Ar volume Op Ar setting Oo Ar value Oc Op ...
525 .Bl -tag -width indent
534 .It Cm write-back
535 Use write-back policy for cached writes.
536 .It Cm write-through
537 Use write-through policy for cached writes.
538 .It Cm read-ahead Ar value
547 .It Cm bad-bbu-write-cache Ar value
558 .It Cm write-cache Ar value
585 .Bl -tag -width indent
591 .Ar drive Ns Op \&, Ns Ar drive Ns Op ",..."
592 .Op Ar drive Ns Op \&, Ns Ar drive Ns Op ",..."
599 .Bl -tag -width indent
646 .It Cm add Ar drive Op Ar volume
671 .Bl -tag -width indent
672 .It Cm patrol Ar command Op Ar interval Op Ar start
673 Set the patrol read operation mode.
677 .Bl -tag -width indent
681 Enable periodic patrol reads initiated by the firmware.
692 argument specifies a non-negative, relative start time for the next patrol read.
708 .It Cm foreign clear Op config
714 .It Cm foreign diag Op config
720 .It Cm foreign preview Op config
726 .It Cm foreign import Op config
739 regardless of the BBU mode.
741 even if transparent learning mode is enabled.
745 .Bl -tag -width indent
746 .It Cm learn-delay
749 .It Cm autolearn-mode
750 Enable or disable automatic periodic battery relearning.
756 Alternatively, a mode of 0, 1 or 2 may be given.
757 Mode 0 enables periodic relearning, mode 1 disables it, and mode 2 disables
760 .It Cm bbu-mode
761 Set the BBU's mode of operation.
768 .It Cm ctrlprop Ar rebuild Op Ar rate
770 With an integer argument (0-100), set that value as the new rebuild rate for volumes.
771 .It Cm ctrlprop Ar alarm Op Ar 0/1
780 .Dl Nm Cm cache mfid0 write-back
807 Configure the adapter to run periodic patrol reads once a week with the first