17c478bd9Sstevel@tonic-gate# 225cf1a30Sjl139090# Copyright 2006 Sun Microsystems, Inc. All rights reserved. 37c478bd9Sstevel@tonic-gate# Use is subject to license terms. 47c478bd9Sstevel@tonic-gate# 57c478bd9Sstevel@tonic-gate# CDDL HEADER START 67c478bd9Sstevel@tonic-gate# 77c478bd9Sstevel@tonic-gate# The contents of this file are subject to the terms of the 825cf1a30Sjl139090# Common Development and Distribution License (the "License"). 925cf1a30Sjl139090# You may not use this file except in compliance with the License. 107c478bd9Sstevel@tonic-gate# 117c478bd9Sstevel@tonic-gate# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 127c478bd9Sstevel@tonic-gate# or http://www.opensolaris.org/os/licensing. 137c478bd9Sstevel@tonic-gate# See the License for the specific language governing permissions 147c478bd9Sstevel@tonic-gate# and limitations under the License. 157c478bd9Sstevel@tonic-gate# 167c478bd9Sstevel@tonic-gate# When distributing Covered Code, include this CDDL HEADER in each 177c478bd9Sstevel@tonic-gate# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 187c478bd9Sstevel@tonic-gate# If applicable, add the following below this CDDL HEADER, with the 197c478bd9Sstevel@tonic-gate# fields enclosed by brackets "[]" replaced with your own identifying 207c478bd9Sstevel@tonic-gate# information: Portions Copyright [yyyy] [name of copyright owner] 217c478bd9Sstevel@tonic-gate# 227c478bd9Sstevel@tonic-gate# CDDL HEADER END 237c478bd9Sstevel@tonic-gate# 247c478bd9Sstevel@tonic-gate#ident "%Z%%M% %I% %E% SMI" 2525cf1a30Sjl139090# 2625cf1a30Sjl139090# DO NOT EDIT -- this file is generated by the Event Registry. 2725cf1a30Sjl139090# 287c478bd9Sstevel@tonic-gate# 297c478bd9Sstevel@tonic-gate# code: SUN4U-8000-1A 307c478bd9Sstevel@tonic-gate# keys: fault.memory.page 317c478bd9Sstevel@tonic-gate# 327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.type" 337c478bd9Sstevel@tonic-gatemsgstr "Fault" 347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.severity" 357c478bd9Sstevel@tonic-gatemsgstr "Minor" 367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.description" 377c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this memory module continues to exceed acceptable levels. Refer to %s for more information." 387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.response" 397c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove this memory page from service." 407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.impact" 417c478bd9Sstevel@tonic-gatemsgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation." 427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-1A.action" 437c478bd9Sstevel@tonic-gatemsgstr "No repair action is recommended at this time." 447c478bd9Sstevel@tonic-gate# 457c478bd9Sstevel@tonic-gate# code: SUN4U-8000-2S 467c478bd9Sstevel@tonic-gate# keys: fault.memory.dimm 477c478bd9Sstevel@tonic-gate# 487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.type" 497c478bd9Sstevel@tonic-gatemsgstr "Fault" 507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.severity" 5125cf1a30Sjl139090msgstr "Major" 527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.description" 537c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." 547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.response" 557c478bd9Sstevel@tonic-gatemsgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.impact" 577c478bd9Sstevel@tonic-gatemsgstr "Total system memory capacity will be reduced as pages are retired." 587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-2S.action" 597c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module." 607c478bd9Sstevel@tonic-gate# 617c478bd9Sstevel@tonic-gate# code: SUN4U-8000-35 627c478bd9Sstevel@tonic-gate# keys: fault.memory.bank 637c478bd9Sstevel@tonic-gate# 647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.type" 657c478bd9Sstevel@tonic-gatemsgstr "Fault" 667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.severity" 6725cf1a30Sjl139090msgstr "Critical" 687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.description" 697c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." 707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.response" 717c478bd9Sstevel@tonic-gatemsgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.impact" 737c478bd9Sstevel@tonic-gatemsgstr "Total system memory capacity will be reduced as pages are retired." 747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-35.action" 757c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module." 767c478bd9Sstevel@tonic-gate# 777c478bd9Sstevel@tonic-gate# code: SUN4U-8000-4Y 787c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.dcache 797c478bd9Sstevel@tonic-gate# 807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.type" 817c478bd9Sstevel@tonic-gatemsgstr "Fault" 827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.severity" 837c478bd9Sstevel@tonic-gatemsgstr "Major" 847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.description" 8525cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.response" 8725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.impact" 8925cf1a30Sjl139090msgstr "System performance may be affected." 907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-4Y.action" 9125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 927c478bd9Sstevel@tonic-gate# 937c478bd9Sstevel@tonic-gate# code: SUN4U-8000-53 947c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.icache 957c478bd9Sstevel@tonic-gate# 967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.type" 977c478bd9Sstevel@tonic-gatemsgstr "Fault" 987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.severity" 997c478bd9Sstevel@tonic-gatemsgstr "Major" 1007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.description" 10125cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 1027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.response" 10325cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 1047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.impact" 10525cf1a30Sjl139090msgstr "System performance may be affected." 1067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-53.action" 10725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 1087c478bd9Sstevel@tonic-gate# 1097c478bd9Sstevel@tonic-gate# code: SUN4U-8000-6H 1107c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.l2cachedata 1117c478bd9Sstevel@tonic-gate# 1127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.type" 1137c478bd9Sstevel@tonic-gatemsgstr "Fault" 1147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.severity" 1157c478bd9Sstevel@tonic-gatemsgstr "Major" 1167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.description" 1177c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 1187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.response" 11925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 1207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.impact" 12125cf1a30Sjl139090msgstr "System performance may be affected." 1227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-6H.action" 12325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 1247c478bd9Sstevel@tonic-gate# 1257c478bd9Sstevel@tonic-gate# code: SUN4U-8000-7D 1267c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.l2cachetag 1277c478bd9Sstevel@tonic-gate# 1287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.type" 1297c478bd9Sstevel@tonic-gatemsgstr "Fault" 1307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.severity" 1317c478bd9Sstevel@tonic-gatemsgstr "Major" 1327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.description" 1337c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 1347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.response" 13525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 1367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.impact" 13725cf1a30Sjl139090msgstr "System performance may be affected." 1387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-7D.action" 13925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 1407c478bd9Sstevel@tonic-gate# 1417c478bd9Sstevel@tonic-gate# code: SUN4U-8000-84 1427c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.dcache 1437c478bd9Sstevel@tonic-gate# 1447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.type" 1457c478bd9Sstevel@tonic-gatemsgstr "Fault" 1467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.severity" 1477c478bd9Sstevel@tonic-gatemsgstr "Major" 1487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.description" 1497c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 1507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.response" 15125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 1527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.impact" 15325cf1a30Sjl139090msgstr "System performance system may be affected." 1547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-84.action" 15525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 1567c478bd9Sstevel@tonic-gate# 1577c478bd9Sstevel@tonic-gate# code: SUN4U-8000-9R 1587c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.icache 1597c478bd9Sstevel@tonic-gate# 1607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.type" 1617c478bd9Sstevel@tonic-gatemsgstr "Fault" 1627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.severity" 1637c478bd9Sstevel@tonic-gatemsgstr "Major" 1647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.description" 1657c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 1667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.response" 16725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 1687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.impact" 16925cf1a30Sjl139090msgstr "System performance may be affected." 1707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-9R.action" 17125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 1727c478bd9Sstevel@tonic-gate# 1737c478bd9Sstevel@tonic-gate# code: SUN4U-8000-AC 1747c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.l2cachedata 1757c478bd9Sstevel@tonic-gate# 1767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.type" 1777c478bd9Sstevel@tonic-gatemsgstr "Fault" 1787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.severity" 1797c478bd9Sstevel@tonic-gatemsgstr "Major" 1807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.description" 1817c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 1827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.response" 18325cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 1847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.impact" 18525cf1a30Sjl139090msgstr "System performance may be affected." 1867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-AC.action" 18725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 1887c478bd9Sstevel@tonic-gate# 1897c478bd9Sstevel@tonic-gate# code: SUN4U-8000-CQ 1907c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.l2cachetag 1917c478bd9Sstevel@tonic-gate# 1927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.type" 1937c478bd9Sstevel@tonic-gatemsgstr "Fault" 1947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.severity" 1957c478bd9Sstevel@tonic-gatemsgstr "Major" 1967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.description" 1977c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 1987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.response" 19925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 2007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.impact" 20125cf1a30Sjl139090msgstr "System performance may be affected." 2027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-CQ.action" 20325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 2047c478bd9Sstevel@tonic-gate# 2057c478bd9Sstevel@tonic-gate# code: SUN4U-8000-DE 2067c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.dcache 2077c478bd9Sstevel@tonic-gate# 2087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.type" 2097c478bd9Sstevel@tonic-gatemsgstr "Fault" 2107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.severity" 2117c478bd9Sstevel@tonic-gatemsgstr "Major" 2127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.description" 2137c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 2147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.response" 21525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 2167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.impact" 21725cf1a30Sjl139090msgstr "System performance may be affected." 2187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-DE.action" 21925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 2207c478bd9Sstevel@tonic-gate# 2217c478bd9Sstevel@tonic-gate# code: SUN4U-8000-EJ 2227c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.icache 2237c478bd9Sstevel@tonic-gate# 2247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.type" 2257c478bd9Sstevel@tonic-gatemsgstr "Fault" 2267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.severity" 2277c478bd9Sstevel@tonic-gatemsgstr "Major" 2287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.description" 2297c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 2307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.response" 23125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 2327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.impact" 23325cf1a30Sjl139090msgstr "System performance may be affected." 2347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-EJ.action" 23525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 2367c478bd9Sstevel@tonic-gate# 2377c478bd9Sstevel@tonic-gate# code: SUN4U-8000-F2 2387c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.l2cachedata 2397c478bd9Sstevel@tonic-gate# 2407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.type" 2417c478bd9Sstevel@tonic-gatemsgstr "Fault" 2427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.severity" 2437c478bd9Sstevel@tonic-gatemsgstr "Major" 2447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.description" 2457c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 2467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.response" 24725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 2487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.impact" 24925cf1a30Sjl139090msgstr "System performance may be affected." 2507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-F2.action" 25125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 2527c478bd9Sstevel@tonic-gate# 2537c478bd9Sstevel@tonic-gate# code: SUN4U-8000-GX 2547c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.l2cachetag 2557c478bd9Sstevel@tonic-gate# 2567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.type" 2577c478bd9Sstevel@tonic-gatemsgstr "Fault" 2587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.severity" 2597c478bd9Sstevel@tonic-gatemsgstr "Major" 2607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.description" 2617c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 2627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.response" 2637c478bd9Sstevel@tonic-gatemsgstr "An attempt will be made to remove the affected CPU from service." 2647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.impact" 26525cf1a30Sjl139090msgstr "System performance may be affected." 2667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-GX.action" 2677c478bd9Sstevel@tonic-gatemsgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u <EVENT_ID> to identify the CPU." 2687c478bd9Sstevel@tonic-gate# 2697c478bd9Sstevel@tonic-gate# code: SUN4U-8000-H5 2707c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.dcache 2717c478bd9Sstevel@tonic-gate# 2727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.type" 2737c478bd9Sstevel@tonic-gatemsgstr "Fault" 2747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.severity" 2757c478bd9Sstevel@tonic-gatemsgstr "Major" 2767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.description" 2777c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 2787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.response" 27925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 2807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.impact" 28125cf1a30Sjl139090msgstr "System performance may be affected." 2827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-H5.action" 28325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 2847c478bd9Sstevel@tonic-gate# 2857c478bd9Sstevel@tonic-gate# code: SUN4U-8000-JS 2867c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.icache 2877c478bd9Sstevel@tonic-gate# 2887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.type" 2897c478bd9Sstevel@tonic-gatemsgstr "Fault" 2907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.severity" 2917c478bd9Sstevel@tonic-gatemsgstr "Major" 2927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.description" 2937c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 2947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.response" 29525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 2967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.impact" 29725cf1a30Sjl139090msgstr "System performance may be affected." 2987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-JS.action" 29925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3007c478bd9Sstevel@tonic-gate# 3017c478bd9Sstevel@tonic-gate# code: SUN4U-8000-KA 3027c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.l2cachedata 3037c478bd9Sstevel@tonic-gate# 3047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.type" 3057c478bd9Sstevel@tonic-gatemsgstr "Fault" 3067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.severity" 3077c478bd9Sstevel@tonic-gatemsgstr "Major" 3087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.description" 3097c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 3107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.response" 31125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 3127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.impact" 31325cf1a30Sjl139090msgstr "System performance may be affected." 3147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-KA.action" 31525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3167c478bd9Sstevel@tonic-gate# 3177c478bd9Sstevel@tonic-gate# code: SUN4U-8000-LP 3187c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.l2cachetag 3197c478bd9Sstevel@tonic-gate# 3207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.type" 3217c478bd9Sstevel@tonic-gatemsgstr "Fault" 3227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.severity" 3237c478bd9Sstevel@tonic-gatemsgstr "Major" 3247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.description" 3257c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 3267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.response" 32725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 3287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.impact" 32925cf1a30Sjl139090msgstr "System performance may be affected." 3307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-LP.action" 33125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3327c478bd9Sstevel@tonic-gate# 3337c478bd9Sstevel@tonic-gate# code: SUN4U-8000-MD 3347c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-III.fpu 3357c478bd9Sstevel@tonic-gate# 3367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.type" 3377c478bd9Sstevel@tonic-gatemsgstr "Fault" 3387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.severity" 3397c478bd9Sstevel@tonic-gatemsgstr "Major" 3407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.description" 3417c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." 3427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.response" 34325cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 3447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.impact" 34525cf1a30Sjl139090msgstr "System performance may be affected." 3467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-MD.action" 34725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3487c478bd9Sstevel@tonic-gate# 3497c478bd9Sstevel@tonic-gate# code: SUN4U-8000-NH 3507c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIi.fpu 3517c478bd9Sstevel@tonic-gate# 3527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.type" 3537c478bd9Sstevel@tonic-gatemsgstr "Fault" 3547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.severity" 3557c478bd9Sstevel@tonic-gatemsgstr "Major" 3567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.description" 3577c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." 3587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.response" 35925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 3607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.impact" 36125cf1a30Sjl139090msgstr "System performance may be affected." 3627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-NH.action" 36325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3647c478bd9Sstevel@tonic-gate# 3657c478bd9Sstevel@tonic-gate# code: SUN4U-8000-P3 3667c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIplus.fpu 3677c478bd9Sstevel@tonic-gate# 3687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.type" 3697c478bd9Sstevel@tonic-gatemsgstr "Fault" 3707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.severity" 3717c478bd9Sstevel@tonic-gatemsgstr "Major" 3727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.description" 3737c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." 3747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.response" 37525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 3767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.impact" 37725cf1a30Sjl139090msgstr "System performance may be affected." 3787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-P3.action" 37925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3807c478bd9Sstevel@tonic-gate# 3817c478bd9Sstevel@tonic-gate# code: SUN4U-8000-QY 3827c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IV.fpu 3837c478bd9Sstevel@tonic-gate# 3847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.type" 3857c478bd9Sstevel@tonic-gatemsgstr "Fault" 3867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.severity" 3877c478bd9Sstevel@tonic-gatemsgstr "Major" 3887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.description" 3897c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." 3907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.response" 39125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 3927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.impact" 39325cf1a30Sjl139090msgstr "System performance may be affected." 3947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-QY.action" 39525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3967c478bd9Sstevel@tonic-gate# 3977c478bd9Sstevel@tonic-gate# code: SUN4U-8000-RQ 3987c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.fpu 3997c478bd9Sstevel@tonic-gate# 4007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.type" 4017c478bd9Sstevel@tonic-gatemsgstr "Fault" 4027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.severity" 4037c478bd9Sstevel@tonic-gatemsgstr "Major" 4047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.description" 4057c478bd9Sstevel@tonic-gatemsgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." 4067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.response" 40725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 4087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.impact" 40925cf1a30Sjl139090msgstr "System performance may be affected." 4107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-RQ.action" 41125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 4127c478bd9Sstevel@tonic-gate# 4137c478bd9Sstevel@tonic-gate# code: SUN4U-8000-SC 4147c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.dcache 4157c478bd9Sstevel@tonic-gate# 4167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.type" 4177c478bd9Sstevel@tonic-gatemsgstr "Fault" 4187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.severity" 4197c478bd9Sstevel@tonic-gatemsgstr "Major" 4207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.description" 4217c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 4227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.response" 42325cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 4247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.impact" 42525cf1a30Sjl139090msgstr "System performance may be affected." 4267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-SC.action" 42725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 4287c478bd9Sstevel@tonic-gate# 4297c478bd9Sstevel@tonic-gate# code: SUN4U-8000-TR 4307c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.icache 4317c478bd9Sstevel@tonic-gate# 4327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.type" 4337c478bd9Sstevel@tonic-gatemsgstr "Fault" 4347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.severity" 4357c478bd9Sstevel@tonic-gatemsgstr "Major" 4367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.description" 4377c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 4387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.response" 43925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 4407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.impact" 44125cf1a30Sjl139090msgstr "System performance may be affected." 4427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-TR.action" 44325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 4447c478bd9Sstevel@tonic-gate# 4457c478bd9Sstevel@tonic-gate# code: SUN4U-8000-U4 4467c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.pcache 4477c478bd9Sstevel@tonic-gate# 4487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.type" 4497c478bd9Sstevel@tonic-gatemsgstr "Fault" 4507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.severity" 4517c478bd9Sstevel@tonic-gatemsgstr "Major" 4527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.description" 4537c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 4547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.response" 45525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 4567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.impact" 45725cf1a30Sjl139090msgstr "System performance may be affected." 4587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-U4.action" 45925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 4607c478bd9Sstevel@tonic-gate# 4617c478bd9Sstevel@tonic-gate# code: SUN4U-8000-VX 4627c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.dtlb 4637c478bd9Sstevel@tonic-gate# 4647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.type" 4657c478bd9Sstevel@tonic-gatemsgstr "Fault" 4667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.severity" 4677c478bd9Sstevel@tonic-gatemsgstr "Major" 4687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.description" 4697c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 4707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.response" 47125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 4727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.impact" 47325cf1a30Sjl139090msgstr "System performance may be affected." 4747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-VX.action" 47525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 4767c478bd9Sstevel@tonic-gate# 4777c478bd9Sstevel@tonic-gate# code: SUN4U-8000-W2 4787c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.itlb 4797c478bd9Sstevel@tonic-gate# 4807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.type" 4817c478bd9Sstevel@tonic-gatemsgstr "Fault" 4827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.severity" 4837c478bd9Sstevel@tonic-gatemsgstr "Major" 4847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.description" 4857c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 4867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.response" 48725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 4887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.impact" 48925cf1a30Sjl139090msgstr "System performance may be affected." 4907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-W2.action" 49125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 4927c478bd9Sstevel@tonic-gate# 4937c478bd9Sstevel@tonic-gate# code: SUN4U-8000-XJ 4947c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.l2cachedata 4957c478bd9Sstevel@tonic-gate# 4967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.type" 4977c478bd9Sstevel@tonic-gatemsgstr "Fault" 4987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.severity" 4997c478bd9Sstevel@tonic-gatemsgstr "Major" 5007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.description" 5017c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 5027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.response" 50325cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 5047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.impact" 50525cf1a30Sjl139090msgstr "System performance may be affected." 5067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-XJ.action" 50725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 5087c478bd9Sstevel@tonic-gate# 5097c478bd9Sstevel@tonic-gate# code: SUN4U-8000-YE 5107c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.l2cachetag 5117c478bd9Sstevel@tonic-gate# 5127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.type" 5137c478bd9Sstevel@tonic-gatemsgstr "Fault" 5147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.severity" 5157c478bd9Sstevel@tonic-gatemsgstr "Major" 5167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.description" 5177c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 5187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.response" 51925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 5207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.impact" 52125cf1a30Sjl139090msgstr "System performance may be affected." 5227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8000-YE.action" 52325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 5247c478bd9Sstevel@tonic-gate# 5257c478bd9Sstevel@tonic-gate# code: SUN4U-8001-0J 5267c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.l3cachedata 5277c478bd9Sstevel@tonic-gate# 5287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.type" 5297c478bd9Sstevel@tonic-gatemsgstr "Fault" 5307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.severity" 5317c478bd9Sstevel@tonic-gatemsgstr "Major" 5327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.description" 5337c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 5347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.response" 53525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 5367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.impact" 53725cf1a30Sjl139090msgstr "System performance may be affected." 5387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-0J.action" 53925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 5407c478bd9Sstevel@tonic-gate# 5417c478bd9Sstevel@tonic-gate# code: SUN4U-8001-1E 5427c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IVplus.l3cachetag 5437c478bd9Sstevel@tonic-gate# 5447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.type" 5457c478bd9Sstevel@tonic-gatemsgstr "Fault" 5467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.severity" 5477c478bd9Sstevel@tonic-gatemsgstr "Major" 5487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.description" 5497c478bd9Sstevel@tonic-gatemsgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." 5507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.response" 55125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 5527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.impact" 55325cf1a30Sjl139090msgstr "System performance may be affected." 5547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-1E.action" 55525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 5567c478bd9Sstevel@tonic-gate# 5577c478bd9Sstevel@tonic-gate# code: SUN4U-8001-2X 5587c478bd9Sstevel@tonic-gate# keys: defect.ultraSPARC-II.memory.nodiag 5597c478bd9Sstevel@tonic-gate# 5607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.type" 5617c478bd9Sstevel@tonic-gatemsgstr "Defect" 5627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.severity" 5637c478bd9Sstevel@tonic-gatemsgstr "Minor" 5647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.description" 56525cf1a30Sjl139090msgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information." 5667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.response" 5677c478bd9Sstevel@tonic-gatemsgstr "The error information has been saved for examination by Sun." 5687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.impact" 5697c478bd9Sstevel@tonic-gatemsgstr "The error log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." 5707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-2X.action" 5717c478bd9Sstevel@tonic-gatemsgstr "Use fmdump -ev -u <EVENT-ID> to view and record the undiagnosed errors." 5727c478bd9Sstevel@tonic-gate# 5737c478bd9Sstevel@tonic-gate# code: SUN4U-8001-32 5747c478bd9Sstevel@tonic-gate# keys: fault.memory.datapath 5757c478bd9Sstevel@tonic-gate# 5767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.type" 5777c478bd9Sstevel@tonic-gatemsgstr "Fault" 5787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.severity" 5797c478bd9Sstevel@tonic-gatemsgstr "Major" 5807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.description" 5817c478bd9Sstevel@tonic-gatemsgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system. Refer to %s for more information." 5827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.response" 5837c478bd9Sstevel@tonic-gatemsgstr "Error reports from the affected components will be logged for examination by Sun." 5847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.impact" 5857c478bd9Sstevel@tonic-gatemsgstr "System performance and stability may be affected." 5867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-32.action" 5877c478bd9Sstevel@tonic-gatemsgstr "Contact your service provider for further diagnosis." 5887c478bd9Sstevel@tonic-gate# 5897c478bd9Sstevel@tonic-gate# code: SUN4U-8001-4R 5907c478bd9Sstevel@tonic-gate# keys: fault.io.datapath 5917c478bd9Sstevel@tonic-gate# 5927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.type" 5937c478bd9Sstevel@tonic-gatemsgstr "Fault" 5947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.severity" 5957c478bd9Sstevel@tonic-gatemsgstr "Critical" 5967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.description" 59725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 5987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.response" 59925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 6007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.impact" 60125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 6027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-4R.action" 60325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 6047c478bd9Sstevel@tonic-gate# 6057c478bd9Sstevel@tonic-gate# code: SUN4U-8001-54 6067c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath 6077c478bd9Sstevel@tonic-gate# 6087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.type" 6097c478bd9Sstevel@tonic-gatemsgstr "Fault" 6107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.severity" 6117c478bd9Sstevel@tonic-gatemsgstr "Critical" 6127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.description" 61325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 6147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.response" 61525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 6167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.impact" 61725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 6187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-54.action" 61925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 6207c478bd9Sstevel@tonic-gate# 6217c478bd9Sstevel@tonic-gate# code: SUN4U-8001-6Q 6227c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus 6237c478bd9Sstevel@tonic-gate# 6247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.type" 6257c478bd9Sstevel@tonic-gatemsgstr "Fault" 6267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.severity" 6277c478bd9Sstevel@tonic-gatemsgstr "Critical" 6287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.description" 62925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 6307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.response" 63125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 6327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.impact" 63325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 6347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-6Q.action" 63525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 6367c478bd9Sstevel@tonic-gate# 6377c478bd9Sstevel@tonic-gate# code: SUN4U-8001-7C 6387c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus 6397c478bd9Sstevel@tonic-gate# 6407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.type" 6417c478bd9Sstevel@tonic-gatemsgstr "Fault" 6427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.severity" 6437c478bd9Sstevel@tonic-gatemsgstr "Critical" 6447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.description" 64525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 6467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.response" 64725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 6487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.impact" 64925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 6507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-7C.action" 65125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 6527c478bd9Sstevel@tonic-gate# 6537c478bd9Sstevel@tonic-gate# code: SUN4U-8001-83 6547c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device 6557c478bd9Sstevel@tonic-gate# 6567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.type" 6577c478bd9Sstevel@tonic-gatemsgstr "Fault" 6587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.severity" 6597c478bd9Sstevel@tonic-gatemsgstr "Critical" 6607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.description" 66125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 6627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.response" 66325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 6647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.impact" 66525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 6667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-83.action" 66725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 6687c478bd9Sstevel@tonic-gate# 6697c478bd9Sstevel@tonic-gate# code: SUN4U-8001-9Y 6707c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device 6717c478bd9Sstevel@tonic-gate# 6727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.type" 6737c478bd9Sstevel@tonic-gatemsgstr "Fault" 6747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.severity" 6757c478bd9Sstevel@tonic-gatemsgstr "Critical" 6767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.description" 67725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 6787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.response" 67925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 6807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.impact" 68125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 6827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-9Y.action" 68325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 6847c478bd9Sstevel@tonic-gate# 6857c478bd9Sstevel@tonic-gate# code: SUN4U-8001-AD 6867c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device 6877c478bd9Sstevel@tonic-gate# 6887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.type" 6897c478bd9Sstevel@tonic-gatemsgstr "Fault" 6907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.severity" 6917c478bd9Sstevel@tonic-gatemsgstr "Critical" 6927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.description" 69325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 6947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.response" 69525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 6967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.impact" 69725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 6987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-AD.action" 69925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 7007c478bd9Sstevel@tonic-gate# 7017c478bd9Sstevel@tonic-gate# code: SUN4U-8001-CH 7027c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device 7037c478bd9Sstevel@tonic-gate# 7047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.type" 7057c478bd9Sstevel@tonic-gatemsgstr "Fault" 7067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.severity" 7077c478bd9Sstevel@tonic-gatemsgstr "Critical" 7087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.description" 70925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 7107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.response" 71125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 7127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.impact" 71325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 7147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-CH.action" 71525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 7167c478bd9Sstevel@tonic-gate# 7177c478bd9Sstevel@tonic-gate# code: SUN4U-8001-DA 7187c478bd9Sstevel@tonic-gate# keys: fault.io.hbus 7197c478bd9Sstevel@tonic-gate# 7207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.type" 7217c478bd9Sstevel@tonic-gatemsgstr "Fault" 7227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.severity" 7237c478bd9Sstevel@tonic-gatemsgstr "Critical" 7247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.description" 72525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 7267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.response" 72725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 7287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.impact" 72925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 7307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-DA.action" 73125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 7327c478bd9Sstevel@tonic-gate# 7337c478bd9Sstevel@tonic-gate# code: SUN4U-8001-EP 7347c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus 7357c478bd9Sstevel@tonic-gate# 7367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.type" 7377c478bd9Sstevel@tonic-gatemsgstr "Fault" 7387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.severity" 7397c478bd9Sstevel@tonic-gatemsgstr "Critical" 7407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.description" 74125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 7427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.response" 74325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 7447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.impact" 74525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 7467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-EP.action" 74725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 7487c478bd9Sstevel@tonic-gate# 7497c478bd9Sstevel@tonic-gate# code: SUN4U-8001-F5 7507c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus 7517c478bd9Sstevel@tonic-gate# 7527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.type" 7537c478bd9Sstevel@tonic-gatemsgstr "Fault" 7547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.severity" 7557c478bd9Sstevel@tonic-gatemsgstr "Critical" 7567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.description" 75725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 7587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.response" 75925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 7607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.impact" 76125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 7627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-F5.action" 76325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 7647c478bd9Sstevel@tonic-gate# 7657c478bd9Sstevel@tonic-gate# code: SUN4U-8001-GS 7667c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus 7677c478bd9Sstevel@tonic-gate# 7687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.type" 7697c478bd9Sstevel@tonic-gatemsgstr "Fault" 7707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.severity" 7717c478bd9Sstevel@tonic-gatemsgstr "Critical" 7727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.description" 77325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 7747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.response" 77525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 7767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.impact" 77725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 7787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-GS.action" 77925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 7807c478bd9Sstevel@tonic-gate# 7817c478bd9Sstevel@tonic-gate# code: SUN4U-8001-H2 7827c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device 7837c478bd9Sstevel@tonic-gate# 7847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.type" 7857c478bd9Sstevel@tonic-gatemsgstr "Fault" 7867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.severity" 7877c478bd9Sstevel@tonic-gatemsgstr "Critical" 7887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.description" 78925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 7907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.response" 79125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 7927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.impact" 79325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 7947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-H2.action" 79525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 7967c478bd9Sstevel@tonic-gate# 7977c478bd9Sstevel@tonic-gate# code: SUN4U-8001-JX 7987c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device 7997c478bd9Sstevel@tonic-gate# 8007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.type" 8017c478bd9Sstevel@tonic-gatemsgstr "Fault" 8027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.severity" 8037c478bd9Sstevel@tonic-gatemsgstr "Critical" 8047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.description" 80525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 8067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.response" 80725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 8087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.impact" 80925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 8107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-JX.action" 81125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 8127c478bd9Sstevel@tonic-gate# 8137c478bd9Sstevel@tonic-gate# code: SUN4U-8001-KE 8147c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device 8157c478bd9Sstevel@tonic-gate# 8167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.type" 8177c478bd9Sstevel@tonic-gatemsgstr "Fault" 8187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.severity" 8197c478bd9Sstevel@tonic-gatemsgstr "Critical" 8207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.description" 82125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 8227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.response" 82325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 8247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.impact" 82525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 8267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-KE.action" 82725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 8287c478bd9Sstevel@tonic-gate# 8297c478bd9Sstevel@tonic-gate# code: SUN4U-8001-LJ 8307c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device 8317c478bd9Sstevel@tonic-gate# 8327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.type" 8337c478bd9Sstevel@tonic-gatemsgstr "Fault" 8347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.severity" 8357c478bd9Sstevel@tonic-gatemsgstr "Critical" 8367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.description" 83725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 8387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.response" 83925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 8407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.impact" 84125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 8427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-LJ.action" 84325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 8447c478bd9Sstevel@tonic-gate# 8457c478bd9Sstevel@tonic-gate# code: SUN4U-8001-MC 8467c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus 8477c478bd9Sstevel@tonic-gate# 8487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.type" 8497c478bd9Sstevel@tonic-gatemsgstr "Fault" 8507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.severity" 8517c478bd9Sstevel@tonic-gatemsgstr "Critical" 8527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.description" 85325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 8547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.response" 85525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 8567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.impact" 85725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 8587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-MC.action" 85925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 8607c478bd9Sstevel@tonic-gate# 8617c478bd9Sstevel@tonic-gate# code: SUN4U-8001-NQ 8627c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus 8637c478bd9Sstevel@tonic-gate# 8647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.type" 8657c478bd9Sstevel@tonic-gatemsgstr "Fault" 8667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.severity" 8677c478bd9Sstevel@tonic-gatemsgstr "Critical" 8687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.description" 86925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 8707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.response" 87125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 8727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.impact" 87325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 8747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-NQ.action" 87525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 8767c478bd9Sstevel@tonic-gate# 8777c478bd9Sstevel@tonic-gate# code: SUN4U-8001-P4 8787c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus 8797c478bd9Sstevel@tonic-gate# 8807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.type" 8817c478bd9Sstevel@tonic-gatemsgstr "Fault" 8827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.severity" 8837c478bd9Sstevel@tonic-gatemsgstr "Critical" 8847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.description" 88525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 8867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.response" 88725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 8887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.impact" 88925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 8907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-P4.action" 89125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 8927c478bd9Sstevel@tonic-gate# 8937c478bd9Sstevel@tonic-gate# code: SUN4U-8001-QR 8947c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus 8957c478bd9Sstevel@tonic-gate# 8967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.type" 8977c478bd9Sstevel@tonic-gatemsgstr "Fault" 8987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.severity" 8997c478bd9Sstevel@tonic-gatemsgstr "Critical" 9007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.description" 90125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 9027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.response" 90325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 9047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.impact" 90525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 9067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-QR.action" 90725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 9087c478bd9Sstevel@tonic-gate# 9097c478bd9Sstevel@tonic-gate# code: SUN4U-8001-RH 9107c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device 9117c478bd9Sstevel@tonic-gate# 9127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.type" 9137c478bd9Sstevel@tonic-gatemsgstr "Fault" 9147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.severity" 9157c478bd9Sstevel@tonic-gatemsgstr "Critical" 9167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.description" 91725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 9187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.response" 91925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 9207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.impact" 92125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 9227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-RH.action" 92325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 9247c478bd9Sstevel@tonic-gate# 9257c478bd9Sstevel@tonic-gate# code: SUN4U-8001-SD 9267c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device 9277c478bd9Sstevel@tonic-gate# 9287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.type" 9297c478bd9Sstevel@tonic-gatemsgstr "Fault" 9307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.severity" 9317c478bd9Sstevel@tonic-gatemsgstr "Critical" 9327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.description" 93325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 9347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.response" 93525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 9367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.impact" 93725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 9387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-SD.action" 93925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 9407c478bd9Sstevel@tonic-gate# 9417c478bd9Sstevel@tonic-gate# code: SUN4U-8001-TY 9427c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device 9437c478bd9Sstevel@tonic-gate# 9447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.type" 9457c478bd9Sstevel@tonic-gatemsgstr "Fault" 9467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.severity" 9477c478bd9Sstevel@tonic-gatemsgstr "Critical" 9487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.description" 94925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 9507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.response" 95125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 9527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.impact" 95325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 9547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-TY.action" 95525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 9567c478bd9Sstevel@tonic-gate# 9577c478bd9Sstevel@tonic-gate# code: SUN4U-8001-U3 9587c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device 9597c478bd9Sstevel@tonic-gate# 9607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.type" 9617c478bd9Sstevel@tonic-gatemsgstr "Fault" 9627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.severity" 9637c478bd9Sstevel@tonic-gatemsgstr "Critical" 9647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.description" 96525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 9667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.response" 96725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 9687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.impact" 96925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 9707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-U3.action" 97125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 9727c478bd9Sstevel@tonic-gate# 9737c478bd9Sstevel@tonic-gate# code: SUN4U-8001-VS 9747c478bd9Sstevel@tonic-gate# keys: fault.io.schizo 9757c478bd9Sstevel@tonic-gate# 9767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.type" 9777c478bd9Sstevel@tonic-gatemsgstr "Fault" 9787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.severity" 9797c478bd9Sstevel@tonic-gatemsgstr "Critical" 9807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.description" 98125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 9827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.response" 98325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 9847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.impact" 98525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 9867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-VS.action" 98725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 9887c478bd9Sstevel@tonic-gate# 9897c478bd9Sstevel@tonic-gate# code: SUN4U-8001-W5 9907c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.schizo 9917c478bd9Sstevel@tonic-gate# 9927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.type" 9937c478bd9Sstevel@tonic-gatemsgstr "Fault" 9947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.severity" 9957c478bd9Sstevel@tonic-gatemsgstr "Critical" 9967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.description" 99725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 9987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.response" 99925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 10007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.impact" 100125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 10027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-W5.action" 100325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 10047c478bd9Sstevel@tonic-gate# 10057c478bd9Sstevel@tonic-gate# code: SUN4U-8001-XP 10067c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.schizo 10077c478bd9Sstevel@tonic-gate# 10087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.type" 10097c478bd9Sstevel@tonic-gatemsgstr "Fault" 10107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.severity" 10117c478bd9Sstevel@tonic-gatemsgstr "Critical" 10127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.description" 101325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 10147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.response" 101525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 10167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.impact" 101725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 10187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-XP.action" 101925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 10207c478bd9Sstevel@tonic-gate# 10217c478bd9Sstevel@tonic-gate# code: SUN4U-8001-YA 10227c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo 10237c478bd9Sstevel@tonic-gate# 10247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.type" 10257c478bd9Sstevel@tonic-gatemsgstr "Fault" 10267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.severity" 10277c478bd9Sstevel@tonic-gatemsgstr "Critical" 10287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.description" 102925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 10307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.response" 103125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 10327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.impact" 103325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 10347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8001-YA.action" 103525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 10367c478bd9Sstevel@tonic-gate# 10377c478bd9Sstevel@tonic-gate# code: SUN4U-8002-0R 10387c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.schizo 10397c478bd9Sstevel@tonic-gate# 10407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.type" 10417c478bd9Sstevel@tonic-gatemsgstr "Fault" 10427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.severity" 10437c478bd9Sstevel@tonic-gatemsgstr "Critical" 10447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.description" 104525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 10467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.response" 104725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 10487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.impact" 104925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 10507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-0R.action" 105125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 10527c478bd9Sstevel@tonic-gate# 10537c478bd9Sstevel@tonic-gate# code: SUN4U-8002-14 10547c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo 10557c478bd9Sstevel@tonic-gate# 10567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.type" 10577c478bd9Sstevel@tonic-gatemsgstr "Fault" 10587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.severity" 10597c478bd9Sstevel@tonic-gatemsgstr "Critical" 10607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.description" 106125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 10627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.response" 106325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 10647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.impact" 106525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 10667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-14.action" 106725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 10687c478bd9Sstevel@tonic-gate# 10697c478bd9Sstevel@tonic-gate# code: SUN4U-8002-2Q 10707c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo 10717c478bd9Sstevel@tonic-gate# 10727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.type" 10737c478bd9Sstevel@tonic-gatemsgstr "Fault" 10747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.severity" 10757c478bd9Sstevel@tonic-gatemsgstr "Critical" 10767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.description" 107725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 10787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.response" 107925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 10807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.impact" 108125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 10827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-2Q.action" 108325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 10847c478bd9Sstevel@tonic-gate# 10857c478bd9Sstevel@tonic-gate# code: SUN4U-8002-3C 10867c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo 10877c478bd9Sstevel@tonic-gate# 10887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.type" 10897c478bd9Sstevel@tonic-gatemsgstr "Fault" 10907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.severity" 10917c478bd9Sstevel@tonic-gatemsgstr "Critical" 10927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.description" 109325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 10947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.response" 109525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 10967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.impact" 109725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 10987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-3C.action" 109925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 11007c478bd9Sstevel@tonic-gate# 11017c478bd9Sstevel@tonic-gate# code: SUN4U-8002-4J 11027c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.schizo 11037c478bd9Sstevel@tonic-gate# 11047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.type" 11057c478bd9Sstevel@tonic-gatemsgstr "Fault" 11067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.severity" 11077c478bd9Sstevel@tonic-gatemsgstr "Critical" 11087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.description" 110925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 11107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.response" 111125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 11127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.impact" 111325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 11147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-4J.action" 111525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 11167c478bd9Sstevel@tonic-gate# 11177c478bd9Sstevel@tonic-gate# code: SUN4U-8002-5E 11187c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo 11197c478bd9Sstevel@tonic-gate# 11207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.type" 11217c478bd9Sstevel@tonic-gatemsgstr "Fault" 11227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.severity" 11237c478bd9Sstevel@tonic-gatemsgstr "Critical" 11247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.description" 112525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 11267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.response" 112725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 11287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.impact" 112925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 11307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-5E.action" 113125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 11327c478bd9Sstevel@tonic-gate# 11337c478bd9Sstevel@tonic-gate# code: SUN4U-8002-6X 11347c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo 11357c478bd9Sstevel@tonic-gate# 11367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.type" 11377c478bd9Sstevel@tonic-gatemsgstr "Fault" 11387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.severity" 11397c478bd9Sstevel@tonic-gatemsgstr "Critical" 11407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.description" 114125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 11427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.response" 114325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 11447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.impact" 114525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 11467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-6X.action" 114725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 11487c478bd9Sstevel@tonic-gate# 11497c478bd9Sstevel@tonic-gate# code: SUN4U-8002-72 11507c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo 11517c478bd9Sstevel@tonic-gate# 11527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.type" 11537c478bd9Sstevel@tonic-gatemsgstr "Fault" 11547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.severity" 11557c478bd9Sstevel@tonic-gatemsgstr "Critical" 11567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.description" 115725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 11587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.response" 115925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 11607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.impact" 116125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 11627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-72.action" 116325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 11647c478bd9Sstevel@tonic-gate# 11657c478bd9Sstevel@tonic-gate# code: SUN4U-8002-8A 11667c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.schizo 11677c478bd9Sstevel@tonic-gate# 11687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.type" 11697c478bd9Sstevel@tonic-gatemsgstr "Fault" 11707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.severity" 11717c478bd9Sstevel@tonic-gatemsgstr "Critical" 11727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.description" 117325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 11747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.response" 117525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 11767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.impact" 117725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 11787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-8A.action" 117925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 11807c478bd9Sstevel@tonic-gate# 11817c478bd9Sstevel@tonic-gate# code: SUN4U-8002-9P 11827c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo 11837c478bd9Sstevel@tonic-gate# 11847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.type" 11857c478bd9Sstevel@tonic-gatemsgstr "Fault" 11867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.severity" 11877c478bd9Sstevel@tonic-gatemsgstr "Critical" 11887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.description" 118925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 11907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.response" 119125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 11927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.impact" 119325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 11947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-9P.action" 119525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 11967c478bd9Sstevel@tonic-gate# 11977c478bd9Sstevel@tonic-gate# code: SUN4U-8002-A5 11987c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo 11997c478bd9Sstevel@tonic-gate# 12007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.type" 12017c478bd9Sstevel@tonic-gatemsgstr "Fault" 12027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.severity" 12037c478bd9Sstevel@tonic-gatemsgstr "Critical" 12047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.description" 120525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 12067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.response" 120725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 12087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.impact" 120925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 12107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-A5.action" 121125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 12127c478bd9Sstevel@tonic-gate# 12137c478bd9Sstevel@tonic-gate# code: SUN4U-8002-CS 12147c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo 12157c478bd9Sstevel@tonic-gate# 12167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.type" 12177c478bd9Sstevel@tonic-gatemsgstr "Fault" 12187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.severity" 12197c478bd9Sstevel@tonic-gatemsgstr "Critical" 12207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.description" 122125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 12227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.response" 122325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 12247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.impact" 122525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 12267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-CS.action" 122725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 12287c478bd9Sstevel@tonic-gate# 12297c478bd9Sstevel@tonic-gate# code: SUN4U-8002-D3 12307c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.schizo 12317c478bd9Sstevel@tonic-gate# 12327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.type" 12337c478bd9Sstevel@tonic-gatemsgstr "Fault" 12347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.severity" 12357c478bd9Sstevel@tonic-gatemsgstr "Critical" 12367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.description" 123725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 12387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.response" 123925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 12407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.impact" 124125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 12427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-D3.action" 124325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 12447c478bd9Sstevel@tonic-gate# 12457c478bd9Sstevel@tonic-gate# code: SUN4U-8002-EY 12467c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo 12477c478bd9Sstevel@tonic-gate# 12487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.type" 12497c478bd9Sstevel@tonic-gatemsgstr "Fault" 12507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.severity" 12517c478bd9Sstevel@tonic-gatemsgstr "Critical" 12527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.description" 125325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 12547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.response" 125525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 12567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.impact" 125725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 12587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-EY.action" 125925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 12607c478bd9Sstevel@tonic-gate# 12617c478bd9Sstevel@tonic-gate# code: SUN4U-8002-FD 12627c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo 12637c478bd9Sstevel@tonic-gate# 12647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.type" 12657c478bd9Sstevel@tonic-gatemsgstr "Fault" 12667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.severity" 12677c478bd9Sstevel@tonic-gatemsgstr "Critical" 12687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.description" 126925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 12707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.response" 127125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 12727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.impact" 127325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 12747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-FD.action" 127525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 12767c478bd9Sstevel@tonic-gate# 12777c478bd9Sstevel@tonic-gate# code: SUN4U-8002-GH 12787c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo 12797c478bd9Sstevel@tonic-gate# 12807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.type" 12817c478bd9Sstevel@tonic-gatemsgstr "Fault" 12827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.severity" 12837c478bd9Sstevel@tonic-gatemsgstr "Critical" 12847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.description" 128525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 12867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.response" 128725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 12887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.impact" 128925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 12907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-GH.action" 129125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 12927c478bd9Sstevel@tonic-gate# 12937c478bd9Sstevel@tonic-gate# code: SUN4U-8002-HC 12947c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.schizo 12957c478bd9Sstevel@tonic-gate# 12967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.type" 12977c478bd9Sstevel@tonic-gatemsgstr "Fault" 12987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.severity" 12997c478bd9Sstevel@tonic-gatemsgstr "Critical" 13007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.description" 130125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 13027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.response" 130325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 13047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.impact" 130525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 13067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-HC.action" 130725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 13087c478bd9Sstevel@tonic-gate# 13097c478bd9Sstevel@tonic-gate# code: SUN4U-8002-JQ 13107c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo 13117c478bd9Sstevel@tonic-gate# 13127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.type" 13137c478bd9Sstevel@tonic-gatemsgstr "Fault" 13147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.severity" 13157c478bd9Sstevel@tonic-gatemsgstr "Critical" 13167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.description" 131725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 13187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.response" 131925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 13207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.impact" 132125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 13227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-JQ.action" 132325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 13247c478bd9Sstevel@tonic-gate# 13257c478bd9Sstevel@tonic-gate# code: SUN4U-8002-K4 13267c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo 13277c478bd9Sstevel@tonic-gate# 13287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.type" 13297c478bd9Sstevel@tonic-gatemsgstr "Fault" 13307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.severity" 13317c478bd9Sstevel@tonic-gatemsgstr "Critical" 13327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.description" 133325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 13347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.response" 133525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 13367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.impact" 133725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 13387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-K4.action" 133925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 13407c478bd9Sstevel@tonic-gate# 13417c478bd9Sstevel@tonic-gate# code: SUN4U-8002-LR 13427c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo 13437c478bd9Sstevel@tonic-gate# 13447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.type" 13457c478bd9Sstevel@tonic-gatemsgstr "Fault" 13467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.severity" 13477c478bd9Sstevel@tonic-gatemsgstr "Critical" 13487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.description" 134925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 13507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.response" 135125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 13527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.impact" 135325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 13547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-LR.action" 135525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 13567c478bd9Sstevel@tonic-gate# 13577c478bd9Sstevel@tonic-gate# code: SUN4U-8002-M2 13587c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.schizo 13597c478bd9Sstevel@tonic-gate# 13607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.type" 13617c478bd9Sstevel@tonic-gatemsgstr "Fault" 13627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.severity" 13637c478bd9Sstevel@tonic-gatemsgstr "Critical" 13647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.description" 136525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 13667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.response" 136725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 13687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.impact" 136925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 13707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-M2.action" 137125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 13727c478bd9Sstevel@tonic-gate# 13737c478bd9Sstevel@tonic-gate# code: SUN4U-8002-NX 13747c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo 13757c478bd9Sstevel@tonic-gate# 13767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.type" 13777c478bd9Sstevel@tonic-gatemsgstr "Fault" 13787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.severity" 13797c478bd9Sstevel@tonic-gatemsgstr "Critical" 13807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.description" 138125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 13827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.response" 138325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 13847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.impact" 138525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 13867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-NX.action" 138725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 13887c478bd9Sstevel@tonic-gate# 13897c478bd9Sstevel@tonic-gate# code: SUN4U-8002-PE 13907c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo 13917c478bd9Sstevel@tonic-gate# 13927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.type" 13937c478bd9Sstevel@tonic-gatemsgstr "Fault" 13947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.severity" 13957c478bd9Sstevel@tonic-gatemsgstr "Critical" 13967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.description" 139725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 13987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.response" 139925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 14007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.impact" 140125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 14027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-PE.action" 140325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 14047c478bd9Sstevel@tonic-gate# 14057c478bd9Sstevel@tonic-gate# code: SUN4U-8002-QJ 14067c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo 14077c478bd9Sstevel@tonic-gate# 14087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.type" 14097c478bd9Sstevel@tonic-gatemsgstr "Fault" 14107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.severity" 14117c478bd9Sstevel@tonic-gatemsgstr "Critical" 14127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.description" 141325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 14147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.response" 141525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 14167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.impact" 141725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 14187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-QJ.action" 141925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 14207c478bd9Sstevel@tonic-gate# 14217c478bd9Sstevel@tonic-gate# code: SUN4U-8002-RS 14227c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo 14237c478bd9Sstevel@tonic-gate# 14247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.type" 14257c478bd9Sstevel@tonic-gatemsgstr "Fault" 14267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.severity" 14277c478bd9Sstevel@tonic-gatemsgstr "Critical" 14287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.description" 142925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 14307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.response" 143125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 14327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.impact" 143325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 14347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-RS.action" 143525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 14367c478bd9Sstevel@tonic-gate# 14377c478bd9Sstevel@tonic-gate# code: SUN4U-8002-S5 14387c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo 14397c478bd9Sstevel@tonic-gate# 14407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.type" 14417c478bd9Sstevel@tonic-gatemsgstr "Fault" 14427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.severity" 14437c478bd9Sstevel@tonic-gatemsgstr "Critical" 14447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.description" 144525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 14467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.response" 144725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 14487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.impact" 144925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 14507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-S5.action" 145125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 14527c478bd9Sstevel@tonic-gate# 14537c478bd9Sstevel@tonic-gate# code: SUN4U-8002-TP 14547c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo 14557c478bd9Sstevel@tonic-gate# 14567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.type" 14577c478bd9Sstevel@tonic-gatemsgstr "Fault" 14587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.severity" 14597c478bd9Sstevel@tonic-gatemsgstr "Critical" 14607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.description" 146125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 14627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.response" 146325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 14647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.impact" 146525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 14667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-TP.action" 146725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 14687c478bd9Sstevel@tonic-gate# 14697c478bd9Sstevel@tonic-gate# code: SUN4U-8002-UA 14707c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo 14717c478bd9Sstevel@tonic-gate# 14727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.type" 14737c478bd9Sstevel@tonic-gatemsgstr "Fault" 14747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.severity" 14757c478bd9Sstevel@tonic-gatemsgstr "Critical" 14767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.description" 147725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 14787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.response" 147925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 14807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.impact" 148125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 14827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-UA.action" 148325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 14847c478bd9Sstevel@tonic-gate# 14857c478bd9Sstevel@tonic-gate# code: SUN4U-8002-VH 14867c478bd9Sstevel@tonic-gate# keys: fault.io.xmits 14877c478bd9Sstevel@tonic-gate# 14887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.type" 14897c478bd9Sstevel@tonic-gatemsgstr "Fault" 14907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.severity" 14917c478bd9Sstevel@tonic-gatemsgstr "Critical" 14927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.description" 149325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 14947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.response" 149525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 14967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.impact" 149725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 14987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-VH.action" 149925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 15007c478bd9Sstevel@tonic-gate# 15017c478bd9Sstevel@tonic-gate# code: SUN4U-8002-WD 15027c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.xmits 15037c478bd9Sstevel@tonic-gate# 15047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.type" 15057c478bd9Sstevel@tonic-gatemsgstr "Fault" 15067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.severity" 15077c478bd9Sstevel@tonic-gatemsgstr "Critical" 15087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.description" 150925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 15107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.response" 151125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 15127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.impact" 151325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 15147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-WD.action" 151525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 15167c478bd9Sstevel@tonic-gate# 15177c478bd9Sstevel@tonic-gate# code: SUN4U-8002-XY 15187c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.xmits 15197c478bd9Sstevel@tonic-gate# 15207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.type" 15217c478bd9Sstevel@tonic-gatemsgstr "Fault" 15227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.severity" 15237c478bd9Sstevel@tonic-gatemsgstr "Critical" 15247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.description" 152525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 15267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.response" 152725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 15287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.impact" 152925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 15307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-XY.action" 153125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 15327c478bd9Sstevel@tonic-gate# 15337c478bd9Sstevel@tonic-gate# code: SUN4U-8002-Y3 15347c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits 15357c478bd9Sstevel@tonic-gate# 15367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.type" 15377c478bd9Sstevel@tonic-gatemsgstr "Fault" 15387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.severity" 15397c478bd9Sstevel@tonic-gatemsgstr "Critical" 15407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.description" 154125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 15427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.response" 154325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 15447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.impact" 154525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 15467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8002-Y3.action" 154725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 15487c478bd9Sstevel@tonic-gate# 15497c478bd9Sstevel@tonic-gate# code: SUN4U-8003-0Y 15507c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.xmits 15517c478bd9Sstevel@tonic-gate# 15527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.type" 15537c478bd9Sstevel@tonic-gatemsgstr "Fault" 15547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.severity" 15557c478bd9Sstevel@tonic-gatemsgstr "Critical" 15567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.description" 155725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 15587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.response" 155925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 15607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.impact" 156125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 15627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-0Y.action" 156325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 15647c478bd9Sstevel@tonic-gate# 15657c478bd9Sstevel@tonic-gate# code: SUN4U-8003-13 15667c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits 15677c478bd9Sstevel@tonic-gate# 15687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.type" 15697c478bd9Sstevel@tonic-gatemsgstr "Fault" 15707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.severity" 15717c478bd9Sstevel@tonic-gatemsgstr "Critical" 15727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.description" 157325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 15747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.response" 157525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 15767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.impact" 157725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 15787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-13.action" 157925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 15807c478bd9Sstevel@tonic-gate# 15817c478bd9Sstevel@tonic-gate# code: SUN4U-8003-2H 15827c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits 15837c478bd9Sstevel@tonic-gate# 15847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.type" 15857c478bd9Sstevel@tonic-gatemsgstr "Fault" 15867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.severity" 15877c478bd9Sstevel@tonic-gatemsgstr "Critical" 15887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.description" 158925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 15907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.response" 159125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 15927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.impact" 159325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 15947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-2H.action" 159525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 15967c478bd9Sstevel@tonic-gate# 15977c478bd9Sstevel@tonic-gate# code: SUN4U-8003-3D 15987c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits 15997c478bd9Sstevel@tonic-gate# 16007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.type" 16017c478bd9Sstevel@tonic-gatemsgstr "Fault" 16027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.severity" 16037c478bd9Sstevel@tonic-gatemsgstr "Critical" 16047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.description" 160525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 16067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.response" 160725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 16087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.impact" 160925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 16107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-3D.action" 161125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 16127c478bd9Sstevel@tonic-gate# 16137c478bd9Sstevel@tonic-gate# code: SUN4U-8003-4P 16147c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.xmits 16157c478bd9Sstevel@tonic-gate# 16167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.type" 16177c478bd9Sstevel@tonic-gatemsgstr "Fault" 16187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.severity" 16197c478bd9Sstevel@tonic-gatemsgstr "Critical" 16207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.description" 162125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 16227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.response" 162325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 16247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.impact" 162525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 16267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-4P.action" 162725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 16287c478bd9Sstevel@tonic-gate# 16297c478bd9Sstevel@tonic-gate# code: SUN4U-8003-5A 16307c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.xmits 16317c478bd9Sstevel@tonic-gate# 16327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.type" 16337c478bd9Sstevel@tonic-gatemsgstr "Fault" 16347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.severity" 16357c478bd9Sstevel@tonic-gatemsgstr "Critical" 16367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.description" 163725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 16387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.response" 163925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 16407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.impact" 164125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 16427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-5A.action" 164325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 16447c478bd9Sstevel@tonic-gate# 16457c478bd9Sstevel@tonic-gate# code: SUN4U-8003-6S 16467c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.xmits 16477c478bd9Sstevel@tonic-gate# 16487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.type" 16497c478bd9Sstevel@tonic-gatemsgstr "Fault" 16507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.severity" 16517c478bd9Sstevel@tonic-gatemsgstr "Critical" 16527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.description" 165325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 16547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.response" 165525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 16567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.impact" 165725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 16587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-6S.action" 165925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 16607c478bd9Sstevel@tonic-gate# 16617c478bd9Sstevel@tonic-gate# code: SUN4U-8003-75 16627c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits 16637c478bd9Sstevel@tonic-gate# 16647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.type" 16657c478bd9Sstevel@tonic-gatemsgstr "Fault" 16667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.severity" 16677c478bd9Sstevel@tonic-gatemsgstr "Critical" 16687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.description" 166925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 16707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.response" 167125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 16727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.impact" 167325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 16747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-75.action" 167525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 16767c478bd9Sstevel@tonic-gate# 16777c478bd9Sstevel@tonic-gate# code: SUN4U-8003-8E 16787c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.xmits 16797c478bd9Sstevel@tonic-gate# 16807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.type" 16817c478bd9Sstevel@tonic-gatemsgstr "Fault" 16827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.severity" 16837c478bd9Sstevel@tonic-gatemsgstr "Critical" 16847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.description" 168525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 16867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.response" 168725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 16887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.impact" 168925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 16907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-8E.action" 169125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 16927c478bd9Sstevel@tonic-gate# 16937c478bd9Sstevel@tonic-gate# code: SUN4U-8003-9J 16947c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits 16957c478bd9Sstevel@tonic-gate# 16967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.type" 16977c478bd9Sstevel@tonic-gatemsgstr "Fault" 16987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.severity" 16997c478bd9Sstevel@tonic-gatemsgstr "Critical" 17007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.description" 170125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 17027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.response" 170325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 17047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.impact" 170525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 17067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-9J.action" 170725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 17087c478bd9Sstevel@tonic-gate# 17097c478bd9Sstevel@tonic-gate# code: SUN4U-8003-A2 17107c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits 17117c478bd9Sstevel@tonic-gate# 17127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.type" 17137c478bd9Sstevel@tonic-gatemsgstr "Fault" 17147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.severity" 17157c478bd9Sstevel@tonic-gatemsgstr "Critical" 17167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.description" 171725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 17187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.response" 171925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 17207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.impact" 172125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 17227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-A2.action" 172325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 17247c478bd9Sstevel@tonic-gate# 17257c478bd9Sstevel@tonic-gate# code: SUN4U-8003-CX 17267c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits 17277c478bd9Sstevel@tonic-gate# 17287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.type" 17297c478bd9Sstevel@tonic-gatemsgstr "Fault" 17307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.severity" 17317c478bd9Sstevel@tonic-gatemsgstr "Critical" 17327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.description" 173325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 17347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.response" 173525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 17367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.impact" 173725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 17387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-CX.action" 173925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 17407c478bd9Sstevel@tonic-gate# 17417c478bd9Sstevel@tonic-gate# code: SUN4U-8003-D4 17427c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.xmits 17437c478bd9Sstevel@tonic-gate# 17447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.type" 17457c478bd9Sstevel@tonic-gatemsgstr "Fault" 17467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.severity" 17477c478bd9Sstevel@tonic-gatemsgstr "Critical" 17487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.description" 174925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 17507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.response" 175125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 17527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.impact" 175325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 17547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-D4.action" 175525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 17567c478bd9Sstevel@tonic-gate# 17577c478bd9Sstevel@tonic-gate# code: SUN4U-8003-ER 17587c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.xmits 17597c478bd9Sstevel@tonic-gate# 17607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.type" 17617c478bd9Sstevel@tonic-gatemsgstr "Fault" 17627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.severity" 17637c478bd9Sstevel@tonic-gatemsgstr "Critical" 17647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.description" 176525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 17667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.response" 176725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 17687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.impact" 176925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 17707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-ER.action" 177125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 17727c478bd9Sstevel@tonic-gate# 17737c478bd9Sstevel@tonic-gate# code: SUN4U-8003-FC 17747c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.xmits 17757c478bd9Sstevel@tonic-gate# 17767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.type" 17777c478bd9Sstevel@tonic-gatemsgstr "Fault" 17787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.severity" 17797c478bd9Sstevel@tonic-gatemsgstr "Critical" 17807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.description" 178125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 17827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.response" 178325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 17847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.impact" 178525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 17867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-FC.action" 178725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 17887c478bd9Sstevel@tonic-gate# 17897c478bd9Sstevel@tonic-gate# code: SUN4U-8003-GQ 17907c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits 17917c478bd9Sstevel@tonic-gate# 17927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.type" 17937c478bd9Sstevel@tonic-gatemsgstr "Fault" 17947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.severity" 17957c478bd9Sstevel@tonic-gatemsgstr "Critical" 17967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.description" 179725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 17987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.response" 179925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 18007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.impact" 180125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 18027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-GQ.action" 180325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 18047c478bd9Sstevel@tonic-gate# 18057c478bd9Sstevel@tonic-gate# code: SUN4U-8003-HD 18067c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.xmits 18077c478bd9Sstevel@tonic-gate# 18087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.type" 18097c478bd9Sstevel@tonic-gatemsgstr "Fault" 18107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.severity" 18117c478bd9Sstevel@tonic-gatemsgstr "Critical" 18127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.description" 181325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 18147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.response" 181525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 18167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.impact" 181725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 18187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-HD.action" 181925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 18207c478bd9Sstevel@tonic-gate# 18217c478bd9Sstevel@tonic-gate# code: SUN4U-8003-JH 18227c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits 18237c478bd9Sstevel@tonic-gate# 18247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.type" 18257c478bd9Sstevel@tonic-gatemsgstr "Fault" 18267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.severity" 18277c478bd9Sstevel@tonic-gatemsgstr "Critical" 18287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.description" 182925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 18307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.response" 183125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 18327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.impact" 183325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 18347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-JH.action" 183525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 18367c478bd9Sstevel@tonic-gate# 18377c478bd9Sstevel@tonic-gate# code: SUN4U-8003-K3 18387c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits 18397c478bd9Sstevel@tonic-gate# 18407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.type" 18417c478bd9Sstevel@tonic-gatemsgstr "Fault" 18427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.severity" 18437c478bd9Sstevel@tonic-gatemsgstr "Critical" 18447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.description" 184525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 18467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.response" 184725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 18487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.impact" 184925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 18507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-K3.action" 185125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 18527c478bd9Sstevel@tonic-gate# 18537c478bd9Sstevel@tonic-gate# code: SUN4U-8003-LY 18547c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits 18557c478bd9Sstevel@tonic-gate# 18567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.type" 18577c478bd9Sstevel@tonic-gatemsgstr "Fault" 18587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.severity" 18597c478bd9Sstevel@tonic-gatemsgstr "Critical" 18607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.description" 186125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 18627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.response" 186325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 18647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.impact" 186525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 18667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-LY.action" 186725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 18687c478bd9Sstevel@tonic-gate# 18697c478bd9Sstevel@tonic-gate# code: SUN4U-8003-M5 18707c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.xmits 18717c478bd9Sstevel@tonic-gate# 18727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.type" 18737c478bd9Sstevel@tonic-gatemsgstr "Fault" 18747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.severity" 18757c478bd9Sstevel@tonic-gatemsgstr "Critical" 18767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.description" 187725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 18787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.response" 187925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 18807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.impact" 188125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 18827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-M5.action" 188325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 18847c478bd9Sstevel@tonic-gate# 18857c478bd9Sstevel@tonic-gate# code: SUN4U-8003-NS 18867c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits 18877c478bd9Sstevel@tonic-gate# 18887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.type" 18897c478bd9Sstevel@tonic-gatemsgstr "Fault" 18907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.severity" 18917c478bd9Sstevel@tonic-gatemsgstr "Critical" 18927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.description" 189325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 18947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.response" 189525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 18967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.impact" 189725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 18987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-NS.action" 189925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 19007c478bd9Sstevel@tonic-gate# 19017c478bd9Sstevel@tonic-gate# code: SUN4U-8003-PA 19027c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits 19037c478bd9Sstevel@tonic-gate# 19047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.type" 19057c478bd9Sstevel@tonic-gatemsgstr "Fault" 19067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.severity" 19077c478bd9Sstevel@tonic-gatemsgstr "Critical" 19087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.description" 190925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 19107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.response" 191125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 19127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.impact" 191325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 19147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-PA.action" 191525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 19167c478bd9Sstevel@tonic-gate# 19177c478bd9Sstevel@tonic-gate# code: SUN4U-8003-QP 19187c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits 19197c478bd9Sstevel@tonic-gate# 19207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.type" 19217c478bd9Sstevel@tonic-gatemsgstr "Fault" 19227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.severity" 19237c478bd9Sstevel@tonic-gatemsgstr "Critical" 19247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.description" 192525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 19267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.response" 192725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 19287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.impact" 192925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 19307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-QP.action" 193125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 19327c478bd9Sstevel@tonic-gate# 19337c478bd9Sstevel@tonic-gate# code: SUN4U-8003-RX 19347c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits 19357c478bd9Sstevel@tonic-gate# 19367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.type" 19377c478bd9Sstevel@tonic-gatemsgstr "Fault" 19387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.severity" 19397c478bd9Sstevel@tonic-gatemsgstr "Critical" 19407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.description" 194125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 19427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.response" 194325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 19447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.impact" 194525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 19467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-RX.action" 194725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 19487c478bd9Sstevel@tonic-gate# 19497c478bd9Sstevel@tonic-gate# code: SUN4U-8003-S2 19507c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits 19517c478bd9Sstevel@tonic-gate# 19527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.type" 19537c478bd9Sstevel@tonic-gatemsgstr "Fault" 19547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.severity" 19557c478bd9Sstevel@tonic-gatemsgstr "Critical" 19567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.description" 195725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 19587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.response" 195925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 19607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.impact" 196125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 19627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-S2.action" 196325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 19647c478bd9Sstevel@tonic-gate# 19657c478bd9Sstevel@tonic-gate# code: SUN4U-8003-TJ 19667c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits 19677c478bd9Sstevel@tonic-gate# 19687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.type" 19697c478bd9Sstevel@tonic-gatemsgstr "Fault" 19707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.severity" 19717c478bd9Sstevel@tonic-gatemsgstr "Critical" 19727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.description" 197325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 19747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.response" 197525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 19767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.impact" 197725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 19787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-TJ.action" 197925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 19807c478bd9Sstevel@tonic-gate# 19817c478bd9Sstevel@tonic-gate# code: SUN4U-8003-UE 19827c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits 19837c478bd9Sstevel@tonic-gate# 19847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.type" 19857c478bd9Sstevel@tonic-gatemsgstr "Fault" 19867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.severity" 19877c478bd9Sstevel@tonic-gatemsgstr "Critical" 19887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.description" 198925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 19907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.response" 199125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 19927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.impact" 199325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 19947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-UE.action" 199525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 19967c478bd9Sstevel@tonic-gate# 19977c478bd9Sstevel@tonic-gate# code: SUN4U-8003-VQ 19987c478bd9Sstevel@tonic-gate# keys: fault.io.schizo fault.io.xmits 19997c478bd9Sstevel@tonic-gate# 20007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.type" 20017c478bd9Sstevel@tonic-gatemsgstr "Fault" 20027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.severity" 20037c478bd9Sstevel@tonic-gatemsgstr "Critical" 20047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.description" 200525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 20067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.response" 200725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 20087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.impact" 200925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 20107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-VQ.action" 201125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 20127c478bd9Sstevel@tonic-gate# 20137c478bd9Sstevel@tonic-gate# code: SUN4U-8003-WC 20147c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.schizo fault.io.xmits 20157c478bd9Sstevel@tonic-gate# 20167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.type" 20177c478bd9Sstevel@tonic-gatemsgstr "Fault" 20187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.severity" 20197c478bd9Sstevel@tonic-gatemsgstr "Critical" 20207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.description" 202125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 20227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.response" 202325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 20247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.impact" 202525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 20267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-WC.action" 202725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 20287c478bd9Sstevel@tonic-gate# 20297c478bd9Sstevel@tonic-gate# code: SUN4U-8003-XR 20307c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.schizo fault.io.xmits 20317c478bd9Sstevel@tonic-gate# 20327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.type" 20337c478bd9Sstevel@tonic-gatemsgstr "Fault" 20347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.severity" 20357c478bd9Sstevel@tonic-gatemsgstr "Critical" 20367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.description" 203725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 20387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.response" 203925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 20407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.impact" 204125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 20427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-XR.action" 204325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 20447c478bd9Sstevel@tonic-gate# 20457c478bd9Sstevel@tonic-gate# code: SUN4U-8003-Y4 20467c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits 20477c478bd9Sstevel@tonic-gate# 20487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.type" 20497c478bd9Sstevel@tonic-gatemsgstr "Fault" 20507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.severity" 20517c478bd9Sstevel@tonic-gatemsgstr "Critical" 20527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.description" 205325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 20547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.response" 205525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 20567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.impact" 205725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 20587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8003-Y4.action" 205925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 20607c478bd9Sstevel@tonic-gate# 20617c478bd9Sstevel@tonic-gate# code: SUN4U-8004-0A 20627c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.schizo fault.io.xmits 20637c478bd9Sstevel@tonic-gate# 20647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.type" 20657c478bd9Sstevel@tonic-gatemsgstr "Fault" 20667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.severity" 20677c478bd9Sstevel@tonic-gatemsgstr "Critical" 20687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.description" 206925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 20707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.response" 207125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 20727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.impact" 207325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 20747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-0A.action" 207525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 20767c478bd9Sstevel@tonic-gate# 20777c478bd9Sstevel@tonic-gate# code: SUN4U-8004-1P 20787c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits 20797c478bd9Sstevel@tonic-gate# 20807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.type" 20817c478bd9Sstevel@tonic-gatemsgstr "Fault" 20827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.severity" 20837c478bd9Sstevel@tonic-gatemsgstr "Critical" 20847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.description" 208525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 20867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.response" 208725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 20887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.impact" 208925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 20907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-1P.action" 209125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 20927c478bd9Sstevel@tonic-gate# 20937c478bd9Sstevel@tonic-gate# code: SUN4U-8004-25 20947c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 20957c478bd9Sstevel@tonic-gate# 20967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.type" 20977c478bd9Sstevel@tonic-gatemsgstr "Fault" 20987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.severity" 20997c478bd9Sstevel@tonic-gatemsgstr "Critical" 21007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.description" 210125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 21027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.response" 210325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 21047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.impact" 210525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 21067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-25.action" 210725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 21087c478bd9Sstevel@tonic-gate# 21097c478bd9Sstevel@tonic-gate# code: SUN4U-8004-3S 21107c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 21117c478bd9Sstevel@tonic-gate# 21127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.type" 21137c478bd9Sstevel@tonic-gatemsgstr "Fault" 21147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.severity" 21157c478bd9Sstevel@tonic-gatemsgstr "Critical" 21167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.description" 211725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 21187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.response" 211925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 21207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.impact" 212125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 21227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-3S.action" 212325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 21247c478bd9Sstevel@tonic-gate# 21257c478bd9Sstevel@tonic-gate# code: SUN4U-8004-43 21267c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.schizo fault.io.xmits 21277c478bd9Sstevel@tonic-gate# 21287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.type" 21297c478bd9Sstevel@tonic-gatemsgstr "Fault" 21307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.severity" 21317c478bd9Sstevel@tonic-gatemsgstr "Critical" 21327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.description" 213325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 21347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.response" 213525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 21367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.impact" 213725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 21387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-43.action" 213925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 21407c478bd9Sstevel@tonic-gate# 21417c478bd9Sstevel@tonic-gate# code: SUN4U-8004-5Y 21427c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits 21437c478bd9Sstevel@tonic-gate# 21447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.type" 21457c478bd9Sstevel@tonic-gatemsgstr "Fault" 21467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.severity" 21477c478bd9Sstevel@tonic-gatemsgstr "Critical" 21487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.description" 214925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 21507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.response" 215125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 21527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.impact" 215325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 21547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-5Y.action" 215525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 21567c478bd9Sstevel@tonic-gate# 21577c478bd9Sstevel@tonic-gate# code: SUN4U-8004-6D 21587c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits 21597c478bd9Sstevel@tonic-gate# 21607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.type" 21617c478bd9Sstevel@tonic-gatemsgstr "Fault" 21627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.severity" 21637c478bd9Sstevel@tonic-gatemsgstr "Critical" 21647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.description" 216525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 21667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.response" 216725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 21687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.impact" 216925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 21707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-6D.action" 217125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 21727c478bd9Sstevel@tonic-gate# 21737c478bd9Sstevel@tonic-gate# code: SUN4U-8004-7H 21747c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits 21757c478bd9Sstevel@tonic-gate# 21767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.type" 21777c478bd9Sstevel@tonic-gatemsgstr "Fault" 21787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.severity" 21797c478bd9Sstevel@tonic-gatemsgstr "Critical" 21807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.description" 218125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 21827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.response" 218325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 21847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.impact" 218525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 21867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-7H.action" 218725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 21887c478bd9Sstevel@tonic-gate# 21897c478bd9Sstevel@tonic-gate# code: SUN4U-8004-8R 21907c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits 21917c478bd9Sstevel@tonic-gate# 21927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.type" 21937c478bd9Sstevel@tonic-gatemsgstr "Fault" 21947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.severity" 21957c478bd9Sstevel@tonic-gatemsgstr "Critical" 21967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.description" 219725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 21987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.response" 219925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 22007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.impact" 220125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 22027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-8R.action" 220325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 22047c478bd9Sstevel@tonic-gate# 22057c478bd9Sstevel@tonic-gate# code: SUN4U-8004-94 22067c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits 22077c478bd9Sstevel@tonic-gate# 22087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.type" 22097c478bd9Sstevel@tonic-gatemsgstr "Fault" 22107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.severity" 22117c478bd9Sstevel@tonic-gatemsgstr "Critical" 22127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.description" 221325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 22147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.response" 221525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 22167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.impact" 221725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 22187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-94.action" 221925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 22207c478bd9Sstevel@tonic-gate# 22217c478bd9Sstevel@tonic-gate# code: SUN4U-8004-AQ 22227c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 22237c478bd9Sstevel@tonic-gate# 22247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.type" 22257c478bd9Sstevel@tonic-gatemsgstr "Fault" 22267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.severity" 22277c478bd9Sstevel@tonic-gatemsgstr "Critical" 22287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.description" 222925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 22307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.response" 223125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 22327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.impact" 223325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 22347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-AQ.action" 223525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 22367c478bd9Sstevel@tonic-gate# 22377c478bd9Sstevel@tonic-gate# code: SUN4U-8004-CC 22387c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 22397c478bd9Sstevel@tonic-gate# 22407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.type" 22417c478bd9Sstevel@tonic-gatemsgstr "Fault" 22427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.severity" 22437c478bd9Sstevel@tonic-gatemsgstr "Critical" 22447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.description" 224525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 22467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.response" 224725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 22487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.impact" 224925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 22507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-CC.action" 225125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 22527c478bd9Sstevel@tonic-gate# 22537c478bd9Sstevel@tonic-gate# code: SUN4U-8004-DJ 22547c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.schizo fault.io.xmits 22557c478bd9Sstevel@tonic-gate# 22567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.type" 22577c478bd9Sstevel@tonic-gatemsgstr "Fault" 22587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.severity" 22597c478bd9Sstevel@tonic-gatemsgstr "Critical" 22607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.description" 226125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 22627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.response" 226325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 22647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.impact" 226525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 22667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-DJ.action" 226725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 22687c478bd9Sstevel@tonic-gate# 22697c478bd9Sstevel@tonic-gate# code: SUN4U-8004-EE 22707c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits 22717c478bd9Sstevel@tonic-gate# 22727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.type" 22737c478bd9Sstevel@tonic-gatemsgstr "Fault" 22747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.severity" 22757c478bd9Sstevel@tonic-gatemsgstr "Critical" 22767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.description" 227725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 22787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.response" 227925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 22807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.impact" 228125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 22827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-EE.action" 228325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 22847c478bd9Sstevel@tonic-gate# 22857c478bd9Sstevel@tonic-gate# code: SUN4U-8004-FX 22867c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits 22877c478bd9Sstevel@tonic-gate# 22887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.type" 22897c478bd9Sstevel@tonic-gatemsgstr "Fault" 22907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.severity" 22917c478bd9Sstevel@tonic-gatemsgstr "Critical" 22927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.description" 229325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 22947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.response" 229525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 22967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.impact" 229725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 22987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-FX.action" 229925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 23007c478bd9Sstevel@tonic-gate# 23017c478bd9Sstevel@tonic-gate# code: SUN4U-8004-G2 23027c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits 23037c478bd9Sstevel@tonic-gate# 23047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.type" 23057c478bd9Sstevel@tonic-gatemsgstr "Fault" 23067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.severity" 23077c478bd9Sstevel@tonic-gatemsgstr "Critical" 23087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.description" 230925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 23107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.response" 231125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 23127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.impact" 231325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 23147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-G2.action" 231525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 23167c478bd9Sstevel@tonic-gate# 23177c478bd9Sstevel@tonic-gate# code: SUN4U-8004-HS 23187c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits 23197c478bd9Sstevel@tonic-gate# 23207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.type" 23217c478bd9Sstevel@tonic-gatemsgstr "Fault" 23227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.severity" 23237c478bd9Sstevel@tonic-gatemsgstr "Critical" 23247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.description" 232525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 23267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.response" 232725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 23287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.impact" 232925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 23307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-HS.action" 233125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 23327c478bd9Sstevel@tonic-gate# 23337c478bd9Sstevel@tonic-gate# code: SUN4U-8004-J5 23347c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits 23357c478bd9Sstevel@tonic-gate# 23367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.type" 23377c478bd9Sstevel@tonic-gatemsgstr "Fault" 23387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.severity" 23397c478bd9Sstevel@tonic-gatemsgstr "Critical" 23407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.description" 234125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 23427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.response" 234325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 23447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.impact" 234525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 23467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-J5.action" 234725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 23487c478bd9Sstevel@tonic-gate# 23497c478bd9Sstevel@tonic-gate# code: SUN4U-8004-KP 23507c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 23517c478bd9Sstevel@tonic-gate# 23527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.type" 23537c478bd9Sstevel@tonic-gatemsgstr "Fault" 23547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.severity" 23557c478bd9Sstevel@tonic-gatemsgstr "Critical" 23567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.description" 235725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 23587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.response" 235925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 23607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.impact" 236125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 23627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-KP.action" 236325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 23647c478bd9Sstevel@tonic-gate# 23657c478bd9Sstevel@tonic-gate# code: SUN4U-8004-LA 23667c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 23677c478bd9Sstevel@tonic-gate# 23687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.type" 23697c478bd9Sstevel@tonic-gatemsgstr "Fault" 23707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.severity" 23717c478bd9Sstevel@tonic-gatemsgstr "Critical" 23727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.description" 237325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 23747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.response" 237525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 23767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.impact" 237725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 23787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-LA.action" 237925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 23807c478bd9Sstevel@tonic-gate# 23817c478bd9Sstevel@tonic-gate# code: SUN4U-8004-MH 23827c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits 23837c478bd9Sstevel@tonic-gate# 23847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.type" 23857c478bd9Sstevel@tonic-gatemsgstr "Fault" 23867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.severity" 23877c478bd9Sstevel@tonic-gatemsgstr "Critical" 23887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.description" 238925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 23907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.response" 239125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 23927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.impact" 239325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 23947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-MH.action" 239525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 23967c478bd9Sstevel@tonic-gate# 23977c478bd9Sstevel@tonic-gate# code: SUN4U-8004-ND 23987c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits 23997c478bd9Sstevel@tonic-gate# 24007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.type" 24017c478bd9Sstevel@tonic-gatemsgstr "Fault" 24027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.severity" 24037c478bd9Sstevel@tonic-gatemsgstr "Critical" 24047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.description" 240525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 24067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.response" 240725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 24087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.impact" 240925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 24107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-ND.action" 241125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 24127c478bd9Sstevel@tonic-gate# 24137c478bd9Sstevel@tonic-gate# code: SUN4U-8004-PY 24147c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits 24157c478bd9Sstevel@tonic-gate# 24167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.type" 24177c478bd9Sstevel@tonic-gatemsgstr "Fault" 24187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.severity" 24197c478bd9Sstevel@tonic-gatemsgstr "Critical" 24207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.description" 242125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 24227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.response" 242325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 24247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.impact" 242525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 24267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-PY.action" 242725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 24287c478bd9Sstevel@tonic-gate# 24297c478bd9Sstevel@tonic-gate# code: SUN4U-8004-Q3 24307c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits 24317c478bd9Sstevel@tonic-gate# 24327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.type" 24337c478bd9Sstevel@tonic-gatemsgstr "Fault" 24347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.severity" 24357c478bd9Sstevel@tonic-gatemsgstr "Critical" 24367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.description" 243725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 24387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.response" 243925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 24407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.impact" 244125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 24427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-Q3.action" 244325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 24447c478bd9Sstevel@tonic-gate# 24457c478bd9Sstevel@tonic-gate# code: SUN4U-8004-RC 24467c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits 24477c478bd9Sstevel@tonic-gate# 24487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.type" 24497c478bd9Sstevel@tonic-gatemsgstr "Fault" 24507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.severity" 24517c478bd9Sstevel@tonic-gatemsgstr "Critical" 24527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.description" 245325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 24547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.response" 245525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 24567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.impact" 245725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 24587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-RC.action" 245925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 24607c478bd9Sstevel@tonic-gate# 24617c478bd9Sstevel@tonic-gate# code: SUN4U-8004-SQ 24627c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits 24637c478bd9Sstevel@tonic-gate# 24647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.type" 24657c478bd9Sstevel@tonic-gatemsgstr "Fault" 24667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.severity" 24677c478bd9Sstevel@tonic-gatemsgstr "Critical" 24687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.description" 246925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 24707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.response" 247125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 24727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.impact" 247325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 24747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-SQ.action" 247525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 24767c478bd9Sstevel@tonic-gate# 24777c478bd9Sstevel@tonic-gate# code: SUN4U-8004-T4 24787c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 24797c478bd9Sstevel@tonic-gate# 24807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.type" 24817c478bd9Sstevel@tonic-gatemsgstr "Fault" 24827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.severity" 24837c478bd9Sstevel@tonic-gatemsgstr "Critical" 24847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.description" 248525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 24867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.response" 248725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 24887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.impact" 248925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 24907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-T4.action" 249125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 24927c478bd9Sstevel@tonic-gate# 24937c478bd9Sstevel@tonic-gate# code: SUN4U-8004-UR 24947c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits 24957c478bd9Sstevel@tonic-gate# 24967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.type" 24977c478bd9Sstevel@tonic-gatemsgstr "Fault" 24987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.severity" 24997c478bd9Sstevel@tonic-gatemsgstr "Critical" 25007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.description" 250125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 25027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.response" 250325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 25047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.impact" 250525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 25067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-UR.action" 250725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 25087c478bd9Sstevel@tonic-gate# 25097c478bd9Sstevel@tonic-gate# code: SUN4U-8004-V2 25107c478bd9Sstevel@tonic-gate# keys: fault.io.psycho 25117c478bd9Sstevel@tonic-gate# 25127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.type" 25137c478bd9Sstevel@tonic-gatemsgstr "Fault" 25147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.severity" 25157c478bd9Sstevel@tonic-gatemsgstr "Critical" 25167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.description" 251725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 25187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.response" 251925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 25207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.impact" 252125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 25227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-V2.action" 252325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 25247c478bd9Sstevel@tonic-gate# 25257c478bd9Sstevel@tonic-gate# code: SUN4U-8004-WX 25267c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.psycho 25277c478bd9Sstevel@tonic-gate# 25287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.type" 25297c478bd9Sstevel@tonic-gatemsgstr "Fault" 25307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.severity" 25317c478bd9Sstevel@tonic-gatemsgstr "Critical" 25327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.description" 253325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 25347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.response" 253525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 25367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.impact" 253725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 25387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-WX.action" 253925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 25407c478bd9Sstevel@tonic-gate# 25417c478bd9Sstevel@tonic-gate# code: SUN4U-8004-XE 25427c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.psycho 25437c478bd9Sstevel@tonic-gate# 25447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.type" 25457c478bd9Sstevel@tonic-gatemsgstr "Fault" 25467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.severity" 25477c478bd9Sstevel@tonic-gatemsgstr "Critical" 25487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.description" 254925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 25507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.response" 255125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 25527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.impact" 255325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 25547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-XE.action" 255525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 25567c478bd9Sstevel@tonic-gate# 25577c478bd9Sstevel@tonic-gate# code: SUN4U-8004-YJ 25587c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.psycho 25597c478bd9Sstevel@tonic-gate# 25607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.type" 25617c478bd9Sstevel@tonic-gatemsgstr "Fault" 25627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.severity" 25637c478bd9Sstevel@tonic-gatemsgstr "Critical" 25647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.description" 256525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 25667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.response" 256725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 25687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.impact" 256925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 25707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8004-YJ.action" 257125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 25727c478bd9Sstevel@tonic-gate# 25737c478bd9Sstevel@tonic-gate# code: SUN4U-8005-0E 25747c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.psycho 25757c478bd9Sstevel@tonic-gate# 25767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.type" 25777c478bd9Sstevel@tonic-gatemsgstr "Fault" 25787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.severity" 25797c478bd9Sstevel@tonic-gatemsgstr "Critical" 25807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.description" 258125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 25827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.response" 258325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 25847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.impact" 258525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 25867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-0E.action" 258725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 25887c478bd9Sstevel@tonic-gate# 25897c478bd9Sstevel@tonic-gate# code: SUN4U-8005-1J 25907c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.psycho 25917c478bd9Sstevel@tonic-gate# 25927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.type" 25937c478bd9Sstevel@tonic-gatemsgstr "Fault" 25947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.severity" 25957c478bd9Sstevel@tonic-gatemsgstr "Critical" 25967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.description" 259725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 25987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.response" 259925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 26007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.impact" 260125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 26027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-1J.action" 260325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 26047c478bd9Sstevel@tonic-gate# 26057c478bd9Sstevel@tonic-gate# code: SUN4U-8005-22 26067c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.psycho 26077c478bd9Sstevel@tonic-gate# 26087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.type" 26097c478bd9Sstevel@tonic-gatemsgstr "Fault" 26107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.severity" 26117c478bd9Sstevel@tonic-gatemsgstr "Critical" 26127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.description" 261325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 26147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.response" 261525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 26167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.impact" 261725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 26187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-22.action" 261925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 26207c478bd9Sstevel@tonic-gate# 26217c478bd9Sstevel@tonic-gate# code: SUN4U-8005-3X 26227c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho 26237c478bd9Sstevel@tonic-gate# 26247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.type" 26257c478bd9Sstevel@tonic-gatemsgstr "Fault" 26267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.severity" 26277c478bd9Sstevel@tonic-gatemsgstr "Critical" 26287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.description" 262925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 26307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.response" 263125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 26327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.impact" 263325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 26347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-3X.action" 263525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 26367c478bd9Sstevel@tonic-gate# 26377c478bd9Sstevel@tonic-gate# code: SUN4U-8005-44 26387c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.psycho 26397c478bd9Sstevel@tonic-gate# 26407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.type" 26417c478bd9Sstevel@tonic-gatemsgstr "Fault" 26427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.severity" 26437c478bd9Sstevel@tonic-gatemsgstr "Critical" 26447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.description" 264525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 26467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.response" 264725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 26487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.impact" 264925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 26507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-44.action" 265125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 26527c478bd9Sstevel@tonic-gate# 26537c478bd9Sstevel@tonic-gate# code: SUN4U-8005-5R 26547c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho 26557c478bd9Sstevel@tonic-gate# 26567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.type" 26577c478bd9Sstevel@tonic-gatemsgstr "Fault" 26587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.severity" 26597c478bd9Sstevel@tonic-gatemsgstr "Critical" 26607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.description" 266125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 26627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.response" 266325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 26647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.impact" 266525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 26667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-5R.action" 266725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 26687c478bd9Sstevel@tonic-gate# 26697c478bd9Sstevel@tonic-gate# code: SUN4U-8005-6C 26707c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.psycho 26717c478bd9Sstevel@tonic-gate# 26727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.type" 26737c478bd9Sstevel@tonic-gatemsgstr "Fault" 26747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.severity" 26757c478bd9Sstevel@tonic-gatemsgstr "Critical" 26767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.description" 267725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 26787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.response" 267925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 26807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.impact" 268125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 26827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-6C.action" 268325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 26847c478bd9Sstevel@tonic-gate# 26857c478bd9Sstevel@tonic-gate# code: SUN4U-8005-7Q 26867c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho 26877c478bd9Sstevel@tonic-gate# 26887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.type" 26897c478bd9Sstevel@tonic-gatemsgstr "Fault" 26907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.severity" 26917c478bd9Sstevel@tonic-gatemsgstr "Critical" 26927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.description" 269325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 26947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.response" 269525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 26967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.impact" 269725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 26987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-7Q.action" 269925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 27007c478bd9Sstevel@tonic-gate# 27017c478bd9Sstevel@tonic-gate# code: SUN4U-8005-8Y 27027c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.psycho 27037c478bd9Sstevel@tonic-gate# 27047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.type" 27057c478bd9Sstevel@tonic-gatemsgstr "Fault" 27067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.severity" 27077c478bd9Sstevel@tonic-gatemsgstr "Critical" 27087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.description" 270925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 27107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.response" 271125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 27127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.impact" 271325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 27147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-8Y.action" 271525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 27167c478bd9Sstevel@tonic-gate# 27177c478bd9Sstevel@tonic-gate# code: SUN4U-8005-93 27187c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho 27197c478bd9Sstevel@tonic-gate# 27207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.type" 27217c478bd9Sstevel@tonic-gatemsgstr "Fault" 27227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.severity" 27237c478bd9Sstevel@tonic-gatemsgstr "Critical" 27247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.description" 272525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 27267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.response" 272725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 27287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.impact" 272925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 27307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-93.action" 273125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 27327c478bd9Sstevel@tonic-gate# 27337c478bd9Sstevel@tonic-gate# code: SUN4U-8005-AH 27347c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho 27357c478bd9Sstevel@tonic-gate# 27367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.type" 27377c478bd9Sstevel@tonic-gatemsgstr "Fault" 27387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.severity" 27397c478bd9Sstevel@tonic-gatemsgstr "Critical" 27407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.description" 274125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 27427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.response" 274325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 27447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.impact" 274525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 27467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-AH.action" 274725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 27487c478bd9Sstevel@tonic-gate# 27497c478bd9Sstevel@tonic-gate# code: SUN4U-8005-CD 27507c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho 27517c478bd9Sstevel@tonic-gate# 27527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.type" 27537c478bd9Sstevel@tonic-gatemsgstr "Fault" 27547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.severity" 27557c478bd9Sstevel@tonic-gatemsgstr "Critical" 27567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.description" 275725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 27587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.response" 275925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 27607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.impact" 276125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 27627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-CD.action" 276325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 27647c478bd9Sstevel@tonic-gate# 27657c478bd9Sstevel@tonic-gate# code: SUN4U-8005-DP 27667c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.psycho 27677c478bd9Sstevel@tonic-gate# 27687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.type" 27697c478bd9Sstevel@tonic-gatemsgstr "Fault" 27707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.severity" 27717c478bd9Sstevel@tonic-gatemsgstr "Critical" 27727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.description" 277325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 27747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.response" 277525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 27767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.impact" 277725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 27787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-DP.action" 277925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 27807c478bd9Sstevel@tonic-gate# 27817c478bd9Sstevel@tonic-gate# code: SUN4U-8005-EA 27827c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho 27837c478bd9Sstevel@tonic-gate# 27847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.type" 27857c478bd9Sstevel@tonic-gatemsgstr "Fault" 27867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.severity" 27877c478bd9Sstevel@tonic-gatemsgstr "Critical" 27887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.description" 278925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 27907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.response" 279125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 27927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.impact" 279325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 27947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-EA.action" 279525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 27967c478bd9Sstevel@tonic-gate# 27977c478bd9Sstevel@tonic-gate# code: SUN4U-8005-FS 27987c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.psycho 27997c478bd9Sstevel@tonic-gate# 28007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.type" 28017c478bd9Sstevel@tonic-gatemsgstr "Fault" 28027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.severity" 28037c478bd9Sstevel@tonic-gatemsgstr "Critical" 28047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.description" 280525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 28067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.response" 280725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 28087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.impact" 280925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 28107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-FS.action" 281125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 28127c478bd9Sstevel@tonic-gate# 28137c478bd9Sstevel@tonic-gate# code: SUN4U-8005-G5 28147c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho 28157c478bd9Sstevel@tonic-gate# 28167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.type" 28177c478bd9Sstevel@tonic-gatemsgstr "Fault" 28187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.severity" 28197c478bd9Sstevel@tonic-gatemsgstr "Critical" 28207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.description" 282125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 28227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.response" 282325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 28247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.impact" 282525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 28267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-G5.action" 282725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 28287c478bd9Sstevel@tonic-gate# 28297c478bd9Sstevel@tonic-gate# code: SUN4U-8005-HX 28307c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.psycho 28317c478bd9Sstevel@tonic-gate# 28327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.type" 28337c478bd9Sstevel@tonic-gatemsgstr "Fault" 28347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.severity" 28357c478bd9Sstevel@tonic-gatemsgstr "Critical" 28367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.description" 283725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 28387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.response" 283925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 28407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.impact" 284125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 28427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-HX.action" 284325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 28447c478bd9Sstevel@tonic-gate# 28457c478bd9Sstevel@tonic-gate# code: SUN4U-8005-J2 28467c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho 28477c478bd9Sstevel@tonic-gate# 28487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.type" 28497c478bd9Sstevel@tonic-gatemsgstr "Fault" 28507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.severity" 28517c478bd9Sstevel@tonic-gatemsgstr "Critical" 28527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.description" 285325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 28547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.response" 285525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 28567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.impact" 285725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 28587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-J2.action" 285925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 28607c478bd9Sstevel@tonic-gate# 28617c478bd9Sstevel@tonic-gate# code: SUN4U-8005-KJ 28627c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho 28637c478bd9Sstevel@tonic-gate# 28647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.type" 28657c478bd9Sstevel@tonic-gatemsgstr "Fault" 28667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.severity" 28677c478bd9Sstevel@tonic-gatemsgstr "Critical" 28687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.description" 286925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 28707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.response" 287125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 28727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.impact" 287325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 28747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-KJ.action" 287525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 28767c478bd9Sstevel@tonic-gate# 28777c478bd9Sstevel@tonic-gate# code: SUN4U-8005-LE 28787c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho 28797c478bd9Sstevel@tonic-gate# 28807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.type" 28817c478bd9Sstevel@tonic-gatemsgstr "Fault" 28827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.severity" 28837c478bd9Sstevel@tonic-gatemsgstr "Critical" 28847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.description" 288525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 28867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.response" 288725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 28887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.impact" 288925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 28907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-LE.action" 289125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 28927c478bd9Sstevel@tonic-gate# 28937c478bd9Sstevel@tonic-gate# code: SUN4U-8005-MQ 28947c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho 28957c478bd9Sstevel@tonic-gate# 28967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.type" 28977c478bd9Sstevel@tonic-gatemsgstr "Fault" 28987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.severity" 28997c478bd9Sstevel@tonic-gatemsgstr "Critical" 29007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.description" 290125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 29027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.response" 290325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 29047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.impact" 290525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 29067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-MQ.action" 290725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 29087c478bd9Sstevel@tonic-gate# 29097c478bd9Sstevel@tonic-gate# code: SUN4U-8005-NC 29107c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho 29117c478bd9Sstevel@tonic-gate# 29127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.type" 29137c478bd9Sstevel@tonic-gatemsgstr "Fault" 29147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.severity" 29157c478bd9Sstevel@tonic-gatemsgstr "Critical" 29167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.description" 291725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 29187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.response" 291925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 29207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.impact" 292125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 29227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-NC.action" 292325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 29247c478bd9Sstevel@tonic-gate# 29257c478bd9Sstevel@tonic-gate# code: SUN4U-8005-PR 29267c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho 29277c478bd9Sstevel@tonic-gate# 29287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.type" 29297c478bd9Sstevel@tonic-gatemsgstr "Fault" 29307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.severity" 29317c478bd9Sstevel@tonic-gatemsgstr "Critical" 29327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.description" 293325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 29347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.response" 293525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 29367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.impact" 293725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 29387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-PR.action" 293925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 29407c478bd9Sstevel@tonic-gate# 29417c478bd9Sstevel@tonic-gate# code: SUN4U-8005-Q4 29427c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho 29437c478bd9Sstevel@tonic-gate# 29447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.type" 29457c478bd9Sstevel@tonic-gatemsgstr "Fault" 29467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.severity" 29477c478bd9Sstevel@tonic-gatemsgstr "Critical" 29487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.description" 294925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 29507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.response" 295125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 29527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.impact" 295325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 29547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-Q4.action" 295525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 29567c478bd9Sstevel@tonic-gate# 29577c478bd9Sstevel@tonic-gate# code: SUN4U-8005-RD 29587c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho 29597c478bd9Sstevel@tonic-gate# 29607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.type" 29617c478bd9Sstevel@tonic-gatemsgstr "Fault" 29627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.severity" 29637c478bd9Sstevel@tonic-gatemsgstr "Critical" 29647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.description" 296525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 29667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.response" 296725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 29687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.impact" 296925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 29707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-RD.action" 297125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 29727c478bd9Sstevel@tonic-gate# 29737c478bd9Sstevel@tonic-gate# code: SUN4U-8005-SH 29747c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho 29757c478bd9Sstevel@tonic-gate# 29767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.type" 29777c478bd9Sstevel@tonic-gatemsgstr "Fault" 29787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.severity" 29797c478bd9Sstevel@tonic-gatemsgstr "Critical" 29807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.description" 298125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 29827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.response" 298325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 29847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.impact" 298525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 29867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-SH.action" 298725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 29887c478bd9Sstevel@tonic-gate# 29897c478bd9Sstevel@tonic-gate# code: SUN4U-8005-T3 29907c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho 29917c478bd9Sstevel@tonic-gate# 29927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.type" 29937c478bd9Sstevel@tonic-gatemsgstr "Fault" 29947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.severity" 29957c478bd9Sstevel@tonic-gatemsgstr "Critical" 29967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.description" 299725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 29987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.response" 299925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 30007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.impact" 300125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 30027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-T3.action" 300325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 30047c478bd9Sstevel@tonic-gate# 30057c478bd9Sstevel@tonic-gate# code: SUN4U-8005-UY 30067c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho 30077c478bd9Sstevel@tonic-gate# 30087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.type" 30097c478bd9Sstevel@tonic-gatemsgstr "Fault" 30107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.severity" 30117c478bd9Sstevel@tonic-gatemsgstr "Critical" 30127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.description" 301325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 30147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.response" 301525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 30167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.impact" 301725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 30187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-UY.action" 301925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 30207c478bd9Sstevel@tonic-gate# 30217c478bd9Sstevel@tonic-gate# code: SUN4U-8005-V5 30227c478bd9Sstevel@tonic-gate# keys: fault.io.tomatillo 30237c478bd9Sstevel@tonic-gate# 30247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.type" 30257c478bd9Sstevel@tonic-gatemsgstr "Fault" 30267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.severity" 30277c478bd9Sstevel@tonic-gatemsgstr "Critical" 30287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.description" 302925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 30307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.response" 303125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 30327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.impact" 303325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 30347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-V5.action" 303525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 30367c478bd9Sstevel@tonic-gate# 30377c478bd9Sstevel@tonic-gate# code: SUN4U-8005-WS 30387c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.tomatillo 30397c478bd9Sstevel@tonic-gate# 30407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.type" 30417c478bd9Sstevel@tonic-gatemsgstr "Fault" 30427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.severity" 30437c478bd9Sstevel@tonic-gatemsgstr "Critical" 30447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.description" 304525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 30467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.response" 304725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 30487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.impact" 304925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 30507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-WS.action" 305125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 30527c478bd9Sstevel@tonic-gate# 30537c478bd9Sstevel@tonic-gate# code: SUN4U-8005-XA 30547c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.tomatillo 30557c478bd9Sstevel@tonic-gate# 30567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.type" 30577c478bd9Sstevel@tonic-gatemsgstr "Fault" 30587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.severity" 30597c478bd9Sstevel@tonic-gatemsgstr "Critical" 30607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.description" 306125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 30627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.response" 306325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 30647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.impact" 306525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 30667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-XA.action" 306725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 30687c478bd9Sstevel@tonic-gate# 30697c478bd9Sstevel@tonic-gate# code: SUN4U-8005-YP 30707c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo 30717c478bd9Sstevel@tonic-gate# 30727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.type" 30737c478bd9Sstevel@tonic-gatemsgstr "Fault" 30747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.severity" 30757c478bd9Sstevel@tonic-gatemsgstr "Critical" 30767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.description" 307725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 30787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.response" 307925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 30807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.impact" 308125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 30827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8005-YP.action" 308325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 30847c478bd9Sstevel@tonic-gate# 30857c478bd9Sstevel@tonic-gate# code: SUN4U-8006-04 30867c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.tomatillo 30877c478bd9Sstevel@tonic-gate# 30887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.type" 30897c478bd9Sstevel@tonic-gatemsgstr "Fault" 30907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.severity" 30917c478bd9Sstevel@tonic-gatemsgstr "Critical" 30927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.description" 309325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 30947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.response" 309525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 30967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.impact" 309725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 30987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-04.action" 309925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 31007c478bd9Sstevel@tonic-gate# 31017c478bd9Sstevel@tonic-gate# code: SUN4U-8006-1R 31027c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo 31037c478bd9Sstevel@tonic-gate# 31047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.type" 31057c478bd9Sstevel@tonic-gatemsgstr "Fault" 31067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.severity" 31077c478bd9Sstevel@tonic-gatemsgstr "Critical" 31087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.description" 310925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 31107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.response" 311125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 31127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.impact" 311325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 31147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-1R.action" 311525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 31167c478bd9Sstevel@tonic-gate# 31177c478bd9Sstevel@tonic-gate# code: SUN4U-8006-2C 31187c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.tomatillo 31197c478bd9Sstevel@tonic-gate# 31207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.type" 31217c478bd9Sstevel@tonic-gatemsgstr "Fault" 31227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.severity" 31237c478bd9Sstevel@tonic-gatemsgstr "Critical" 31247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.description" 312525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 31267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.response" 312725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 31287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.impact" 312925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 31307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-2C.action" 313125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 31327c478bd9Sstevel@tonic-gate# 31337c478bd9Sstevel@tonic-gate# code: SUN4U-8006-3Q 31347c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo 31357c478bd9Sstevel@tonic-gate# 31367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.type" 31377c478bd9Sstevel@tonic-gatemsgstr "Fault" 31387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.severity" 31397c478bd9Sstevel@tonic-gatemsgstr "Critical" 31407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.description" 314125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 31427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.response" 314325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 31447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.impact" 314525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 31467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-3Q.action" 314725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 31487c478bd9Sstevel@tonic-gate# 31497c478bd9Sstevel@tonic-gate# code: SUN4U-8006-4E 31507c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.tomatillo 31517c478bd9Sstevel@tonic-gate# 31527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.type" 31537c478bd9Sstevel@tonic-gatemsgstr "Fault" 31547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.severity" 31557c478bd9Sstevel@tonic-gatemsgstr "Critical" 31567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.description" 315725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 31587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.response" 315925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 31607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.impact" 316125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 31627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-4E.action" 316325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 31647c478bd9Sstevel@tonic-gate# 31657c478bd9Sstevel@tonic-gate# code: SUN4U-8006-5J 31667c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo 31677c478bd9Sstevel@tonic-gate# 31687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.type" 31697c478bd9Sstevel@tonic-gatemsgstr "Fault" 31707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.severity" 31717c478bd9Sstevel@tonic-gatemsgstr "Critical" 31727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.description" 317325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 31747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.response" 317525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 31767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.impact" 317725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 31787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-5J.action" 317925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 31807c478bd9Sstevel@tonic-gate# 31817c478bd9Sstevel@tonic-gate# code: SUN4U-8006-62 31827c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo 31837c478bd9Sstevel@tonic-gate# 31847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.type" 31857c478bd9Sstevel@tonic-gatemsgstr "Fault" 31867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.severity" 31877c478bd9Sstevel@tonic-gatemsgstr "Critical" 31887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.description" 318925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 31907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.response" 319125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 31927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.impact" 319325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 31947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-62.action" 319525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 31967c478bd9Sstevel@tonic-gate# 31977c478bd9Sstevel@tonic-gate# code: SUN4U-8006-7X 31987c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo 31997c478bd9Sstevel@tonic-gate# 32007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.type" 32017c478bd9Sstevel@tonic-gatemsgstr "Fault" 32027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.severity" 32037c478bd9Sstevel@tonic-gatemsgstr "Critical" 32047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.description" 320525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 32067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.response" 320725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 32087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.impact" 320925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 32107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-7X.action" 321125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 32127c478bd9Sstevel@tonic-gate# 32137c478bd9Sstevel@tonic-gate# code: SUN4U-8006-8P 32147c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo 32157c478bd9Sstevel@tonic-gate# 32167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.type" 32177c478bd9Sstevel@tonic-gatemsgstr "Fault" 32187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.severity" 32197c478bd9Sstevel@tonic-gatemsgstr "Critical" 32207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.description" 322125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 32227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.response" 322325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 32247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.impact" 322525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 32267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-8P.action" 322725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 32287c478bd9Sstevel@tonic-gate# 32297c478bd9Sstevel@tonic-gate# code: SUN4U-8006-9A 32307c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo 32317c478bd9Sstevel@tonic-gate# 32327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.type" 32337c478bd9Sstevel@tonic-gatemsgstr "Fault" 32347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.severity" 32357c478bd9Sstevel@tonic-gatemsgstr "Critical" 32367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.description" 323725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 32387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.response" 323925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 32407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.impact" 324125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 32427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-9A.action" 324325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 32447c478bd9Sstevel@tonic-gate# 32457c478bd9Sstevel@tonic-gate# code: SUN4U-8006-AS 32467c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo 32477c478bd9Sstevel@tonic-gate# 32487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.type" 32497c478bd9Sstevel@tonic-gatemsgstr "Fault" 32507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.severity" 32517c478bd9Sstevel@tonic-gatemsgstr "Critical" 32527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.description" 325325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 32547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.response" 325525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 32567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.impact" 325725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 32587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-AS.action" 325925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 32607c478bd9Sstevel@tonic-gate# 32617c478bd9Sstevel@tonic-gate# code: SUN4U-8006-C5 32627c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo 32637c478bd9Sstevel@tonic-gate# 32647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.type" 32657c478bd9Sstevel@tonic-gatemsgstr "Fault" 32667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.severity" 32677c478bd9Sstevel@tonic-gatemsgstr "Critical" 32687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.description" 326925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 32707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.response" 327125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 32727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.impact" 327325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 32747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-C5.action" 327525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 32767c478bd9Sstevel@tonic-gate# 32777c478bd9Sstevel@tonic-gate# code: SUN4U-8006-DY 32787c478bd9Sstevel@tonic-gate# keys: fault.io.pci.device fault.io.tomatillo 32797c478bd9Sstevel@tonic-gate# 32807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.type" 32817c478bd9Sstevel@tonic-gatemsgstr "Fault" 32827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.severity" 32837c478bd9Sstevel@tonic-gatemsgstr "Critical" 32847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.description" 328525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 32867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.response" 328725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 32887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.impact" 328925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 32907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-DY.action" 329125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 32927c478bd9Sstevel@tonic-gate# 32937c478bd9Sstevel@tonic-gate# code: SUN4U-8006-E3 32947c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo 32957c478bd9Sstevel@tonic-gate# 32967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.type" 32977c478bd9Sstevel@tonic-gatemsgstr "Fault" 32987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.severity" 32997c478bd9Sstevel@tonic-gatemsgstr "Critical" 33007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.description" 330125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 33027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.response" 330325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 33047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.impact" 330525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 33067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-E3.action" 330725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 33087c478bd9Sstevel@tonic-gate# 33097c478bd9Sstevel@tonic-gate# code: SUN4U-8006-FH 33107c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo 33117c478bd9Sstevel@tonic-gate# 33127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.type" 33137c478bd9Sstevel@tonic-gatemsgstr "Fault" 33147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.severity" 33157c478bd9Sstevel@tonic-gatemsgstr "Critical" 33167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.description" 331725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 33187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.response" 331925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 33207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.impact" 332125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 33227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-FH.action" 332325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 33247c478bd9Sstevel@tonic-gate# 33257c478bd9Sstevel@tonic-gate# code: SUN4U-8006-GD 33267c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo 33277c478bd9Sstevel@tonic-gate# 33287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.type" 33297c478bd9Sstevel@tonic-gatemsgstr "Fault" 33307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.severity" 33317c478bd9Sstevel@tonic-gatemsgstr "Critical" 33327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.description" 333325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 33347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.response" 333525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 33367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.impact" 333725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 33387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-GD.action" 333925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 33407c478bd9Sstevel@tonic-gate# 33417c478bd9Sstevel@tonic-gate# code: SUN4U-8006-HQ 33427c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo 33437c478bd9Sstevel@tonic-gate# 33447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.type" 33457c478bd9Sstevel@tonic-gatemsgstr "Fault" 33467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.severity" 33477c478bd9Sstevel@tonic-gatemsgstr "Critical" 33487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.description" 334925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 33507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.response" 335125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 33527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.impact" 335325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 33547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-HQ.action" 335525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 33567c478bd9Sstevel@tonic-gate# 33577c478bd9Sstevel@tonic-gate# code: SUN4U-8006-JC 33587c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo 33597c478bd9Sstevel@tonic-gate# 33607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.type" 33617c478bd9Sstevel@tonic-gatemsgstr "Fault" 33627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.severity" 33637c478bd9Sstevel@tonic-gatemsgstr "Critical" 33647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.description" 336525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 33667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.response" 336725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 33687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.impact" 336925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 33707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-JC.action" 337125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 33727c478bd9Sstevel@tonic-gate# 33737c478bd9Sstevel@tonic-gate# code: SUN4U-8006-KR 33747c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo 33757c478bd9Sstevel@tonic-gate# 33767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.type" 33777c478bd9Sstevel@tonic-gatemsgstr "Fault" 33787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.severity" 33797c478bd9Sstevel@tonic-gatemsgstr "Critical" 33807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.description" 338125cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 33827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.response" 338325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 33847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.impact" 338525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 33867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-KR.action" 338725cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 33887c478bd9Sstevel@tonic-gate# 33897c478bd9Sstevel@tonic-gate# code: SUN4U-8006-L4 33907c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo 33917c478bd9Sstevel@tonic-gate# 33927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.type" 33937c478bd9Sstevel@tonic-gatemsgstr "Fault" 33947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.severity" 33957c478bd9Sstevel@tonic-gatemsgstr "Critical" 33967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.description" 339725cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 33987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.response" 339925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 34007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.impact" 340125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 34027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-L4.action" 340325cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 34047c478bd9Sstevel@tonic-gate# 34057c478bd9Sstevel@tonic-gate# code: SUN4U-8006-MX 34067c478bd9Sstevel@tonic-gate# keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 34077c478bd9Sstevel@tonic-gate# 34087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.type" 34097c478bd9Sstevel@tonic-gatemsgstr "Fault" 34107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.severity" 34117c478bd9Sstevel@tonic-gatemsgstr "Critical" 34127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.description" 341325cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 34147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.response" 341525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 34167c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.impact" 341725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 34187c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-MX.action" 341925cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 34207c478bd9Sstevel@tonic-gate# 34217c478bd9Sstevel@tonic-gate# code: SUN4U-8006-N2 34227c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 34237c478bd9Sstevel@tonic-gate# 34247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.type" 34257c478bd9Sstevel@tonic-gatemsgstr "Fault" 34267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.severity" 34277c478bd9Sstevel@tonic-gatemsgstr "Critical" 34287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.description" 342925cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 34307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.response" 343125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 34327c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.impact" 343325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 34347c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-N2.action" 343525cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 34367c478bd9Sstevel@tonic-gate# 34377c478bd9Sstevel@tonic-gate# code: SUN4U-8006-PJ 34387c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 34397c478bd9Sstevel@tonic-gate# 34407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.type" 34417c478bd9Sstevel@tonic-gatemsgstr "Fault" 34427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.severity" 34437c478bd9Sstevel@tonic-gatemsgstr "Critical" 34447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.description" 344525cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 34467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.response" 344725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 34487c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.impact" 344925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 34507c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-PJ.action" 345125cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 34527c478bd9Sstevel@tonic-gate# 34537c478bd9Sstevel@tonic-gate# code: SUN4U-8006-QE 34547c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 34557c478bd9Sstevel@tonic-gate# 34567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.type" 34577c478bd9Sstevel@tonic-gatemsgstr "Fault" 34587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.severity" 34597c478bd9Sstevel@tonic-gatemsgstr "Critical" 34607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.description" 346125cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 34627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.response" 346325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 34647c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.impact" 346525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 34667c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-QE.action" 346725cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 34687c478bd9Sstevel@tonic-gate# 34697c478bd9Sstevel@tonic-gate# code: SUN4U-8006-R5 34707c478bd9Sstevel@tonic-gate# keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 34717c478bd9Sstevel@tonic-gate# 34727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.type" 34737c478bd9Sstevel@tonic-gatemsgstr "Fault" 34747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.severity" 34757c478bd9Sstevel@tonic-gatemsgstr "Critical" 34767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.description" 347725cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 34787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.response" 347925cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 34807c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.impact" 348125cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 34827c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-R5.action" 348325cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 34847c478bd9Sstevel@tonic-gate# 34857c478bd9Sstevel@tonic-gate# code: SUN4U-8006-SS 34867c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 34877c478bd9Sstevel@tonic-gate# 34887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.type" 34897c478bd9Sstevel@tonic-gatemsgstr "Fault" 34907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.severity" 34917c478bd9Sstevel@tonic-gatemsgstr "Critical" 34927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.description" 349325cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 34947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.response" 349525cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 34967c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.impact" 349725cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 34987c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-SS.action" 349925cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 35007c478bd9Sstevel@tonic-gate# 35017c478bd9Sstevel@tonic-gate# code: SUN4U-8006-TA 35027c478bd9Sstevel@tonic-gate# keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 35037c478bd9Sstevel@tonic-gate# 35047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.type" 35057c478bd9Sstevel@tonic-gatemsgstr "Fault" 35067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.severity" 35077c478bd9Sstevel@tonic-gatemsgstr "Critical" 35087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.description" 350925cf1a30Sjl139090msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." 35107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.response" 351125cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 35127c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.impact" 351325cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 35147c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-TA.action" 351525cf1a30Sjl139090msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" 35167c478bd9Sstevel@tonic-gate# 35177c478bd9Sstevel@tonic-gate# code: SUN4U-8006-UP 35187c478bd9Sstevel@tonic-gate# keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo 35197c478bd9Sstevel@tonic-gate# 35207c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.type" 35217c478bd9Sstevel@tonic-gatemsgstr "Fault" 35227c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.severity" 35237c478bd9Sstevel@tonic-gatemsgstr "Critical" 35247c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.description" 352525cf1a30Sjl139090msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." 35267c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.response" 352725cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 35287c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.impact" 352925cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 35307c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-UP.action" 353125cf1a30Sjl139090msgstr "\n\nUse fmdump -v -u <EVENT_ID> to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" 35327c478bd9Sstevel@tonic-gate# 35337c478bd9Sstevel@tonic-gate# code: SUN4U-8006-VD 35347c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.dcache 35357c478bd9Sstevel@tonic-gate# 35367c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.type" 35377c478bd9Sstevel@tonic-gatemsgstr "Fault" 35387c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.severity" 35397c478bd9Sstevel@tonic-gatemsgstr "Major" 35407c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.description" 354125cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 35427c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.response" 354325cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 35447c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.impact" 354525cf1a30Sjl139090msgstr "System performance may be affected." 35467c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-VD.action" 354725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 35487c478bd9Sstevel@tonic-gate# 35497c478bd9Sstevel@tonic-gate# code: SUN4U-8006-WH 35507c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.icache 35517c478bd9Sstevel@tonic-gate# 35527c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.type" 35537c478bd9Sstevel@tonic-gatemsgstr "Fault" 35547c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.severity" 35557c478bd9Sstevel@tonic-gatemsgstr "Major" 35567c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.description" 355725cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 35587c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.response" 355925cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 35607c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.impact" 356125cf1a30Sjl139090msgstr "System performance may be affected." 35627c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-WH.action" 356325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 35647c478bd9Sstevel@tonic-gate# 35657c478bd9Sstevel@tonic-gate# code: SUN4U-8006-X3 35667c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachedata 35677c478bd9Sstevel@tonic-gate# 35687c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.type" 35697c478bd9Sstevel@tonic-gatemsgstr "Fault" 35707c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.severity" 35717c478bd9Sstevel@tonic-gatemsgstr "Major" 35727c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.description" 357325cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 35747c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.response" 357525cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 35767c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.impact" 357725cf1a30Sjl139090msgstr "System performance may be affected." 35787c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-X3.action" 357925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 35807c478bd9Sstevel@tonic-gate# 35817c478bd9Sstevel@tonic-gate# code: SUN4U-8006-YY 35827c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.l2cachetag 35837c478bd9Sstevel@tonic-gate# 35847c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.type" 35857c478bd9Sstevel@tonic-gatemsgstr "Fault" 35867c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.severity" 35877c478bd9Sstevel@tonic-gatemsgstr "Major" 35887c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.description" 358925cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 35907c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.response" 359125cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 35927c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.impact" 359325cf1a30Sjl139090msgstr "System performance may be affected." 35947c478bd9Sstevel@tonic-gatemsgid "SUN4U-8006-YY.action" 359525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 35967c478bd9Sstevel@tonic-gate# 35977c478bd9Sstevel@tonic-gate# code: SUN4U-8007-03 35987c478bd9Sstevel@tonic-gate# keys: fault.cpu.ultraSPARC-IIIiplus.fpu 35997c478bd9Sstevel@tonic-gate# 36007c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.type" 36017c478bd9Sstevel@tonic-gatemsgstr "Fault" 36027c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.severity" 36037c478bd9Sstevel@tonic-gatemsgstr "Major" 36047c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.description" 360525cf1a30Sjl139090msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." 36067c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.response" 360725cf1a30Sjl139090msgstr "The fault manager will attempt to remove the affected CPU from service." 36087c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.impact" 360925cf1a30Sjl139090msgstr "System performance may be affected." 36107c478bd9Sstevel@tonic-gatemsgid "SUN4U-8007-03.action" 361125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 3612d00f0155Sayznaga# 3613d00f0155Sayznaga# code: SUN4U-8007-1Y 3614d00f0155Sayznaga# keys: fault.asic.cds.dp 3615d00f0155Sayznaga# 3616d00f0155Sayznagamsgid "SUN4U-8007-1Y.type" 3617d00f0155Sayznagamsgstr "Fault" 3618d00f0155Sayznagamsgid "SUN4U-8007-1Y.severity" 3619d00f0155Sayznagamsgstr "Critical" 3620d00f0155Sayznagamsgid "SUN4U-8007-1Y.description" 362125cf1a30Sjl139090msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." 3622d00f0155Sayznagamsgid "SUN4U-8007-1Y.response" 362325cf1a30Sjl139090msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" 3624d00f0155Sayznagamsgid "SUN4U-8007-1Y.impact" 362525cf1a30Sjl139090msgstr "System performace may be affected.\n" 3626d00f0155Sayznagamsgid "SUN4U-8007-1Y.action" 362725cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n" 3628d00f0155Sayznaga# 3629d00f0155Sayznaga# code: SUN4U-8007-2D 3630d00f0155Sayznaga# keys: fault.asic.dx.dp 3631d00f0155Sayznaga# 3632d00f0155Sayznagamsgid "SUN4U-8007-2D.type" 3633d00f0155Sayznagamsgstr "Fault" 3634d00f0155Sayznagamsgid "SUN4U-8007-2D.severity" 3635d00f0155Sayznagamsgstr "Critical" 3636d00f0155Sayznagamsgid "SUN4U-8007-2D.description" 363725cf1a30Sjl139090msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." 3638d00f0155Sayznagamsgid "SUN4U-8007-2D.response" 363925cf1a30Sjl139090msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" 3640d00f0155Sayznagamsgid "SUN4U-8007-2D.impact" 364125cf1a30Sjl139090msgstr "System performace may be affected.\n" 3642d00f0155Sayznagamsgid "SUN4U-8007-2D.action" 364325cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n" 3644d00f0155Sayznaga# 3645d00f0155Sayznaga# code: SUN4U-8007-3H 3646d00f0155Sayznaga# keys: fault.asic.sdi.dp 3647d00f0155Sayznaga# 3648d00f0155Sayznagamsgid "SUN4U-8007-3H.type" 3649d00f0155Sayznagamsgstr "Fault" 3650d00f0155Sayznagamsgid "SUN4U-8007-3H.severity" 3651d00f0155Sayznagamsgstr "Critical" 3652d00f0155Sayznagamsgid "SUN4U-8007-3H.description" 365325cf1a30Sjl139090msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." 3654d00f0155Sayznagamsgid "SUN4U-8007-3H.response" 365525cf1a30Sjl139090msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" 3656d00f0155Sayznagamsgid "SUN4U-8007-3H.impact" 365725cf1a30Sjl139090msgstr "System performace may be affected.\n" 3658d00f0155Sayznagamsgid "SUN4U-8007-3H.action" 365925cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n" 3660d00f0155Sayznaga# 3661d00f0155Sayznaga# code: SUN4U-8007-4A 3662d00f0155Sayznaga# keys: fault.asic.cp.dp 3663d00f0155Sayznaga# 3664d00f0155Sayznagamsgid "SUN4U-8007-4A.type" 3665d00f0155Sayznagamsgstr "Fault" 3666d00f0155Sayznagamsgid "SUN4U-8007-4A.severity" 3667d00f0155Sayznagamsgstr "Critical" 3668d00f0155Sayznagamsgid "SUN4U-8007-4A.description" 366925cf1a30Sjl139090msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." 3670d00f0155Sayznagamsgid "SUN4U-8007-4A.response" 367125cf1a30Sjl139090msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" 3672d00f0155Sayznagamsgid "SUN4U-8007-4A.impact" 367325cf1a30Sjl139090msgstr "System performace may be affected.\n" 3674d00f0155Sayznagamsgid "SUN4U-8007-4A.action" 367525cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n" 3676d00f0155Sayznaga# 3677d00f0155Sayznaga# code: SUN4U-8007-5P 3678d00f0155Sayznaga# keys: fault.asic.rp.dp 3679d00f0155Sayznaga# 3680d00f0155Sayznagamsgid "SUN4U-8007-5P.type" 3681d00f0155Sayznagamsgstr "Fault" 3682d00f0155Sayznagamsgid "SUN4U-8007-5P.severity" 3683d00f0155Sayznagamsgstr "Critical" 3684d00f0155Sayznagamsgid "SUN4U-8007-5P.description" 368525cf1a30Sjl139090msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." 3686d00f0155Sayznagamsgid "SUN4U-8007-5P.response" 368725cf1a30Sjl139090msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" 3688d00f0155Sayznagamsgid "SUN4U-8007-5P.impact" 368925cf1a30Sjl139090msgstr "System performace may be affected.\n" 3690d00f0155Sayznagamsgid "SUN4U-8007-5P.action" 369125cf1a30Sjl139090msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u <EVENT-ID> can also be used, but the SC is authoritative.\n" 369225cf1a30Sjl139090# 369325cf1a30Sjl139090# code: SUN4U-8007-65 369425cf1a30Sjl139090# keys: fault.io.oberon 369525cf1a30Sjl139090# 369625cf1a30Sjl139090msgid "SUN4U-8007-65.type" 369725cf1a30Sjl139090msgstr "Fault" 369825cf1a30Sjl139090msgid "SUN4U-8007-65.severity" 369925cf1a30Sjl139090msgstr "Critical" 370025cf1a30Sjl139090msgid "SUN4U-8007-65.description" 370125cf1a30Sjl139090msgstr "Oberon PCI-Express hostbridge fault\n Refer to %s for more information." 370225cf1a30Sjl139090msgid "SUN4U-8007-65.response" 370325cf1a30Sjl139090msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." 370425cf1a30Sjl139090msgid "SUN4U-8007-65.impact" 370525cf1a30Sjl139090msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." 370625cf1a30Sjl139090msgid "SUN4U-8007-65.action" 370725cf1a30Sjl139090msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." 370825cf1a30Sjl139090# 370925cf1a30Sjl139090# code: SUN4U-8007-7S 371025cf1a30Sjl139090# keys: fault.cpu.SPARC64-VI.chip 371125cf1a30Sjl139090# 371225cf1a30Sjl139090msgid "SUN4U-8007-7S.type" 371325cf1a30Sjl139090msgstr "Fault" 371425cf1a30Sjl139090msgid "SUN4U-8007-7S.severity" 371525cf1a30Sjl139090msgstr "Critical" 371625cf1a30Sjl139090msgid "SUN4U-8007-7S.description" 3717*9dd0f810Scindimsgstr "The number of errors associated with this CHIP has exceeded acceptable levels.\nRefer to %s for more information. Refer to %s for more information." 371825cf1a30Sjl139090msgid "SUN4U-8007-7S.response" 3719*9dd0f810Scindimsgstr "An attempt will be made to remove the affected CHIP from service." 372025cf1a30Sjl139090msgid "SUN4U-8007-7S.impact" 3721*9dd0f810Scindimsgstr "The system will not be functioning at the same performance level with the CHIP removal." 372225cf1a30Sjl139090msgid "SUN4U-8007-7S.action" 3723*9dd0f810Scindimsgstr "Schedule a repair procedure to replace the affected CHIP. Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nCHIP." 372425cf1a30Sjl139090# 372525cf1a30Sjl139090# code: SUN4U-8007-8J 372625cf1a30Sjl139090# keys: fault.cpu.SPARC64-VI.core 372725cf1a30Sjl139090# 372825cf1a30Sjl139090msgid "SUN4U-8007-8J.type" 372925cf1a30Sjl139090msgstr "Fault" 373025cf1a30Sjl139090msgid "SUN4U-8007-8J.severity" 373125cf1a30Sjl139090msgstr "Critical" 373225cf1a30Sjl139090msgid "SUN4U-8007-8J.description" 3733*9dd0f810Scindimsgstr "The number of errors associated with this CHIP has exceeded acceptable levels.\nRefer to %s for more information. Refer to %s for more information." 373425cf1a30Sjl139090msgid "SUN4U-8007-8J.response" 3735*9dd0f810Scindimsgstr "An attempt will be made to remove the affected CORE from service." 373625cf1a30Sjl139090msgid "SUN4U-8007-8J.impact" 3737*9dd0f810Scindimsgstr "The system will not be functioning at the same performance level with the CORE removal." 373825cf1a30Sjl139090msgid "SUN4U-8007-8J.action" 3739*9dd0f810Scindimsgstr "Schedule a repair procedure to replace the affected CORE. Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nCORE.\n" 374025cf1a30Sjl139090# 374125cf1a30Sjl139090# code: SUN4U-8007-9E 374225cf1a30Sjl139090# keys: fault.cpu.SPARC64-VI.strand 374325cf1a30Sjl139090# 374425cf1a30Sjl139090msgid "SUN4U-8007-9E.type" 374525cf1a30Sjl139090msgstr "Fault" 374625cf1a30Sjl139090msgid "SUN4U-8007-9E.severity" 374725cf1a30Sjl139090msgstr "Critical" 374825cf1a30Sjl139090msgid "SUN4U-8007-9E.description" 3749*9dd0f810Scindimsgstr "The number of errors associated with this STRAND has exceeded acceptable levels.\nRefer to %s for more information. Refer to %s for more information." 375025cf1a30Sjl139090msgid "SUN4U-8007-9E.response" 3751*9dd0f810Scindimsgstr "An attempt will be made to remove the affected STRAND from service." 375225cf1a30Sjl139090msgid "SUN4U-8007-9E.impact" 3753*9dd0f810Scindimsgstr "The system will not be functioning at the same performance level with the STRAND removal." 375425cf1a30Sjl139090msgid "SUN4U-8007-9E.action" 3755*9dd0f810Scindimsgstr "Schedule a repair procedure to replace the affected STRAND. Use fmdump -v -u <EVENT_ID>\nto identify the smallest CPU/Strand ID of the affected CORE on this\nSTRAND.\n" 375600d0963fSdilpreet# 375700d0963fSdilpreet# code: SUN4U-8007-AX 375800d0963fSdilpreet# keys: fault.io.pci.device-invreq fault.io.tomatillo 375900d0963fSdilpreet# 376000d0963fSdilpreetmsgid "SUN4U-8007-AX.type" 376100d0963fSdilpreetmsgstr "Fault" 376200d0963fSdilpreetmsgid "SUN4U-8007-AX.severity" 376300d0963fSdilpreetmsgstr "Critical" 376400d0963fSdilpreetmsgid "SUN4U-8007-AX.description" 376500d0963fSdilpreetmsgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n Refer to %s for more information." 376600d0963fSdilpreetmsgid "SUN4U-8007-AX.response" 376700d0963fSdilpreetmsgstr "One or more device instances may be disabled\n" 376800d0963fSdilpreetmsgid "SUN4U-8007-AX.impact" 376900d0963fSdilpreetmsgstr "Loss of services provided by the device instances associated with this fault\n" 377000d0963fSdilpreetmsgid "SUN4U-8007-AX.action" 3771*9dd0f810Scindimsgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmdump -v -u <EVENT_ID> to identify the devices or contact Sun for support.\n" 3772