Lines Matching +full:rx +full:- +full:input +full:- +full:m
1 /*-
29 * The following set of constants are from Document SFF-8436
34 * 1) 256-byte addressable block and 128-byte pages
35 * 2) Lower 128-bytes addresses always refer to the same page
44 * 0-127 Monitoring data & page select byte
45 * 128-255:
48 * 128-191 Base ID Fields
49 * 191-223 Extended ID
50 * 223-255 Vendor Specific ID
53 * 128-255 App-specific data
56 * 128-255 User EEPROM Data
59 * 128-223 Thresholds
60 * 225-237 Vendor Specific
61 * 238-253 Channel Controls/Monitor
62 * 254-255 Reserverd
69 /* Table 17 - Lower Memory Map */
72 SFF_8436_STATUS = 1, /* 2-bytes status (Table 18) */
73 SFF_8436_INTR_START = 3, /* Interrupt flags (Tables 19-21) */
81 SFF_8436_RX_CH1_MSB = 34, /* Internally measured RX input power */
83 SFF_8436_RX_CH2_MSB = 36, /* Internally measured RX input power */
85 SFF_8436_RX_CH3_MSB = 38, /* Internally measured RX input power */
87 SFF_8436_RX_CH4_MSB = 40, /* Internally measured RX input power */
107 /* Table 18 - Status Indicators bits */
120 * Table 29 - Serial ID: Data fields.
122 * Note that this table is mostly the same as used in SFF-8472.
149 * 50um multimode fiber, units of 2 m */
151 * OM2 fiber, units of 1 m */
153 * 50um multi-mode fiber, units of 1m*/
156 * 8074, units of 1m. 0 means this is
159 * greater than 254 m. */
179 * an 8-bit value in Degrees C. A value
206 * Fields (bytes 192-222 incl) */