Lines Matching +full:bcm7445 +full:- +full:sata +full:- +full:phy
1 * Broadcom SATA3 PHY
4 - compatible: should be one or more of
5 "brcm,bcm7216-sata-phy"
6 "brcm,bcm7425-sata-phy"
7 "brcm,bcm7445-sata-phy"
8 "brcm,iproc-ns2-sata-phy"
9 "brcm,iproc-nsp-sata-phy"
10 "brcm,phy-sata3"
11 "brcm,iproc-sr-sata-phy"
12 "brcm,bcm63138-sata-phy"
13 - address-cells: should be 1
14 - size-cells: should be 0
15 - reg: register ranges for the PHY PCB interface
16 - reg-names: should be "phy" and "phy-ctrl"
17 The "phy-ctrl" registers are only required for
18 "brcm,iproc-ns2-sata-phy" and "brcm,iproc-sr-sata-phy".
20 Sub-nodes:
21 Each port's PHY should be represented as a sub-node.
23 Sub-nodes required properties:
24 - reg: the PHY number
25 - phy-cells: generic PHY binding; must be 0
27 Sub-nodes optional properties:
28 - brcm,enable-ssc: use spread spectrum clocking (SSC) on this port
29 This property is not applicable for "brcm,iproc-ns2-sata-phy",
30 "brcm,iproc-nsp-sata-phy" and "brcm,iproc-sr-sata-phy".
32 - brcm,rxaeq-mode: string that indicates the desired RX equalizer
36 "manual" (brcm,rxaeq-value is used in that case)
38 - brcm,rxaeq-value: when 'rxaeq-mode' is set to "manual", provides the RX
42 sata-phy@f0458100 {
43 compatible = "brcm,bcm7445-sata-phy", "brcm,phy-sata3";
45 reg-names = "phy";
46 #address-cells = <1>;
47 #size-cells = <0>;
49 sata-phy@0 {
51 #phy-cells = <0>;
54 sata-phy@1 {
56 #phy-cells = <0>;