Lines Matching +full:port +full:- +full:config

5 IBQUERYERRORS \- query and report IB port counters
7 .nr rst2man-indent-level 0
10 \\$1 \\n[an-margin]
11 level \\n[rst2man-indent-level]
12 level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
13 -
14 \\n[rst2man-indent0]
15 \\n[rst2man-indent1]
16 \\n[rst2man-indent2]
21 . nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
22 . nr rst2man-indent-level +1
27 .\" indent \\n[an-margin]
28 .\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
29 .nr rst2man-indent-level -1
30 .\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
38 The default behavior is to report the port error counters which exceed a
39 threshold for each port in the fabric. The default threshold is zero (0).
42 In addition to reporting errors on every port. ibqueryerrors can report the
43 port transmit and receive data as well as report full link information to the
44 remote port if available.
47 \fB\-s, \-\-suppress <err1,err2,...>\fP
50 \fB\-c, \-\-suppress\-common\fP
54 \fB\-r, \-\-report\-port\fP
55 Report the port information. This includes LID, port, external port (if
56 applicable), link speed setting, remote GUID, remote port, remote external port
59 \fB\-\-data\fP
62 \fB\-\-threshold\-file <filename>\fP
63 Specify an alternate threshold file. The default is /etc/infiniband-diags/error_thresholds
65 \fB\-\-switch\fP print data for switch\(aqs only
67 \fB\-\-ca\fP print data for CA\(aqs only
69 \fB\-\-skip\-sl\fP Use the default sl for queries. This is not recommended when
72 \fB\-\-router\fP print data for routers only
74 \fB\-\-clear\-errors \-k\fP Clear error counters after read.
76 \fB\-\-clear\-counts \-K\fP Clear data counters after read.
79 are printed or not. See \fB\-\-counters\fP and \fB\-\-data\fP for details on
82 \fB\-\-details\fP include receive error and transmit discard details
84 \fB\-\-counters\fP print data counters only
88 .\" Define the common option -G
91 \fB\-\-port\-guid, \-G <port_guid>\fP Specify a port_guid
92 .\" Define the common option -D for Directed routes
95 \fB\-D, \-\-Direct <dr_path>\fP The address specified is a directed route
102 \-D "0" # self port
103 \-D "0,1,2,1,4" # out via port 1, then 2, ...
105 (Note the second number in the path specified must match the port being
106 used. This can be specified using the port selection flag \(aq\-P\(aq or the
107 port found through the automatic selection process.)
113 \fBNote:\fP For switches results are printed for all ports not just switch port 0.
115 \fB\-S <port_guid>\fP same as "\-G". (provided only for backward compatibility)
117 .\" Define the common option load-cache
120 \fB\-\-load\-cache <filename>\fP
124 .SS Port Selection flags
125 .\" Define the common option -C
128 \fB\-C, \-\-Ca <ca_name>\fP use the specified ca_name.
129 .\" Define the common option -P
132 \fB\-P, \-\-Port <ca_port>\fP use the specified ca_port.
133 .\" Explanation of local port selection
135 .SS Local port Selection
137 Multiple port/Multiple CA support: when no IB device or port is specified
139 selects the port to use by the following criteria:
144 the first port that is ACTIVE.
146 if not found, the first port that is UP (physical link up).
149 If a port and/or CA name is specified, the libibumad library attempts
158 ibaddr # use the first port (criteria #1 above)
159 ibaddr \-C mthca1 # pick the best port from "mthca1" only.
160 ibaddr \-P 2 # use the second (active/up) port from the first available IB device.
161 ibaddr \-C mthca0 \-P 2 # use the specified port only.
169 .\" Define the common option -z
172 \fB\-\-config, \-z <config_file>\fP Specify alternate config file.
175 Default: /etc/infiniband-diags/ibdiag.conf
178 .\" Define the common option -z
182 .B \fB\-\-outstanding_smps, \-o <val>\fP
187 .\" Define the common option --node-name-map
190 \fB\-\-node\-name\-map <node\-name\-map>\fP Specify a node name map.
196 .\" Define the common option -t
199 \fB\-t, \-\-timeout <timeout_ms>\fP override the default timeout for the solicited mads.
200 .\" Define the common option -y
204 .B \fB\-y, \-\-m_key <key>\fP
205 use the specified M_key for requests. If non\-numeric value (like \(aqx\(aq)
209 .\" Define the common option -d
213 .B \-d
215 May be used several times (\-ddd or \-d \-d \-d).
217 .\" Define the common option -e
221 .B \-e
224 .\" Define the common option -h
227 \fB\-h, \-\-help\fP show the usage message
228 .\" Define the common option -v
232 .B \fB\-v, \-\-verbose\fP
234 May be used several times (\-vv or \-v \-v \-v)
236 .\" Define the common option -V
239 \fB\-V, \-\-version\fP show the version info.
241 \fB\-R\fP (This option is obsolete and does nothing)
244 \fB\-1\fP if scan fails.
252 /etc/infiniband-diags/error_thresholds
271 .\" Common text for the config file
273 .SS CONFIG FILE
275 /etc/infiniband-diags/ibdiag.conf
277 A global config file is provided to set some of the common options for all
278 tools. See supplied config file for details.
286 This functionality is provided by the opensm\-libs package. See \fBopensm(8)\fP
310 0x0008f104003f125c "IB1 (Rack 11 slot 1 ) ISR9288/ISR9096 Voltaire sLB\-24D"
311 0x0008f104003f125d "IB1 (Rack 11 slot 1 ) ISR9288/ISR9096 Voltaire sLB\-24D"
312 0x0008f104003f10d2 "IB1 (Rack 11 slot 2 ) ISR9288/ISR9096 Voltaire sLB\-24D"
313 0x0008f104003f10d3 "IB1 (Rack 11 slot 2 ) ISR9288/ISR9096 Voltaire sLB\-24D"
314 0x0008f104003f10bf "IB1 (Rack 11 slot 12 ) ISR9288/ISR9096 Voltaire sLB\-24D"
317 0x0008f10400400e2d "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB\-12D"
318 0x0008f10400400e2e "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB\-12D"
319 0x0008f10400400e2f "IB1 (Rack 11 spine 1 ) ISR9288 Voltaire sFB\-12D"
320 0x0008f10400400e31 "IB1 (Rack 11 spine 2 ) ISR9288 Voltaire sFB\-12D"
321 0x0008f10400400e32 "IB1 (Rack 11 spine 2 ) ISR9288 Voltaire sFB\-12D"