xref: /titanic_51/usr/src/cmd/fm/dicts/SUN4V.po (revision 53a7b6b6763f5865522a76e5e887390a8f4777d7)
1#
2# Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24#
25# DO NOT EDIT -- this file is generated by the Event Registry.
26#
27#
28# code: SUN4V-8000-1S
29# keys: fault.cpu.ultraSPARC-T1.ireg
30#
31msgid "SUN4V-8000-1S.type"
32msgstr "Fault"
33msgid "SUN4V-8000-1S.severity"
34msgstr "Minor"
35msgid "SUN4V-8000-1S.description"
36msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
37msgid "SUN4V-8000-1S.response"
38msgstr "The fault manager will attempt to remove the affected CPU from service."
39msgid "SUN4V-8000-1S.impact"
40msgstr "System performance may be affected."
41msgid "SUN4V-8000-1S.action"
42msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
43#
44# code: SUN4V-8000-2A
45# keys: fault.cpu.ultraSPARC-T1.freg
46#
47msgid "SUN4V-8000-2A.type"
48msgstr "Fault"
49msgid "SUN4V-8000-2A.severity"
50msgstr "Major"
51msgid "SUN4V-8000-2A.description"
52msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
53msgid "SUN4V-8000-2A.response"
54msgstr "None"
55msgid "SUN4V-8000-2A.impact"
56msgstr "System performance may be affected."
57msgid "SUN4V-8000-2A.action"
58msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
59#
60# code: SUN4V-8000-3P
61# keys: fault.cpu.ultraSPARC-T1.itlb
62#
63msgid "SUN4V-8000-3P.type"
64msgstr "Fault"
65msgid "SUN4V-8000-3P.severity"
66msgstr "Minor"
67msgid "SUN4V-8000-3P.description"
68msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
69msgid "SUN4V-8000-3P.response"
70msgstr "The fault manager will attempt to remove the affected CPU from service."
71msgid "SUN4V-8000-3P.impact"
72msgstr "System performance may be affected.\n"
73msgid "SUN4V-8000-3P.action"
74msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
75#
76# code: SUN4V-8000-4D
77# keys: fault.cpu.ultraSPARC-T1.dtlb
78#
79msgid "SUN4V-8000-4D.type"
80msgstr "Fault"
81msgid "SUN4V-8000-4D.severity"
82msgstr "Minor"
83msgid "SUN4V-8000-4D.description"
84msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
85msgid "SUN4V-8000-4D.response"
86msgstr "The fault manager will attempt to remove the affected CPU from service."
87msgid "SUN4V-8000-4D.impact"
88msgstr "System performance may be affected.\n"
89msgid "SUN4V-8000-4D.action"
90msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
91#
92# code: SUN4V-8000-5H
93# keys: fault.cpu.ultraSPARC-T1.icache
94#
95msgid "SUN4V-8000-5H.type"
96msgstr "Fault"
97msgid "SUN4V-8000-5H.severity"
98msgstr "Minor"
99msgid "SUN4V-8000-5H.description"
100msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
101msgid "SUN4V-8000-5H.response"
102msgstr "The fault manager will attempt to remove the affected CPU from service."
103msgid "SUN4V-8000-5H.impact"
104msgstr "System performance may be affected.\n"
105msgid "SUN4V-8000-5H.action"
106msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
107#
108# code: SUN4V-8000-63
109# keys: fault.cpu.ultraSPARC-T1.dcache
110#
111msgid "SUN4V-8000-63.type"
112msgstr "Fault"
113msgid "SUN4V-8000-63.severity"
114msgstr "Minor"
115msgid "SUN4V-8000-63.description"
116msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
117msgid "SUN4V-8000-63.response"
118msgstr "The fault manager will attempt to remove the affected CPU from service."
119msgid "SUN4V-8000-63.impact"
120msgstr "System performance may be affected.\n"
121msgid "SUN4V-8000-63.action"
122msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
123#
124# code: SUN4V-8000-7Y
125# keys: fault.cpu.ultraSPARC-T1.mau
126#
127msgid "SUN4V-8000-7Y.type"
128msgstr "Fault"
129msgid "SUN4V-8000-7Y.severity"
130msgstr "Major"
131msgid "SUN4V-8000-7Y.description"
132msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
133msgid "SUN4V-8000-7Y.response"
134msgstr "None"
135msgid "SUN4V-8000-7Y.impact"
136msgstr "System performance may be affected.\n"
137msgid "SUN4V-8000-7Y.action"
138msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
139#
140# code: SUN4V-8000-8Q
141# keys: fault.cpu.ultraSPARC-T1.l2cachedata
142#
143msgid "SUN4V-8000-8Q.type"
144msgstr "Fault"
145msgid "SUN4V-8000-8Q.severity"
146msgstr "Critical"
147msgid "SUN4V-8000-8Q.description"
148msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
149msgid "SUN4V-8000-8Q.response"
150msgstr "None"
151msgid "SUN4V-8000-8Q.impact"
152msgstr "System performance may be affected.\n"
153msgid "SUN4V-8000-8Q.action"
154msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
155#
156# code: SUN4V-8000-9C
157# keys: fault.cpu.ultraSPARC-T1.l2cachetag
158#
159msgid "SUN4V-8000-9C.type"
160msgstr "Fault"
161msgid "SUN4V-8000-9C.severity"
162msgstr "Critical"
163msgid "SUN4V-8000-9C.description"
164msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
165msgid "SUN4V-8000-9C.response"
166msgstr "None"
167msgid "SUN4V-8000-9C.impact"
168msgstr "System performance may be affected.\n"
169msgid "SUN4V-8000-9C.action"
170msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
171#
172# code: SUN4V-8000-AR
173# keys: fault.cpu.ultraSPARC-T1.l2cachectl
174#
175msgid "SUN4V-8000-AR.type"
176msgstr "Fault"
177msgid "SUN4V-8000-AR.severity"
178msgstr "Critical"
179msgid "SUN4V-8000-AR.description"
180msgstr "The number of errors associated with this CPU has exceeded \n         acceptable levels.  Refer to %s for more information."
181msgid "SUN4V-8000-AR.response"
182msgstr "None"
183msgid "SUN4V-8000-AR.impact"
184msgstr "System performance may be affected.\n"
185msgid "SUN4V-8000-AR.action"
186msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>."
187#
188# code: SUN4V-8000-C4
189# keys: fault.memory.page
190#
191msgid "SUN4V-8000-C4.type"
192msgstr "Fault"
193msgid "SUN4V-8000-C4.severity"
194msgstr "Minor"
195msgid "SUN4V-8000-C4.description"
196msgstr "The number of errors associated with this memory module continues to exceed acceptable levels.  Refer to %s for more information."
197msgid "SUN4V-8000-C4.response"
198msgstr "An attempt will be made to remove this memory page from service."
199msgid "SUN4V-8000-C4.impact"
200msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation."
201msgid "SUN4V-8000-C4.action"
202msgstr "No repair action is recommended at this time."
203#
204# code: SUN4V-8000-DX
205# keys: fault.memory.dimm
206#
207msgid "SUN4V-8000-DX.type"
208msgstr "Fault"
209msgid "SUN4V-8000-DX.severity"
210msgstr "Major"
211msgid "SUN4V-8000-DX.description"
212msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
213msgid "SUN4V-8000-DX.response"
214msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
215msgid "SUN4V-8000-DX.impact"
216msgstr "Total system memory capacity will be reduced as pages are retired."
217msgid "SUN4V-8000-DX.action"
218msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
219#
220# code: SUN4V-8000-E2
221# keys: fault.memory.bank
222#
223msgid "SUN4V-8000-E2.type"
224msgstr "Fault"
225msgid "SUN4V-8000-E2.severity"
226msgstr "Critical"
227msgid "SUN4V-8000-E2.description"
228msgstr "The number of errors associated with this memory module has exceeded acceptable levels.  Refer to %s for more information."
229msgid "SUN4V-8000-E2.response"
230msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported."
231msgid "SUN4V-8000-E2.impact"
232msgstr "Total system memory capacity will be reduced as pages are retired."
233msgid "SUN4V-8000-E2.action"
234msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module."
235#
236# code: SUN4V-8000-FJ
237# keys: fault.memory.link-c
238#
239msgid "SUN4V-8000-FJ.type"
240msgstr "Fault"
241msgid "SUN4V-8000-FJ.severity"
242msgstr "Major"
243msgid "SUN4V-8000-FJ.description"
244msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
245msgid "SUN4V-8000-FJ.response"
246msgstr "No automated response.\n"
247msgid "SUN4V-8000-FJ.impact"
248msgstr "System performance may be impacted.\n"
249msgid "SUN4V-8000-FJ.action"
250msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
251#
252# code: SUN4V-8000-GE
253# keys: fault.cpu.ultraSPARC-T2.ireg
254#
255msgid "SUN4V-8000-GE.type"
256msgstr "Fault"
257msgid "SUN4V-8000-GE.severity"
258msgstr "Minor"
259msgid "SUN4V-8000-GE.description"
260msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
261msgid "SUN4V-8000-GE.response"
262msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
263msgid "SUN4V-8000-GE.impact"
264msgstr "System performance may be affected. \n"
265msgid "SUN4V-8000-GE.action"
266msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
267#
268# code: SUN4V-8000-HP
269# keys: fault.cpu.ultraSPARC-T2.freg
270#
271msgid "SUN4V-8000-HP.type"
272msgstr "Fault"
273msgid "SUN4V-8000-HP.severity"
274msgstr "Minor"
275msgid "SUN4V-8000-HP.description"
276msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
277msgid "SUN4V-8000-HP.response"
278msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
279msgid "SUN4V-8000-HP.impact"
280msgstr "System performance may be affected. \n"
281msgid "SUN4V-8000-HP.action"
282msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
283#
284# code: SUN4V-8000-JA
285# keys: fault.cpu.ultraSPARC-T2.misc_reg
286#
287msgid "SUN4V-8000-JA.type"
288msgstr "Fault"
289msgid "SUN4V-8000-JA.severity"
290msgstr "Minor"
291msgid "SUN4V-8000-JA.description"
292msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
293msgid "SUN4V-8000-JA.response"
294msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
295msgid "SUN4V-8000-JA.impact"
296msgstr "System performance may be affected. \n"
297msgid "SUN4V-8000-JA.action"
298msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
299#
300# code: SUN4V-8000-KS
301# keys: fault.cpu.ultraSPARC-T2.itlb
302#
303msgid "SUN4V-8000-KS.type"
304msgstr "Fault"
305msgid "SUN4V-8000-KS.severity"
306msgstr "Major"
307msgid "SUN4V-8000-KS.description"
308msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
309msgid "SUN4V-8000-KS.response"
310msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
311msgid "SUN4V-8000-KS.impact"
312msgstr "System performance is likely to be affected. \n"
313msgid "SUN4V-8000-KS.action"
314msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
315#
316# code: SUN4V-8000-L5
317# keys: fault.cpu.ultraSPARC-T2.dtlb
318#
319msgid "SUN4V-8000-L5.type"
320msgstr "Fault"
321msgid "SUN4V-8000-L5.severity"
322msgstr "Major"
323msgid "SUN4V-8000-L5.description"
324msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
325msgid "SUN4V-8000-L5.response"
326msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
327msgid "SUN4V-8000-L5.impact"
328msgstr "System performance is likely to be affected. \n"
329msgid "SUN4V-8000-L5.action"
330msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
331#
332# code: SUN4V-8000-MY
333# keys: fault.cpu.ultraSPARC-T2.icache
334#
335msgid "SUN4V-8000-MY.type"
336msgstr "Fault"
337msgid "SUN4V-8000-MY.severity"
338msgstr "Major"
339msgid "SUN4V-8000-MY.description"
340msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
341msgid "SUN4V-8000-MY.response"
342msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
343msgid "SUN4V-8000-MY.impact"
344msgstr "System performance is likely to be affected. \n"
345msgid "SUN4V-8000-MY.action"
346msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
347#
348# code: SUN4V-8000-N3
349# keys: fault.cpu.ultraSPARC-T2.dcache
350#
351msgid "SUN4V-8000-N3.type"
352msgstr "Fault"
353msgid "SUN4V-8000-N3.severity"
354msgstr "Major"
355msgid "SUN4V-8000-N3.description"
356msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
357msgid "SUN4V-8000-N3.response"
358msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
359msgid "SUN4V-8000-N3.impact"
360msgstr "System performance is likely to be affected. \n"
361msgid "SUN4V-8000-N3.action"
362msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
363#
364# code: SUN4V-8000-PH
365# keys: fault.cpu.ultraSPARC-T2.mau
366#
367msgid "SUN4V-8000-PH.type"
368msgstr "Fault"
369msgid "SUN4V-8000-PH.severity"
370msgstr "Major"
371msgid "SUN4V-8000-PH.description"
372msgstr "The number of modular arithmetic unit errors associated with this unit has exceeded acceptable levels.\n  Refer to %s for more information."
373msgid "SUN4V-8000-PH.response"
374msgstr "Cryptographic software will not use this modular arithmetic unit.\n"
375msgid "SUN4V-8000-PH.impact"
376msgstr "System performance is likely to be affected. \n"
377msgid "SUN4V-8000-PH.action"
378msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
379#
380# code: SUN4V-8000-QD
381# keys: fault.cpu.ultraSPARC-T2.l2data-c
382#
383msgid "SUN4V-8000-QD.type"
384msgstr "Fault"
385msgid "SUN4V-8000-QD.severity"
386msgstr "Critical"
387msgid "SUN4V-8000-QD.description"
388msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
389msgid "SUN4V-8000-QD.response"
390msgstr "No automated response.\n"
391msgid "SUN4V-8000-QD.impact"
392msgstr "System performance is likely to be affected. \n"
393msgid "SUN4V-8000-QD.action"
394msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
395#
396# code: SUN4V-8000-R4
397# keys: fault.cpu.ultraSPARC-T2.l2cachetag
398#
399msgid "SUN4V-8000-R4.type"
400msgstr "Fault"
401msgid "SUN4V-8000-R4.severity"
402msgstr "Critical"
403msgid "SUN4V-8000-R4.description"
404msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n  Refer to %s for more information."
405msgid "SUN4V-8000-R4.response"
406msgstr "No automated response.\n"
407msgid "SUN4V-8000-R4.impact"
408msgstr "System performance is likely to be affected. \n"
409msgid "SUN4V-8000-R4.action"
410msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
411#
412# code: SUN4V-8000-SR
413# keys: fault.cpu.ultraSPARC-T2.l2cachectl
414#
415msgid "SUN4V-8000-SR.type"
416msgstr "Fault"
417msgid "SUN4V-8000-SR.severity"
418msgstr "Critical"
419msgid "SUN4V-8000-SR.description"
420msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n  Refer to %s for more information."
421msgid "SUN4V-8000-SR.response"
422msgstr "No automated response.\n"
423msgid "SUN4V-8000-SR.impact"
424msgstr "System performance is likely to be affected. System may be unstable.\n"
425msgid "SUN4V-8000-SR.action"
426msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
427#
428# code: SUN4V-8000-TC
429# keys: fault.memory.link-u
430#
431msgid "SUN4V-8000-TC.type"
432msgstr "Fault"
433msgid "SUN4V-8000-TC.severity"
434msgstr "Critical"
435msgid "SUN4V-8000-TC.description"
436msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n  Refer to %s for more information."
437msgid "SUN4V-8000-TC.response"
438msgstr "No automated response.\n"
439msgid "SUN4V-8000-TC.impact"
440msgstr "System performance may be impacted.\n"
441msgid "SUN4V-8000-TC.action"
442msgstr "At convenient time, try reseating the memory module.  If problem persists,\ncontact Sun to schedule part replacement.\n"
443#
444# code: SUN4V-8000-UQ
445# keys: fault.cpu.ultraSPARC-T2.l2data-u
446#
447msgid "SUN4V-8000-UQ.type"
448msgstr "Fault"
449msgid "SUN4V-8000-UQ.severity"
450msgstr "Critical"
451msgid "SUN4V-8000-UQ.description"
452msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
453msgid "SUN4V-8000-UQ.response"
454msgstr "No automated response.\n"
455msgid "SUN4V-8000-UQ.impact"
456msgstr "System performance is likely to be affected. \n"
457msgid "SUN4V-8000-UQ.action"
458msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
459#
460# code: SUN4V-8000-VE
461# keys: fault.cpu.ultraSPARC-T1.l2data-c
462#
463msgid "SUN4V-8000-VE.type"
464msgstr "Fault"
465msgid "SUN4V-8000-VE.severity"
466msgstr "Critical"
467msgid "SUN4V-8000-VE.description"
468msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
469msgid "SUN4V-8000-VE.response"
470msgstr "No automated response.\n"
471msgid "SUN4V-8000-VE.impact"
472msgstr "System performance is likely to be affected. \n"
473msgid "SUN4V-8000-VE.action"
474msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
475#
476# code: SUN4V-8000-WJ
477# keys: fault.cpu.ultraSPARC-T1.l2data-u
478#
479msgid "SUN4V-8000-WJ.type"
480msgstr "Fault"
481msgid "SUN4V-8000-WJ.severity"
482msgstr "Critical"
483msgid "SUN4V-8000-WJ.description"
484msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
485msgid "SUN4V-8000-WJ.response"
486msgstr "No automated response.\n"
487msgid "SUN4V-8000-WJ.impact"
488msgstr "System performance is likely to be affected. \n"
489msgid "SUN4V-8000-WJ.action"
490msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
491#
492# code: SUN4V-8000-X2
493# keys: fault.memory.datapath
494#
495msgid "SUN4V-8000-X2.type"
496msgstr "Fault"
497msgid "SUN4V-8000-X2.severity"
498msgstr "Major"
499msgid "SUN4V-8000-X2.description"
500msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n  Refer to %s for more information."
501msgid "SUN4V-8000-X2.response"
502msgstr "Error reports from the affected components will be logged for examination by Sun.\n"
503msgid "SUN4V-8000-X2.impact"
504msgstr "System performance and stability may be affected. \n"
505msgid "SUN4V-8000-X2.action"
506msgstr "Contact your service provider for further diagnosis.\n"
507#
508# code: SUN4V-8000-YX
509# keys: fault.io.n2.ncu
510#
511msgid "SUN4V-8000-YX.type"
512msgstr "Fault"
513msgid "SUN4V-8000-YX.severity"
514msgstr "Critical"
515msgid "SUN4V-8000-YX.description"
516msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n  Refer to %s for more information."
517msgid "SUN4V-8000-YX.response"
518msgstr "One or more device instances may be disabled\n"
519msgid "SUN4V-8000-YX.impact"
520msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
521msgid "SUN4V-8000-YX.action"
522msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
523#
524# code: SUN4V-8001-02
525# keys: fault.io.n2.dmu
526#
527msgid "SUN4V-8001-02.type"
528msgstr "Fault"
529msgid "SUN4V-8001-02.severity"
530msgstr "Critical"
531msgid "SUN4V-8001-02.description"
532msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n  Refer to %s for more information."
533msgid "SUN4V-8001-02.response"
534msgstr "One or more device instances may be disabled\n"
535msgid "SUN4V-8001-02.impact"
536msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
537msgid "SUN4V-8001-02.action"
538msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
539#
540# code: SUN4V-8001-1X
541# keys: fault.io.n2.niu
542#
543msgid "SUN4V-8001-1X.type"
544msgstr "Fault"
545msgid "SUN4V-8001-1X.severity"
546msgstr "Critical"
547msgid "SUN4V-8001-1X.description"
548msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n  Refer to %s for more information."
549msgid "SUN4V-8001-1X.response"
550msgstr "One or more device instances may be disabled\n"
551msgid "SUN4V-8001-1X.impact"
552msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
553msgid "SUN4V-8001-1X.action"
554msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
555#
556# code: SUN4V-8001-2E
557# keys: fault.io.n2.siu
558#
559msgid "SUN4V-8001-2E.type"
560msgstr "Fault"
561msgid "SUN4V-8001-2E.severity"
562msgstr "Critical"
563msgid "SUN4V-8001-2E.description"
564msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n  Refer to %s for more information."
565msgid "SUN4V-8001-2E.response"
566msgstr "One or more device instances may be disabled\n"
567msgid "SUN4V-8001-2E.impact"
568msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
569msgid "SUN4V-8001-2E.action"
570msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
571#
572# code: SUN4V-8001-3J
573# keys: fault.io.n2.soc
574#
575msgid "SUN4V-8001-3J.type"
576msgstr "Fault"
577msgid "SUN4V-8001-3J.severity"
578msgstr "Critical"
579msgid "SUN4V-8001-3J.description"
580msgstr "A problem was detected in N2's SOC\n  Refer to %s for more information."
581msgid "SUN4V-8001-3J.response"
582msgstr "One or more device instances may be disabled\n"
583msgid "SUN4V-8001-3J.impact"
584msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
585msgid "SUN4V-8001-3J.action"
586msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
587#
588# code: SUN4V-8001-4C
589# keys: fault.io.n2.crossbar
590#
591msgid "SUN4V-8001-4C.type"
592msgstr "Fault"
593msgid "SUN4V-8001-4C.severity"
594msgstr "Critical"
595msgid "SUN4V-8001-4C.description"
596msgstr "A problem was detected in the crossbar of the N2's SOC\n  Refer to %s for more information."
597msgid "SUN4V-8001-4C.response"
598msgstr "One or more device instances may be disabled\n"
599msgid "SUN4V-8001-4C.impact"
600msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
601msgid "SUN4V-8001-4C.action"
602msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
603#
604# code: SUN4V-8001-5Q
605# keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch
606#
607msgid "SUN4V-8001-5Q.type"
608msgstr "Fault"
609msgid "SUN4V-8001-5Q.severity"
610msgstr "Critical"
611msgid "SUN4V-8001-5Q.description"
612msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n  Refer to %s for more information."
613msgid "SUN4V-8001-5Q.response"
614msgstr "One or more device instances may be disabled\n"
615msgid "SUN4V-8001-5Q.impact"
616msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
617msgid "SUN4V-8001-5Q.action"
618msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
619#
620# code: SUN4V-8001-64
621# keys: fault.io.vf.ncx
622#
623msgid "SUN4V-8001-64.type"
624msgstr "Fault"
625msgid "SUN4V-8001-64.severity"
626msgstr "Critical"
627msgid "SUN4V-8001-64.description"
628msgstr "An uncorrectable problem was detected in the NCX subsystem.\n  Refer to %s for more information."
629msgid "SUN4V-8001-64.response"
630msgstr "One or more device instances may be disabled\n"
631msgid "SUN4V-8001-64.impact"
632msgstr "Loss of services provided by the device\ninstances associated with this fault\n"
633msgid "SUN4V-8001-64.action"
634msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n"
635#
636# code: SUN4V-8001-7R
637# keys: fault.memory.link-f
638#
639msgid "SUN4V-8001-7R.type"
640msgstr "Fault"
641msgid "SUN4V-8001-7R.severity"
642msgstr "Major"
643msgid "SUN4V-8001-7R.description"
644msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller.  A lane failover has taken place.\n  Refer to %s for more information."
645msgid "SUN4V-8001-7R.response"
646msgstr "No automated response.\n"
647msgid "SUN4V-8001-7R.impact"
648msgstr "System performance may be impacted.\n"
649msgid "SUN4V-8001-7R.action"
650msgstr "At convenient time, try reseating the memory module(s).  If problem persists,\ncontact Sun to schedule part replacement.\n"
651#
652# code: SUN4V-8001-8H
653# keys: fault.cpu.ultraSPARC-T2plus.ireg
654#
655msgid "SUN4V-8001-8H.type"
656msgstr "Fault"
657msgid "SUN4V-8001-8H.severity"
658msgstr "Minor"
659msgid "SUN4V-8001-8H.description"
660msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
661msgid "SUN4V-8001-8H.response"
662msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
663msgid "SUN4V-8001-8H.impact"
664msgstr "System performance may be affected. \n"
665msgid "SUN4V-8001-8H.action"
666msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
667#
668# code: SUN4V-8001-9D
669# keys: fault.cpu.ultraSPARC-T2plus.freg
670#
671msgid "SUN4V-8001-9D.type"
672msgstr "Fault"
673msgid "SUN4V-8001-9D.severity"
674msgstr "Minor"
675msgid "SUN4V-8001-9D.description"
676msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
677msgid "SUN4V-8001-9D.response"
678msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
679msgid "SUN4V-8001-9D.impact"
680msgstr "System performance may be affected. \n"
681msgid "SUN4V-8001-9D.action"
682msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
683#
684# code: SUN4V-8001-AY
685# keys: fault.cpu.ultraSPARC-T2plus.misc_reg
686#
687msgid "SUN4V-8001-AY.type"
688msgstr "Fault"
689msgid "SUN4V-8001-AY.severity"
690msgstr "Minor"
691msgid "SUN4V-8001-AY.description"
692msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
693msgid "SUN4V-8001-AY.response"
694msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n"
695msgid "SUN4V-8001-AY.impact"
696msgstr "System performance may be affected. \n"
697msgid "SUN4V-8001-AY.action"
698msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
699#
700# code: SUN4V-8001-C3
701# keys: fault.cpu.ultraSPARC-T2plus.itlb
702#
703msgid "SUN4V-8001-C3.type"
704msgstr "Fault"
705msgid "SUN4V-8001-C3.severity"
706msgstr "Major"
707msgid "SUN4V-8001-C3.description"
708msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
709msgid "SUN4V-8001-C3.response"
710msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
711msgid "SUN4V-8001-C3.impact"
712msgstr "System performance is likely to be affected. \n"
713msgid "SUN4V-8001-C3.action"
714msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
715#
716# code: SUN4V-8001-DS
717# keys: fault.cpu.ultraSPARC-T2plus.dtlb
718#
719msgid "SUN4V-8001-DS.type"
720msgstr "Fault"
721msgid "SUN4V-8001-DS.severity"
722msgstr "Major"
723msgid "SUN4V-8001-DS.description"
724msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
725msgid "SUN4V-8001-DS.response"
726msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
727msgid "SUN4V-8001-DS.impact"
728msgstr "System performance is likely to be affected. \n"
729msgid "SUN4V-8001-DS.action"
730msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
731#
732# code: SUN4V-8001-E5
733# keys: fault.cpu.ultraSPARC-T2plus.icache
734#
735msgid "SUN4V-8001-E5.type"
736msgstr "Fault"
737msgid "SUN4V-8001-E5.severity"
738msgstr "Major"
739msgid "SUN4V-8001-E5.description"
740msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
741msgid "SUN4V-8001-E5.response"
742msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
743msgid "SUN4V-8001-E5.impact"
744msgstr "System performance is likely to be affected. \n"
745msgid "SUN4V-8001-E5.action"
746msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
747#
748# code: SUN4V-8001-FP
749# keys: fault.cpu.ultraSPARC-T2plus.dcache
750#
751msgid "SUN4V-8001-FP.type"
752msgstr "Fault"
753msgid "SUN4V-8001-FP.severity"
754msgstr "Major"
755msgid "SUN4V-8001-FP.description"
756msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
757msgid "SUN4V-8001-FP.response"
758msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n"
759msgid "SUN4V-8001-FP.impact"
760msgstr "System performance is likely to be affected. \n"
761msgid "SUN4V-8001-FP.action"
762msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
763#
764# code: SUN4V-8001-GA
765# keys: fault.cpu.ultraSPARC-T2plus.mau
766#
767msgid "SUN4V-8001-GA.type"
768msgstr "Fault"
769msgid "SUN4V-8001-GA.severity"
770msgstr "Major"
771msgid "SUN4V-8001-GA.description"
772msgstr "The number of modular arithmetic unit errors associated with this thread has exceeded acceptable levels.\n  Refer to %s for more information."
773msgid "SUN4V-8001-GA.response"
774msgstr "Cryptographic software will not use this modular arithmetic unit.\n\n"
775msgid "SUN4V-8001-GA.impact"
776msgstr "System performance is likely to be affected. \n"
777msgid "SUN4V-8001-GA.action"
778msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
779#
780# code: SUN4V-8001-HJ
781# keys: fault.cpu.ultraSPARC-T2plus.l2data-c
782#
783msgid "SUN4V-8001-HJ.type"
784msgstr "Fault"
785msgid "SUN4V-8001-HJ.severity"
786msgstr "Critical"
787msgid "SUN4V-8001-HJ.description"
788msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
789msgid "SUN4V-8001-HJ.response"
790msgstr "No automated response.\n"
791msgid "SUN4V-8001-HJ.impact"
792msgstr "System performance is likely to be affected. \n"
793msgid "SUN4V-8001-HJ.action"
794msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
795#
796# code: SUN4V-8001-JE
797# keys: fault.cpu.ultraSPARC-T2plus.l2cachetag
798#
799msgid "SUN4V-8001-JE.type"
800msgstr "Fault"
801msgid "SUN4V-8001-JE.severity"
802msgstr "Critical"
803msgid "SUN4V-8001-JE.description"
804msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n  Refer to %s for more information."
805msgid "SUN4V-8001-JE.response"
806msgstr "No automated response.\n"
807msgid "SUN4V-8001-JE.impact"
808msgstr "System performance is likely to be affected. \n"
809msgid "SUN4V-8001-JE.action"
810msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
811#
812# code: SUN4V-8001-KX
813# keys: fault.cpu.ultraSPARC-T2plus.l2cachectl
814#
815msgid "SUN4V-8001-KX.type"
816msgstr "Fault"
817msgid "SUN4V-8001-KX.severity"
818msgstr "Critical"
819msgid "SUN4V-8001-KX.description"
820msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n  Refer to %s for more information."
821msgid "SUN4V-8001-KX.response"
822msgstr "No automated response.\n"
823msgid "SUN4V-8001-KX.impact"
824msgstr "System performance is likely to be affected. System may be unstable.\n"
825msgid "SUN4V-8001-KX.action"
826msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
827#
828# code: SUN4V-8001-L2
829# keys: fault.cpu.ultraSPARC-T2plus.l2data-u
830#
831msgid "SUN4V-8001-L2.type"
832msgstr "Fault"
833msgid "SUN4V-8001-L2.severity"
834msgstr "Critical"
835msgid "SUN4V-8001-L2.description"
836msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n  Refer to %s for more information."
837msgid "SUN4V-8001-L2.response"
838msgstr "No automated response.\n"
839msgid "SUN4V-8001-L2.impact"
840msgstr "System performance is likely to be affected. \n"
841msgid "SUN4V-8001-L2.action"
842msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
843#
844# code: SUN4V-8001-MR
845# keys: fault.cpu.ultraSPARC-T2plus.lfu-f
846#
847msgid "SUN4V-8001-MR.type"
848msgstr "Fault"
849msgid "SUN4V-8001-MR.severity"
850msgstr "Major"
851msgid "SUN4V-8001-MR.description"
852msgstr "A CPU chip's Link Framing Unit has stopped using a bad lane.\n  Refer to %s for more information."
853msgid "SUN4V-8001-MR.response"
854msgstr "No other automated response.\n"
855msgid "SUN4V-8001-MR.impact"
856msgstr "The system's capacity to correct transmission errors between CPU chips has been reduced.\n"
857msgid "SUN4V-8001-MR.action"
858msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
859#
860# code: SUN4V-8001-N4
861# keys: fault.cpu.ultraSPARC-T2plus.lfu-p
862#
863msgid "SUN4V-8001-N4.type"
864msgstr "Fault"
865msgid "SUN4V-8001-N4.severity"
866msgstr "Major"
867msgid "SUN4V-8001-N4.description"
868msgstr "A CPU chip's Link Framing Unit has encountered a protocol error.\n  Refer to %s for more information."
869msgid "SUN4V-8001-N4.response"
870msgstr "No automated response.\n"
871msgid "SUN4V-8001-N4.impact"
872msgstr "The system has most likely taken a fatal reset.\n"
873msgid "SUN4V-8001-N4.action"
874msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
875#
876# code: SUN4V-8001-PQ
877# keys: fault.cpu.ultraSPARC-T2plus.lfu-u
878#
879msgid "SUN4V-8001-PQ.type"
880msgstr "Fault"
881msgid "SUN4V-8001-PQ.severity"
882msgstr "Major"
883msgid "SUN4V-8001-PQ.description"
884msgstr "A CPU chip's Link Framing Unit has encountered an unrecoverable lane failure.\n  Refer to %s for more information."
885msgid "SUN4V-8001-PQ.response"
886msgstr "No automated response.\n"
887msgid "SUN4V-8001-PQ.impact"
888msgstr "The system's integrity is seriously compromised.\n"
889msgid "SUN4V-8001-PQ.action"
890msgstr "Do not rely on this system for mission-critical tasks.\nSchedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n"
891#
892# code: SUN4V-8001-QC
893# keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-u
894#
895msgid "SUN4V-8001-QC.type"
896msgstr "Fault"
897msgid "SUN4V-8001-QC.severity"
898msgstr "Critical"
899msgid "SUN4V-8001-QC.description"
900msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected a fatal\ninternal problem.\n  Refer to %s for more information."
901msgid "SUN4V-8001-QC.response"
902msgstr "No automated reponse.\n"
903msgid "SUN4V-8001-QC.impact"
904msgstr "The system's integrity is compromised.\n"
905msgid "SUN4V-8001-QC.action"
906msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
907#
908# code: SUN4V-8001-R3
909# keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-c
910#
911msgid "SUN4V-8001-R3.type"
912msgstr "Fault"
913msgid "SUN4V-8001-R3.severity"
914msgstr "Major"
915msgid "SUN4V-8001-R3.description"
916msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected an internal problem.\n  Refer to %s for more information."
917msgid "SUN4V-8001-R3.response"
918msgstr "No automated reponse.\n"
919msgid "SUN4V-8001-R3.impact"
920msgstr "The system's integrity is compromised.\n"
921msgid "SUN4V-8001-R3.action"
922msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
923#
924# code: SUN4V-8001-SY
925# keys: fault.cpu.ultraSPARC-T2plus.chip
926#
927msgid "SUN4V-8001-SY.type"
928msgstr "Fault"
929msgid "SUN4V-8001-SY.severity"
930msgstr "Critical"
931msgid "SUN4V-8001-SY.description"
932msgstr "An ultraSPARC-T2plus Interconnect has detected a fatal communication\nproblem with a CPU.\n  Refer to %s for more information."
933msgid "SUN4V-8001-SY.response"
934msgstr "No automated reponse.\n"
935msgid "SUN4V-8001-SY.impact"
936msgstr "The system's integrity is seriously compromised.\n"
937msgid "SUN4V-8001-SY.action"
938msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
939#
940# code: SUN4V-8001-TD
941# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-c fault.cpu.ultraSPARC-T2plus.chip
942#
943msgid "SUN4V-8001-TD.type"
944msgstr "Fault"
945msgid "SUN4V-8001-TD.severity"
946msgstr "Minor"
947msgid "SUN4V-8001-TD.description"
948msgstr "The number of CRC errors between an ultraSPARC-T2plus\nCoherency Interconnect and a CPU has exceeded acceptable levels.\n  Refer to %s for more information."
949msgid "SUN4V-8001-TD.response"
950msgstr "No automated reponse.\n"
951msgid "SUN4V-8001-TD.impact"
952msgstr "The system's integrity is seriously compromised.\n"
953msgid "SUN4V-8001-TD.action"
954msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
955#
956# code: SUN4V-8001-UH
957# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-f fault.cpu.ultraSPARC-T2plus.chip
958#
959msgid "SUN4V-8001-UH.type"
960msgstr "Fault"
961msgid "SUN4V-8001-UH.severity"
962msgstr "Major"
963msgid "SUN4V-8001-UH.description"
964msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a single-lane\nfailure communicating with a CPU.\n  Refer to %s for more information."
965msgid "SUN4V-8001-UH.response"
966msgstr "No automated reponse.\n"
967msgid "SUN4V-8001-UH.impact"
968msgstr "The system's performance may be impacted.\n"
969msgid "SUN4V-8001-UH.action"
970msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
971#
972# code: SUN4V-8001-VA
973# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u fault.cpu.ultraSPARC-T2plus.chip
974#
975msgid "SUN4V-8001-VA.type"
976msgstr "Fault"
977msgid "SUN4V-8001-VA.severity"
978msgstr "Critical"
979msgid "SUN4V-8001-VA.description"
980msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal\nfault commnicating with a CPU.\n  Refer to %s for more information."
981msgid "SUN4V-8001-VA.response"
982msgstr "No automated reponse.\n"
983msgid "SUN4V-8001-VA.impact"
984msgstr "The system's integrity is seriously compromised.\n"
985msgid "SUN4V-8001-VA.action"
986msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
987#
988# code: SUN4V-8001-WP
989# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u
990#
991msgid "SUN4V-8001-WP.type"
992msgstr "Fault"
993msgid "SUN4V-8001-WP.severity"
994msgstr "Critical"
995msgid "SUN4V-8001-WP.description"
996msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal internal\nfault and has automatically reset.\n  Refer to %s for more information."
997msgid "SUN4V-8001-WP.response"
998msgstr "No automated reponse.\n"
999msgid "SUN4V-8001-WP.impact"
1000msgstr "The system's integrity is seriously compromised.\n"
1001msgid "SUN4V-8001-WP.action"
1002msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1003#
1004# code: SUN4V-8001-X5
1005# keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-u fault.cpu.ultraSPARC-T2plus.chip
1006#
1007msgid "SUN4V-8001-X5.type"
1008msgstr "Fault"
1009msgid "SUN4V-8001-X5.severity"
1010msgstr "Critical"
1011msgid "SUN4V-8001-X5.description"
1012msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal communication\nfault with a CPU.\n  Refer to %s for more information."
1013msgid "SUN4V-8001-X5.response"
1014msgstr "No automated reponse.\n"
1015msgid "SUN4V-8001-X5.impact"
1016msgstr "The system's performance may be compromised.\n"
1017msgid "SUN4V-8001-X5.action"
1018msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1019#
1020# code: SUN4V-8001-YS
1021# keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c fault.cpu.ultraSPARC-T2plus.chip
1022#
1023msgid "SUN4V-8001-YS.type"
1024msgstr "Fault"
1025msgid "SUN4V-8001-YS.severity"
1026msgstr "Major"
1027msgid "SUN4V-8001-YS.description"
1028msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fault\ncommunicating with a CPU.\n  Refer to %s for more information."
1029msgid "SUN4V-8001-YS.response"
1030msgstr "No automated reponse.\n"
1031msgid "SUN4V-8001-YS.impact"
1032msgstr "The system's integrity may be seriously compromised.\n"
1033msgid "SUN4V-8001-YS.action"
1034msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1035#
1036# code: SUN4V-8002-0C
1037# keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
1038#
1039msgid "SUN4V-8002-0C.type"
1040msgstr "Fault"
1041msgid "SUN4V-8002-0C.severity"
1042msgstr "Major"
1043msgid "SUN4V-8002-0C.description"
1044msgstr "The ultraSPARC-T2plus Interconnect has detected a fault communicating\nwith the service processor.\n  Refer to %s for more information."
1045msgid "SUN4V-8002-0C.response"
1046msgstr "No automated reponse.\n"
1047msgid "SUN4V-8002-0C.impact"
1048msgstr "The system's performance may be impacted.\n"
1049msgid "SUN4V-8002-0C.action"
1050msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1051#
1052# code: SUN4V-8002-1Q
1053# keys: fault.asic.fpga fault.asic.ultraSPARC-T2plus.interconnect.gpd-c
1054#
1055msgid "SUN4V-8002-1Q.type"
1056msgstr "Fault"
1057msgid "SUN4V-8002-1Q.severity"
1058msgstr "Major"
1059msgid "SUN4V-8002-1Q.description"
1060msgstr "ultraSPARC-T2plus Coherency Interconnect detected a fault on the LPC bus.\n  Refer to %s for more information."
1061msgid "SUN4V-8002-1Q.response"
1062msgstr "No automated reponse.\n"
1063msgid "SUN4V-8002-1Q.impact"
1064msgstr "The system's performance may be impacted.\n"
1065msgid "SUN4V-8002-1Q.action"
1066msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1067#
1068# code: SUN4V-8002-24
1069# keys: fault.asic.ultraSPARC-T2plus.interconnect.asu
1070#
1071msgid "SUN4V-8002-24.type"
1072msgstr "Fault"
1073msgid "SUN4V-8002-24.severity"
1074msgstr "Critical"
1075msgid "SUN4V-8002-24.description"
1076msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal fault.\n  Refer to %s for more information."
1077msgid "SUN4V-8002-24.response"
1078msgstr "No automated reponse.\n"
1079msgid "SUN4V-8002-24.impact"
1080msgstr "The system's integrity is seriously compromised.\n"
1081msgid "SUN4V-8002-24.action"
1082msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n"
1083#
1084# code: SUN4V-8002-3R
1085# keys: fault.memory.dimm-page-retires-excessive
1086#
1087msgid "SUN4V-8002-3R.type"
1088msgstr "Fault"
1089msgid "SUN4V-8002-3R.severity"
1090msgstr "Major"
1091msgid "SUN4V-8002-3R.description"
1092msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.\n  Refer to %s for more information."
1093msgid "SUN4V-8002-3R.response"
1094msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.\n"
1095msgid "SUN4V-8002-3R.impact"
1096msgstr "Total system memory capacity has been reduced.\n"
1097msgid "SUN4V-8002-3R.action"
1098msgstr "Schedule a repair procedure to replace the DIMM.  Use fmadm faulty to identify the DIMM to replace.\n"
1099#
1100# code: SUN4V-8002-42
1101# keys: fault.memory.dimm-ue-imminent
1102#
1103msgid "SUN4V-8002-42.type"
1104msgstr "Fault"
1105msgid "SUN4V-8002-42.severity"
1106msgstr "Critical"
1107msgid "SUN4V-8002-42.description"
1108msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n  Refer to %s for more information."
1109msgid "SUN4V-8002-42.response"
1110msgstr "None at this time.\n"
1111msgid "SUN4V-8002-42.impact"
1112msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
1113msgid "SUN4V-8002-42.action"
1114msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"
1115#
1116# code: SUN4V-8002-5X
1117# keys: fault.memory.dram-ue-imminent
1118#
1119msgid "SUN4V-8002-5X.type"
1120msgstr "Fault"
1121msgid "SUN4V-8002-5X.severity"
1122msgstr "Critical"
1123msgid "SUN4V-8002-5X.description"
1124msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n  Refer to %s for more information."
1125msgid "SUN4V-8002-5X.response"
1126msgstr "None at this time.\n"
1127msgid "SUN4V-8002-5X.impact"
1128msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n"
1129msgid "SUN4V-8002-5X.action"
1130msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n"