Lines Matching +full:i +full:- +full:drive
2 .\" SPDX-License-Identifier: BSD-2-Clause
33 .Nd Mylex DAC-family Parallel SCSI RAID driver
38 .Bd -ragged -offset indent
46 .Bd -literal -offset indent
52 driver provides support for Mylex DAC-family PCI to SCSI RAID controllers,
59 .Bl -bullet -compact
61 Mylex DAC960P (Wide Fast SCSI-2)
63 Mylex DAC960PD / DEC KZPSC (Wide Fast SCSI-2)
65 Mylex DAC960PDU (Ultra SCSI-3)
67 Mylex DAC960PL (Wide Fast SCSI-2)
69 Mylex DAC960PJ (Wide Ultra SCSI-3)
71 Mylex DAC960PG (Wide Ultra SCSI-3)
73 Mylex DAC960PU / DEC PZPAC (Wide Ultra SCSI-3)
81 RAIDarray 230 controllers, aka the Ultra-SCSI DEC KZPAC-AA (1-ch, 4MB
82 cache), KZPAC-CA (3-ch, 4MB), KZPAC-CB (3-ch, 8MB cache)
86 .Bl -diag
91 .It mlx%d: physical drive %d:%d not responding
93 The drive at channel:target is not responding; it may have failed or
97 Drive startup is in progress; this may take several minutes.
102 .It mlx%d: mirror race on a critical system drive
106 .It mlx%d: physical drive %d:%d COD mismatch
108 Configuration data on the drive at channel:target does not match the
110 .It mlx%d: system drive installation aborted
127 .Bl -diag
139 .It mlx%d: error fetching drive status
145 Creation of the system drive instances failed; attachment of one or more
149 The indicated system drive is being detached.
152 The indicated system drive is still open or mounted;
159 .Bl -diag
160 .It mlx%d: ENQUIRY failed - %s
163 .It mlx%d: FLUSH failed - %s
164 .It mlx%d: CHECK ASYNC failed - %s
165 .It mlx%d: REBUILD ASYNC failed - %s
166 .It mlx%d: command failed - %s
169 .It mlx%d: I/O beyond end of unit (%u,%d > %u)
170 .It mlx%d: I/O error - %s
172 An I/O error was reported by the controller.
173 .It mlx%d: periodic enquiry failed - %s
179 .It mlxd%d: drive offline
180 .It mlxd%d: drive online
181 .It mlxd%d: drive critical
184 .It mlx%d: physical drive %d:%d reset
185 .It mlx%d: physical drive %d:%d killed %s
186 .It "mlx%d: physical drive %d:%d error log: sense = %d asc = %x asq = %x"
189 The drive at channel:target has been reset, killed for the given reason,
192 .It mlx%d: error reading message log - %s
198 A user-initiated consistency check has started/completed.
199 .It mlx%d: drive rebuild started for %d:%d
200 .It mlx%d: drive rebuild completed
202 A user-initiated physical drive rebuild has started/completed.
206 An automatic system drive consistency check
207 or physical drive rebuild has started/completed.
210 .It mlx%d: pause command failed - %s
212 .It mlx%d: resume command failed - %s
229 .An -nosplit