Lines Matching +full:disable +full:- +full:dc

2 .\" SPDX-License-Identifier: BSD-2-Clause
4 .\" Copyright (c) 2018-2024 Gavin D. Howard and contributors.
28 .TH "DC" "1" "August 2024" "Gavin D. Howard" "General Commands Manual"
32 dc \- arbitrary\-precision decimal reverse\-Polish notation calculator
34 \f[B]dc\f[R] [\f[B]\-cChiPRvVx\f[R]] [\f[B]\-\-version\f[R]]
35 [\f[B]\-\-help\f[R]] [\f[B]\-\-digit\-clamp\f[R]]
36 [\f[B]\-\-no\-digit\-clamp\f[R]] [\f[B]\-\-interactive\f[R]]
37 [\f[B]\-\-no\-prompt\f[R]] [\f[B]\-\-no\-read\-prompt\f[R]]
38 [\f[B]\-\-extended\-register\f[R]] [\f[B]\-e\f[R] \f[I]expr\f[R]]
39 [\f[B]\-\-expression\f[R]=\f[I]expr\f[R]\&...]
40 [\f[B]\-f\f[R] \f[I]file\f[R]\&...]
41 [\f[B]\-\-file\f[R]=\f[I]file\f[R]\&...]
44 dc(1) is an arbitrary\-precision calculator.
50 If no files are given on the command\-line, then dc(1) reads from
52 Otherwise, those files are processed, and dc(1) will then exit.
57 \f[B]10\f[R], they can set \f[B]DC_ENV_ARGS\f[R] to \f[B]\-e 10k\f[R],
58 and this dc(1) will always start with a \f[B]scale\f[R] of \f[B]10\f[R].
60 The following are the options that dc(1) accepts.
62 \f[B]\-C\f[R], \f[B]\-\-no\-digit\-clamp\f[R]
72 If this and/or the \f[B]\-c\f[R] or \f[B]\-\-digit\-clamp\f[R] options
77 can be queried with the \f[B]\-h\f[R] or \f[B]\-\-help\f[R] options.
79 This is a \f[B]non\-portable extension\f[R].
82 \f[B]\-c\f[R], \f[B]\-\-digit\-clamp\f[R]
93 If this and/or the \f[B]\-C\f[R] or \f[B]\-\-no\-digit\-clamp\f[R]
98 can be queried with the \f[B]\-h\f[R] or \f[B]\-\-help\f[R] options.
100 This is a \f[B]non\-portable extension\f[R].
103 \f[B]\-e\f[R] \f[I]expr\f[R], \f[B]\-\-expression\f[R]=\f[I]expr\f[R]
112 If this option is given on the command\-line (i.e., not in
114 then after processing all expressions and files, dc(1) will exit, unless
115 \f[B]\-\f[R] (\f[B]stdin\f[R]) was given as an argument at least once to
116 \f[B]\-f\f[R] or \f[B]\-\-file\f[R], whether on the command\-line or in
118 However, if any other \f[B]\-e\f[R], \f[B]\-\-expression\f[R],
119 \f[B]\-f\f[R], or \f[B]\-\-file\f[R] arguments are given after
120 \f[B]\-f\-\f[R] or equivalent is given, dc(1) will give a fatal error
123 This is a \f[B]non\-portable extension\f[R].
126 \f[B]\-f\f[R] \f[I]file\f[R], \f[B]\-\-file\f[R]=\f[I]file\f[R]
133 If this option is given on the command\-line (i.e., not in
135 then after processing all expressions and files, dc(1) will exit, unless
136 \f[B]\-\f[R] (\f[B]stdin\f[R]) was given as an argument at least once to
137 \f[B]\-f\f[R] or \f[B]\-\-file\f[R].
138 However, if any other \f[B]\-e\f[R], \f[B]\-\-expression\f[R],
139 \f[B]\-f\f[R], or \f[B]\-\-file\f[R] arguments are given after
140 \f[B]\-f\-\f[R] or equivalent is given, dc(1) will give a fatal error
143 This is a \f[B]non\-portable extension\f[R].
146 \f[B]\-h\f[R], \f[B]\-\-help\f[R]
149 \f[B]\-I\f[R] \f[I]ibase\f[R], \f[B]\-\-ibase\f[R]=\f[I]ibase\f[R]
157 This is a \f[B]non\-portable extension\f[R].
160 \f[B]\-i\f[R], \f[B]\-\-interactive\f[R]
165 This is a \f[B]non\-portable extension\f[R].
168 \f[B]\-L\f[R], \f[B]\-\-no\-line\-length\f[R]
175 This is a \f[B]non\-portable extension\f[R].
178 \f[B]\-O\f[R] \f[I]obase\f[R], \f[B]\-\-obase\f[R]=\f[I]obase\f[R]
186 This is a \f[B]non\-portable extension\f[R].
189 \f[B]\-P\f[R], \f[B]\-\-no\-prompt\f[R]
194 to having them in dc(1).
202 This is a \f[B]non\-portable extension\f[R].
205 \f[B]\-R\f[R], \f[B]\-\-no\-read\-prompt\f[R]
210 used to having them in dc(1).
213 This option is also useful in hash bang lines of dc(1) scripts that
217 This option does not disable the regular prompt because the read prompt
224 This is a \f[B]non\-portable extension\f[R].
227 \f[B]\-S\f[R] \f[I]scale\f[R], \f[B]\-\-scale\f[R]=\f[I]scale\f[R]
235 This is a \f[B]non\-portable extension\f[R].
238 \f[B]\-v\f[R], \f[B]\-V\f[R], \f[B]\-\-version\f[R]
241 \f[B]\-x\f[R] \f[B]\-\-extended\-register\f[R]
247 This is a \f[B]non\-portable extension\f[R].
250 \f[B]\-z\f[R], \f[B]\-\-leading\-zeroes\f[R]
251 Makes dc(1) print all numbers greater than \f[B]\-1\f[R] and less than
255 This is a \f[B]non\-portable extension\f[R].
258 All long options are \f[B]non\-portable extensions\f[R].
260 If no files are given on the command\-line and no files or expressions
261 are given by the \f[B]\-f\f[R], \f[B]\-\-file\f[R], \f[B]\-e\f[R], or
262 \f[B]\-\-expression\f[R] options, then dc(1) reads from \f[B]stdin\f[R].
270 balanced before dc(1) parses and executes.
272 Any non\-error output is written to \f[B]stdout\f[R].
277 \f[B]Note\f[R]: Unlike other dc(1) implementations, this dc(1) will
280 \f[B]dc >&\-\f[R], it will quit with an error.
281 This is done so that dc(1) can report problems when \f[B]stdout\f[R] is
284 If there are scripts that depend on the behavior of other dc(1)
290 \f[B]Note\f[R]: Unlike other dc(1) implementations, this dc(1) will
293 \f[B]dc 2>&\-\f[R], it will quit with an error.
294 This is done so that dc(1) can exit with an error code when
297 If there are scripts that depend on the behavior of other dc(1)
313 The max allowable value for \f[B]ibase\f[R] can be queried in dc(1)
332 The max allowable value for \f[B]scale\f[R] can be queried in dc(1)
336 This is a \f[B]non\-portable extension\f[R].
347 the \f[B]\-c\f[R]/\f[B]\-\-digit\-clamp\f[R] or
348 \f[B]\-C\f[R]/\f[B]\-\-no\-digit\-clamp\f[R] options (see the
352 \f[B]\-h\f[R]/\f[B]\-\-help\f[R] option.
370 There is one exception to clamping: single\-character numbers (i.e.,
406 digit is interpreted as an 8\-bit ASCII character, making it a byte
411 This is a \f[B]non\-portable extension\f[R].
430 \f[B]\-\f[R]
451 The first value popped off of the stack must be non\-zero.
461 \f[B]a\-(a/b)*b\f[R] to \f[I]scale\f[R]
464 The first value popped off of the stack must be non\-zero.
475 The first value popped off of the stack must be non\-zero.
477 This is a \f[B]non\-portable extension\f[R].
488 non\-zero.
497 The value popped off of the stack must be non\-negative.
507 This behavior without a number is a \f[B]non\-portable extension\f[R].
516 This is a \f[B]non\-portable extension\f[R].
525 integer and non\-zero.
527 and non\-negative.
530 This is a \f[B]non\-portable extension\f[R].
538 This is a \f[B]non\-portable extension\f[R].
546 This is a \f[B]non\-portable extension\f[R].
555 This is a \f[B]non\-portable extension\f[R].
564 This is a \f[B]non\-portable extension\f[R].
573 This is a \f[B]non\-portable extension\f[R].
582 This is a \f[B]non\-portable extension\f[R].
587 If they are both non\-zero, a \f[B]1\f[R] is pushed onto the stack.
593 a short\-circuit operator.
595 This is a \f[B]non\-portable extension\f[R].
600 If at least one of them is non\-zero, a \f[B]1\f[R] is pushed onto the
606 a short\-circuit operator.
608 This is a \f[B]non\-portable extension\f[R].
673 \f[B]scale\f[R], which must be non\-negative.
694 This is a \f[B]non\-portable extension\f[R].
702 This is a \f[B]non\-portable extension\f[R].
710 This is a \f[B]non\-portable extension\f[R].
750 one\-character string where the character is the result of the mod
756 create the new string as a one\-character string.
759 This is a \f[B]non\-portable extension\f[R].
783 If either or both of the values are not numbers, dc(1) will raise an
792 If either or both of the values are not numbers, dc(1) will raise an
795 This is a \f[B]non\-portable extension\f[R].
804 If either or both of the values are not numbers, dc(1) will raise an
813 If either or both of the values are not numbers, dc(1) will raise an
816 This is a \f[B]non\-portable extension\f[R].
825 If either or both of the values are not numbers, dc(1) will raise an
834 If either or both of the values are not numbers, dc(1) will raise an
837 This is a \f[B]non\-portable extension\f[R].
846 If either or both of the values are not numbers, dc(1) will raise an
855 If either or both of the values are not numbers, dc(1) will raise an
858 This is a \f[B]non\-portable extension\f[R].
867 If either or both of the values are not numbers, dc(1) will raise an
876 If either or both of the values are not numbers, dc(1) will raise an
879 This is a \f[B]non\-portable extension\f[R].
888 If either or both of the values are not numbers, dc(1) will raise an
897 If either or both of the values are not numbers, dc(1) will raise an
900 This is a \f[B]non\-portable extension\f[R].
910 If there are no macros, or only one macro executing, dc(1) exits.
913 Pops a value from the stack which must be non\-negative and is used the
916 macros, dc(1) exits.
922 to make dc(1) exit with the \f[B]Q\f[R] command, so the sequence
923 \f[B],Q\f[R] will make dc(1) exit.
926 This is a \f[B]non\-portable extension\f[R].
959 This is a \f[B]non\-portable extension\f[R].
968 This is a \f[B]non\-portable extension\f[R].
981 \f[B]0\f[R] in the top item) when dc(1) starts, dc(1) requires that each
982 register\[cq]s stack must always have at least one item; dc(1) will give
986 This is a \f[B]non\-portable extension\f[R].
1005 This is a \f[B]non\-portable extension\f[R].
1027 been enabled with the \f[B]\-z\f[R] or \f[B]\-\-leading\-zeroes\f[R]
1028 options (see the \f[B]OPTIONS\f[R] section), non\-zero otherwise.
1039 In non\-extended register mode, a register name is just the single
1045 Unlike most other dc(1) implentations, this dc(1) provides nearly
1048 If extended register mode is enabled (\f[B]\-x\f[R] or
1049 \f[B]\-\-extended\-register\f[R] command\-line arguments are given),
1056 \f[B][a\-z][a\-z0\-9_]*\f[R] (like bc(1) identifiers), and it is a parse
1057 error if the next non\-space characters do not match that regex.
1059 When dc(1) encounters an error or a signal that it has a non\-default
1072 Thus, when dc(1) resets, it skips any remaining code waiting to be
1078 Most dc(1) implementations use \f[B]char\f[R] types to calculate the
1080 This dc(1) does something different.
1092 In addition, this dc(1) uses an even larger integer for overflow
1097 The following are the limits on dc(1):
1126 Set at \f[B]SIZE_MAX\-1\f[R].
1130 Set at \f[B]DC_OVERFLOW_MAX\-1\f[R].
1134 Set at \f[B]DC_OVERFLOW_MAX\-1\f[R].
1138 Set at \f[B]DC_OVERFLOW_MAX\-1\f[R].
1143 Set at \f[B]DC_OVERFLOW_MAX\-1\f[R].
1151 Set at \f[B]SIZE_MAX\-1\f[R].
1153 These limits are meant to be effectively non\-existent; the limits are
1154 so large (at least on 64\-bit machines) that there should not be any
1158 As \f[B]non\-portable extensions\f[R], dc(1) recognizes the following
1162 This is another way to give command\-line arguments to dc(1).
1163 They should be in the same format as all other command\-line arguments.
1166 on the command\-line.
1170 functions that the user might want every time dc(1) runs.
1171 Another use would be to use the \f[B]\-e\f[R] option to set
1177 For example, the string \f[B]\[lq]/home/gavin/some dc file.dc\[rq]\f[R]
1179 \[dq]dc\[dq] file.dc\[rq]\f[R] will include the backslashes.
1185 `dc' file.dc\[rq]\f[R], and vice versa if you have a file with double
1189 parsing, though such files are still supported on the command\-line
1196 (\f[B]2\[ha]16\-1\f[R]), dc(1) will output lines to that length,
1201 The special value of \f[B]0\f[R] will disable line length checking and
1207 If dc(1) is not in interactive mode (see the \f[B]INTERACTIVE MODE\f[R]
1208 section), then this environment variable has no effect because dc(1)
1212 However, when dc(1) is in interactive mode, then if this environment
1213 variable exists and contains an integer, a non\-zero value makes dc(1)
1214 reset on \f[B]SIGINT\f[R], rather than exit, and zero makes dc(1) exit.
1216 then dc(1) will exit on \f[B]SIGINT\f[R].
1219 with the \f[B]\-h\f[R] or \f[B]\-\-help\f[R] options.
1228 exists and contains an integer, then a non\-zero value makes dc(1) use
1229 TTY mode, and zero makes dc(1) not use TTY mode.
1232 with the \f[B]\-h\f[R] or \f[B]\-\-help\f[R] options.
1241 exists and contains an integer, a non\-zero value makes dc(1) use a
1242 prompt, and zero or a non\-integer makes dc(1) not use a prompt.
1249 \f[B]\-h\f[R] or \f[B]\-\-help\f[R] options.
1253 If any expressions or expression files are given on the command\-line
1254 with \f[B]\-e\f[R], \f[B]\-\-expression\f[R], \f[B]\-f\f[R], or
1255 \f[B]\-\-file\f[R], then if this environment variable exists and
1256 contains an integer, a non\-zero value makes dc(1) exit after executing
1257 the expressions and expression files, and a zero value makes dc(1) not
1262 with the \f[B]\-h\f[R] or \f[B]\-\-help\f[R] options.
1267 contains an integer, a non\-zero value makes dc(1) clamp digits that are
1274 This never applies to single\-digit numbers, as per the bc(1) standard
1278 with the \f[B]\-h\f[R] or \f[B]\-\-help\f[R] options.
1296 non\-integer where an integer is required.
1329 characters (dc(1) only accepts ASCII characters), attempting to open a
1330 directory as a file, and giving invalid command\-line options.
1333 The exit status \f[B]4\f[R] is special; when a fatal error occurs, dc(1)
1334 always exits and returns \f[B]4\f[R], no matter what mode dc(1) is in.
1336 The other statuses will only be returned when dc(1) is not in
1341 \f[B]\-i\f[R] flag or \f[B]\-\-interactive\f[R] option.
1343 These exit statuses allow dc(1) to be used in shell scripting with error
1345 \f[B]\-i\f[R] flag or \f[B]\-\-interactive\f[R] option.
1347 Like bc(1), dc(1) has an interactive mode and a non\-interactive mode.
1349 and \f[B]stdout\f[R] are hooked to a terminal, but the \f[B]\-i\f[R]
1350 flag and \f[B]\-\-interactive\f[R] option can turn it on in other
1353 In interactive mode, dc(1) attempts to recover from errors (see the
1362 available, and thus, dc(1) can turn on TTY mode, subject to some
1367 that environment variable contains a non\-zero integer, dc(1) will turn
1371 \f[I]not\f[R] a non\-zero integer, then dc(1) will not turn TTY mode on.
1375 The default setting can be queried with the \f[B]\-h\f[R] or
1376 \f[B]\-\-help\f[R] options.
1382 .SS Command\-Line History
1383 Command\-line history is only enabled if TTY mode is, i.e., that
1386 \f[B]ENVIRONMENT VARIABLES\f[R] section) and its default do not disable
1396 non\-zero integer, then the prompt is turned on when \f[B]stdin\f[R],
1398 \f[B]\-P\f[R] and \f[B]\-\-no\-prompt\f[R] options were not used.
1400 the \f[B]\-R\f[R] and \f[B]\-\-no\-read\-prompt\f[R] options must also
1405 the \f[B]\-P\f[R] and \f[B]\-\-no\-prompt\f[R] options, and the
1406 \f[B]\-R\f[R] and \f[B]\-\-no\-read\-prompt\f[R] options.
1410 Sending a \f[B]SIGINT\f[R] will cause dc(1) to do one of two things.
1412 If dc(1) is not in interactive mode (see the \f[B]INTERACTIVE MODE\f[R]
1415 an integer or it is zero, dc(1) will exit.
1417 However, if dc(1) is in interactive mode, and the
1418 \f[B]DC_SIGINT_RESET\f[R] or its default is an integer and non\-zero,
1419 then dc(1) will stop executing the current input and reset (see the
1423 If dc(1) is processing input from \f[B]stdin\f[R] in interactive mode,
1425 If dc(1) is processing input from a file in interactive mode, it will
1429 This means that if a \f[B]SIGINT\f[R] is sent to dc(1) as it is
1430 executing a file, it can seem as though dc(1) did not respond to the
1438 \f[B]SIGTERM\f[R] and \f[B]SIGQUIT\f[R] cause dc(1) to clean up and
1440 The one exception is \f[B]SIGHUP\f[R]; in that case, and only when dc(1)
1442 will cause dc(1) to clean up and exit.
1444 dc(1) supports interactive command\-line editing.
1446 If dc(1) can be in TTY mode (see the \f[B]TTY MODE\f[R] section),
1448 This means that command\-line history can only be enabled when
1460 The dc(1) utility operators and some behavior are compliant with the
1461 operators in the IEEE Std 1003.1\-2017 (\[lq]POSIX.1\-2017\[rq]) bc(1)