Lines Matching +full:polarity +full:- +full:active +full:- +full:low
51 .Bd -literal
62 dev.lm75.0.polarity: active-low
65 .Bl -tag -width ".Va dev.lm75.%d.temperature"
67 Is the read-only value of the current temperature read by the sensor.
84 .It Va dev.lm75.%d.polarity
85 Sets the polarity of the sensor interrupt pin.
86 It can be set to 'active-low' (default) or 'active-high'.
87 Please note that the output pin is an open-drain output and it needs a
88 proper pull-up resistor to work.
92 active, i.e., it can be woken up by setting this option to '0' again.
107 driver supports both the low and the high resolution models.
109 The low resolution model (lm75) provides a 9 bit output with the LSB
115 The driver tries to auto-detect the
127 .Bl -tag -width ".Va hint.lm75.%d.addr"
146 .Bd -literal
158 .Bl -tag -width ".Va compatible"
162 Indicates which 7-bit i2c address the
182 .An -nosplit