Lines Matching +full:port +full:- +full:config
5 IBCCQUERY \- query congestion control settings/info
7 .nr rst2man-indent-level 0
10 \\$1 \\n[an-margin]
11 level \\n[rst2man-indent-level]
12 level margin: \\n[rst2man-indent\\n[rst2man-indent-level]]
13 -
14 \\n[rst2man-indent0]
15 \\n[rst2man-indent1]
16 \\n[rst2man-indent2]
21 . nr rst2man-indent\\n[rst2man-indent-level] \\n[an-margin]
22 . nr rst2man-indent-level +1
27 .\" indent \\n[an-margin]
28 .\" old: \\n[rst2man-indent\\n[rst2man-indent-level]]
29 .nr rst2man-indent-level -1
30 .\" new: \\n[rst2man-indent\\n[rst2man-indent-level]]
35 ibccquery [common_options] [\-c cckey] [\-\-dgid gid] <op> <lid|guid> [port]
54 \fB\-\-cckey, \-c <cckey>\fP
56 \fB\-\-dgid <gid>\fP
59 .\" Define the common option -d
63 .B \-d
65 May be used several times (\-ddd or \-d \-d \-d).
67 .\" Define the common option -e
71 .B \-e
74 .\" Define the common option -h
77 \fB\-h, \-\-help\fP show the usage message
78 .\" Define the common option -v
82 .B \fB\-v, \-\-verbose\fP
84 May be used several times (\-vv or \-v \-v \-v)
86 .\" Define the common option -V
89 \fB\-V, \-\-version\fP show the version info.
91 .\" Define the common option -G
94 \fB\-G, \-\-Guid\fP The address specified is a Port GUID
95 .\" Define the common option -L
98 \fB\-L, \-\-Lid\fP The address specified is a LID
99 .\" Define the common option -s
102 \fB\-s, \-\-sm_port <smlid>\fP use \(aqsmlid\(aq as the target lid for SA queries.
103 .SS Port Selection flags
104 .\" Define the common option -C
107 \fB\-C, \-\-Ca <ca_name>\fP use the specified ca_name.
108 .\" Define the common option -P
111 \fB\-P, \-\-Port <ca_port>\fP use the specified ca_port.
112 .\" Explanation of local port selection
114 .SS Local port Selection
116 Multiple port/Multiple CA support: when no IB device or port is specified
118 selects the port to use by the following criteria:
123 the first port that is ACTIVE.
125 if not found, the first port that is UP (physical link up).
128 If a port and/or CA name is specified, the libibumad library attempts
137 ibaddr # use the first port (criteria #1 above)
138 ibaddr \-C mthca1 # pick the best port from "mthca1" only.
139 ibaddr \-P 2 # use the second (active/up) port from the first available IB device.
140 ibaddr \-C mthca0 \-P 2 # use the specified port only.
148 .\" Define the common option -y
152 .B \fB\-y, \-\-m_key <key>\fP
153 use the specified M_key for requests. If non\-numeric value (like \(aqx\(aq)
156 .\" Define the common option -z
159 \fB\-\-config, \-z <config_file>\fP Specify alternate config file.
162 Default: /etc/infiniband-diags/ibdiag.conf
166 .\" Common text for the config file
168 .SS CONFIG FILE
170 /etc/infiniband-diags/ibdiag.conf
172 A global config file is provided to set some of the common options for all
173 tools. See supplied config file for details.
181 ibccquery SwitchPortCongestionSetting 3 # Query all Switch Port Congestion Settings
182 ibccquery SwitchPortCongestionSetting 3 1 # Query Switch Port Congestion Setting for port 1