Lines Matching +full:step +full:- +full:down
5 - compatible : "cirrus,cs35l33"
7 - reg : the I2C address of the device for I2C
9 - VA-supply, VP-supply : power supplies for the device,
15 - reset-gpios : gpio used to reset the amplifier
17 - interrupts : IRQ line info CS35L33.
18 (See Documentation/devicetree/bindings/interrupt-controller/interrupts.txt
21 - cirrus,boost-ctl : Booster voltage use to supply the amp. If the value is
23 a value of 1 and will increase at a step size of 100mV until a maximum of
26 - cirrus,ramp-rate : On power up, it affects the time from when the power
27 up sequence begins to the time the audio reaches a full-scale output.
28 On power down, it affects the time from when the power-down sequence
34 - cirrus,boost-ipk : The maximum current allowed for the boost converter.
36 with a step size of 15625uA. The default is 2500000uA.
38 - cirrus,imon-adc-scale : Configures the scaling of data bits from the IMON
39 ADC data word. This property can be set as a value of 0 for bits 15 down
40 to 0, 6 for 21 down to 6, 7, for 22 down to 7, 8 for 23 down to 8.
43 Optional H/G Algorithm sub-node:
45 The cs35l33 node can have a single "cirrus,hg-algo" sub-node that will enable
48 - cirrus,hg-algo : Sub-node for internal Class H/G algorithm that
51 Optional properties for the "cirrus,hg-algo" sub-node:
53 - cirrus,mem-depth : Memory depth for the Class H/G algorithm measured in
57 cirrus,release-rate : The number of consecutive LRCLK periods before
61 - cirrus,ldo-thld : Configures the signal threshold at which the PWM output
63 of 1 and increases with a step size of 50mV to a maximum of 750mV (value of
66 - cirrus,ldo-path-disable : This is a boolean property. If present, the H/G
70 - cirrus,ldo-entry-delay : The LDO entry delay in milliseconds before the H/G
75 - cirrus,vp-hg-auto : This is a boolean property. When set, class H/G VPhg
78 - cirrus,vp-hg : Class H/G algorithm VPhg. Controls the H/G algorithm's
81 by 100mV per step to a maximum of 5500mV.
83 - cirrus,vp-hg-rate : The rate (number of LRCLK periods) at which the VPhg is
89 - cirrus,vp-hg-va : VA calculation reference for automatic VPhg tracking
91 1800mV with a step size of 50mV up to a maximum value of 1750mV.
100 VA-supply = <&ldo5_reg>;
101 VP-supply = <&ldo5_reg>;
103 interrupt-parent = <&gpio8>;
106 reset-gpios = <&cs47l91 34 0>;
108 cirrus,ramp-rate = <0x0>;
109 cirrus,boost-ctl = <0x30>; /* VBST = 8000mV */
110 cirrus,boost-ipk = <0xE0>; /* 3600mA */
111 cirrus,imon-adc-scale = <0> /* Bits 15 down to 0 */
113 cirrus,hg-algo {
114 cirrus,mem-depth = <0x3>;
115 cirrus,release-rate = <0x3>;
116 cirrus,ldo-thld = <0x1>;
117 cirrus,ldo-path-disable = <0x0>;
118 cirrus,ldo-entry-delay=<0x4>;
119 cirrus,vp-hg-auto;
120 cirrus,vp-hg=<0xF>;
121 cirrus,vp-hg-rate=<0x2>;
122 cirrus,vp-hg-va=<0x0>;