xref: /titanic_52/usr/src/cmd/fm/dicts/SUN4U.po (revision 9dd0f810214fdc8e1af881a9a5c4b6927629ff9e)
17c478bd9Sstevel@tonic-gate#
225cf1a30Sjl139090# Copyright 2006 Sun Microsystems, Inc.  All rights reserved.
37c478bd9Sstevel@tonic-gate# Use is subject to license terms.
47c478bd9Sstevel@tonic-gate#
57c478bd9Sstevel@tonic-gate# CDDL HEADER START
67c478bd9Sstevel@tonic-gate#
77c478bd9Sstevel@tonic-gate# The contents of this file are subject to the terms of the
825cf1a30Sjl139090# Common Development and Distribution License (the "License").
925cf1a30Sjl139090# You may not use this file except in compliance with the License.
107c478bd9Sstevel@tonic-gate#
117c478bd9Sstevel@tonic-gate# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
127c478bd9Sstevel@tonic-gate# or http://www.opensolaris.org/os/licensing.
137c478bd9Sstevel@tonic-gate# See the License for the specific language governing permissions
147c478bd9Sstevel@tonic-gate# and limitations under the License.
157c478bd9Sstevel@tonic-gate#
167c478bd9Sstevel@tonic-gate# When distributing Covered Code, include this CDDL HEADER in each
177c478bd9Sstevel@tonic-gate# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
187c478bd9Sstevel@tonic-gate# If applicable, add the following below this CDDL HEADER, with the
197c478bd9Sstevel@tonic-gate# fields enclosed by brackets "[]" replaced with your own identifying
207c478bd9Sstevel@tonic-gate# information: Portions Copyright [yyyy] [name of copyright owner]
217c478bd9Sstevel@tonic-gate#
227c478bd9Sstevel@tonic-gate# CDDL HEADER END
237c478bd9Sstevel@tonic-gate#
247c478bd9Sstevel@tonic-gate#ident	"%Z%%M%	%I%	%E% SMI"
2525cf1a30Sjl139090#
2625cf1a30Sjl139090# DO NOT EDIT -- this file is generated by the Event Registry.
2725cf1a30Sjl139090#
287c478bd9Sstevel@tonic-gate#
297c478bd9Sstevel@tonic-gate# code: SUN4U-8000-1A
307c478bd9Sstevel@tonic-gate# keys: fault.memory.page
317c478bd9Sstevel@tonic-gate#
327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.type"
337c478bd9Sstevel@tonic-gatemsgstr "Fault"
347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.severity"
357c478bd9Sstevel@tonic-gatemsgstr "Minor"
367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.description"
377c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this memory module continues to exceed acceptable levels.  Refer to %s for more information."
387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.response"
397c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove this memory page from service."
407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.impact"
417c478bd9Sstevel@tonic-gatemsgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.action"
437c478bd9Sstevel@tonic-gatemsgstr "No repair action is recommended at this time."
447c478bd9Sstevel@tonic-gate#
457c478bd9Sstevel@tonic-gate# code: SUN4U-8000-2S
467c478bd9Sstevel@tonic-gate# keys: fault.memory.dimm
477c478bd9Sstevel@tonic-gate#
487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.type"
497c478bd9Sstevel@tonic-gatemsgstr "Fault"
507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.severity"
5125cf1a30Sjl139090msgstr "Major"
527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.description"
537c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.response"
557c478bd9Sstevel@tonic-gatemsgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.impact"
577c478bd9Sstevel@tonic-gatemsgstr "Total system memory capacity will be reduced as pages are retired."
587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.action"
597c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
607c478bd9Sstevel@tonic-gate#
617c478bd9Sstevel@tonic-gate# code: SUN4U-8000-35
627c478bd9Sstevel@tonic-gate# keys: fault.memory.bank
637c478bd9Sstevel@tonic-gate#
647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.type"
657c478bd9Sstevel@tonic-gatemsgstr "Fault"
667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.severity"
6725cf1a30Sjl139090msgstr "Critical"
687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.description"
697c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.response"
717c478bd9Sstevel@tonic-gatemsgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.impact"
737c478bd9Sstevel@tonic-gatemsgstr "Total system memory capacity will be reduced as pages are retired."
747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.action"
757c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
767c478bd9Sstevel@tonic-gate#
777c478bd9Sstevel@tonic-gate# code: SUN4U-8000-4Y
787c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.dcache
797c478bd9Sstevel@tonic-gate#
807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.type"
817c478bd9Sstevel@tonic-gatemsgstr "Fault"
827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.severity"
837c478bd9Sstevel@tonic-gatemsgstr "Major"
847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.description"
8525cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.response"
8725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.impact"
8925cf1a30Sjl139090msgstr "System performance may be affected."
907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.action"
9125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
927c478bd9Sstevel@tonic-gate#
937c478bd9Sstevel@tonic-gate# code: SUN4U-8000-53
947c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.icache
957c478bd9Sstevel@tonic-gate#
967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.type"
977c478bd9Sstevel@tonic-gatemsgstr "Fault"
987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.severity"
997c478bd9Sstevel@tonic-gatemsgstr "Major"
1007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.description"
10125cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
1027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.response"
10325cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
1047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.impact"
10525cf1a30Sjl139090msgstr "System performance may be affected."
1067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.action"
10725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
1087c478bd9Sstevel@tonic-gate#
1097c478bd9Sstevel@tonic-gate# code: SUN4U-8000-6H
1107c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.l2cachedata
1117c478bd9Sstevel@tonic-gate#
1127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.type"
1137c478bd9Sstevel@tonic-gatemsgstr "Fault"
1147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.severity"
1157c478bd9Sstevel@tonic-gatemsgstr "Major"
1167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.description"
1177c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
1187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.response"
11925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
1207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.impact"
12125cf1a30Sjl139090msgstr "System performance may be affected."
1227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.action"
12325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
1247c478bd9Sstevel@tonic-gate#
1257c478bd9Sstevel@tonic-gate# code: SUN4U-8000-7D
1267c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.l2cachetag
1277c478bd9Sstevel@tonic-gate#
1287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.type"
1297c478bd9Sstevel@tonic-gatemsgstr "Fault"
1307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.severity"
1317c478bd9Sstevel@tonic-gatemsgstr "Major"
1327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.description"
1337c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
1347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.response"
13525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
1367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.impact"
13725cf1a30Sjl139090msgstr "System performance may be affected."
1387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.action"
13925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
1407c478bd9Sstevel@tonic-gate#
1417c478bd9Sstevel@tonic-gate# code: SUN4U-8000-84
1427c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.dcache
1437c478bd9Sstevel@tonic-gate#
1447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.type"
1457c478bd9Sstevel@tonic-gatemsgstr "Fault"
1467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.severity"
1477c478bd9Sstevel@tonic-gatemsgstr "Major"
1487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.description"
1497c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
1507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.response"
15125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
1527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.impact"
15325cf1a30Sjl139090msgstr "System performance system may be affected."
1547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.action"
15525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
1567c478bd9Sstevel@tonic-gate#
1577c478bd9Sstevel@tonic-gate# code: SUN4U-8000-9R
1587c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.icache
1597c478bd9Sstevel@tonic-gate#
1607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.type"
1617c478bd9Sstevel@tonic-gatemsgstr "Fault"
1627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.severity"
1637c478bd9Sstevel@tonic-gatemsgstr "Major"
1647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.description"
1657c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
1667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.response"
16725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
1687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.impact"
16925cf1a30Sjl139090msgstr "System performance may be affected."
1707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.action"
17125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
1727c478bd9Sstevel@tonic-gate#
1737c478bd9Sstevel@tonic-gate# code: SUN4U-8000-AC
1747c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.l2cachedata
1757c478bd9Sstevel@tonic-gate#
1767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.type"
1777c478bd9Sstevel@tonic-gatemsgstr "Fault"
1787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.severity"
1797c478bd9Sstevel@tonic-gatemsgstr "Major"
1807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.description"
1817c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
1827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.response"
18325cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
1847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.impact"
18525cf1a30Sjl139090msgstr "System performance may be affected."
1867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.action"
18725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
1887c478bd9Sstevel@tonic-gate#
1897c478bd9Sstevel@tonic-gate# code: SUN4U-8000-CQ
1907c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.l2cachetag
1917c478bd9Sstevel@tonic-gate#
1927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.type"
1937c478bd9Sstevel@tonic-gatemsgstr "Fault"
1947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.severity"
1957c478bd9Sstevel@tonic-gatemsgstr "Major"
1967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.description"
1977c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
1987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.response"
19925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
2007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.impact"
20125cf1a30Sjl139090msgstr "System performance may be affected."
2027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.action"
20325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
2047c478bd9Sstevel@tonic-gate#
2057c478bd9Sstevel@tonic-gate# code: SUN4U-8000-DE
2067c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.dcache
2077c478bd9Sstevel@tonic-gate#
2087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.type"
2097c478bd9Sstevel@tonic-gatemsgstr "Fault"
2107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.severity"
2117c478bd9Sstevel@tonic-gatemsgstr "Major"
2127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.description"
2137c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
2147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.response"
21525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
2167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.impact"
21725cf1a30Sjl139090msgstr "System performance may be affected."
2187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.action"
21925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
2207c478bd9Sstevel@tonic-gate#
2217c478bd9Sstevel@tonic-gate# code: SUN4U-8000-EJ
2227c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.icache
2237c478bd9Sstevel@tonic-gate#
2247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.type"
2257c478bd9Sstevel@tonic-gatemsgstr "Fault"
2267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.severity"
2277c478bd9Sstevel@tonic-gatemsgstr "Major"
2287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.description"
2297c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
2307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.response"
23125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
2327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.impact"
23325cf1a30Sjl139090msgstr "System performance may be affected."
2347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.action"
23525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
2367c478bd9Sstevel@tonic-gate#
2377c478bd9Sstevel@tonic-gate# code: SUN4U-8000-F2
2387c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.l2cachedata
2397c478bd9Sstevel@tonic-gate#
2407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.type"
2417c478bd9Sstevel@tonic-gatemsgstr "Fault"
2427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.severity"
2437c478bd9Sstevel@tonic-gatemsgstr "Major"
2447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.description"
2457c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
2467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.response"
24725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
2487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.impact"
24925cf1a30Sjl139090msgstr "System performance may be affected."
2507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.action"
25125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
2527c478bd9Sstevel@tonic-gate#
2537c478bd9Sstevel@tonic-gate# code: SUN4U-8000-GX
2547c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.l2cachetag
2557c478bd9Sstevel@tonic-gate#
2567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.type"
2577c478bd9Sstevel@tonic-gatemsgstr "Fault"
2587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.severity"
2597c478bd9Sstevel@tonic-gatemsgstr "Major"
2607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.description"
2617c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
2627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.response"
2637c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service."
2647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.impact"
26525cf1a30Sjl139090msgstr "System performance may be affected."
2667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.action"
2677c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u <EVENT_ID> to identify the CPU."
2687c478bd9Sstevel@tonic-gate#
2697c478bd9Sstevel@tonic-gate# code: SUN4U-8000-H5
2707c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.dcache
2717c478bd9Sstevel@tonic-gate#
2727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.type"
2737c478bd9Sstevel@tonic-gatemsgstr "Fault"
2747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.severity"
2757c478bd9Sstevel@tonic-gatemsgstr "Major"
2767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.description"
2777c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
2787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.response"
27925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
2807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.impact"
28125cf1a30Sjl139090msgstr "System performance may be affected."
2827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.action"
28325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
2847c478bd9Sstevel@tonic-gate#
2857c478bd9Sstevel@tonic-gate# code: SUN4U-8000-JS
2867c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.icache
2877c478bd9Sstevel@tonic-gate#
2887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.type"
2897c478bd9Sstevel@tonic-gatemsgstr "Fault"
2907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.severity"
2917c478bd9Sstevel@tonic-gatemsgstr "Major"
2927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.description"
2937c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
2947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.response"
29525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
2967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.impact"
29725cf1a30Sjl139090msgstr "System performance may be affected."
2987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.action"
29925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3007c478bd9Sstevel@tonic-gate#
3017c478bd9Sstevel@tonic-gate# code: SUN4U-8000-KA
3027c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.l2cachedata
3037c478bd9Sstevel@tonic-gate#
3047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.type"
3057c478bd9Sstevel@tonic-gatemsgstr "Fault"
3067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.severity"
3077c478bd9Sstevel@tonic-gatemsgstr "Major"
3087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.description"
3097c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
3107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.response"
31125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
3127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.impact"
31325cf1a30Sjl139090msgstr "System performance may be affected."
3147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.action"
31525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3167c478bd9Sstevel@tonic-gate#
3177c478bd9Sstevel@tonic-gate# code: SUN4U-8000-LP
3187c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.l2cachetag
3197c478bd9Sstevel@tonic-gate#
3207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.type"
3217c478bd9Sstevel@tonic-gatemsgstr "Fault"
3227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.severity"
3237c478bd9Sstevel@tonic-gatemsgstr "Major"
3247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.description"
3257c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
3267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.response"
32725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
3287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.impact"
32925cf1a30Sjl139090msgstr "System performance may be affected."
3307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.action"
33125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3327c478bd9Sstevel@tonic-gate#
3337c478bd9Sstevel@tonic-gate# code: SUN4U-8000-MD
3347c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.fpu
3357c478bd9Sstevel@tonic-gate#
3367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.type"
3377c478bd9Sstevel@tonic-gatemsgstr "Fault"
3387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.severity"
3397c478bd9Sstevel@tonic-gatemsgstr "Major"
3407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.description"
3417c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
3427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.response"
34325cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
3447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.impact"
34525cf1a30Sjl139090msgstr "System performance may be affected."
3467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.action"
34725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3487c478bd9Sstevel@tonic-gate#
3497c478bd9Sstevel@tonic-gate# code: SUN4U-8000-NH
3507c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.fpu
3517c478bd9Sstevel@tonic-gate#
3527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.type"
3537c478bd9Sstevel@tonic-gatemsgstr "Fault"
3547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.severity"
3557c478bd9Sstevel@tonic-gatemsgstr "Major"
3567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.description"
3577c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
3587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.response"
35925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
3607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.impact"
36125cf1a30Sjl139090msgstr "System performance may be affected."
3627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.action"
36325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3647c478bd9Sstevel@tonic-gate#
3657c478bd9Sstevel@tonic-gate# code: SUN4U-8000-P3
3667c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.fpu
3677c478bd9Sstevel@tonic-gate#
3687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.type"
3697c478bd9Sstevel@tonic-gatemsgstr "Fault"
3707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.severity"
3717c478bd9Sstevel@tonic-gatemsgstr "Major"
3727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.description"
3737c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
3747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.response"
37525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
3767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.impact"
37725cf1a30Sjl139090msgstr "System performance may be affected."
3787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.action"
37925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3807c478bd9Sstevel@tonic-gate#
3817c478bd9Sstevel@tonic-gate# code: SUN4U-8000-QY
3827c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.fpu
3837c478bd9Sstevel@tonic-gate#
3847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.type"
3857c478bd9Sstevel@tonic-gatemsgstr "Fault"
3867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.severity"
3877c478bd9Sstevel@tonic-gatemsgstr "Major"
3887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.description"
3897c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
3907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.response"
39125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
3927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.impact"
39325cf1a30Sjl139090msgstr "System performance may be affected."
3947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.action"
39525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3967c478bd9Sstevel@tonic-gate#
3977c478bd9Sstevel@tonic-gate# code: SUN4U-8000-RQ
3987c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.fpu
3997c478bd9Sstevel@tonic-gate#
4007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.type"
4017c478bd9Sstevel@tonic-gatemsgstr "Fault"
4027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.severity"
4037c478bd9Sstevel@tonic-gatemsgstr "Major"
4047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.description"
4057c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU.  Refer to %s for more information."
4067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.response"
40725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
4087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.impact"
40925cf1a30Sjl139090msgstr "System performance may be affected."
4107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.action"
41125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
4127c478bd9Sstevel@tonic-gate#
4137c478bd9Sstevel@tonic-gate# code: SUN4U-8000-SC
4147c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.dcache
4157c478bd9Sstevel@tonic-gate#
4167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.type"
4177c478bd9Sstevel@tonic-gatemsgstr "Fault"
4187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.severity"
4197c478bd9Sstevel@tonic-gatemsgstr "Major"
4207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.description"
4217c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
4227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.response"
42325cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
4247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.impact"
42525cf1a30Sjl139090msgstr "System performance may be affected."
4267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.action"
42725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
4287c478bd9Sstevel@tonic-gate#
4297c478bd9Sstevel@tonic-gate# code: SUN4U-8000-TR
4307c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.icache
4317c478bd9Sstevel@tonic-gate#
4327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.type"
4337c478bd9Sstevel@tonic-gatemsgstr "Fault"
4347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.severity"
4357c478bd9Sstevel@tonic-gatemsgstr "Major"
4367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.description"
4377c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
4387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.response"
43925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
4407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.impact"
44125cf1a30Sjl139090msgstr "System performance may be affected."
4427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.action"
44325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
4447c478bd9Sstevel@tonic-gate#
4457c478bd9Sstevel@tonic-gate# code: SUN4U-8000-U4
4467c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.pcache
4477c478bd9Sstevel@tonic-gate#
4487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.type"
4497c478bd9Sstevel@tonic-gatemsgstr "Fault"
4507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.severity"
4517c478bd9Sstevel@tonic-gatemsgstr "Major"
4527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.description"
4537c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
4547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.response"
45525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
4567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.impact"
45725cf1a30Sjl139090msgstr "System performance may be affected."
4587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.action"
45925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
4607c478bd9Sstevel@tonic-gate#
4617c478bd9Sstevel@tonic-gate# code: SUN4U-8000-VX
4627c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.dtlb
4637c478bd9Sstevel@tonic-gate#
4647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.type"
4657c478bd9Sstevel@tonic-gatemsgstr "Fault"
4667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.severity"
4677c478bd9Sstevel@tonic-gatemsgstr "Major"
4687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.description"
4697c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
4707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.response"
47125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
4727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.impact"
47325cf1a30Sjl139090msgstr "System performance may be affected."
4747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.action"
47525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
4767c478bd9Sstevel@tonic-gate#
4777c478bd9Sstevel@tonic-gate# code: SUN4U-8000-W2
4787c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.itlb
4797c478bd9Sstevel@tonic-gate#
4807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.type"
4817c478bd9Sstevel@tonic-gatemsgstr "Fault"
4827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.severity"
4837c478bd9Sstevel@tonic-gatemsgstr "Major"
4847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.description"
4857c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
4867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.response"
48725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
4887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.impact"
48925cf1a30Sjl139090msgstr "System performance may be affected."
4907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.action"
49125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
4927c478bd9Sstevel@tonic-gate#
4937c478bd9Sstevel@tonic-gate# code: SUN4U-8000-XJ
4947c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.l2cachedata
4957c478bd9Sstevel@tonic-gate#
4967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.type"
4977c478bd9Sstevel@tonic-gatemsgstr "Fault"
4987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.severity"
4997c478bd9Sstevel@tonic-gatemsgstr "Major"
5007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.description"
5017c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
5027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.response"
50325cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
5047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.impact"
50525cf1a30Sjl139090msgstr "System performance may be affected."
5067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.action"
50725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
5087c478bd9Sstevel@tonic-gate#
5097c478bd9Sstevel@tonic-gate# code: SUN4U-8000-YE
5107c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.l2cachetag
5117c478bd9Sstevel@tonic-gate#
5127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.type"
5137c478bd9Sstevel@tonic-gatemsgstr "Fault"
5147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.severity"
5157c478bd9Sstevel@tonic-gatemsgstr "Major"
5167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.description"
5177c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
5187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.response"
51925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
5207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.impact"
52125cf1a30Sjl139090msgstr "System performance may be affected."
5227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.action"
52325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
5247c478bd9Sstevel@tonic-gate#
5257c478bd9Sstevel@tonic-gate# code: SUN4U-8001-0J
5267c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.l3cachedata
5277c478bd9Sstevel@tonic-gate#
5287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.type"
5297c478bd9Sstevel@tonic-gatemsgstr "Fault"
5307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.severity"
5317c478bd9Sstevel@tonic-gatemsgstr "Major"
5327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.description"
5337c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
5347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.response"
53525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
5367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.impact"
53725cf1a30Sjl139090msgstr "System performance may be affected."
5387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.action"
53925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
5407c478bd9Sstevel@tonic-gate#
5417c478bd9Sstevel@tonic-gate# code: SUN4U-8001-1E
5427c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.l3cachetag
5437c478bd9Sstevel@tonic-gate#
5447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.type"
5457c478bd9Sstevel@tonic-gatemsgstr "Fault"
5467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.severity"
5477c478bd9Sstevel@tonic-gatemsgstr "Major"
5487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.description"
5497c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels.  Refer to %s for more information."
5507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.response"
55125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
5527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.impact"
55325cf1a30Sjl139090msgstr "System performance may be affected."
5547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.action"
55525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
5567c478bd9Sstevel@tonic-gate#
5577c478bd9Sstevel@tonic-gate# code: SUN4U-8001-2X
5587c478bd9Sstevel@tonic-gate# keys: defect.ultraSPARC-II.memory.nodiag
5597c478bd9Sstevel@tonic-gate#
5607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.type"
5617c478bd9Sstevel@tonic-gatemsgstr "Defect"
5627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.severity"
5637c478bd9Sstevel@tonic-gatemsgstr "Minor"
5647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.description"
56525cf1a30Sjl139090msgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable.  Refer to %s for more information."
5667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.response"
5677c478bd9Sstevel@tonic-gatemsgstr "The error information has been saved for examination by Sun."
5687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.impact"
5697c478bd9Sstevel@tonic-gatemsgstr "The error log will need to be manually examined using fmdump(1M) in order to determine if any human response is required."
5707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.action"
5717c478bd9Sstevel@tonic-gatemsgstr "Use fmdump -ev -u <EVENT-ID> to view and record the undiagnosed errors."
5727c478bd9Sstevel@tonic-gate#
5737c478bd9Sstevel@tonic-gate# code: SUN4U-8001-32
5747c478bd9Sstevel@tonic-gate# keys: fault.memory.datapath
5757c478bd9Sstevel@tonic-gate#
5767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.type"
5777c478bd9Sstevel@tonic-gatemsgstr "Fault"
5787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.severity"
5797c478bd9Sstevel@tonic-gatemsgstr "Major"
5807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.description"
5817c478bd9Sstevel@tonic-gatemsgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.  Refer to %s for more information."
5827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.response"
5837c478bd9Sstevel@tonic-gatemsgstr "Error reports from the affected components will be logged for examination by Sun."
5847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.impact"
5857c478bd9Sstevel@tonic-gatemsgstr "System performance and stability may be affected."
5867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.action"
5877c478bd9Sstevel@tonic-gatemsgstr "Contact your service provider for further diagnosis."
5887c478bd9Sstevel@tonic-gate#
5897c478bd9Sstevel@tonic-gate# code: SUN4U-8001-4R
5907c478bd9Sstevel@tonic-gate# keys: fault.io.datapath
5917c478bd9Sstevel@tonic-gate#
5927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.type"
5937c478bd9Sstevel@tonic-gatemsgstr "Fault"
5947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.severity"
5957c478bd9Sstevel@tonic-gatemsgstr "Critical"
5967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.description"
59725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
5987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.response"
59925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
6007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.impact"
60125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
6027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.action"
60325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
6047c478bd9Sstevel@tonic-gate#
6057c478bd9Sstevel@tonic-gate# code: SUN4U-8001-54
6067c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath
6077c478bd9Sstevel@tonic-gate#
6087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.type"
6097c478bd9Sstevel@tonic-gatemsgstr "Fault"
6107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.severity"
6117c478bd9Sstevel@tonic-gatemsgstr "Critical"
6127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.description"
61325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
6147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.response"
61525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
6167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.impact"
61725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
6187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.action"
61925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
6207c478bd9Sstevel@tonic-gate#
6217c478bd9Sstevel@tonic-gate# code: SUN4U-8001-6Q
6227c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus
6237c478bd9Sstevel@tonic-gate#
6247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.type"
6257c478bd9Sstevel@tonic-gatemsgstr "Fault"
6267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.severity"
6277c478bd9Sstevel@tonic-gatemsgstr "Critical"
6287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.description"
62925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
6307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.response"
63125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
6327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.impact"
63325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
6347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.action"
63525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
6367c478bd9Sstevel@tonic-gate#
6377c478bd9Sstevel@tonic-gate# code: SUN4U-8001-7C
6387c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus
6397c478bd9Sstevel@tonic-gate#
6407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.type"
6417c478bd9Sstevel@tonic-gatemsgstr "Fault"
6427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.severity"
6437c478bd9Sstevel@tonic-gatemsgstr "Critical"
6447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.description"
64525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
6467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.response"
64725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
6487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.impact"
64925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
6507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.action"
65125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
6527c478bd9Sstevel@tonic-gate#
6537c478bd9Sstevel@tonic-gate# code: SUN4U-8001-83
6547c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device
6557c478bd9Sstevel@tonic-gate#
6567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.type"
6577c478bd9Sstevel@tonic-gatemsgstr "Fault"
6587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.severity"
6597c478bd9Sstevel@tonic-gatemsgstr "Critical"
6607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.description"
66125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
6627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.response"
66325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
6647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.impact"
66525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
6667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.action"
66725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
6687c478bd9Sstevel@tonic-gate#
6697c478bd9Sstevel@tonic-gate# code: SUN4U-8001-9Y
6707c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device
6717c478bd9Sstevel@tonic-gate#
6727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.type"
6737c478bd9Sstevel@tonic-gatemsgstr "Fault"
6747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.severity"
6757c478bd9Sstevel@tonic-gatemsgstr "Critical"
6767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.description"
67725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
6787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.response"
67925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
6807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.impact"
68125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
6827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.action"
68325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
6847c478bd9Sstevel@tonic-gate#
6857c478bd9Sstevel@tonic-gate# code: SUN4U-8001-AD
6867c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device
6877c478bd9Sstevel@tonic-gate#
6887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.type"
6897c478bd9Sstevel@tonic-gatemsgstr "Fault"
6907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.severity"
6917c478bd9Sstevel@tonic-gatemsgstr "Critical"
6927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.description"
69325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
6947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.response"
69525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
6967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.impact"
69725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
6987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.action"
69925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
7007c478bd9Sstevel@tonic-gate#
7017c478bd9Sstevel@tonic-gate# code: SUN4U-8001-CH
7027c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device
7037c478bd9Sstevel@tonic-gate#
7047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.type"
7057c478bd9Sstevel@tonic-gatemsgstr "Fault"
7067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.severity"
7077c478bd9Sstevel@tonic-gatemsgstr "Critical"
7087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.description"
70925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
7107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.response"
71125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
7127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.impact"
71325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
7147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.action"
71525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
7167c478bd9Sstevel@tonic-gate#
7177c478bd9Sstevel@tonic-gate# code: SUN4U-8001-DA
7187c478bd9Sstevel@tonic-gate# keys: fault.io.hbus
7197c478bd9Sstevel@tonic-gate#
7207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.type"
7217c478bd9Sstevel@tonic-gatemsgstr "Fault"
7227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.severity"
7237c478bd9Sstevel@tonic-gatemsgstr "Critical"
7247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.description"
72525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
7267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.response"
72725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
7287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.impact"
72925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
7307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.action"
73125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
7327c478bd9Sstevel@tonic-gate#
7337c478bd9Sstevel@tonic-gate# code: SUN4U-8001-EP
7347c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus
7357c478bd9Sstevel@tonic-gate#
7367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.type"
7377c478bd9Sstevel@tonic-gatemsgstr "Fault"
7387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.severity"
7397c478bd9Sstevel@tonic-gatemsgstr "Critical"
7407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.description"
74125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
7427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.response"
74325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
7447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.impact"
74525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
7467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.action"
74725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
7487c478bd9Sstevel@tonic-gate#
7497c478bd9Sstevel@tonic-gate# code: SUN4U-8001-F5
7507c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus
7517c478bd9Sstevel@tonic-gate#
7527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.type"
7537c478bd9Sstevel@tonic-gatemsgstr "Fault"
7547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.severity"
7557c478bd9Sstevel@tonic-gatemsgstr "Critical"
7567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.description"
75725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
7587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.response"
75925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
7607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.impact"
76125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
7627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.action"
76325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
7647c478bd9Sstevel@tonic-gate#
7657c478bd9Sstevel@tonic-gate# code: SUN4U-8001-GS
7667c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus
7677c478bd9Sstevel@tonic-gate#
7687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.type"
7697c478bd9Sstevel@tonic-gatemsgstr "Fault"
7707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.severity"
7717c478bd9Sstevel@tonic-gatemsgstr "Critical"
7727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.description"
77325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
7747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.response"
77525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
7767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.impact"
77725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
7787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.action"
77925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
7807c478bd9Sstevel@tonic-gate#
7817c478bd9Sstevel@tonic-gate# code: SUN4U-8001-H2
7827c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device
7837c478bd9Sstevel@tonic-gate#
7847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.type"
7857c478bd9Sstevel@tonic-gatemsgstr "Fault"
7867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.severity"
7877c478bd9Sstevel@tonic-gatemsgstr "Critical"
7887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.description"
78925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
7907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.response"
79125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
7927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.impact"
79325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
7947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.action"
79525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
7967c478bd9Sstevel@tonic-gate#
7977c478bd9Sstevel@tonic-gate# code: SUN4U-8001-JX
7987c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device
7997c478bd9Sstevel@tonic-gate#
8007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.type"
8017c478bd9Sstevel@tonic-gatemsgstr "Fault"
8027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.severity"
8037c478bd9Sstevel@tonic-gatemsgstr "Critical"
8047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.description"
80525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
8067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.response"
80725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
8087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.impact"
80925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
8107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.action"
81125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
8127c478bd9Sstevel@tonic-gate#
8137c478bd9Sstevel@tonic-gate# code: SUN4U-8001-KE
8147c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device
8157c478bd9Sstevel@tonic-gate#
8167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.type"
8177c478bd9Sstevel@tonic-gatemsgstr "Fault"
8187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.severity"
8197c478bd9Sstevel@tonic-gatemsgstr "Critical"
8207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.description"
82125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
8227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.response"
82325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
8247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.impact"
82525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
8267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.action"
82725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
8287c478bd9Sstevel@tonic-gate#
8297c478bd9Sstevel@tonic-gate# code: SUN4U-8001-LJ
8307c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device
8317c478bd9Sstevel@tonic-gate#
8327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.type"
8337c478bd9Sstevel@tonic-gatemsgstr "Fault"
8347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.severity"
8357c478bd9Sstevel@tonic-gatemsgstr "Critical"
8367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.description"
83725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
8387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.response"
83925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
8407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.impact"
84125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
8427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.action"
84325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
8447c478bd9Sstevel@tonic-gate#
8457c478bd9Sstevel@tonic-gate# code: SUN4U-8001-MC
8467c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus
8477c478bd9Sstevel@tonic-gate#
8487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.type"
8497c478bd9Sstevel@tonic-gatemsgstr "Fault"
8507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.severity"
8517c478bd9Sstevel@tonic-gatemsgstr "Critical"
8527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.description"
85325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
8547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.response"
85525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
8567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.impact"
85725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
8587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.action"
85925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
8607c478bd9Sstevel@tonic-gate#
8617c478bd9Sstevel@tonic-gate# code: SUN4U-8001-NQ
8627c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus
8637c478bd9Sstevel@tonic-gate#
8647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.type"
8657c478bd9Sstevel@tonic-gatemsgstr "Fault"
8667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.severity"
8677c478bd9Sstevel@tonic-gatemsgstr "Critical"
8687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.description"
86925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
8707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.response"
87125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
8727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.impact"
87325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
8747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.action"
87525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
8767c478bd9Sstevel@tonic-gate#
8777c478bd9Sstevel@tonic-gate# code: SUN4U-8001-P4
8787c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus
8797c478bd9Sstevel@tonic-gate#
8807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.type"
8817c478bd9Sstevel@tonic-gatemsgstr "Fault"
8827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.severity"
8837c478bd9Sstevel@tonic-gatemsgstr "Critical"
8847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.description"
88525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
8867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.response"
88725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
8887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.impact"
88925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
8907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.action"
89125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
8927c478bd9Sstevel@tonic-gate#
8937c478bd9Sstevel@tonic-gate# code: SUN4U-8001-QR
8947c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus
8957c478bd9Sstevel@tonic-gate#
8967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.type"
8977c478bd9Sstevel@tonic-gatemsgstr "Fault"
8987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.severity"
8997c478bd9Sstevel@tonic-gatemsgstr "Critical"
9007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.description"
90125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
9027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.response"
90325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
9047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.impact"
90525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
9067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.action"
90725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
9087c478bd9Sstevel@tonic-gate#
9097c478bd9Sstevel@tonic-gate# code: SUN4U-8001-RH
9107c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device
9117c478bd9Sstevel@tonic-gate#
9127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.type"
9137c478bd9Sstevel@tonic-gatemsgstr "Fault"
9147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.severity"
9157c478bd9Sstevel@tonic-gatemsgstr "Critical"
9167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.description"
91725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
9187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.response"
91925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
9207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.impact"
92125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
9227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.action"
92325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
9247c478bd9Sstevel@tonic-gate#
9257c478bd9Sstevel@tonic-gate# code: SUN4U-8001-SD
9267c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device
9277c478bd9Sstevel@tonic-gate#
9287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.type"
9297c478bd9Sstevel@tonic-gatemsgstr "Fault"
9307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.severity"
9317c478bd9Sstevel@tonic-gatemsgstr "Critical"
9327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.description"
93325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
9347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.response"
93525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
9367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.impact"
93725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
9387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.action"
93925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
9407c478bd9Sstevel@tonic-gate#
9417c478bd9Sstevel@tonic-gate# code: SUN4U-8001-TY
9427c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device
9437c478bd9Sstevel@tonic-gate#
9447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.type"
9457c478bd9Sstevel@tonic-gatemsgstr "Fault"
9467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.severity"
9477c478bd9Sstevel@tonic-gatemsgstr "Critical"
9487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.description"
94925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
9507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.response"
95125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
9527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.impact"
95325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
9547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.action"
95525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
9567c478bd9Sstevel@tonic-gate#
9577c478bd9Sstevel@tonic-gate# code: SUN4U-8001-U3
9587c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device
9597c478bd9Sstevel@tonic-gate#
9607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.type"
9617c478bd9Sstevel@tonic-gatemsgstr "Fault"
9627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.severity"
9637c478bd9Sstevel@tonic-gatemsgstr "Critical"
9647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.description"
96525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
9667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.response"
96725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
9687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.impact"
96925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
9707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.action"
97125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
9727c478bd9Sstevel@tonic-gate#
9737c478bd9Sstevel@tonic-gate# code: SUN4U-8001-VS
9747c478bd9Sstevel@tonic-gate# keys: fault.io.schizo
9757c478bd9Sstevel@tonic-gate#
9767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.type"
9777c478bd9Sstevel@tonic-gatemsgstr "Fault"
9787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.severity"
9797c478bd9Sstevel@tonic-gatemsgstr "Critical"
9807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.description"
98125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
9827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.response"
98325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
9847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.impact"
98525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
9867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.action"
98725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
9887c478bd9Sstevel@tonic-gate#
9897c478bd9Sstevel@tonic-gate# code: SUN4U-8001-W5
9907c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.schizo
9917c478bd9Sstevel@tonic-gate#
9927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.type"
9937c478bd9Sstevel@tonic-gatemsgstr "Fault"
9947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.severity"
9957c478bd9Sstevel@tonic-gatemsgstr "Critical"
9967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.description"
99725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
9987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.response"
99925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
10007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.impact"
100125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
10027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.action"
100325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
10047c478bd9Sstevel@tonic-gate#
10057c478bd9Sstevel@tonic-gate# code: SUN4U-8001-XP
10067c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.schizo
10077c478bd9Sstevel@tonic-gate#
10087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.type"
10097c478bd9Sstevel@tonic-gatemsgstr "Fault"
10107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.severity"
10117c478bd9Sstevel@tonic-gatemsgstr "Critical"
10127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.description"
101325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
10147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.response"
101525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
10167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.impact"
101725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
10187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.action"
101925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
10207c478bd9Sstevel@tonic-gate#
10217c478bd9Sstevel@tonic-gate# code: SUN4U-8001-YA
10227c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo
10237c478bd9Sstevel@tonic-gate#
10247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.type"
10257c478bd9Sstevel@tonic-gatemsgstr "Fault"
10267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.severity"
10277c478bd9Sstevel@tonic-gatemsgstr "Critical"
10287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.description"
102925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
10307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.response"
103125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
10327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.impact"
103325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
10347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.action"
103525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
10367c478bd9Sstevel@tonic-gate#
10377c478bd9Sstevel@tonic-gate# code: SUN4U-8002-0R
10387c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.schizo
10397c478bd9Sstevel@tonic-gate#
10407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.type"
10417c478bd9Sstevel@tonic-gatemsgstr "Fault"
10427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.severity"
10437c478bd9Sstevel@tonic-gatemsgstr "Critical"
10447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.description"
104525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
10467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.response"
104725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
10487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.impact"
104925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
10507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.action"
105125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
10527c478bd9Sstevel@tonic-gate#
10537c478bd9Sstevel@tonic-gate# code: SUN4U-8002-14
10547c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo
10557c478bd9Sstevel@tonic-gate#
10567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.type"
10577c478bd9Sstevel@tonic-gatemsgstr "Fault"
10587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.severity"
10597c478bd9Sstevel@tonic-gatemsgstr "Critical"
10607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.description"
106125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
10627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.response"
106325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
10647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.impact"
106525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
10667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.action"
106725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
10687c478bd9Sstevel@tonic-gate#
10697c478bd9Sstevel@tonic-gate# code: SUN4U-8002-2Q
10707c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo
10717c478bd9Sstevel@tonic-gate#
10727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.type"
10737c478bd9Sstevel@tonic-gatemsgstr "Fault"
10747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.severity"
10757c478bd9Sstevel@tonic-gatemsgstr "Critical"
10767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.description"
107725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
10787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.response"
107925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
10807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.impact"
108125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
10827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.action"
108325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
10847c478bd9Sstevel@tonic-gate#
10857c478bd9Sstevel@tonic-gate# code: SUN4U-8002-3C
10867c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo
10877c478bd9Sstevel@tonic-gate#
10887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.type"
10897c478bd9Sstevel@tonic-gatemsgstr "Fault"
10907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.severity"
10917c478bd9Sstevel@tonic-gatemsgstr "Critical"
10927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.description"
109325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
10947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.response"
109525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
10967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.impact"
109725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
10987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.action"
109925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
11007c478bd9Sstevel@tonic-gate#
11017c478bd9Sstevel@tonic-gate# code: SUN4U-8002-4J
11027c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.schizo
11037c478bd9Sstevel@tonic-gate#
11047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.type"
11057c478bd9Sstevel@tonic-gatemsgstr "Fault"
11067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.severity"
11077c478bd9Sstevel@tonic-gatemsgstr "Critical"
11087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.description"
110925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
11107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.response"
111125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
11127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.impact"
111325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
11147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.action"
111525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
11167c478bd9Sstevel@tonic-gate#
11177c478bd9Sstevel@tonic-gate# code: SUN4U-8002-5E
11187c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo
11197c478bd9Sstevel@tonic-gate#
11207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.type"
11217c478bd9Sstevel@tonic-gatemsgstr "Fault"
11227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.severity"
11237c478bd9Sstevel@tonic-gatemsgstr "Critical"
11247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.description"
112525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
11267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.response"
112725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
11287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.impact"
112925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
11307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.action"
113125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
11327c478bd9Sstevel@tonic-gate#
11337c478bd9Sstevel@tonic-gate# code: SUN4U-8002-6X
11347c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo
11357c478bd9Sstevel@tonic-gate#
11367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.type"
11377c478bd9Sstevel@tonic-gatemsgstr "Fault"
11387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.severity"
11397c478bd9Sstevel@tonic-gatemsgstr "Critical"
11407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.description"
114125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
11427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.response"
114325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
11447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.impact"
114525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
11467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.action"
114725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
11487c478bd9Sstevel@tonic-gate#
11497c478bd9Sstevel@tonic-gate# code: SUN4U-8002-72
11507c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo
11517c478bd9Sstevel@tonic-gate#
11527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.type"
11537c478bd9Sstevel@tonic-gatemsgstr "Fault"
11547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.severity"
11557c478bd9Sstevel@tonic-gatemsgstr "Critical"
11567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.description"
115725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
11587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.response"
115925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
11607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.impact"
116125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
11627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.action"
116325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
11647c478bd9Sstevel@tonic-gate#
11657c478bd9Sstevel@tonic-gate# code: SUN4U-8002-8A
11667c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.schizo
11677c478bd9Sstevel@tonic-gate#
11687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.type"
11697c478bd9Sstevel@tonic-gatemsgstr "Fault"
11707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.severity"
11717c478bd9Sstevel@tonic-gatemsgstr "Critical"
11727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.description"
117325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
11747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.response"
117525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
11767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.impact"
117725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
11787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.action"
117925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
11807c478bd9Sstevel@tonic-gate#
11817c478bd9Sstevel@tonic-gate# code: SUN4U-8002-9P
11827c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo
11837c478bd9Sstevel@tonic-gate#
11847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.type"
11857c478bd9Sstevel@tonic-gatemsgstr "Fault"
11867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.severity"
11877c478bd9Sstevel@tonic-gatemsgstr "Critical"
11887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.description"
118925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
11907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.response"
119125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
11927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.impact"
119325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
11947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.action"
119525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
11967c478bd9Sstevel@tonic-gate#
11977c478bd9Sstevel@tonic-gate# code: SUN4U-8002-A5
11987c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo
11997c478bd9Sstevel@tonic-gate#
12007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.type"
12017c478bd9Sstevel@tonic-gatemsgstr "Fault"
12027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.severity"
12037c478bd9Sstevel@tonic-gatemsgstr "Critical"
12047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.description"
120525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
12067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.response"
120725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
12087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.impact"
120925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
12107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.action"
121125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
12127c478bd9Sstevel@tonic-gate#
12137c478bd9Sstevel@tonic-gate# code: SUN4U-8002-CS
12147c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo
12157c478bd9Sstevel@tonic-gate#
12167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.type"
12177c478bd9Sstevel@tonic-gatemsgstr "Fault"
12187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.severity"
12197c478bd9Sstevel@tonic-gatemsgstr "Critical"
12207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.description"
122125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
12227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.response"
122325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
12247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.impact"
122525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
12267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.action"
122725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
12287c478bd9Sstevel@tonic-gate#
12297c478bd9Sstevel@tonic-gate# code: SUN4U-8002-D3
12307c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.schizo
12317c478bd9Sstevel@tonic-gate#
12327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.type"
12337c478bd9Sstevel@tonic-gatemsgstr "Fault"
12347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.severity"
12357c478bd9Sstevel@tonic-gatemsgstr "Critical"
12367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.description"
123725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
12387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.response"
123925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
12407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.impact"
124125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
12427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.action"
124325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
12447c478bd9Sstevel@tonic-gate#
12457c478bd9Sstevel@tonic-gate# code: SUN4U-8002-EY
12467c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo
12477c478bd9Sstevel@tonic-gate#
12487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.type"
12497c478bd9Sstevel@tonic-gatemsgstr "Fault"
12507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.severity"
12517c478bd9Sstevel@tonic-gatemsgstr "Critical"
12527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.description"
125325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
12547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.response"
125525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
12567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.impact"
125725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
12587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.action"
125925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
12607c478bd9Sstevel@tonic-gate#
12617c478bd9Sstevel@tonic-gate# code: SUN4U-8002-FD
12627c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo
12637c478bd9Sstevel@tonic-gate#
12647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.type"
12657c478bd9Sstevel@tonic-gatemsgstr "Fault"
12667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.severity"
12677c478bd9Sstevel@tonic-gatemsgstr "Critical"
12687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.description"
126925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
12707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.response"
127125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
12727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.impact"
127325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
12747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.action"
127525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
12767c478bd9Sstevel@tonic-gate#
12777c478bd9Sstevel@tonic-gate# code: SUN4U-8002-GH
12787c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo
12797c478bd9Sstevel@tonic-gate#
12807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.type"
12817c478bd9Sstevel@tonic-gatemsgstr "Fault"
12827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.severity"
12837c478bd9Sstevel@tonic-gatemsgstr "Critical"
12847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.description"
128525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
12867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.response"
128725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
12887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.impact"
128925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
12907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.action"
129125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
12927c478bd9Sstevel@tonic-gate#
12937c478bd9Sstevel@tonic-gate# code: SUN4U-8002-HC
12947c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.schizo
12957c478bd9Sstevel@tonic-gate#
12967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.type"
12977c478bd9Sstevel@tonic-gatemsgstr "Fault"
12987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.severity"
12997c478bd9Sstevel@tonic-gatemsgstr "Critical"
13007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.description"
130125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
13027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.response"
130325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
13047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.impact"
130525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
13067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.action"
130725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
13087c478bd9Sstevel@tonic-gate#
13097c478bd9Sstevel@tonic-gate# code: SUN4U-8002-JQ
13107c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo
13117c478bd9Sstevel@tonic-gate#
13127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.type"
13137c478bd9Sstevel@tonic-gatemsgstr "Fault"
13147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.severity"
13157c478bd9Sstevel@tonic-gatemsgstr "Critical"
13167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.description"
131725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
13187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.response"
131925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
13207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.impact"
132125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
13227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.action"
132325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
13247c478bd9Sstevel@tonic-gate#
13257c478bd9Sstevel@tonic-gate# code: SUN4U-8002-K4
13267c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
13277c478bd9Sstevel@tonic-gate#
13287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.type"
13297c478bd9Sstevel@tonic-gatemsgstr "Fault"
13307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.severity"
13317c478bd9Sstevel@tonic-gatemsgstr "Critical"
13327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.description"
133325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
13347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.response"
133525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
13367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.impact"
133725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
13387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.action"
133925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
13407c478bd9Sstevel@tonic-gate#
13417c478bd9Sstevel@tonic-gate# code: SUN4U-8002-LR
13427c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
13437c478bd9Sstevel@tonic-gate#
13447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.type"
13457c478bd9Sstevel@tonic-gatemsgstr "Fault"
13467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.severity"
13477c478bd9Sstevel@tonic-gatemsgstr "Critical"
13487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.description"
134925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
13507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.response"
135125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
13527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.impact"
135325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
13547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.action"
135525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
13567c478bd9Sstevel@tonic-gate#
13577c478bd9Sstevel@tonic-gate# code: SUN4U-8002-M2
13587c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.schizo
13597c478bd9Sstevel@tonic-gate#
13607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.type"
13617c478bd9Sstevel@tonic-gatemsgstr "Fault"
13627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.severity"
13637c478bd9Sstevel@tonic-gatemsgstr "Critical"
13647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.description"
136525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
13667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.response"
136725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
13687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.impact"
136925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
13707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.action"
137125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
13727c478bd9Sstevel@tonic-gate#
13737c478bd9Sstevel@tonic-gate# code: SUN4U-8002-NX
13747c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo
13757c478bd9Sstevel@tonic-gate#
13767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.type"
13777c478bd9Sstevel@tonic-gatemsgstr "Fault"
13787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.severity"
13797c478bd9Sstevel@tonic-gatemsgstr "Critical"
13807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.description"
138125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
13827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.response"
138325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
13847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.impact"
138525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
13867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.action"
138725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
13887c478bd9Sstevel@tonic-gate#
13897c478bd9Sstevel@tonic-gate# code: SUN4U-8002-PE
13907c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo
13917c478bd9Sstevel@tonic-gate#
13927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.type"
13937c478bd9Sstevel@tonic-gatemsgstr "Fault"
13947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.severity"
13957c478bd9Sstevel@tonic-gatemsgstr "Critical"
13967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.description"
139725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
13987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.response"
139925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
14007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.impact"
140125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
14027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.action"
140325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
14047c478bd9Sstevel@tonic-gate#
14057c478bd9Sstevel@tonic-gate# code: SUN4U-8002-QJ
14067c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo
14077c478bd9Sstevel@tonic-gate#
14087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.type"
14097c478bd9Sstevel@tonic-gatemsgstr "Fault"
14107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.severity"
14117c478bd9Sstevel@tonic-gatemsgstr "Critical"
14127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.description"
141325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
14147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.response"
141525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
14167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.impact"
141725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
14187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.action"
141925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
14207c478bd9Sstevel@tonic-gate#
14217c478bd9Sstevel@tonic-gate# code: SUN4U-8002-RS
14227c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo
14237c478bd9Sstevel@tonic-gate#
14247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.type"
14257c478bd9Sstevel@tonic-gatemsgstr "Fault"
14267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.severity"
14277c478bd9Sstevel@tonic-gatemsgstr "Critical"
14287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.description"
142925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
14307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.response"
143125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
14327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.impact"
143325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
14347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.action"
143525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
14367c478bd9Sstevel@tonic-gate#
14377c478bd9Sstevel@tonic-gate# code: SUN4U-8002-S5
14387c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo
14397c478bd9Sstevel@tonic-gate#
14407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.type"
14417c478bd9Sstevel@tonic-gatemsgstr "Fault"
14427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.severity"
14437c478bd9Sstevel@tonic-gatemsgstr "Critical"
14447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.description"
144525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
14467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.response"
144725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
14487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.impact"
144925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
14507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.action"
145125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
14527c478bd9Sstevel@tonic-gate#
14537c478bd9Sstevel@tonic-gate# code: SUN4U-8002-TP
14547c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
14557c478bd9Sstevel@tonic-gate#
14567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.type"
14577c478bd9Sstevel@tonic-gatemsgstr "Fault"
14587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.severity"
14597c478bd9Sstevel@tonic-gatemsgstr "Critical"
14607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.description"
146125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
14627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.response"
146325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
14647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.impact"
146525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
14667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.action"
146725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
14687c478bd9Sstevel@tonic-gate#
14697c478bd9Sstevel@tonic-gate# code: SUN4U-8002-UA
14707c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo
14717c478bd9Sstevel@tonic-gate#
14727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.type"
14737c478bd9Sstevel@tonic-gatemsgstr "Fault"
14747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.severity"
14757c478bd9Sstevel@tonic-gatemsgstr "Critical"
14767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.description"
147725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
14787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.response"
147925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
14807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.impact"
148125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
14827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.action"
148325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
14847c478bd9Sstevel@tonic-gate#
14857c478bd9Sstevel@tonic-gate# code: SUN4U-8002-VH
14867c478bd9Sstevel@tonic-gate# keys: fault.io.xmits
14877c478bd9Sstevel@tonic-gate#
14887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.type"
14897c478bd9Sstevel@tonic-gatemsgstr "Fault"
14907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.severity"
14917c478bd9Sstevel@tonic-gatemsgstr "Critical"
14927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.description"
149325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
14947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.response"
149525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
14967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.impact"
149725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
14987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.action"
149925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
15007c478bd9Sstevel@tonic-gate#
15017c478bd9Sstevel@tonic-gate# code: SUN4U-8002-WD
15027c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.xmits
15037c478bd9Sstevel@tonic-gate#
15047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.type"
15057c478bd9Sstevel@tonic-gatemsgstr "Fault"
15067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.severity"
15077c478bd9Sstevel@tonic-gatemsgstr "Critical"
15087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.description"
150925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
15107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.response"
151125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
15127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.impact"
151325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
15147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.action"
151525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
15167c478bd9Sstevel@tonic-gate#
15177c478bd9Sstevel@tonic-gate# code: SUN4U-8002-XY
15187c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.xmits
15197c478bd9Sstevel@tonic-gate#
15207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.type"
15217c478bd9Sstevel@tonic-gatemsgstr "Fault"
15227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.severity"
15237c478bd9Sstevel@tonic-gatemsgstr "Critical"
15247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.description"
152525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
15267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.response"
152725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
15287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.impact"
152925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
15307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.action"
153125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
15327c478bd9Sstevel@tonic-gate#
15337c478bd9Sstevel@tonic-gate# code: SUN4U-8002-Y3
15347c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits
15357c478bd9Sstevel@tonic-gate#
15367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.type"
15377c478bd9Sstevel@tonic-gatemsgstr "Fault"
15387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.severity"
15397c478bd9Sstevel@tonic-gatemsgstr "Critical"
15407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.description"
154125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
15427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.response"
154325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
15447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.impact"
154525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
15467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.action"
154725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
15487c478bd9Sstevel@tonic-gate#
15497c478bd9Sstevel@tonic-gate# code: SUN4U-8003-0Y
15507c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.xmits
15517c478bd9Sstevel@tonic-gate#
15527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.type"
15537c478bd9Sstevel@tonic-gatemsgstr "Fault"
15547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.severity"
15557c478bd9Sstevel@tonic-gatemsgstr "Critical"
15567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.description"
155725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
15587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.response"
155925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
15607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.impact"
156125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
15627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.action"
156325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
15647c478bd9Sstevel@tonic-gate#
15657c478bd9Sstevel@tonic-gate# code: SUN4U-8003-13
15667c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits
15677c478bd9Sstevel@tonic-gate#
15687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.type"
15697c478bd9Sstevel@tonic-gatemsgstr "Fault"
15707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.severity"
15717c478bd9Sstevel@tonic-gatemsgstr "Critical"
15727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.description"
157325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
15747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.response"
157525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
15767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.impact"
157725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
15787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.action"
157925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
15807c478bd9Sstevel@tonic-gate#
15817c478bd9Sstevel@tonic-gate# code: SUN4U-8003-2H
15827c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits
15837c478bd9Sstevel@tonic-gate#
15847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.type"
15857c478bd9Sstevel@tonic-gatemsgstr "Fault"
15867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.severity"
15877c478bd9Sstevel@tonic-gatemsgstr "Critical"
15887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.description"
158925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
15907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.response"
159125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
15927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.impact"
159325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
15947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.action"
159525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
15967c478bd9Sstevel@tonic-gate#
15977c478bd9Sstevel@tonic-gate# code: SUN4U-8003-3D
15987c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits
15997c478bd9Sstevel@tonic-gate#
16007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.type"
16017c478bd9Sstevel@tonic-gatemsgstr "Fault"
16027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.severity"
16037c478bd9Sstevel@tonic-gatemsgstr "Critical"
16047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.description"
160525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
16067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.response"
160725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
16087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.impact"
160925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
16107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.action"
161125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
16127c478bd9Sstevel@tonic-gate#
16137c478bd9Sstevel@tonic-gate# code: SUN4U-8003-4P
16147c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.xmits
16157c478bd9Sstevel@tonic-gate#
16167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.type"
16177c478bd9Sstevel@tonic-gatemsgstr "Fault"
16187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.severity"
16197c478bd9Sstevel@tonic-gatemsgstr "Critical"
16207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.description"
162125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
16227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.response"
162325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
16247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.impact"
162525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
16267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.action"
162725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
16287c478bd9Sstevel@tonic-gate#
16297c478bd9Sstevel@tonic-gate# code: SUN4U-8003-5A
16307c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.xmits
16317c478bd9Sstevel@tonic-gate#
16327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.type"
16337c478bd9Sstevel@tonic-gatemsgstr "Fault"
16347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.severity"
16357c478bd9Sstevel@tonic-gatemsgstr "Critical"
16367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.description"
163725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
16387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.response"
163925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
16407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.impact"
164125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
16427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.action"
164325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
16447c478bd9Sstevel@tonic-gate#
16457c478bd9Sstevel@tonic-gate# code: SUN4U-8003-6S
16467c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.xmits
16477c478bd9Sstevel@tonic-gate#
16487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.type"
16497c478bd9Sstevel@tonic-gatemsgstr "Fault"
16507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.severity"
16517c478bd9Sstevel@tonic-gatemsgstr "Critical"
16527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.description"
165325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
16547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.response"
165525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
16567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.impact"
165725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
16587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.action"
165925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
16607c478bd9Sstevel@tonic-gate#
16617c478bd9Sstevel@tonic-gate# code: SUN4U-8003-75
16627c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits
16637c478bd9Sstevel@tonic-gate#
16647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.type"
16657c478bd9Sstevel@tonic-gatemsgstr "Fault"
16667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.severity"
16677c478bd9Sstevel@tonic-gatemsgstr "Critical"
16687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.description"
166925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
16707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.response"
167125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
16727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.impact"
167325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
16747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.action"
167525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
16767c478bd9Sstevel@tonic-gate#
16777c478bd9Sstevel@tonic-gate# code: SUN4U-8003-8E
16787c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.xmits
16797c478bd9Sstevel@tonic-gate#
16807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.type"
16817c478bd9Sstevel@tonic-gatemsgstr "Fault"
16827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.severity"
16837c478bd9Sstevel@tonic-gatemsgstr "Critical"
16847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.description"
168525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
16867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.response"
168725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
16887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.impact"
168925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
16907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.action"
169125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
16927c478bd9Sstevel@tonic-gate#
16937c478bd9Sstevel@tonic-gate# code: SUN4U-8003-9J
16947c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits
16957c478bd9Sstevel@tonic-gate#
16967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.type"
16977c478bd9Sstevel@tonic-gatemsgstr "Fault"
16987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.severity"
16997c478bd9Sstevel@tonic-gatemsgstr "Critical"
17007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.description"
170125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
17027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.response"
170325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
17047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.impact"
170525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
17067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.action"
170725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
17087c478bd9Sstevel@tonic-gate#
17097c478bd9Sstevel@tonic-gate# code: SUN4U-8003-A2
17107c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits
17117c478bd9Sstevel@tonic-gate#
17127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.type"
17137c478bd9Sstevel@tonic-gatemsgstr "Fault"
17147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.severity"
17157c478bd9Sstevel@tonic-gatemsgstr "Critical"
17167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.description"
171725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
17187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.response"
171925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
17207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.impact"
172125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
17227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.action"
172325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
17247c478bd9Sstevel@tonic-gate#
17257c478bd9Sstevel@tonic-gate# code: SUN4U-8003-CX
17267c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits
17277c478bd9Sstevel@tonic-gate#
17287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.type"
17297c478bd9Sstevel@tonic-gatemsgstr "Fault"
17307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.severity"
17317c478bd9Sstevel@tonic-gatemsgstr "Critical"
17327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.description"
173325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
17347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.response"
173525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
17367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.impact"
173725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
17387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.action"
173925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
17407c478bd9Sstevel@tonic-gate#
17417c478bd9Sstevel@tonic-gate# code: SUN4U-8003-D4
17427c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.xmits
17437c478bd9Sstevel@tonic-gate#
17447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.type"
17457c478bd9Sstevel@tonic-gatemsgstr "Fault"
17467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.severity"
17477c478bd9Sstevel@tonic-gatemsgstr "Critical"
17487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.description"
174925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
17507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.response"
175125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
17527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.impact"
175325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
17547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.action"
175525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
17567c478bd9Sstevel@tonic-gate#
17577c478bd9Sstevel@tonic-gate# code: SUN4U-8003-ER
17587c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.xmits
17597c478bd9Sstevel@tonic-gate#
17607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.type"
17617c478bd9Sstevel@tonic-gatemsgstr "Fault"
17627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.severity"
17637c478bd9Sstevel@tonic-gatemsgstr "Critical"
17647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.description"
176525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
17667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.response"
176725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
17687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.impact"
176925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
17707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.action"
177125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
17727c478bd9Sstevel@tonic-gate#
17737c478bd9Sstevel@tonic-gate# code: SUN4U-8003-FC
17747c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.xmits
17757c478bd9Sstevel@tonic-gate#
17767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.type"
17777c478bd9Sstevel@tonic-gatemsgstr "Fault"
17787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.severity"
17797c478bd9Sstevel@tonic-gatemsgstr "Critical"
17807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.description"
178125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
17827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.response"
178325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
17847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.impact"
178525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
17867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.action"
178725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
17887c478bd9Sstevel@tonic-gate#
17897c478bd9Sstevel@tonic-gate# code: SUN4U-8003-GQ
17907c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits
17917c478bd9Sstevel@tonic-gate#
17927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.type"
17937c478bd9Sstevel@tonic-gatemsgstr "Fault"
17947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.severity"
17957c478bd9Sstevel@tonic-gatemsgstr "Critical"
17967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.description"
179725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
17987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.response"
179925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
18007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.impact"
180125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
18027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.action"
180325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
18047c478bd9Sstevel@tonic-gate#
18057c478bd9Sstevel@tonic-gate# code: SUN4U-8003-HD
18067c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.xmits
18077c478bd9Sstevel@tonic-gate#
18087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.type"
18097c478bd9Sstevel@tonic-gatemsgstr "Fault"
18107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.severity"
18117c478bd9Sstevel@tonic-gatemsgstr "Critical"
18127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.description"
181325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
18147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.response"
181525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
18167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.impact"
181725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
18187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.action"
181925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
18207c478bd9Sstevel@tonic-gate#
18217c478bd9Sstevel@tonic-gate# code: SUN4U-8003-JH
18227c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits
18237c478bd9Sstevel@tonic-gate#
18247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.type"
18257c478bd9Sstevel@tonic-gatemsgstr "Fault"
18267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.severity"
18277c478bd9Sstevel@tonic-gatemsgstr "Critical"
18287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.description"
182925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
18307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.response"
183125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
18327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.impact"
183325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
18347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.action"
183525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
18367c478bd9Sstevel@tonic-gate#
18377c478bd9Sstevel@tonic-gate# code: SUN4U-8003-K3
18387c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
18397c478bd9Sstevel@tonic-gate#
18407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.type"
18417c478bd9Sstevel@tonic-gatemsgstr "Fault"
18427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.severity"
18437c478bd9Sstevel@tonic-gatemsgstr "Critical"
18447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.description"
184525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
18467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.response"
184725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
18487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.impact"
184925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
18507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.action"
185125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
18527c478bd9Sstevel@tonic-gate#
18537c478bd9Sstevel@tonic-gate# code: SUN4U-8003-LY
18547c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
18557c478bd9Sstevel@tonic-gate#
18567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.type"
18577c478bd9Sstevel@tonic-gatemsgstr "Fault"
18587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.severity"
18597c478bd9Sstevel@tonic-gatemsgstr "Critical"
18607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.description"
186125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
18627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.response"
186325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
18647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.impact"
186525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
18667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.action"
186725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
18687c478bd9Sstevel@tonic-gate#
18697c478bd9Sstevel@tonic-gate# code: SUN4U-8003-M5
18707c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.xmits
18717c478bd9Sstevel@tonic-gate#
18727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.type"
18737c478bd9Sstevel@tonic-gatemsgstr "Fault"
18747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.severity"
18757c478bd9Sstevel@tonic-gatemsgstr "Critical"
18767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.description"
187725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
18787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.response"
187925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
18807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.impact"
188125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
18827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.action"
188325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
18847c478bd9Sstevel@tonic-gate#
18857c478bd9Sstevel@tonic-gate# code: SUN4U-8003-NS
18867c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits
18877c478bd9Sstevel@tonic-gate#
18887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.type"
18897c478bd9Sstevel@tonic-gatemsgstr "Fault"
18907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.severity"
18917c478bd9Sstevel@tonic-gatemsgstr "Critical"
18927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.description"
189325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
18947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.response"
189525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
18967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.impact"
189725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
18987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.action"
189925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
19007c478bd9Sstevel@tonic-gate#
19017c478bd9Sstevel@tonic-gate# code: SUN4U-8003-PA
19027c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits
19037c478bd9Sstevel@tonic-gate#
19047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.type"
19057c478bd9Sstevel@tonic-gatemsgstr "Fault"
19067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.severity"
19077c478bd9Sstevel@tonic-gatemsgstr "Critical"
19087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.description"
190925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
19107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.response"
191125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
19127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.impact"
191325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
19147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.action"
191525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
19167c478bd9Sstevel@tonic-gate#
19177c478bd9Sstevel@tonic-gate# code: SUN4U-8003-QP
19187c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits
19197c478bd9Sstevel@tonic-gate#
19207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.type"
19217c478bd9Sstevel@tonic-gatemsgstr "Fault"
19227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.severity"
19237c478bd9Sstevel@tonic-gatemsgstr "Critical"
19247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.description"
192525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
19267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.response"
192725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
19287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.impact"
192925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
19307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.action"
193125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
19327c478bd9Sstevel@tonic-gate#
19337c478bd9Sstevel@tonic-gate# code: SUN4U-8003-RX
19347c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits
19357c478bd9Sstevel@tonic-gate#
19367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.type"
19377c478bd9Sstevel@tonic-gatemsgstr "Fault"
19387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.severity"
19397c478bd9Sstevel@tonic-gatemsgstr "Critical"
19407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.description"
194125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
19427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.response"
194325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
19447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.impact"
194525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
19467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.action"
194725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
19487c478bd9Sstevel@tonic-gate#
19497c478bd9Sstevel@tonic-gate# code: SUN4U-8003-S2
19507c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits
19517c478bd9Sstevel@tonic-gate#
19527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.type"
19537c478bd9Sstevel@tonic-gatemsgstr "Fault"
19547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.severity"
19557c478bd9Sstevel@tonic-gatemsgstr "Critical"
19567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.description"
195725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
19587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.response"
195925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
19607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.impact"
196125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
19627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.action"
196325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
19647c478bd9Sstevel@tonic-gate#
19657c478bd9Sstevel@tonic-gate# code: SUN4U-8003-TJ
19667c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
19677c478bd9Sstevel@tonic-gate#
19687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.type"
19697c478bd9Sstevel@tonic-gatemsgstr "Fault"
19707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.severity"
19717c478bd9Sstevel@tonic-gatemsgstr "Critical"
19727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.description"
197325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
19747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.response"
197525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
19767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.impact"
197725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
19787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.action"
197925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
19807c478bd9Sstevel@tonic-gate#
19817c478bd9Sstevel@tonic-gate# code: SUN4U-8003-UE
19827c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits
19837c478bd9Sstevel@tonic-gate#
19847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.type"
19857c478bd9Sstevel@tonic-gatemsgstr "Fault"
19867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.severity"
19877c478bd9Sstevel@tonic-gatemsgstr "Critical"
19887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.description"
198925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
19907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.response"
199125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
19927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.impact"
199325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
19947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.action"
199525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
19967c478bd9Sstevel@tonic-gate#
19977c478bd9Sstevel@tonic-gate# code: SUN4U-8003-VQ
19987c478bd9Sstevel@tonic-gate# keys: fault.io.schizo fault.io.xmits
19997c478bd9Sstevel@tonic-gate#
20007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.type"
20017c478bd9Sstevel@tonic-gatemsgstr "Fault"
20027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.severity"
20037c478bd9Sstevel@tonic-gatemsgstr "Critical"
20047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.description"
200525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
20067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.response"
200725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
20087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.impact"
200925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
20107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.action"
201125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
20127c478bd9Sstevel@tonic-gate#
20137c478bd9Sstevel@tonic-gate# code: SUN4U-8003-WC
20147c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.schizo fault.io.xmits
20157c478bd9Sstevel@tonic-gate#
20167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.type"
20177c478bd9Sstevel@tonic-gatemsgstr "Fault"
20187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.severity"
20197c478bd9Sstevel@tonic-gatemsgstr "Critical"
20207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.description"
202125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
20227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.response"
202325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
20247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.impact"
202525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
20267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.action"
202725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
20287c478bd9Sstevel@tonic-gate#
20297c478bd9Sstevel@tonic-gate# code: SUN4U-8003-XR
20307c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.schizo fault.io.xmits
20317c478bd9Sstevel@tonic-gate#
20327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.type"
20337c478bd9Sstevel@tonic-gatemsgstr "Fault"
20347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.severity"
20357c478bd9Sstevel@tonic-gatemsgstr "Critical"
20367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.description"
203725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
20387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.response"
203925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
20407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.impact"
204125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
20427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.action"
204325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
20447c478bd9Sstevel@tonic-gate#
20457c478bd9Sstevel@tonic-gate# code: SUN4U-8003-Y4
20467c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits
20477c478bd9Sstevel@tonic-gate#
20487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.type"
20497c478bd9Sstevel@tonic-gatemsgstr "Fault"
20507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.severity"
20517c478bd9Sstevel@tonic-gatemsgstr "Critical"
20527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.description"
205325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
20547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.response"
205525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
20567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.impact"
205725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
20587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.action"
205925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
20607c478bd9Sstevel@tonic-gate#
20617c478bd9Sstevel@tonic-gate# code: SUN4U-8004-0A
20627c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.schizo fault.io.xmits
20637c478bd9Sstevel@tonic-gate#
20647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.type"
20657c478bd9Sstevel@tonic-gatemsgstr "Fault"
20667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.severity"
20677c478bd9Sstevel@tonic-gatemsgstr "Critical"
20687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.description"
206925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
20707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.response"
207125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
20727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.impact"
207325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
20747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.action"
207525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
20767c478bd9Sstevel@tonic-gate#
20777c478bd9Sstevel@tonic-gate# code: SUN4U-8004-1P
20787c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits
20797c478bd9Sstevel@tonic-gate#
20807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.type"
20817c478bd9Sstevel@tonic-gatemsgstr "Fault"
20827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.severity"
20837c478bd9Sstevel@tonic-gatemsgstr "Critical"
20847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.description"
208525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
20867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.response"
208725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
20887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.impact"
208925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
20907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.action"
209125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
20927c478bd9Sstevel@tonic-gate#
20937c478bd9Sstevel@tonic-gate# code: SUN4U-8004-25
20947c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
20957c478bd9Sstevel@tonic-gate#
20967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.type"
20977c478bd9Sstevel@tonic-gatemsgstr "Fault"
20987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.severity"
20997c478bd9Sstevel@tonic-gatemsgstr "Critical"
21007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.description"
210125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
21027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.response"
210325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
21047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.impact"
210525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
21067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.action"
210725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
21087c478bd9Sstevel@tonic-gate#
21097c478bd9Sstevel@tonic-gate# code: SUN4U-8004-3S
21107c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
21117c478bd9Sstevel@tonic-gate#
21127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.type"
21137c478bd9Sstevel@tonic-gatemsgstr "Fault"
21147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.severity"
21157c478bd9Sstevel@tonic-gatemsgstr "Critical"
21167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.description"
211725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
21187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.response"
211925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
21207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.impact"
212125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
21227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.action"
212325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
21247c478bd9Sstevel@tonic-gate#
21257c478bd9Sstevel@tonic-gate# code: SUN4U-8004-43
21267c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.schizo fault.io.xmits
21277c478bd9Sstevel@tonic-gate#
21287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.type"
21297c478bd9Sstevel@tonic-gatemsgstr "Fault"
21307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.severity"
21317c478bd9Sstevel@tonic-gatemsgstr "Critical"
21327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.description"
213325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
21347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.response"
213525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
21367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.impact"
213725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
21387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.action"
213925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
21407c478bd9Sstevel@tonic-gate#
21417c478bd9Sstevel@tonic-gate# code: SUN4U-8004-5Y
21427c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits
21437c478bd9Sstevel@tonic-gate#
21447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.type"
21457c478bd9Sstevel@tonic-gatemsgstr "Fault"
21467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.severity"
21477c478bd9Sstevel@tonic-gatemsgstr "Critical"
21487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.description"
214925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
21507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.response"
215125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
21527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.impact"
215325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
21547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.action"
215525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
21567c478bd9Sstevel@tonic-gate#
21577c478bd9Sstevel@tonic-gate# code: SUN4U-8004-6D
21587c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits
21597c478bd9Sstevel@tonic-gate#
21607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.type"
21617c478bd9Sstevel@tonic-gatemsgstr "Fault"
21627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.severity"
21637c478bd9Sstevel@tonic-gatemsgstr "Critical"
21647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.description"
216525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
21667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.response"
216725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
21687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.impact"
216925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
21707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.action"
217125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
21727c478bd9Sstevel@tonic-gate#
21737c478bd9Sstevel@tonic-gate# code: SUN4U-8004-7H
21747c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits
21757c478bd9Sstevel@tonic-gate#
21767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.type"
21777c478bd9Sstevel@tonic-gatemsgstr "Fault"
21787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.severity"
21797c478bd9Sstevel@tonic-gatemsgstr "Critical"
21807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.description"
218125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
21827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.response"
218325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
21847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.impact"
218525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
21867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.action"
218725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
21887c478bd9Sstevel@tonic-gate#
21897c478bd9Sstevel@tonic-gate# code: SUN4U-8004-8R
21907c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits
21917c478bd9Sstevel@tonic-gate#
21927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.type"
21937c478bd9Sstevel@tonic-gatemsgstr "Fault"
21947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.severity"
21957c478bd9Sstevel@tonic-gatemsgstr "Critical"
21967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.description"
219725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
21987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.response"
219925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
22007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.impact"
220125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
22027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.action"
220325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
22047c478bd9Sstevel@tonic-gate#
22057c478bd9Sstevel@tonic-gate# code: SUN4U-8004-94
22067c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits
22077c478bd9Sstevel@tonic-gate#
22087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.type"
22097c478bd9Sstevel@tonic-gatemsgstr "Fault"
22107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.severity"
22117c478bd9Sstevel@tonic-gatemsgstr "Critical"
22127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.description"
221325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
22147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.response"
221525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
22167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.impact"
221725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
22187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.action"
221925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
22207c478bd9Sstevel@tonic-gate#
22217c478bd9Sstevel@tonic-gate# code: SUN4U-8004-AQ
22227c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
22237c478bd9Sstevel@tonic-gate#
22247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.type"
22257c478bd9Sstevel@tonic-gatemsgstr "Fault"
22267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.severity"
22277c478bd9Sstevel@tonic-gatemsgstr "Critical"
22287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.description"
222925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
22307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.response"
223125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
22327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.impact"
223325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
22347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.action"
223525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
22367c478bd9Sstevel@tonic-gate#
22377c478bd9Sstevel@tonic-gate# code: SUN4U-8004-CC
22387c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
22397c478bd9Sstevel@tonic-gate#
22407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.type"
22417c478bd9Sstevel@tonic-gatemsgstr "Fault"
22427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.severity"
22437c478bd9Sstevel@tonic-gatemsgstr "Critical"
22447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.description"
224525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
22467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.response"
224725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
22487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.impact"
224925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
22507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.action"
225125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
22527c478bd9Sstevel@tonic-gate#
22537c478bd9Sstevel@tonic-gate# code: SUN4U-8004-DJ
22547c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.schizo fault.io.xmits
22557c478bd9Sstevel@tonic-gate#
22567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.type"
22577c478bd9Sstevel@tonic-gatemsgstr "Fault"
22587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.severity"
22597c478bd9Sstevel@tonic-gatemsgstr "Critical"
22607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.description"
226125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
22627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.response"
226325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
22647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.impact"
226525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
22667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.action"
226725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
22687c478bd9Sstevel@tonic-gate#
22697c478bd9Sstevel@tonic-gate# code: SUN4U-8004-EE
22707c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits
22717c478bd9Sstevel@tonic-gate#
22727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.type"
22737c478bd9Sstevel@tonic-gatemsgstr "Fault"
22747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.severity"
22757c478bd9Sstevel@tonic-gatemsgstr "Critical"
22767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.description"
227725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
22787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.response"
227925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
22807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.impact"
228125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
22827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.action"
228325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
22847c478bd9Sstevel@tonic-gate#
22857c478bd9Sstevel@tonic-gate# code: SUN4U-8004-FX
22867c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
22877c478bd9Sstevel@tonic-gate#
22887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.type"
22897c478bd9Sstevel@tonic-gatemsgstr "Fault"
22907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.severity"
22917c478bd9Sstevel@tonic-gatemsgstr "Critical"
22927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.description"
229325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
22947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.response"
229525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
22967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.impact"
229725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
22987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.action"
229925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
23007c478bd9Sstevel@tonic-gate#
23017c478bd9Sstevel@tonic-gate# code: SUN4U-8004-G2
23027c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
23037c478bd9Sstevel@tonic-gate#
23047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.type"
23057c478bd9Sstevel@tonic-gatemsgstr "Fault"
23067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.severity"
23077c478bd9Sstevel@tonic-gatemsgstr "Critical"
23087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.description"
230925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
23107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.response"
231125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
23127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.impact"
231325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
23147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.action"
231525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
23167c478bd9Sstevel@tonic-gate#
23177c478bd9Sstevel@tonic-gate# code: SUN4U-8004-HS
23187c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
23197c478bd9Sstevel@tonic-gate#
23207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.type"
23217c478bd9Sstevel@tonic-gatemsgstr "Fault"
23227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.severity"
23237c478bd9Sstevel@tonic-gatemsgstr "Critical"
23247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.description"
232525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
23267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.response"
232725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
23287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.impact"
232925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
23307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.action"
233125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
23327c478bd9Sstevel@tonic-gate#
23337c478bd9Sstevel@tonic-gate# code: SUN4U-8004-J5
23347c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
23357c478bd9Sstevel@tonic-gate#
23367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.type"
23377c478bd9Sstevel@tonic-gatemsgstr "Fault"
23387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.severity"
23397c478bd9Sstevel@tonic-gatemsgstr "Critical"
23407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.description"
234125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
23427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.response"
234325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
23447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.impact"
234525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
23467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.action"
234725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
23487c478bd9Sstevel@tonic-gate#
23497c478bd9Sstevel@tonic-gate# code: SUN4U-8004-KP
23507c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
23517c478bd9Sstevel@tonic-gate#
23527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.type"
23537c478bd9Sstevel@tonic-gatemsgstr "Fault"
23547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.severity"
23557c478bd9Sstevel@tonic-gatemsgstr "Critical"
23567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.description"
235725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
23587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.response"
235925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
23607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.impact"
236125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
23627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.action"
236325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
23647c478bd9Sstevel@tonic-gate#
23657c478bd9Sstevel@tonic-gate# code: SUN4U-8004-LA
23667c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
23677c478bd9Sstevel@tonic-gate#
23687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.type"
23697c478bd9Sstevel@tonic-gatemsgstr "Fault"
23707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.severity"
23717c478bd9Sstevel@tonic-gatemsgstr "Critical"
23727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.description"
237325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
23747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.response"
237525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
23767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.impact"
237725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
23787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.action"
237925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
23807c478bd9Sstevel@tonic-gate#
23817c478bd9Sstevel@tonic-gate# code: SUN4U-8004-MH
23827c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits
23837c478bd9Sstevel@tonic-gate#
23847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.type"
23857c478bd9Sstevel@tonic-gatemsgstr "Fault"
23867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.severity"
23877c478bd9Sstevel@tonic-gatemsgstr "Critical"
23887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.description"
238925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
23907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.response"
239125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
23927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.impact"
239325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
23947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.action"
239525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
23967c478bd9Sstevel@tonic-gate#
23977c478bd9Sstevel@tonic-gate# code: SUN4U-8004-ND
23987c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits
23997c478bd9Sstevel@tonic-gate#
24007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.type"
24017c478bd9Sstevel@tonic-gatemsgstr "Fault"
24027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.severity"
24037c478bd9Sstevel@tonic-gatemsgstr "Critical"
24047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.description"
240525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
24067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.response"
240725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
24087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.impact"
240925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
24107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.action"
241125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
24127c478bd9Sstevel@tonic-gate#
24137c478bd9Sstevel@tonic-gate# code: SUN4U-8004-PY
24147c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
24157c478bd9Sstevel@tonic-gate#
24167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.type"
24177c478bd9Sstevel@tonic-gatemsgstr "Fault"
24187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.severity"
24197c478bd9Sstevel@tonic-gatemsgstr "Critical"
24207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.description"
242125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
24227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.response"
242325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
24247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.impact"
242525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
24267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.action"
242725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
24287c478bd9Sstevel@tonic-gate#
24297c478bd9Sstevel@tonic-gate# code: SUN4U-8004-Q3
24307c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits
24317c478bd9Sstevel@tonic-gate#
24327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.type"
24337c478bd9Sstevel@tonic-gatemsgstr "Fault"
24347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.severity"
24357c478bd9Sstevel@tonic-gatemsgstr "Critical"
24367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.description"
243725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
24387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.response"
243925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
24407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.impact"
244125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
24427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.action"
244325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
24447c478bd9Sstevel@tonic-gate#
24457c478bd9Sstevel@tonic-gate# code: SUN4U-8004-RC
24467c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
24477c478bd9Sstevel@tonic-gate#
24487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.type"
24497c478bd9Sstevel@tonic-gatemsgstr "Fault"
24507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.severity"
24517c478bd9Sstevel@tonic-gatemsgstr "Critical"
24527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.description"
245325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
24547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.response"
245525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
24567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.impact"
245725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
24587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.action"
245925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
24607c478bd9Sstevel@tonic-gate#
24617c478bd9Sstevel@tonic-gate# code: SUN4U-8004-SQ
24627c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits
24637c478bd9Sstevel@tonic-gate#
24647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.type"
24657c478bd9Sstevel@tonic-gatemsgstr "Fault"
24667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.severity"
24677c478bd9Sstevel@tonic-gatemsgstr "Critical"
24687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.description"
246925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
24707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.response"
247125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
24727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.impact"
247325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
24747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.action"
247525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
24767c478bd9Sstevel@tonic-gate#
24777c478bd9Sstevel@tonic-gate# code: SUN4U-8004-T4
24787c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
24797c478bd9Sstevel@tonic-gate#
24807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.type"
24817c478bd9Sstevel@tonic-gatemsgstr "Fault"
24827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.severity"
24837c478bd9Sstevel@tonic-gatemsgstr "Critical"
24847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.description"
248525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
24867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.response"
248725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
24887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.impact"
248925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
24907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.action"
249125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
24927c478bd9Sstevel@tonic-gate#
24937c478bd9Sstevel@tonic-gate# code: SUN4U-8004-UR
24947c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits
24957c478bd9Sstevel@tonic-gate#
24967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.type"
24977c478bd9Sstevel@tonic-gatemsgstr "Fault"
24987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.severity"
24997c478bd9Sstevel@tonic-gatemsgstr "Critical"
25007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.description"
250125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
25027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.response"
250325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
25047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.impact"
250525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
25067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.action"
250725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
25087c478bd9Sstevel@tonic-gate#
25097c478bd9Sstevel@tonic-gate# code: SUN4U-8004-V2
25107c478bd9Sstevel@tonic-gate# keys: fault.io.psycho
25117c478bd9Sstevel@tonic-gate#
25127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.type"
25137c478bd9Sstevel@tonic-gatemsgstr "Fault"
25147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.severity"
25157c478bd9Sstevel@tonic-gatemsgstr "Critical"
25167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.description"
251725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
25187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.response"
251925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
25207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.impact"
252125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
25227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.action"
252325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
25247c478bd9Sstevel@tonic-gate#
25257c478bd9Sstevel@tonic-gate# code: SUN4U-8004-WX
25267c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.psycho
25277c478bd9Sstevel@tonic-gate#
25287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.type"
25297c478bd9Sstevel@tonic-gatemsgstr "Fault"
25307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.severity"
25317c478bd9Sstevel@tonic-gatemsgstr "Critical"
25327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.description"
253325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
25347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.response"
253525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
25367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.impact"
253725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
25387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.action"
253925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
25407c478bd9Sstevel@tonic-gate#
25417c478bd9Sstevel@tonic-gate# code: SUN4U-8004-XE
25427c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.psycho
25437c478bd9Sstevel@tonic-gate#
25447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.type"
25457c478bd9Sstevel@tonic-gatemsgstr "Fault"
25467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.severity"
25477c478bd9Sstevel@tonic-gatemsgstr "Critical"
25487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.description"
254925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
25507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.response"
255125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
25527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.impact"
255325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
25547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.action"
255525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
25567c478bd9Sstevel@tonic-gate#
25577c478bd9Sstevel@tonic-gate# code: SUN4U-8004-YJ
25587c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.psycho
25597c478bd9Sstevel@tonic-gate#
25607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.type"
25617c478bd9Sstevel@tonic-gatemsgstr "Fault"
25627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.severity"
25637c478bd9Sstevel@tonic-gatemsgstr "Critical"
25647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.description"
256525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
25667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.response"
256725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
25687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.impact"
256925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
25707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.action"
257125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
25727c478bd9Sstevel@tonic-gate#
25737c478bd9Sstevel@tonic-gate# code: SUN4U-8005-0E
25747c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.psycho
25757c478bd9Sstevel@tonic-gate#
25767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.type"
25777c478bd9Sstevel@tonic-gatemsgstr "Fault"
25787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.severity"
25797c478bd9Sstevel@tonic-gatemsgstr "Critical"
25807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.description"
258125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
25827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.response"
258325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
25847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.impact"
258525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
25867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.action"
258725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
25887c478bd9Sstevel@tonic-gate#
25897c478bd9Sstevel@tonic-gate# code: SUN4U-8005-1J
25907c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.psycho
25917c478bd9Sstevel@tonic-gate#
25927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.type"
25937c478bd9Sstevel@tonic-gatemsgstr "Fault"
25947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.severity"
25957c478bd9Sstevel@tonic-gatemsgstr "Critical"
25967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.description"
259725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
25987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.response"
259925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
26007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.impact"
260125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
26027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.action"
260325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
26047c478bd9Sstevel@tonic-gate#
26057c478bd9Sstevel@tonic-gate# code: SUN4U-8005-22
26067c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.psycho
26077c478bd9Sstevel@tonic-gate#
26087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.type"
26097c478bd9Sstevel@tonic-gatemsgstr "Fault"
26107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.severity"
26117c478bd9Sstevel@tonic-gatemsgstr "Critical"
26127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.description"
261325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
26147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.response"
261525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
26167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.impact"
261725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
26187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.action"
261925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
26207c478bd9Sstevel@tonic-gate#
26217c478bd9Sstevel@tonic-gate# code: SUN4U-8005-3X
26227c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho
26237c478bd9Sstevel@tonic-gate#
26247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.type"
26257c478bd9Sstevel@tonic-gatemsgstr "Fault"
26267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.severity"
26277c478bd9Sstevel@tonic-gatemsgstr "Critical"
26287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.description"
262925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
26307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.response"
263125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
26327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.impact"
263325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
26347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.action"
263525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
26367c478bd9Sstevel@tonic-gate#
26377c478bd9Sstevel@tonic-gate# code: SUN4U-8005-44
26387c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.psycho
26397c478bd9Sstevel@tonic-gate#
26407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.type"
26417c478bd9Sstevel@tonic-gatemsgstr "Fault"
26427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.severity"
26437c478bd9Sstevel@tonic-gatemsgstr "Critical"
26447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.description"
264525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
26467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.response"
264725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
26487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.impact"
264925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
26507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.action"
265125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
26527c478bd9Sstevel@tonic-gate#
26537c478bd9Sstevel@tonic-gate# code: SUN4U-8005-5R
26547c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho
26557c478bd9Sstevel@tonic-gate#
26567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.type"
26577c478bd9Sstevel@tonic-gatemsgstr "Fault"
26587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.severity"
26597c478bd9Sstevel@tonic-gatemsgstr "Critical"
26607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.description"
266125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
26627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.response"
266325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
26647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.impact"
266525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
26667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.action"
266725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
26687c478bd9Sstevel@tonic-gate#
26697c478bd9Sstevel@tonic-gate# code: SUN4U-8005-6C
26707c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.psycho
26717c478bd9Sstevel@tonic-gate#
26727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.type"
26737c478bd9Sstevel@tonic-gatemsgstr "Fault"
26747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.severity"
26757c478bd9Sstevel@tonic-gatemsgstr "Critical"
26767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.description"
267725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
26787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.response"
267925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
26807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.impact"
268125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
26827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.action"
268325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
26847c478bd9Sstevel@tonic-gate#
26857c478bd9Sstevel@tonic-gate# code: SUN4U-8005-7Q
26867c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho
26877c478bd9Sstevel@tonic-gate#
26887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.type"
26897c478bd9Sstevel@tonic-gatemsgstr "Fault"
26907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.severity"
26917c478bd9Sstevel@tonic-gatemsgstr "Critical"
26927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.description"
269325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
26947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.response"
269525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
26967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.impact"
269725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
26987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.action"
269925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
27007c478bd9Sstevel@tonic-gate#
27017c478bd9Sstevel@tonic-gate# code: SUN4U-8005-8Y
27027c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.psycho
27037c478bd9Sstevel@tonic-gate#
27047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.type"
27057c478bd9Sstevel@tonic-gatemsgstr "Fault"
27067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.severity"
27077c478bd9Sstevel@tonic-gatemsgstr "Critical"
27087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.description"
270925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
27107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.response"
271125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
27127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.impact"
271325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
27147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.action"
271525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
27167c478bd9Sstevel@tonic-gate#
27177c478bd9Sstevel@tonic-gate# code: SUN4U-8005-93
27187c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho
27197c478bd9Sstevel@tonic-gate#
27207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.type"
27217c478bd9Sstevel@tonic-gatemsgstr "Fault"
27227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.severity"
27237c478bd9Sstevel@tonic-gatemsgstr "Critical"
27247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.description"
272525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
27267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.response"
272725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
27287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.impact"
272925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
27307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.action"
273125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
27327c478bd9Sstevel@tonic-gate#
27337c478bd9Sstevel@tonic-gate# code: SUN4U-8005-AH
27347c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho
27357c478bd9Sstevel@tonic-gate#
27367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.type"
27377c478bd9Sstevel@tonic-gatemsgstr "Fault"
27387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.severity"
27397c478bd9Sstevel@tonic-gatemsgstr "Critical"
27407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.description"
274125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
27427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.response"
274325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
27447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.impact"
274525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
27467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.action"
274725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
27487c478bd9Sstevel@tonic-gate#
27497c478bd9Sstevel@tonic-gate# code: SUN4U-8005-CD
27507c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho
27517c478bd9Sstevel@tonic-gate#
27527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.type"
27537c478bd9Sstevel@tonic-gatemsgstr "Fault"
27547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.severity"
27557c478bd9Sstevel@tonic-gatemsgstr "Critical"
27567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.description"
275725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
27587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.response"
275925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
27607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.impact"
276125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
27627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.action"
276325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
27647c478bd9Sstevel@tonic-gate#
27657c478bd9Sstevel@tonic-gate# code: SUN4U-8005-DP
27667c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.psycho
27677c478bd9Sstevel@tonic-gate#
27687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.type"
27697c478bd9Sstevel@tonic-gatemsgstr "Fault"
27707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.severity"
27717c478bd9Sstevel@tonic-gatemsgstr "Critical"
27727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.description"
277325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
27747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.response"
277525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
27767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.impact"
277725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
27787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.action"
277925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
27807c478bd9Sstevel@tonic-gate#
27817c478bd9Sstevel@tonic-gate# code: SUN4U-8005-EA
27827c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho
27837c478bd9Sstevel@tonic-gate#
27847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.type"
27857c478bd9Sstevel@tonic-gatemsgstr "Fault"
27867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.severity"
27877c478bd9Sstevel@tonic-gatemsgstr "Critical"
27887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.description"
278925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
27907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.response"
279125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
27927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.impact"
279325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
27947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.action"
279525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
27967c478bd9Sstevel@tonic-gate#
27977c478bd9Sstevel@tonic-gate# code: SUN4U-8005-FS
27987c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.psycho
27997c478bd9Sstevel@tonic-gate#
28007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.type"
28017c478bd9Sstevel@tonic-gatemsgstr "Fault"
28027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.severity"
28037c478bd9Sstevel@tonic-gatemsgstr "Critical"
28047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.description"
280525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
28067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.response"
280725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
28087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.impact"
280925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
28107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.action"
281125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
28127c478bd9Sstevel@tonic-gate#
28137c478bd9Sstevel@tonic-gate# code: SUN4U-8005-G5
28147c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho
28157c478bd9Sstevel@tonic-gate#
28167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.type"
28177c478bd9Sstevel@tonic-gatemsgstr "Fault"
28187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.severity"
28197c478bd9Sstevel@tonic-gatemsgstr "Critical"
28207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.description"
282125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
28227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.response"
282325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
28247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.impact"
282525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
28267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.action"
282725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
28287c478bd9Sstevel@tonic-gate#
28297c478bd9Sstevel@tonic-gate# code: SUN4U-8005-HX
28307c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.psycho
28317c478bd9Sstevel@tonic-gate#
28327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.type"
28337c478bd9Sstevel@tonic-gatemsgstr "Fault"
28347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.severity"
28357c478bd9Sstevel@tonic-gatemsgstr "Critical"
28367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.description"
283725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
28387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.response"
283925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
28407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.impact"
284125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
28427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.action"
284325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
28447c478bd9Sstevel@tonic-gate#
28457c478bd9Sstevel@tonic-gate# code: SUN4U-8005-J2
28467c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho
28477c478bd9Sstevel@tonic-gate#
28487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.type"
28497c478bd9Sstevel@tonic-gatemsgstr "Fault"
28507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.severity"
28517c478bd9Sstevel@tonic-gatemsgstr "Critical"
28527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.description"
285325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
28547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.response"
285525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
28567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.impact"
285725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
28587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.action"
285925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
28607c478bd9Sstevel@tonic-gate#
28617c478bd9Sstevel@tonic-gate# code: SUN4U-8005-KJ
28627c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho
28637c478bd9Sstevel@tonic-gate#
28647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.type"
28657c478bd9Sstevel@tonic-gatemsgstr "Fault"
28667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.severity"
28677c478bd9Sstevel@tonic-gatemsgstr "Critical"
28687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.description"
286925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
28707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.response"
287125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
28727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.impact"
287325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
28747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.action"
287525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
28767c478bd9Sstevel@tonic-gate#
28777c478bd9Sstevel@tonic-gate# code: SUN4U-8005-LE
28787c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho
28797c478bd9Sstevel@tonic-gate#
28807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.type"
28817c478bd9Sstevel@tonic-gatemsgstr "Fault"
28827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.severity"
28837c478bd9Sstevel@tonic-gatemsgstr "Critical"
28847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.description"
288525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
28867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.response"
288725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
28887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.impact"
288925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
28907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.action"
289125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
28927c478bd9Sstevel@tonic-gate#
28937c478bd9Sstevel@tonic-gate# code: SUN4U-8005-MQ
28947c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho
28957c478bd9Sstevel@tonic-gate#
28967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.type"
28977c478bd9Sstevel@tonic-gatemsgstr "Fault"
28987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.severity"
28997c478bd9Sstevel@tonic-gatemsgstr "Critical"
29007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.description"
290125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
29027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.response"
290325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
29047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.impact"
290525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
29067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.action"
290725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
29087c478bd9Sstevel@tonic-gate#
29097c478bd9Sstevel@tonic-gate# code: SUN4U-8005-NC
29107c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho
29117c478bd9Sstevel@tonic-gate#
29127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.type"
29137c478bd9Sstevel@tonic-gatemsgstr "Fault"
29147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.severity"
29157c478bd9Sstevel@tonic-gatemsgstr "Critical"
29167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.description"
291725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
29187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.response"
291925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
29207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.impact"
292125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
29227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.action"
292325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
29247c478bd9Sstevel@tonic-gate#
29257c478bd9Sstevel@tonic-gate# code: SUN4U-8005-PR
29267c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho
29277c478bd9Sstevel@tonic-gate#
29287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.type"
29297c478bd9Sstevel@tonic-gatemsgstr "Fault"
29307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.severity"
29317c478bd9Sstevel@tonic-gatemsgstr "Critical"
29327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.description"
293325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
29347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.response"
293525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
29367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.impact"
293725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
29387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.action"
293925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
29407c478bd9Sstevel@tonic-gate#
29417c478bd9Sstevel@tonic-gate# code: SUN4U-8005-Q4
29427c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho
29437c478bd9Sstevel@tonic-gate#
29447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.type"
29457c478bd9Sstevel@tonic-gatemsgstr "Fault"
29467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.severity"
29477c478bd9Sstevel@tonic-gatemsgstr "Critical"
29487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.description"
294925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
29507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.response"
295125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
29527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.impact"
295325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
29547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.action"
295525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
29567c478bd9Sstevel@tonic-gate#
29577c478bd9Sstevel@tonic-gate# code: SUN4U-8005-RD
29587c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
29597c478bd9Sstevel@tonic-gate#
29607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.type"
29617c478bd9Sstevel@tonic-gatemsgstr "Fault"
29627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.severity"
29637c478bd9Sstevel@tonic-gatemsgstr "Critical"
29647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.description"
296525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
29667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.response"
296725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
29687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.impact"
296925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
29707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.action"
297125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
29727c478bd9Sstevel@tonic-gate#
29737c478bd9Sstevel@tonic-gate# code: SUN4U-8005-SH
29747c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
29757c478bd9Sstevel@tonic-gate#
29767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.type"
29777c478bd9Sstevel@tonic-gatemsgstr "Fault"
29787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.severity"
29797c478bd9Sstevel@tonic-gatemsgstr "Critical"
29807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.description"
298125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
29827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.response"
298325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
29847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.impact"
298525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
29867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.action"
298725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
29887c478bd9Sstevel@tonic-gate#
29897c478bd9Sstevel@tonic-gate# code: SUN4U-8005-T3
29907c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
29917c478bd9Sstevel@tonic-gate#
29927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.type"
29937c478bd9Sstevel@tonic-gatemsgstr "Fault"
29947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.severity"
29957c478bd9Sstevel@tonic-gatemsgstr "Critical"
29967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.description"
299725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
29987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.response"
299925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
30007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.impact"
300125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
30027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.action"
300325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
30047c478bd9Sstevel@tonic-gate#
30057c478bd9Sstevel@tonic-gate# code: SUN4U-8005-UY
30067c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho
30077c478bd9Sstevel@tonic-gate#
30087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.type"
30097c478bd9Sstevel@tonic-gatemsgstr "Fault"
30107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.severity"
30117c478bd9Sstevel@tonic-gatemsgstr "Critical"
30127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.description"
301325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
30147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.response"
301525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
30167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.impact"
301725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
30187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.action"
301925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
30207c478bd9Sstevel@tonic-gate#
30217c478bd9Sstevel@tonic-gate# code: SUN4U-8005-V5
30227c478bd9Sstevel@tonic-gate# keys: fault.io.tomatillo
30237c478bd9Sstevel@tonic-gate#
30247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.type"
30257c478bd9Sstevel@tonic-gatemsgstr "Fault"
30267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.severity"
30277c478bd9Sstevel@tonic-gatemsgstr "Critical"
30287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.description"
302925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
30307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.response"
303125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
30327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.impact"
303325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
30347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.action"
303525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
30367c478bd9Sstevel@tonic-gate#
30377c478bd9Sstevel@tonic-gate# code: SUN4U-8005-WS
30387c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.tomatillo
30397c478bd9Sstevel@tonic-gate#
30407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.type"
30417c478bd9Sstevel@tonic-gatemsgstr "Fault"
30427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.severity"
30437c478bd9Sstevel@tonic-gatemsgstr "Critical"
30447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.description"
304525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
30467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.response"
304725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
30487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.impact"
304925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
30507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.action"
305125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
30527c478bd9Sstevel@tonic-gate#
30537c478bd9Sstevel@tonic-gate# code: SUN4U-8005-XA
30547c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.tomatillo
30557c478bd9Sstevel@tonic-gate#
30567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.type"
30577c478bd9Sstevel@tonic-gatemsgstr "Fault"
30587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.severity"
30597c478bd9Sstevel@tonic-gatemsgstr "Critical"
30607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.description"
306125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
30627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.response"
306325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
30647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.impact"
306525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
30667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.action"
306725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
30687c478bd9Sstevel@tonic-gate#
30697c478bd9Sstevel@tonic-gate# code: SUN4U-8005-YP
30707c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo
30717c478bd9Sstevel@tonic-gate#
30727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.type"
30737c478bd9Sstevel@tonic-gatemsgstr "Fault"
30747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.severity"
30757c478bd9Sstevel@tonic-gatemsgstr "Critical"
30767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.description"
307725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
30787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.response"
307925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
30807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.impact"
308125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
30827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.action"
308325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
30847c478bd9Sstevel@tonic-gate#
30857c478bd9Sstevel@tonic-gate# code: SUN4U-8006-04
30867c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.tomatillo
30877c478bd9Sstevel@tonic-gate#
30887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.type"
30897c478bd9Sstevel@tonic-gatemsgstr "Fault"
30907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.severity"
30917c478bd9Sstevel@tonic-gatemsgstr "Critical"
30927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.description"
309325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
30947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.response"
309525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
30967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.impact"
309725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
30987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.action"
309925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
31007c478bd9Sstevel@tonic-gate#
31017c478bd9Sstevel@tonic-gate# code: SUN4U-8006-1R
31027c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo
31037c478bd9Sstevel@tonic-gate#
31047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.type"
31057c478bd9Sstevel@tonic-gatemsgstr "Fault"
31067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.severity"
31077c478bd9Sstevel@tonic-gatemsgstr "Critical"
31087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.description"
310925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
31107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.response"
311125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
31127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.impact"
311325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
31147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.action"
311525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
31167c478bd9Sstevel@tonic-gate#
31177c478bd9Sstevel@tonic-gate# code: SUN4U-8006-2C
31187c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.tomatillo
31197c478bd9Sstevel@tonic-gate#
31207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.type"
31217c478bd9Sstevel@tonic-gatemsgstr "Fault"
31227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.severity"
31237c478bd9Sstevel@tonic-gatemsgstr "Critical"
31247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.description"
312525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
31267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.response"
312725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
31287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.impact"
312925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
31307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.action"
313125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
31327c478bd9Sstevel@tonic-gate#
31337c478bd9Sstevel@tonic-gate# code: SUN4U-8006-3Q
31347c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo
31357c478bd9Sstevel@tonic-gate#
31367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.type"
31377c478bd9Sstevel@tonic-gatemsgstr "Fault"
31387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.severity"
31397c478bd9Sstevel@tonic-gatemsgstr "Critical"
31407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.description"
314125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
31427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.response"
314325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
31447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.impact"
314525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
31467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.action"
314725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
31487c478bd9Sstevel@tonic-gate#
31497c478bd9Sstevel@tonic-gate# code: SUN4U-8006-4E
31507c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.tomatillo
31517c478bd9Sstevel@tonic-gate#
31527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.type"
31537c478bd9Sstevel@tonic-gatemsgstr "Fault"
31547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.severity"
31557c478bd9Sstevel@tonic-gatemsgstr "Critical"
31567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.description"
315725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
31587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.response"
315925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
31607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.impact"
316125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
31627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.action"
316325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
31647c478bd9Sstevel@tonic-gate#
31657c478bd9Sstevel@tonic-gate# code: SUN4U-8006-5J
31667c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo
31677c478bd9Sstevel@tonic-gate#
31687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.type"
31697c478bd9Sstevel@tonic-gatemsgstr "Fault"
31707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.severity"
31717c478bd9Sstevel@tonic-gatemsgstr "Critical"
31727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.description"
317325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
31747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.response"
317525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
31767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.impact"
317725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
31787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.action"
317925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
31807c478bd9Sstevel@tonic-gate#
31817c478bd9Sstevel@tonic-gate# code: SUN4U-8006-62
31827c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo
31837c478bd9Sstevel@tonic-gate#
31847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.type"
31857c478bd9Sstevel@tonic-gatemsgstr "Fault"
31867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.severity"
31877c478bd9Sstevel@tonic-gatemsgstr "Critical"
31887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.description"
318925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
31907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.response"
319125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
31927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.impact"
319325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
31947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.action"
319525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
31967c478bd9Sstevel@tonic-gate#
31977c478bd9Sstevel@tonic-gate# code: SUN4U-8006-7X
31987c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo
31997c478bd9Sstevel@tonic-gate#
32007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.type"
32017c478bd9Sstevel@tonic-gatemsgstr "Fault"
32027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.severity"
32037c478bd9Sstevel@tonic-gatemsgstr "Critical"
32047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.description"
320525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
32067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.response"
320725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
32087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.impact"
320925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
32107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.action"
321125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
32127c478bd9Sstevel@tonic-gate#
32137c478bd9Sstevel@tonic-gate# code: SUN4U-8006-8P
32147c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo
32157c478bd9Sstevel@tonic-gate#
32167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.type"
32177c478bd9Sstevel@tonic-gatemsgstr "Fault"
32187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.severity"
32197c478bd9Sstevel@tonic-gatemsgstr "Critical"
32207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.description"
322125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
32227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.response"
322325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
32247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.impact"
322525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
32267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.action"
322725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
32287c478bd9Sstevel@tonic-gate#
32297c478bd9Sstevel@tonic-gate# code: SUN4U-8006-9A
32307c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo
32317c478bd9Sstevel@tonic-gate#
32327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.type"
32337c478bd9Sstevel@tonic-gatemsgstr "Fault"
32347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.severity"
32357c478bd9Sstevel@tonic-gatemsgstr "Critical"
32367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.description"
323725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
32387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.response"
323925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
32407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.impact"
324125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
32427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.action"
324325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
32447c478bd9Sstevel@tonic-gate#
32457c478bd9Sstevel@tonic-gate# code: SUN4U-8006-AS
32467c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo
32477c478bd9Sstevel@tonic-gate#
32487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.type"
32497c478bd9Sstevel@tonic-gatemsgstr "Fault"
32507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.severity"
32517c478bd9Sstevel@tonic-gatemsgstr "Critical"
32527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.description"
325325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
32547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.response"
325525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
32567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.impact"
325725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
32587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.action"
325925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
32607c478bd9Sstevel@tonic-gate#
32617c478bd9Sstevel@tonic-gate# code: SUN4U-8006-C5
32627c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo
32637c478bd9Sstevel@tonic-gate#
32647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.type"
32657c478bd9Sstevel@tonic-gatemsgstr "Fault"
32667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.severity"
32677c478bd9Sstevel@tonic-gatemsgstr "Critical"
32687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.description"
326925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
32707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.response"
327125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
32727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.impact"
327325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
32747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.action"
327525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
32767c478bd9Sstevel@tonic-gate#
32777c478bd9Sstevel@tonic-gate# code: SUN4U-8006-DY
32787c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.tomatillo
32797c478bd9Sstevel@tonic-gate#
32807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.type"
32817c478bd9Sstevel@tonic-gatemsgstr "Fault"
32827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.severity"
32837c478bd9Sstevel@tonic-gatemsgstr "Critical"
32847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.description"
328525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
32867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.response"
328725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
32887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.impact"
328925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
32907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.action"
329125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
32927c478bd9Sstevel@tonic-gate#
32937c478bd9Sstevel@tonic-gate# code: SUN4U-8006-E3
32947c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo
32957c478bd9Sstevel@tonic-gate#
32967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.type"
32977c478bd9Sstevel@tonic-gatemsgstr "Fault"
32987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.severity"
32997c478bd9Sstevel@tonic-gatemsgstr "Critical"
33007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.description"
330125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
33027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.response"
330325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
33047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.impact"
330525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
33067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.action"
330725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
33087c478bd9Sstevel@tonic-gate#
33097c478bd9Sstevel@tonic-gate# code: SUN4U-8006-FH
33107c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo
33117c478bd9Sstevel@tonic-gate#
33127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.type"
33137c478bd9Sstevel@tonic-gatemsgstr "Fault"
33147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.severity"
33157c478bd9Sstevel@tonic-gatemsgstr "Critical"
33167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.description"
331725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
33187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.response"
331925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
33207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.impact"
332125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
33227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.action"
332325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
33247c478bd9Sstevel@tonic-gate#
33257c478bd9Sstevel@tonic-gate# code: SUN4U-8006-GD
33267c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo
33277c478bd9Sstevel@tonic-gate#
33287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.type"
33297c478bd9Sstevel@tonic-gatemsgstr "Fault"
33307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.severity"
33317c478bd9Sstevel@tonic-gatemsgstr "Critical"
33327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.description"
333325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
33347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.response"
333525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
33367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.impact"
333725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
33387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.action"
333925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
33407c478bd9Sstevel@tonic-gate#
33417c478bd9Sstevel@tonic-gate# code: SUN4U-8006-HQ
33427c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo
33437c478bd9Sstevel@tonic-gate#
33447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.type"
33457c478bd9Sstevel@tonic-gatemsgstr "Fault"
33467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.severity"
33477c478bd9Sstevel@tonic-gatemsgstr "Critical"
33487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.description"
334925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
33507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.response"
335125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
33527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.impact"
335325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
33547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.action"
335525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
33567c478bd9Sstevel@tonic-gate#
33577c478bd9Sstevel@tonic-gate# code: SUN4U-8006-JC
33587c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo
33597c478bd9Sstevel@tonic-gate#
33607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.type"
33617c478bd9Sstevel@tonic-gatemsgstr "Fault"
33627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.severity"
33637c478bd9Sstevel@tonic-gatemsgstr "Critical"
33647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.description"
336525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
33667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.response"
336725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
33687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.impact"
336925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
33707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.action"
337125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
33727c478bd9Sstevel@tonic-gate#
33737c478bd9Sstevel@tonic-gate# code: SUN4U-8006-KR
33747c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo
33757c478bd9Sstevel@tonic-gate#
33767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.type"
33777c478bd9Sstevel@tonic-gatemsgstr "Fault"
33787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.severity"
33797c478bd9Sstevel@tonic-gatemsgstr "Critical"
33807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.description"
338125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
33827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.response"
338325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
33847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.impact"
338525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
33867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.action"
338725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
33887c478bd9Sstevel@tonic-gate#
33897c478bd9Sstevel@tonic-gate# code: SUN4U-8006-L4
33907c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo
33917c478bd9Sstevel@tonic-gate#
33927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.type"
33937c478bd9Sstevel@tonic-gatemsgstr "Fault"
33947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.severity"
33957c478bd9Sstevel@tonic-gatemsgstr "Critical"
33967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.description"
339725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
33987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.response"
339925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
34007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.impact"
340125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
34027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.action"
340325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
34047c478bd9Sstevel@tonic-gate#
34057c478bd9Sstevel@tonic-gate# code: SUN4U-8006-MX
34067c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
34077c478bd9Sstevel@tonic-gate#
34087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.type"
34097c478bd9Sstevel@tonic-gatemsgstr "Fault"
34107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.severity"
34117c478bd9Sstevel@tonic-gatemsgstr "Critical"
34127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.description"
341325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
34147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.response"
341525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
34167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.impact"
341725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
34187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.action"
341925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
34207c478bd9Sstevel@tonic-gate#
34217c478bd9Sstevel@tonic-gate# code: SUN4U-8006-N2
34227c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
34237c478bd9Sstevel@tonic-gate#
34247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.type"
34257c478bd9Sstevel@tonic-gatemsgstr "Fault"
34267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.severity"
34277c478bd9Sstevel@tonic-gatemsgstr "Critical"
34287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.description"
342925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
34307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.response"
343125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
34327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.impact"
343325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
34347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.action"
343525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
34367c478bd9Sstevel@tonic-gate#
34377c478bd9Sstevel@tonic-gate# code: SUN4U-8006-PJ
34387c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
34397c478bd9Sstevel@tonic-gate#
34407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.type"
34417c478bd9Sstevel@tonic-gatemsgstr "Fault"
34427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.severity"
34437c478bd9Sstevel@tonic-gatemsgstr "Critical"
34447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.description"
344525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
34467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.response"
344725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
34487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.impact"
344925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
34507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.action"
345125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
34527c478bd9Sstevel@tonic-gate#
34537c478bd9Sstevel@tonic-gate# code: SUN4U-8006-QE
34547c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
34557c478bd9Sstevel@tonic-gate#
34567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.type"
34577c478bd9Sstevel@tonic-gatemsgstr "Fault"
34587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.severity"
34597c478bd9Sstevel@tonic-gatemsgstr "Critical"
34607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.description"
346125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
34627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.response"
346325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
34647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.impact"
346525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
34667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.action"
346725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
34687c478bd9Sstevel@tonic-gate#
34697c478bd9Sstevel@tonic-gate# code: SUN4U-8006-R5
34707c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
34717c478bd9Sstevel@tonic-gate#
34727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.type"
34737c478bd9Sstevel@tonic-gatemsgstr "Fault"
34747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.severity"
34757c478bd9Sstevel@tonic-gatemsgstr "Critical"
34767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.description"
347725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
34787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.response"
347925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
34807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.impact"
348125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
34827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.action"
348325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
34847c478bd9Sstevel@tonic-gate#
34857c478bd9Sstevel@tonic-gate# code: SUN4U-8006-SS
34867c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
34877c478bd9Sstevel@tonic-gate#
34887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.type"
34897c478bd9Sstevel@tonic-gatemsgstr "Fault"
34907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.severity"
34917c478bd9Sstevel@tonic-gatemsgstr "Critical"
34927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.description"
349325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
34947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.response"
349525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
34967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.impact"
349725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
34987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.action"
349925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
35007c478bd9Sstevel@tonic-gate#
35017c478bd9Sstevel@tonic-gate# code: SUN4U-8006-TA
35027c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
35037c478bd9Sstevel@tonic-gate#
35047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.type"
35057c478bd9Sstevel@tonic-gatemsgstr "Fault"
35067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.severity"
35077c478bd9Sstevel@tonic-gatemsgstr "Critical"
35087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.description"
350925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n  Refer to %s for more information."
35107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.response"
351125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
35127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.impact"
351325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
35147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.action"
351525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device.  Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"
35167c478bd9Sstevel@tonic-gate#
35177c478bd9Sstevel@tonic-gate# code: SUN4U-8006-UP
35187c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo
35197c478bd9Sstevel@tonic-gate#
35207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.type"
35217c478bd9Sstevel@tonic-gatemsgstr "Fault"
35227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.severity"
35237c478bd9Sstevel@tonic-gatemsgstr "Critical"
35247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.description"
352525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n  Refer to %s for more information."
35267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.response"
352725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
35287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.impact"
352925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
35307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.action"
353125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s).  Schedule a repair of the most likely suspect \nlisted in the output.  If the most likely suspect is a package then run \npkgchk on the package(s).\n"
35327c478bd9Sstevel@tonic-gate#
35337c478bd9Sstevel@tonic-gate# code: SUN4U-8006-VD
35347c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.dcache
35357c478bd9Sstevel@tonic-gate#
35367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.type"
35377c478bd9Sstevel@tonic-gatemsgstr "Fault"
35387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.severity"
35397c478bd9Sstevel@tonic-gatemsgstr "Major"
35407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.description"
354125cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
35427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.response"
354325cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
35447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.impact"
354525cf1a30Sjl139090msgstr "System performance may be affected."
35467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.action"
354725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
35487c478bd9Sstevel@tonic-gate#
35497c478bd9Sstevel@tonic-gate# code: SUN4U-8006-WH
35507c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.icache
35517c478bd9Sstevel@tonic-gate#
35527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.type"
35537c478bd9Sstevel@tonic-gatemsgstr "Fault"
35547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.severity"
35557c478bd9Sstevel@tonic-gatemsgstr "Major"
35567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.description"
355725cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
35587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.response"
355925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
35607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.impact"
356125cf1a30Sjl139090msgstr "System performance may be affected."
35627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.action"
356325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
35647c478bd9Sstevel@tonic-gate#
35657c478bd9Sstevel@tonic-gate# code: SUN4U-8006-X3
35667c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachedata
35677c478bd9Sstevel@tonic-gate#
35687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.type"
35697c478bd9Sstevel@tonic-gatemsgstr "Fault"
35707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.severity"
35717c478bd9Sstevel@tonic-gatemsgstr "Major"
35727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.description"
357325cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
35747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.response"
357525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
35767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.impact"
357725cf1a30Sjl139090msgstr "System performance may be affected."
35787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.action"
357925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
35807c478bd9Sstevel@tonic-gate#
35817c478bd9Sstevel@tonic-gate# code: SUN4U-8006-YY
35827c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachetag
35837c478bd9Sstevel@tonic-gate#
35847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.type"
35857c478bd9Sstevel@tonic-gatemsgstr "Fault"
35867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.severity"
35877c478bd9Sstevel@tonic-gatemsgstr "Major"
35887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.description"
358925cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
35907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.response"
359125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
35927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.impact"
359325cf1a30Sjl139090msgstr "System performance may be affected."
35947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.action"
359525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
35967c478bd9Sstevel@tonic-gate#
35977c478bd9Sstevel@tonic-gate# code: SUN4U-8007-03
35987c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.fpu
35997c478bd9Sstevel@tonic-gate#
36007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.type"
36017c478bd9Sstevel@tonic-gatemsgstr "Fault"
36027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.severity"
36037c478bd9Sstevel@tonic-gatemsgstr "Major"
36047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.description"
360525cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels.  Refer to %s for more information."
36067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.response"
360725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service."
36087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.impact"
360925cf1a30Sjl139090msgstr "System performance may be affected."
36107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.action"
361125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
3612d00f0155Sayznaga#
3613d00f0155Sayznaga# code: SUN4U-8007-1Y
3614d00f0155Sayznaga# keys: fault.asic.cds.dp
3615d00f0155Sayznaga#
3616d00f0155Sayznagamsgid "SUN4U-8007-1Y.type"
3617d00f0155Sayznagamsgstr "Fault"
3618d00f0155Sayznagamsgid "SUN4U-8007-1Y.severity"
3619d00f0155Sayznagamsgstr "Critical"
3620d00f0155Sayznagamsgid "SUN4U-8007-1Y.description"
362125cf1a30Sjl139090msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3622d00f0155Sayznagamsgid "SUN4U-8007-1Y.response"
362325cf1a30Sjl139090msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3624d00f0155Sayznagamsgid "SUN4U-8007-1Y.impact"
362525cf1a30Sjl139090msgstr "System performace may be affected.\n"
3626d00f0155Sayznagamsgid "SUN4U-8007-1Y.action"
362725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3628d00f0155Sayznaga#
3629d00f0155Sayznaga# code: SUN4U-8007-2D
3630d00f0155Sayznaga# keys: fault.asic.dx.dp
3631d00f0155Sayznaga#
3632d00f0155Sayznagamsgid "SUN4U-8007-2D.type"
3633d00f0155Sayznagamsgstr "Fault"
3634d00f0155Sayznagamsgid "SUN4U-8007-2D.severity"
3635d00f0155Sayznagamsgstr "Critical"
3636d00f0155Sayznagamsgid "SUN4U-8007-2D.description"
363725cf1a30Sjl139090msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3638d00f0155Sayznagamsgid "SUN4U-8007-2D.response"
363925cf1a30Sjl139090msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3640d00f0155Sayznagamsgid "SUN4U-8007-2D.impact"
364125cf1a30Sjl139090msgstr "System performace may be affected.\n"
3642d00f0155Sayznagamsgid "SUN4U-8007-2D.action"
364325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3644d00f0155Sayznaga#
3645d00f0155Sayznaga# code: SUN4U-8007-3H
3646d00f0155Sayznaga# keys: fault.asic.sdi.dp
3647d00f0155Sayznaga#
3648d00f0155Sayznagamsgid "SUN4U-8007-3H.type"
3649d00f0155Sayznagamsgstr "Fault"
3650d00f0155Sayznagamsgid "SUN4U-8007-3H.severity"
3651d00f0155Sayznagamsgstr "Critical"
3652d00f0155Sayznagamsgid "SUN4U-8007-3H.description"
365325cf1a30Sjl139090msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3654d00f0155Sayznagamsgid "SUN4U-8007-3H.response"
365525cf1a30Sjl139090msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3656d00f0155Sayznagamsgid "SUN4U-8007-3H.impact"
365725cf1a30Sjl139090msgstr "System performace may be affected.\n"
3658d00f0155Sayznagamsgid "SUN4U-8007-3H.action"
365925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3660d00f0155Sayznaga#
3661d00f0155Sayznaga# code: SUN4U-8007-4A
3662d00f0155Sayznaga# keys: fault.asic.cp.dp
3663d00f0155Sayznaga#
3664d00f0155Sayznagamsgid "SUN4U-8007-4A.type"
3665d00f0155Sayznagamsgstr "Fault"
3666d00f0155Sayznagamsgid "SUN4U-8007-4A.severity"
3667d00f0155Sayznagamsgstr "Critical"
3668d00f0155Sayznagamsgid "SUN4U-8007-4A.description"
366925cf1a30Sjl139090msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3670d00f0155Sayznagamsgid "SUN4U-8007-4A.response"
367125cf1a30Sjl139090msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3672d00f0155Sayznagamsgid "SUN4U-8007-4A.impact"
367325cf1a30Sjl139090msgstr "System performace may be affected.\n"
3674d00f0155Sayznagamsgid "SUN4U-8007-4A.action"
367525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
3676d00f0155Sayznaga#
3677d00f0155Sayznaga# code: SUN4U-8007-5P
3678d00f0155Sayznaga# keys: fault.asic.rp.dp
3679d00f0155Sayznaga#
3680d00f0155Sayznagamsgid "SUN4U-8007-5P.type"
3681d00f0155Sayznagamsgstr "Fault"
3682d00f0155Sayznagamsgid "SUN4U-8007-5P.severity"
3683d00f0155Sayznagamsgstr "Critical"
3684d00f0155Sayznagamsgid "SUN4U-8007-5P.description"
368525cf1a30Sjl139090msgstr "A hardware problem was detected on the datapath interconnect.\n  Refer to %s for more information."
3686d00f0155Sayznagamsgid "SUN4U-8007-5P.response"
368725cf1a30Sjl139090msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n"
3688d00f0155Sayznagamsgid "SUN4U-8007-5P.impact"
368925cf1a30Sjl139090msgstr "System performace may be affected.\n"
3690d00f0155Sayznagamsgid "SUN4U-8007-5P.action"
369125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n"
369225cf1a30Sjl139090#
369325cf1a30Sjl139090# code: SUN4U-8007-65
369425cf1a30Sjl139090# keys: fault.io.oberon
369525cf1a30Sjl139090#
369625cf1a30Sjl139090msgid "SUN4U-8007-65.type"
369725cf1a30Sjl139090msgstr "Fault"
369825cf1a30Sjl139090msgid "SUN4U-8007-65.severity"
369925cf1a30Sjl139090msgstr "Critical"
370025cf1a30Sjl139090msgid "SUN4U-8007-65.description"
370125cf1a30Sjl139090msgstr "Oberon PCI-Express hostbridge fault\n  Refer to %s for more information."
370225cf1a30Sjl139090msgid "SUN4U-8007-65.response"
370325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent."
370425cf1a30Sjl139090msgid "SUN4U-8007-65.impact"
370525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime."
370625cf1a30Sjl139090msgid "SUN4U-8007-65.action"
370725cf1a30Sjl139090msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support."
370825cf1a30Sjl139090#
370925cf1a30Sjl139090# code: SUN4U-8007-7S
371025cf1a30Sjl139090# keys: fault.cpu.SPARC64-VI.chip
371125cf1a30Sjl139090#
371225cf1a30Sjl139090msgid "SUN4U-8007-7S.type"
371325cf1a30Sjl139090msgstr "Fault"
371425cf1a30Sjl139090msgid "SUN4U-8007-7S.severity"
371525cf1a30Sjl139090msgstr "Critical"
371625cf1a30Sjl139090msgid "SUN4U-8007-7S.description"
3717*9dd0f810Scindimsgstr "The number of errors associated with this CHIP has exceeded acceptable levels.\nRefer to %s for more information.  Refer to %s for more information."
371825cf1a30Sjl139090msgid "SUN4U-8007-7S.response"
3719*9dd0f810Scindimsgstr "An attempt will be made to remove the affected CHIP from service."
372025cf1a30Sjl139090msgid "SUN4U-8007-7S.impact"
3721*9dd0f810Scindimsgstr "The system will not be functioning at the same performance level with the CHIP removal."
372225cf1a30Sjl139090msgid "SUN4U-8007-7S.action"
3723*9dd0f810Scindimsgstr "Schedule a repair procedure to replace the affected CHIP.  Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nCHIP."
372425cf1a30Sjl139090#
372525cf1a30Sjl139090# code: SUN4U-8007-8J
372625cf1a30Sjl139090# keys: fault.cpu.SPARC64-VI.core
372725cf1a30Sjl139090#
372825cf1a30Sjl139090msgid "SUN4U-8007-8J.type"
372925cf1a30Sjl139090msgstr "Fault"
373025cf1a30Sjl139090msgid "SUN4U-8007-8J.severity"
373125cf1a30Sjl139090msgstr "Critical"
373225cf1a30Sjl139090msgid "SUN4U-8007-8J.description"
3733*9dd0f810Scindimsgstr "The number of errors associated with this CHIP has exceeded acceptable levels.\nRefer to %s for more information.  Refer to %s for more information."
373425cf1a30Sjl139090msgid "SUN4U-8007-8J.response"
3735*9dd0f810Scindimsgstr "An attempt will be made to remove the affected CORE from service."
373625cf1a30Sjl139090msgid "SUN4U-8007-8J.impact"
3737*9dd0f810Scindimsgstr "The system will not be functioning at the same performance level with the CORE removal."
373825cf1a30Sjl139090msgid "SUN4U-8007-8J.action"
3739*9dd0f810Scindimsgstr "Schedule a repair procedure to replace the affected CORE.  Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nCORE.\n"
374025cf1a30Sjl139090#
374125cf1a30Sjl139090# code: SUN4U-8007-9E
374225cf1a30Sjl139090# keys: fault.cpu.SPARC64-VI.strand
374325cf1a30Sjl139090#
374425cf1a30Sjl139090msgid "SUN4U-8007-9E.type"
374525cf1a30Sjl139090msgstr "Fault"
374625cf1a30Sjl139090msgid "SUN4U-8007-9E.severity"
374725cf1a30Sjl139090msgstr "Critical"
374825cf1a30Sjl139090msgid "SUN4U-8007-9E.description"
3749*9dd0f810Scindimsgstr "The number of errors associated with this STRAND has exceeded acceptable levels.\nRefer to %s for more information.  Refer to %s for more information."
375025cf1a30Sjl139090msgid "SUN4U-8007-9E.response"
3751*9dd0f810Scindimsgstr "An attempt will be made to remove the affected STRAND from service."
375225cf1a30Sjl139090msgid "SUN4U-8007-9E.impact"
3753*9dd0f810Scindimsgstr "The system will not be functioning at the same performance level with the STRAND removal."
375425cf1a30Sjl139090msgid "SUN4U-8007-9E.action"
3755*9dd0f810Scindimsgstr "Schedule a repair procedure to replace the affected STRAND.  Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nSTRAND.\n"
375600d0963fSdilpreet#
375700d0963fSdilpreet# code: SUN4U-8007-AX
375800d0963fSdilpreet# keys: fault.io.pci.device-invreq fault.io.tomatillo
375900d0963fSdilpreet#
376000d0963fSdilpreetmsgid "SUN4U-8007-AX.type"
376100d0963fSdilpreetmsgstr "Fault"
376200d0963fSdilpreetmsgid "SUN4U-8007-AX.severity"
376300d0963fSdilpreetmsgstr "Critical"
376400d0963fSdilpreetmsgid "SUN4U-8007-AX.description"
376500d0963fSdilpreetmsgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n  Refer to %s for more information."
376600d0963fSdilpreetmsgid "SUN4U-8007-AX.response"
376700d0963fSdilpreetmsgstr "One or more device instances may be disabled\n"
376800d0963fSdilpreetmsgid "SUN4U-8007-AX.impact"
376900d0963fSdilpreetmsgstr "Loss of services provided by the device instances associated with this fault\n"
377000d0963fSdilpreetmsgid "SUN4U-8007-AX.action"
3771*9dd0f810Scindimsgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins.  Otherwise schedule a repair procedure to replace the affected device(s).  Use fmdump -v -u <EVENT_ID> to identify the devices or contact Sun for support.\n"