Lines Matching +full:two +full:- +full:ethernet

3 .\"-
8 .\" at Lawrence Berkeley Laboratory under DARPA contract BG 91-66 and
42 .Nd "AMD Am7900 LANCE and Am79C9xx ILACC/PCnet Ethernet interface driver"
47 .Bd -ragged -offset indent
54 .Bd -literal -offset indent
58 For ISA non-PnP adapters, the port address as well as the IRQ and the DRQ
74 driver provides support for Ethernet adapters based on the
78 .Pq CMOS, pin-compatible
79 Local Area Network Controller for Ethernet
85 driver also supports Ethernet adapters based on the
91 family of chips, which are single-chip implementations of a
98 bus Ethernet chips as an
99 .Tn AMD Am79C970 PCnet-PCI
101 .Tn AMD Am79C971 PCnet-FAST
114 Selective reception of multicast Ethernet frames is provided by a 64-bit mask;
115 multicast destination addresses are hashed to a bit entry using the Ethernet
123 bus Ethernet adapters which are based on the following chips:
125 .Bl -bullet -compact
129 .Tn AMD Am79C960 PCnet-ISA
131 .Tn AMD Am79C961 PCnet-ISA+
133 .Tn AMD Am79C961A PCnet-ISA II
136 This includes support for the following Ethernet adapters:
138 ISA non-PnP:
140 .Bl -bullet -compact
151 .Bl -bullet -compact
155 .Tn AMD PCnet-32
157 .Tn AMD PCnet-ISA
159 .Tn Allied Telesyn AT-1500
167 .Tn Melco Inc. LGY-IV
180 bus Ethernet adapters.
184 bus Ethernet chips supported by the
188 .Bl -bullet -compact
190 .Tn AMD Am53C974/Am79C970/Am79C974 PCnet-PCI
192 .Tn AMD Am79C970A PCnet-PCI II
194 .Tn AMD Am79C971 PCnet-FAST
196 .Tn AMD Am79C972 PCnet-FAST+
198 .Tn AMD Am79C973/Am79C975 PCnet-FAST III
200 .Tn AMD Am79C976 PCnet-PRO
202 .Tn AMD Am79C978 PCnet-Home
205 This includes support for the following Ethernet adapters:
207 .Bl -bullet -compact
211 .Tn Allied Telesyn AT-2450 and AT-2700 series
213 .Tn VMware emulated AMD Am79C970A PCnet-PCI II interface
222 bus Ethernet adapters:
223 .Bl -tag -width ".Cm 10base5/AUI"
233 .Bl -tag -width ".Cm full-duplex"
234 .It Cm full-duplex
240 driver does not support selecting 100Mbps (Fast Ethernet) media types.
242 .Bl -diag
244 More packets came in from the Ethernet than there was space in the
253 The Ethernet carrier disappeared during an attempt to transmit.
259 The Ethernet was extremely busy or jammed,
267 This value can be used to determine the distance from the Ethernet tap to
268 the point on the Ethernet cable that is shorted or open (unterminated).
273 driver allocates buffers large enough to receive maximum sized Ethernet
275 larger than allowed by the Ethernet standard.
332 .\" The work-around is to ignore packets with an invalid destination address
333 .\" (garbage will usually not match), by double-checking the destination
335 .\" This work-around can be enabled with the
343 .\" driver executes one or two calls to an inline Ethernet address comparison
348 .\" There is one comparison for each unicast packet, and two comparisons for
352 .\" .Bl -enum -compact
372 .\" .Qq de-archived