Lines Matching +full:port +full:- +full:config

3 .TH INFINIBAND-DIAGS 8 "" "" "Open IB Diagnostics"
5 INFINIBAND-DIAGS \-
7 .nr rst2man-indent-level 0
10 \\$1 \\n[an-margin]
11 level \\n[rst2man-indent-level]
12 level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
13 -
14 \\n[rst2man-indent0]
15 \\n[rst2man-indent1]
16 \\n[rst2man-indent2]
21 . nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
22 . nr rst2man-indent-level +1
27 .\" indent \\n[an-margin]
28 .\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
29 .nr rst2man-indent-level -1
30 .\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
36 infiniband\-diags is a set of utilities designed to help configure, debug, and
59 The \-D and \-G option have two forms:
60 .\" Define the common option -D for Directed routes
63 \fB\-D, \-\-Direct\fP The address specified is a directed route
70 [options] \-D [options] "0" # self port
71 [options] \-D [options] "0,1,2,1,4" # out via port 1, then 2, ...
73 (Note the second number in the path specified must match the port being
74 used. This can be specified using the port selection flag \(aq\-P\(aq or the
75 port found through the automatic selection process.)
80 .\" Define the common option -D for Directed routes
83 \fB\-D, \-\-Direct <dr_path>\fP The address specified is a directed route
90 \-D "0" # self port
91 \-D "0,1,2,1,4" # out via port 1, then 2, ...
93 (Note the second number in the path specified must match the port being
94 used. This can be specified using the port selection flag \(aq\-P\(aq or the
95 port found through the automatic selection process.)
100 .\" Define the common option -G
103 \fB\-G, \-\-Guid\fP The address specified is a Port GUID
104 .\" Define the common option -G
107 \fB\-\-port\-guid, \-G <port_guid>\fP Specify a port_guid
108 .\" Define the common option -L
111 \fB\-L, \-\-Lid\fP The address specified is a LID
112 .\" Define the common option -s
115 \fB\-s, \-\-sm_port <smlid>\fP use \(aqsmlid\(aq as the target lid for SA queries.
116 .SS Port Selection flags
117 .\" Define the common option -C
120 \fB\-C, \-\-Ca <ca_name>\fP use the specified ca_name.
121 .\" Define the common option -P
124 \fB\-P, \-\-Port <ca_port>\fP use the specified ca_port.
125 .\" Explanation of local port selection
127 .SS Local port Selection
129 Multiple port/Multiple CA support: when no IB device or port is specified
131 selects the port to use by the following criteria:
136 the first port that is ACTIVE.
138 if not found, the first port that is UP (physical link up).
141 If a port and/or CA name is specified, the libibumad library attempts
150 ibaddr # use the first port (criteria #1 above)
151 ibaddr \-C mthca1 # pick the best port from "mthca1" only.
152 ibaddr \-P 2 # use the second (active/up) port from the first available IB device.
153 ibaddr \-C mthca0 \-P 2 # use the specified port only.
161 .\" Define the common option -d
165 .B \-d
167 May be used several times (\-ddd or \-d \-d \-d).
169 .\" Define the common option -e
173 .B \-e
176 .\" Define the common option -h
179 \fB\-h, \-\-help\fP show the usage message
180 .\" Define the common option -v
184 .B \fB\-v, \-\-verbose\fP
186 May be used several times (\-vv or \-v \-v \-v)
188 .\" Define the common option -V
191 \fB\-V, \-\-version\fP show the version info.
193 .\" Define the common option -t
196 \fB\-t, \-\-timeout <timeout_ms>\fP override the default timeout for the solicited mads.
197 .\" Define the common option -z
201 .B \fB\-\-outstanding_smps, \-o <val>\fP
206 .\" Define the common option --node-name-map
209 \fB\-\-node\-name\-map <node\-name\-map>\fP Specify a node name map.
215 .\" Define the common option -z
218 \fB\-\-config, \-z <config_file>\fP Specify alternate config file.
221 Default: /etc/infiniband-diags/ibdiag.conf
226 The following config files are common amongst many of the utilities.
227 .\" Common text for the config file
229 .SS CONFIG FILE
231 /etc/infiniband-diags/ibdiag.conf
233 A global config file is provided to set some of the common options for all
234 tools. See supplied config file for details.
242 This functionality is provided by the opensm\-libs package. See \fBopensm(8)\fP
266 0x0008f104003f125c "IB1 (Rack 11 slot 1 ) ISR9288/ISR9096 Voltaire sLB\-24D"
267 0x0008f104003f125d "IB1 (Rack 11 slot 1 ) ISR9288/ISR9096 Voltaire sLB\-24D"
268 0x0008f104003f10d2 "IB1 (Rack 11 slot 2 ) ISR9288/ISR9096 Voltaire sLB\-24D"
269 0x0008f104003f10d3 "IB1 (Rack 11 slot 2 ) ISR9288/ISR9096 Voltaire sLB\-24D"
270 0x0008f104003f10bf "IB1 (Rack 11 slot 12 ) ISR9288/ISR9096 Voltaire sLB\-24D"
273 0x0008f10400400e2d "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB\-12D"
274 0x0008f10400400e2e "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB\-12D"
275 0x0008f10400400e2f "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB\-12D"
276 0x0008f10400400e31 "IB1 (Rack 11 spine 2 ) ISR9288 Voltaire sFB\-12D"
277 0x0008f10400400e32 "IB1 (Rack 11 spine 2 ) ISR9288 Voltaire sFB\-12D"
300 whether switch port 0 is base or enhanced, and the LID and LMC of port 0.
302 left is the port number of the current node. On the right is the peer node
304 followed by \- followed by NodeGUID with the port number in square brackets.
323 # Initiated from node 0008f10403960558 port 0008f10403960559
325 Non\-Chassis Nodes
331 Switch 24 "S\-005442ba00003080" # "ISR9024 Voltaire" base port 0 lid 6 lmc 0
332 [22] "H\-0008f10403961354"[1](8f10403961355) # "MT23108 InfiniHost Mellanox Technologies…
333 [10] "S\-0008f10400410015"[1] # "SW\-6IB4 Voltaire" lid 3 4xSDR
334 [8] "H\-0008f10403960558"[2](8f1040396055a) # "MT23108 InfiniHost Mellanox Technologies…
335 [6] "S\-0008f10400410015"[3] # "SW\-6IB4 Voltaire" lid 3 4xSDR
336 [12] "H\-0008f10403960558"[1](8f10403960559) # "MT23108 InfiniHost Mellanox Technologies…
341 Switch 8 "S\-0008f10400410015" # "SW\-6IB4 Voltaire" base port 0 lid 3 lmc 0
342 [6] "H\-0008f10403960984"[1](8f10403960985) # "MT23108 InfiniHost Mellanox Technologies…
343 [4] "H\-005442b100004900"[1](5442b100004901) # "MT23108 InfiniHost Mellanox Technologies…
344 [1] "S\-005442ba00003080"[10] # "ISR9024 Voltaire" lid 6 1xSDR
345 [3] "S\-005442ba00003080"[6] # "ISR9024 Voltaire" lid 6 4xSDR
350 Ca 2 "H\-0008f10403960984" # "MT23108 InfiniHost Mellanox Technologies"
351 [1](8f10403960985) "S\-0008f10400410015"[6] # lid 16 lmc 1 "SW\-6IB4 Voltaire" lid 3 4x…
356 Ca 2 "H\-005442b100004900" # "MT23108 InfiniHost Mellanox Technologies"
357 [1](5442b100004901) "S\-0008f10400410015"[4] # lid 12 lmc 1 "SW\-6IB4 Voltaire" lid 3 4…
362 Ca 2 "H\-0008f10403961354" # "MT23108 InfiniHost Mellanox Technologies"
363 [1](8f10403961355) "S\-005442ba00003080"[22] # lid 4 lmc 1 "ISR9024 Voltaire" li…
368 Ca 2 "H\-0008f10403960558" # "MT23108 InfiniHost Mellanox Technologies"
369 [2](8f1040396055a) "S\-005442ba00003080"[8] # lid 14 lmc 1 "ISR9024 Voltaire" lid 6 4xS…
370 [1](8f10403960559) "S\-005442ba00003080"[12] # lid 10 lmc 1 "ISR9024 Voltaire" l…
378 displayed as "Non\-Chassis Nodes". External ports are also shown on the
393 .SS Port information
439 \-\-enable\-compat\-utils is specified at build time.