1# 2# Copyright 2008 Sun Microsystems, Inc. All rights reserved. 3# Use is subject to license terms. 4# 5# CDDL HEADER START 6# 7# The contents of this file are subject to the terms of the 8# Common Development and Distribution License (the "License"). 9# You may not use this file except in compliance with the License. 10# 11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE 12# or http://www.opensolaris.org/os/licensing. 13# See the License for the specific language governing permissions 14# and limitations under the License. 15# 16# When distributing Covered Code, include this CDDL HEADER in each 17# file and include the License file at usr/src/OPENSOLARIS.LICENSE. 18# If applicable, add the following below this CDDL HEADER, with the 19# fields enclosed by brackets "[]" replaced with your own identifying 20# information: Portions Copyright [yyyy] [name of copyright owner] 21# 22# CDDL HEADER END 23# 24# 25# DO NOT EDIT -- this file is generated by the Event Registry. 26# 27# 28# code: SUN4V-8000-1S 29# keys: fault.cpu.ultraSPARC-T1.ireg 30# 31msgid "SUN4V-8000-1S.type" 32msgstr "Fault" 33msgid "SUN4V-8000-1S.severity" 34msgstr "Minor" 35msgid "SUN4V-8000-1S.description" 36msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 37msgid "SUN4V-8000-1S.response" 38msgstr "The fault manager will attempt to remove the affected CPU from service." 39msgid "SUN4V-8000-1S.impact" 40msgstr "System performance may be affected." 41msgid "SUN4V-8000-1S.action" 42msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 43# 44# code: SUN4V-8000-2A 45# keys: fault.cpu.ultraSPARC-T1.freg 46# 47msgid "SUN4V-8000-2A.type" 48msgstr "Fault" 49msgid "SUN4V-8000-2A.severity" 50msgstr "Major" 51msgid "SUN4V-8000-2A.description" 52msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 53msgid "SUN4V-8000-2A.response" 54msgstr "None" 55msgid "SUN4V-8000-2A.impact" 56msgstr "System performance may be affected." 57msgid "SUN4V-8000-2A.action" 58msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 59# 60# code: SUN4V-8000-3P 61# keys: fault.cpu.ultraSPARC-T1.itlb 62# 63msgid "SUN4V-8000-3P.type" 64msgstr "Fault" 65msgid "SUN4V-8000-3P.severity" 66msgstr "Minor" 67msgid "SUN4V-8000-3P.description" 68msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 69msgid "SUN4V-8000-3P.response" 70msgstr "The fault manager will attempt to remove the affected CPU from service." 71msgid "SUN4V-8000-3P.impact" 72msgstr "System performance may be affected.\n" 73msgid "SUN4V-8000-3P.action" 74msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 75# 76# code: SUN4V-8000-4D 77# keys: fault.cpu.ultraSPARC-T1.dtlb 78# 79msgid "SUN4V-8000-4D.type" 80msgstr "Fault" 81msgid "SUN4V-8000-4D.severity" 82msgstr "Minor" 83msgid "SUN4V-8000-4D.description" 84msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 85msgid "SUN4V-8000-4D.response" 86msgstr "The fault manager will attempt to remove the affected CPU from service." 87msgid "SUN4V-8000-4D.impact" 88msgstr "System performance may be affected.\n" 89msgid "SUN4V-8000-4D.action" 90msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 91# 92# code: SUN4V-8000-5H 93# keys: fault.cpu.ultraSPARC-T1.icache 94# 95msgid "SUN4V-8000-5H.type" 96msgstr "Fault" 97msgid "SUN4V-8000-5H.severity" 98msgstr "Minor" 99msgid "SUN4V-8000-5H.description" 100msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 101msgid "SUN4V-8000-5H.response" 102msgstr "The fault manager will attempt to remove the affected CPU from service." 103msgid "SUN4V-8000-5H.impact" 104msgstr "System performance may be affected.\n" 105msgid "SUN4V-8000-5H.action" 106msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 107# 108# code: SUN4V-8000-63 109# keys: fault.cpu.ultraSPARC-T1.dcache 110# 111msgid "SUN4V-8000-63.type" 112msgstr "Fault" 113msgid "SUN4V-8000-63.severity" 114msgstr "Minor" 115msgid "SUN4V-8000-63.description" 116msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 117msgid "SUN4V-8000-63.response" 118msgstr "The fault manager will attempt to remove the affected CPU from service." 119msgid "SUN4V-8000-63.impact" 120msgstr "System performance may be affected.\n" 121msgid "SUN4V-8000-63.action" 122msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 123# 124# code: SUN4V-8000-7Y 125# keys: fault.cpu.ultraSPARC-T1.mau 126# 127msgid "SUN4V-8000-7Y.type" 128msgstr "Fault" 129msgid "SUN4V-8000-7Y.severity" 130msgstr "Major" 131msgid "SUN4V-8000-7Y.description" 132msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 133msgid "SUN4V-8000-7Y.response" 134msgstr "None" 135msgid "SUN4V-8000-7Y.impact" 136msgstr "System performance may be affected.\n" 137msgid "SUN4V-8000-7Y.action" 138msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 139# 140# code: SUN4V-8000-8Q 141# keys: fault.cpu.ultraSPARC-T1.l2cachedata 142# 143msgid "SUN4V-8000-8Q.type" 144msgstr "Fault" 145msgid "SUN4V-8000-8Q.severity" 146msgstr "Critical" 147msgid "SUN4V-8000-8Q.description" 148msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 149msgid "SUN4V-8000-8Q.response" 150msgstr "None" 151msgid "SUN4V-8000-8Q.impact" 152msgstr "System performance may be affected.\n" 153msgid "SUN4V-8000-8Q.action" 154msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 155# 156# code: SUN4V-8000-9C 157# keys: fault.cpu.ultraSPARC-T1.l2cachetag 158# 159msgid "SUN4V-8000-9C.type" 160msgstr "Fault" 161msgid "SUN4V-8000-9C.severity" 162msgstr "Critical" 163msgid "SUN4V-8000-9C.description" 164msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 165msgid "SUN4V-8000-9C.response" 166msgstr "None" 167msgid "SUN4V-8000-9C.impact" 168msgstr "System performance may be affected.\n" 169msgid "SUN4V-8000-9C.action" 170msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 171# 172# code: SUN4V-8000-AR 173# keys: fault.cpu.ultraSPARC-T1.l2cachectl 174# 175msgid "SUN4V-8000-AR.type" 176msgstr "Fault" 177msgid "SUN4V-8000-AR.severity" 178msgstr "Critical" 179msgid "SUN4V-8000-AR.description" 180msgstr "The number of errors associated with this CPU has exceeded \n acceptable levels. Refer to %s for more information." 181msgid "SUN4V-8000-AR.response" 182msgstr "None" 183msgid "SUN4V-8000-AR.impact" 184msgstr "System performance may be affected.\n" 185msgid "SUN4V-8000-AR.action" 186msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>." 187# 188# code: SUN4V-8000-C4 189# keys: fault.memory.page 190# 191msgid "SUN4V-8000-C4.type" 192msgstr "Fault" 193msgid "SUN4V-8000-C4.severity" 194msgstr "Minor" 195msgid "SUN4V-8000-C4.description" 196msgstr "The number of errors associated with this memory module continues to exceed acceptable levels. Refer to %s for more information." 197msgid "SUN4V-8000-C4.response" 198msgstr "An attempt will be made to remove this memory page from service." 199msgid "SUN4V-8000-C4.impact" 200msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation." 201msgid "SUN4V-8000-C4.action" 202msgstr "No repair action is recommended at this time." 203# 204# code: SUN4V-8000-DX 205# keys: fault.memory.dimm 206# 207msgid "SUN4V-8000-DX.type" 208msgstr "Fault" 209msgid "SUN4V-8000-DX.severity" 210msgstr "Major" 211msgid "SUN4V-8000-DX.description" 212msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." 213msgid "SUN4V-8000-DX.response" 214msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 215msgid "SUN4V-8000-DX.impact" 216msgstr "Total system memory capacity will be reduced as pages are retired." 217msgid "SUN4V-8000-DX.action" 218msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module." 219# 220# code: SUN4V-8000-E2 221# keys: fault.memory.bank 222# 223msgid "SUN4V-8000-E2.type" 224msgstr "Fault" 225msgid "SUN4V-8000-E2.severity" 226msgstr "Critical" 227msgid "SUN4V-8000-E2.description" 228msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." 229msgid "SUN4V-8000-E2.response" 230msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." 231msgid "SUN4V-8000-E2.impact" 232msgstr "Total system memory capacity will be reduced as pages are retired." 233msgid "SUN4V-8000-E2.action" 234msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u <EVENT_ID> to identify the module." 235# 236# code: SUN4V-8000-FJ 237# keys: fault.memory.link-c 238# 239msgid "SUN4V-8000-FJ.type" 240msgstr "Fault" 241msgid "SUN4V-8000-FJ.severity" 242msgstr "Major" 243msgid "SUN4V-8000-FJ.description" 244msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information." 245msgid "SUN4V-8000-FJ.response" 246msgstr "No automated response.\n" 247msgid "SUN4V-8000-FJ.impact" 248msgstr "System performance may be impacted.\n" 249msgid "SUN4V-8000-FJ.action" 250msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n" 251# 252# code: SUN4V-8000-GE 253# keys: fault.cpu.ultraSPARC-T2.ireg 254# 255msgid "SUN4V-8000-GE.type" 256msgstr "Fault" 257msgid "SUN4V-8000-GE.severity" 258msgstr "Minor" 259msgid "SUN4V-8000-GE.description" 260msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 261msgid "SUN4V-8000-GE.response" 262msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 263msgid "SUN4V-8000-GE.impact" 264msgstr "System performance may be affected. \n" 265msgid "SUN4V-8000-GE.action" 266msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 267# 268# code: SUN4V-8000-HP 269# keys: fault.cpu.ultraSPARC-T2.freg 270# 271msgid "SUN4V-8000-HP.type" 272msgstr "Fault" 273msgid "SUN4V-8000-HP.severity" 274msgstr "Minor" 275msgid "SUN4V-8000-HP.description" 276msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 277msgid "SUN4V-8000-HP.response" 278msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 279msgid "SUN4V-8000-HP.impact" 280msgstr "System performance may be affected. \n" 281msgid "SUN4V-8000-HP.action" 282msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 283# 284# code: SUN4V-8000-JA 285# keys: fault.cpu.ultraSPARC-T2.misc_reg 286# 287msgid "SUN4V-8000-JA.type" 288msgstr "Fault" 289msgid "SUN4V-8000-JA.severity" 290msgstr "Minor" 291msgid "SUN4V-8000-JA.description" 292msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 293msgid "SUN4V-8000-JA.response" 294msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 295msgid "SUN4V-8000-JA.impact" 296msgstr "System performance may be affected. \n" 297msgid "SUN4V-8000-JA.action" 298msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 299# 300# code: SUN4V-8000-KS 301# keys: fault.cpu.ultraSPARC-T2.itlb 302# 303msgid "SUN4V-8000-KS.type" 304msgstr "Fault" 305msgid "SUN4V-8000-KS.severity" 306msgstr "Major" 307msgid "SUN4V-8000-KS.description" 308msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 309msgid "SUN4V-8000-KS.response" 310msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 311msgid "SUN4V-8000-KS.impact" 312msgstr "System performance is likely to be affected. \n" 313msgid "SUN4V-8000-KS.action" 314msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 315# 316# code: SUN4V-8000-L5 317# keys: fault.cpu.ultraSPARC-T2.dtlb 318# 319msgid "SUN4V-8000-L5.type" 320msgstr "Fault" 321msgid "SUN4V-8000-L5.severity" 322msgstr "Major" 323msgid "SUN4V-8000-L5.description" 324msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 325msgid "SUN4V-8000-L5.response" 326msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 327msgid "SUN4V-8000-L5.impact" 328msgstr "System performance is likely to be affected. \n" 329msgid "SUN4V-8000-L5.action" 330msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 331# 332# code: SUN4V-8000-MY 333# keys: fault.cpu.ultraSPARC-T2.icache 334# 335msgid "SUN4V-8000-MY.type" 336msgstr "Fault" 337msgid "SUN4V-8000-MY.severity" 338msgstr "Major" 339msgid "SUN4V-8000-MY.description" 340msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 341msgid "SUN4V-8000-MY.response" 342msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 343msgid "SUN4V-8000-MY.impact" 344msgstr "System performance is likely to be affected. \n" 345msgid "SUN4V-8000-MY.action" 346msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 347# 348# code: SUN4V-8000-N3 349# keys: fault.cpu.ultraSPARC-T2.dcache 350# 351msgid "SUN4V-8000-N3.type" 352msgstr "Fault" 353msgid "SUN4V-8000-N3.severity" 354msgstr "Major" 355msgid "SUN4V-8000-N3.description" 356msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 357msgid "SUN4V-8000-N3.response" 358msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 359msgid "SUN4V-8000-N3.impact" 360msgstr "System performance is likely to be affected. \n" 361msgid "SUN4V-8000-N3.action" 362msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 363# 364# code: SUN4V-8000-PH 365# keys: fault.cpu.ultraSPARC-T2.mau 366# 367msgid "SUN4V-8000-PH.type" 368msgstr "Fault" 369msgid "SUN4V-8000-PH.severity" 370msgstr "Major" 371msgid "SUN4V-8000-PH.description" 372msgstr "The number of modular arithmetic unit errors associated with this unit has exceeded acceptable levels.\n Refer to %s for more information." 373msgid "SUN4V-8000-PH.response" 374msgstr "Cryptographic software will not use this modular arithmetic unit.\n" 375msgid "SUN4V-8000-PH.impact" 376msgstr "System performance is likely to be affected. \n" 377msgid "SUN4V-8000-PH.action" 378msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 379# 380# code: SUN4V-8000-QD 381# keys: fault.cpu.ultraSPARC-T2.l2data-c 382# 383msgid "SUN4V-8000-QD.type" 384msgstr "Fault" 385msgid "SUN4V-8000-QD.severity" 386msgstr "Critical" 387msgid "SUN4V-8000-QD.description" 388msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information." 389msgid "SUN4V-8000-QD.response" 390msgstr "No automated response.\n" 391msgid "SUN4V-8000-QD.impact" 392msgstr "System performance is likely to be affected. \n" 393msgid "SUN4V-8000-QD.action" 394msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 395# 396# code: SUN4V-8000-R4 397# keys: fault.cpu.ultraSPARC-T2.l2cachetag 398# 399msgid "SUN4V-8000-R4.type" 400msgstr "Fault" 401msgid "SUN4V-8000-R4.severity" 402msgstr "Critical" 403msgid "SUN4V-8000-R4.description" 404msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n Refer to %s for more information." 405msgid "SUN4V-8000-R4.response" 406msgstr "No automated response.\n" 407msgid "SUN4V-8000-R4.impact" 408msgstr "System performance is likely to be affected. \n" 409msgid "SUN4V-8000-R4.action" 410msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 411# 412# code: SUN4V-8000-SR 413# keys: fault.cpu.ultraSPARC-T2.l2cachectl 414# 415msgid "SUN4V-8000-SR.type" 416msgstr "Fault" 417msgid "SUN4V-8000-SR.severity" 418msgstr "Critical" 419msgid "SUN4V-8000-SR.description" 420msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n Refer to %s for more information." 421msgid "SUN4V-8000-SR.response" 422msgstr "No automated response.\n" 423msgid "SUN4V-8000-SR.impact" 424msgstr "System performance is likely to be affected. System may be unstable.\n" 425msgid "SUN4V-8000-SR.action" 426msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 427# 428# code: SUN4V-8000-TC 429# keys: fault.memory.link-u 430# 431msgid "SUN4V-8000-TC.type" 432msgstr "Fault" 433msgid "SUN4V-8000-TC.severity" 434msgstr "Critical" 435msgid "SUN4V-8000-TC.description" 436msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. \n Refer to %s for more information." 437msgid "SUN4V-8000-TC.response" 438msgstr "No automated response.\n" 439msgid "SUN4V-8000-TC.impact" 440msgstr "System performance may be impacted.\n" 441msgid "SUN4V-8000-TC.action" 442msgstr "At convenient time, try reseating the memory module. If problem persists,\ncontact Sun to schedule part replacement.\n" 443# 444# code: SUN4V-8000-UQ 445# keys: fault.cpu.ultraSPARC-T2.l2data-u 446# 447msgid "SUN4V-8000-UQ.type" 448msgstr "Fault" 449msgid "SUN4V-8000-UQ.severity" 450msgstr "Critical" 451msgid "SUN4V-8000-UQ.description" 452msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information." 453msgid "SUN4V-8000-UQ.response" 454msgstr "No automated response.\n" 455msgid "SUN4V-8000-UQ.impact" 456msgstr "System performance is likely to be affected. \n" 457msgid "SUN4V-8000-UQ.action" 458msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 459# 460# code: SUN4V-8000-VE 461# keys: fault.cpu.ultraSPARC-T1.l2data-c 462# 463msgid "SUN4V-8000-VE.type" 464msgstr "Fault" 465msgid "SUN4V-8000-VE.severity" 466msgstr "Critical" 467msgid "SUN4V-8000-VE.description" 468msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information." 469msgid "SUN4V-8000-VE.response" 470msgstr "No automated response.\n" 471msgid "SUN4V-8000-VE.impact" 472msgstr "System performance is likely to be affected. \n" 473msgid "SUN4V-8000-VE.action" 474msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 475# 476# code: SUN4V-8000-WJ 477# keys: fault.cpu.ultraSPARC-T1.l2data-u 478# 479msgid "SUN4V-8000-WJ.type" 480msgstr "Fault" 481msgid "SUN4V-8000-WJ.severity" 482msgstr "Critical" 483msgid "SUN4V-8000-WJ.description" 484msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information." 485msgid "SUN4V-8000-WJ.response" 486msgstr "No automated response.\n" 487msgid "SUN4V-8000-WJ.impact" 488msgstr "System performance is likely to be affected. \n" 489msgid "SUN4V-8000-WJ.action" 490msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 491# 492# code: SUN4V-8000-X2 493# keys: fault.memory.datapath 494# 495msgid "SUN4V-8000-X2.type" 496msgstr "Fault" 497msgid "SUN4V-8000-X2.severity" 498msgstr "Major" 499msgid "SUN4V-8000-X2.description" 500msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system.\n Refer to %s for more information." 501msgid "SUN4V-8000-X2.response" 502msgstr "Error reports from the affected components will be logged for examination by Sun.\n" 503msgid "SUN4V-8000-X2.impact" 504msgstr "System performance and stability may be affected. \n" 505msgid "SUN4V-8000-X2.action" 506msgstr "Contact your service provider for further diagnosis.\n" 507# 508# code: SUN4V-8000-YX 509# keys: fault.io.n2.ncu 510# 511msgid "SUN4V-8000-YX.type" 512msgstr "Fault" 513msgid "SUN4V-8000-YX.severity" 514msgstr "Critical" 515msgid "SUN4V-8000-YX.description" 516msgstr "A problem was detected in the NCU subsystem of the N2's SOC\n Refer to %s for more information." 517msgid "SUN4V-8000-YX.response" 518msgstr "One or more device instances may be disabled\n" 519msgid "SUN4V-8000-YX.impact" 520msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 521msgid "SUN4V-8000-YX.action" 522msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 523# 524# code: SUN4V-8001-02 525# keys: fault.io.n2.dmu 526# 527msgid "SUN4V-8001-02.type" 528msgstr "Fault" 529msgid "SUN4V-8001-02.severity" 530msgstr "Critical" 531msgid "SUN4V-8001-02.description" 532msgstr "A problem was detected in the DMU subsystem of the N2's SOC\n Refer to %s for more information." 533msgid "SUN4V-8001-02.response" 534msgstr "One or more device instances may be disabled\n" 535msgid "SUN4V-8001-02.impact" 536msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 537msgid "SUN4V-8001-02.action" 538msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 539# 540# code: SUN4V-8001-1X 541# keys: fault.io.n2.niu 542# 543msgid "SUN4V-8001-1X.type" 544msgstr "Fault" 545msgid "SUN4V-8001-1X.severity" 546msgstr "Critical" 547msgid "SUN4V-8001-1X.description" 548msgstr "A problem was detected in the NIU subsystem of the N2's SOC\n Refer to %s for more information." 549msgid "SUN4V-8001-1X.response" 550msgstr "One or more device instances may be disabled\n" 551msgid "SUN4V-8001-1X.impact" 552msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 553msgid "SUN4V-8001-1X.action" 554msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 555# 556# code: SUN4V-8001-2E 557# keys: fault.io.n2.siu 558# 559msgid "SUN4V-8001-2E.type" 560msgstr "Fault" 561msgid "SUN4V-8001-2E.severity" 562msgstr "Critical" 563msgid "SUN4V-8001-2E.description" 564msgstr "A problem was detected in the SIU subsystem of the N2's SOC\n Refer to %s for more information." 565msgid "SUN4V-8001-2E.response" 566msgstr "One or more device instances may be disabled\n" 567msgid "SUN4V-8001-2E.impact" 568msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 569msgid "SUN4V-8001-2E.action" 570msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 571# 572# code: SUN4V-8001-3J 573# keys: fault.io.n2.soc 574# 575msgid "SUN4V-8001-3J.type" 576msgstr "Fault" 577msgid "SUN4V-8001-3J.severity" 578msgstr "Critical" 579msgid "SUN4V-8001-3J.description" 580msgstr "A problem was detected in N2's SOC\n Refer to %s for more information." 581msgid "SUN4V-8001-3J.response" 582msgstr "One or more device instances may be disabled\n" 583msgid "SUN4V-8001-3J.impact" 584msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 585msgid "SUN4V-8001-3J.action" 586msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 587# 588# code: SUN4V-8001-4C 589# keys: fault.io.n2.crossbar 590# 591msgid "SUN4V-8001-4C.type" 592msgstr "Fault" 593msgid "SUN4V-8001-4C.severity" 594msgstr "Critical" 595msgid "SUN4V-8001-4C.description" 596msgstr "A problem was detected in the crossbar of the N2's SOC\n Refer to %s for more information." 597msgid "SUN4V-8001-4C.response" 598msgstr "One or more device instances may be disabled\n" 599msgid "SUN4V-8001-4C.impact" 600msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 601msgid "SUN4V-8001-4C.action" 602msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 603# 604# code: SUN4V-8001-5Q 605# keys: fault.io.fire.fw-epkt fault.io.fire.sw-epkt fault.io.fire.sw-fw-mismatch 606# 607msgid "SUN4V-8001-5Q.type" 608msgstr "Fault" 609msgid "SUN4V-8001-5Q.severity" 610msgstr "Critical" 611msgid "SUN4V-8001-5Q.description" 612msgstr "An uncorrectable problem was detected in the IO hostbridge in which a mismatch\nin the SW and FW prevents the error to be properly handled.\n Refer to %s for more information." 613msgid "SUN4V-8001-5Q.response" 614msgstr "One or more device instances may be disabled\n" 615msgid "SUN4V-8001-5Q.impact" 616msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 617msgid "SUN4V-8001-5Q.action" 618msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 619# 620# code: SUN4V-8001-64 621# keys: fault.io.vf.ncx 622# 623msgid "SUN4V-8001-64.type" 624msgstr "Fault" 625msgid "SUN4V-8001-64.severity" 626msgstr "Critical" 627msgid "SUN4V-8001-64.description" 628msgstr "An uncorrectable problem was detected in the NCX subsystem.\n Refer to %s for more information." 629msgid "SUN4V-8001-64.response" 630msgstr "One or more device instances may be disabled\n" 631msgid "SUN4V-8001-64.impact" 632msgstr "Loss of services provided by the device\ninstances associated with this fault\n" 633msgid "SUN4V-8001-64.action" 634msgstr "Schedule a repair procedure to replace the affected\ndevice if necessary, or contact Sun for support.\n" 635# 636# code: SUN4V-8001-7R 637# keys: fault.memory.link-f 638# 639msgid "SUN4V-8001-7R.type" 640msgstr "Fault" 641msgid "SUN4V-8001-7R.severity" 642msgstr "Major" 643msgid "SUN4V-8001-7R.description" 644msgstr "A problem was detected in the interconnect between a memory DIMM module and\nits memory controller. A lane failover has taken place.\n Refer to %s for more information." 645msgid "SUN4V-8001-7R.response" 646msgstr "No automated response.\n" 647msgid "SUN4V-8001-7R.impact" 648msgstr "System performance may be impacted.\n" 649msgid "SUN4V-8001-7R.action" 650msgstr "At convenient time, try reseating the memory module(s). If problem persists,\ncontact Sun to schedule part replacement.\n" 651# 652# code: SUN4V-8001-8H 653# keys: fault.cpu.ultraSPARC-T2plus.ireg 654# 655msgid "SUN4V-8001-8H.type" 656msgstr "Fault" 657msgid "SUN4V-8001-8H.severity" 658msgstr "Minor" 659msgid "SUN4V-8001-8H.description" 660msgstr "The number of integer register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 661msgid "SUN4V-8001-8H.response" 662msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 663msgid "SUN4V-8001-8H.impact" 664msgstr "System performance may be affected. \n" 665msgid "SUN4V-8001-8H.action" 666msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 667# 668# code: SUN4V-8001-9D 669# keys: fault.cpu.ultraSPARC-T2plus.freg 670# 671msgid "SUN4V-8001-9D.type" 672msgstr "Fault" 673msgid "SUN4V-8001-9D.severity" 674msgstr "Minor" 675msgid "SUN4V-8001-9D.description" 676msgstr "The number of floating register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 677msgid "SUN4V-8001-9D.response" 678msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 679msgid "SUN4V-8001-9D.impact" 680msgstr "System performance may be affected. \n" 681msgid "SUN4V-8001-9D.action" 682msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 683# 684# code: SUN4V-8001-AY 685# keys: fault.cpu.ultraSPARC-T2plus.misc_reg 686# 687msgid "SUN4V-8001-AY.type" 688msgstr "Fault" 689msgid "SUN4V-8001-AY.severity" 690msgstr "Minor" 691msgid "SUN4V-8001-AY.description" 692msgstr "The number of ancillary register errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 693msgid "SUN4V-8001-AY.response" 694msgstr "The fault manager will attempt to remove the affected thread\nfrom service.\n" 695msgid "SUN4V-8001-AY.impact" 696msgstr "System performance may be affected. \n" 697msgid "SUN4V-8001-AY.action" 698msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 699# 700# code: SUN4V-8001-C3 701# keys: fault.cpu.ultraSPARC-T2plus.itlb 702# 703msgid "SUN4V-8001-C3.type" 704msgstr "Fault" 705msgid "SUN4V-8001-C3.severity" 706msgstr "Major" 707msgid "SUN4V-8001-C3.description" 708msgstr "The number of ITLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 709msgid "SUN4V-8001-C3.response" 710msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 711msgid "SUN4V-8001-C3.impact" 712msgstr "System performance is likely to be affected. \n" 713msgid "SUN4V-8001-C3.action" 714msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 715# 716# code: SUN4V-8001-DS 717# keys: fault.cpu.ultraSPARC-T2plus.dtlb 718# 719msgid "SUN4V-8001-DS.type" 720msgstr "Fault" 721msgid "SUN4V-8001-DS.severity" 722msgstr "Major" 723msgid "SUN4V-8001-DS.description" 724msgstr "The number of DTLB errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 725msgid "SUN4V-8001-DS.response" 726msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 727msgid "SUN4V-8001-DS.impact" 728msgstr "System performance is likely to be affected. \n" 729msgid "SUN4V-8001-DS.action" 730msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 731# 732# code: SUN4V-8001-E5 733# keys: fault.cpu.ultraSPARC-T2plus.icache 734# 735msgid "SUN4V-8001-E5.type" 736msgstr "Fault" 737msgid "SUN4V-8001-E5.severity" 738msgstr "Major" 739msgid "SUN4V-8001-E5.description" 740msgstr "The number of I-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 741msgid "SUN4V-8001-E5.response" 742msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 743msgid "SUN4V-8001-E5.impact" 744msgstr "System performance is likely to be affected. \n" 745msgid "SUN4V-8001-E5.action" 746msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 747# 748# code: SUN4V-8001-FP 749# keys: fault.cpu.ultraSPARC-T2plus.dcache 750# 751msgid "SUN4V-8001-FP.type" 752msgstr "Fault" 753msgid "SUN4V-8001-FP.severity" 754msgstr "Major" 755msgid "SUN4V-8001-FP.description" 756msgstr "The number of D-cache errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 757msgid "SUN4V-8001-FP.response" 758msgstr "The fault manager will attempt to remove all threads associated with\nthis resource from service.\n" 759msgid "SUN4V-8001-FP.impact" 760msgstr "System performance is likely to be affected. \n" 761msgid "SUN4V-8001-FP.action" 762msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 763# 764# code: SUN4V-8001-GA 765# keys: fault.cpu.ultraSPARC-T2plus.mau 766# 767msgid "SUN4V-8001-GA.type" 768msgstr "Fault" 769msgid "SUN4V-8001-GA.severity" 770msgstr "Major" 771msgid "SUN4V-8001-GA.description" 772msgstr "The number of modular arithmetic unit errors associated with this thread has exceeded acceptable levels.\n Refer to %s for more information." 773msgid "SUN4V-8001-GA.response" 774msgstr "Cryptographic software will not use this modular arithmetic unit.\n\n" 775msgid "SUN4V-8001-GA.impact" 776msgstr "System performance is likely to be affected. \n" 777msgid "SUN4V-8001-GA.action" 778msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 779# 780# code: SUN4V-8001-HJ 781# keys: fault.cpu.ultraSPARC-T2plus.l2data-c 782# 783msgid "SUN4V-8001-HJ.type" 784msgstr "Fault" 785msgid "SUN4V-8001-HJ.severity" 786msgstr "Critical" 787msgid "SUN4V-8001-HJ.description" 788msgstr "The number of level 2 cache correctable data errors has exceeded acceptable levels.\n Refer to %s for more information." 789msgid "SUN4V-8001-HJ.response" 790msgstr "No automated response.\n" 791msgid "SUN4V-8001-HJ.impact" 792msgstr "System performance is likely to be affected. \n" 793msgid "SUN4V-8001-HJ.action" 794msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 795# 796# code: SUN4V-8001-JE 797# keys: fault.cpu.ultraSPARC-T2plus.l2cachetag 798# 799msgid "SUN4V-8001-JE.type" 800msgstr "Fault" 801msgid "SUN4V-8001-JE.severity" 802msgstr "Critical" 803msgid "SUN4V-8001-JE.description" 804msgstr "The number of level 2 cache tag errors has exceeded acceptable levels.\n Refer to %s for more information." 805msgid "SUN4V-8001-JE.response" 806msgstr "No automated response.\n" 807msgid "SUN4V-8001-JE.impact" 808msgstr "System performance is likely to be affected. \n" 809msgid "SUN4V-8001-JE.action" 810msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 811# 812# code: SUN4V-8001-KX 813# keys: fault.cpu.ultraSPARC-T2plus.l2cachectl 814# 815msgid "SUN4V-8001-KX.type" 816msgstr "Fault" 817msgid "SUN4V-8001-KX.severity" 818msgstr "Critical" 819msgid "SUN4V-8001-KX.description" 820msgstr "The number of level 2 cache control errors has exceeded acceptable levels.\n Refer to %s for more information." 821msgid "SUN4V-8001-KX.response" 822msgstr "No automated response.\n" 823msgid "SUN4V-8001-KX.impact" 824msgstr "System performance is likely to be affected. System may be unstable.\n" 825msgid "SUN4V-8001-KX.action" 826msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 827# 828# code: SUN4V-8001-L2 829# keys: fault.cpu.ultraSPARC-T2plus.l2data-u 830# 831msgid "SUN4V-8001-L2.type" 832msgstr "Fault" 833msgid "SUN4V-8001-L2.severity" 834msgstr "Critical" 835msgid "SUN4V-8001-L2.description" 836msgstr "The number of level 2 cache uncorrectable data errors has exceeded acceptable levels.\n Refer to %s for more information." 837msgid "SUN4V-8001-L2.response" 838msgstr "No automated response.\n" 839msgid "SUN4V-8001-L2.impact" 840msgstr "System performance is likely to be affected. \n" 841msgid "SUN4V-8001-L2.action" 842msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 843# 844# code: SUN4V-8001-MR 845# keys: fault.cpu.ultraSPARC-T2plus.lfu-f 846# 847msgid "SUN4V-8001-MR.type" 848msgstr "Fault" 849msgid "SUN4V-8001-MR.severity" 850msgstr "Major" 851msgid "SUN4V-8001-MR.description" 852msgstr "A CPU chip's Link Framing Unit has stopped using a bad lane.\n Refer to %s for more information." 853msgid "SUN4V-8001-MR.response" 854msgstr "No other automated response.\n" 855msgid "SUN4V-8001-MR.impact" 856msgstr "The system's capacity to correct transmission errors between CPU chips has been reduced.\n" 857msgid "SUN4V-8001-MR.action" 858msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 859# 860# code: SUN4V-8001-N4 861# keys: fault.cpu.ultraSPARC-T2plus.lfu-p 862# 863msgid "SUN4V-8001-N4.type" 864msgstr "Fault" 865msgid "SUN4V-8001-N4.severity" 866msgstr "Major" 867msgid "SUN4V-8001-N4.description" 868msgstr "A CPU chip's Link Framing Unit has encountered a protocol error.\n Refer to %s for more information." 869msgid "SUN4V-8001-N4.response" 870msgstr "No automated response.\n" 871msgid "SUN4V-8001-N4.impact" 872msgstr "The system has most likely taken a fatal reset.\n" 873msgid "SUN4V-8001-N4.action" 874msgstr "Schedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 875# 876# code: SUN4V-8001-PQ 877# keys: fault.cpu.ultraSPARC-T2plus.lfu-u 878# 879msgid "SUN4V-8001-PQ.type" 880msgstr "Fault" 881msgid "SUN4V-8001-PQ.severity" 882msgstr "Major" 883msgid "SUN4V-8001-PQ.description" 884msgstr "A CPU chip's Link Framing Unit has encountered an unrecoverable lane failure.\n Refer to %s for more information." 885msgid "SUN4V-8001-PQ.response" 886msgstr "No automated response.\n" 887msgid "SUN4V-8001-PQ.impact" 888msgstr "The system's integrity is seriously compromised.\n" 889msgid "SUN4V-8001-PQ.action" 890msgstr "Do not rely on this system for mission-critical tasks.\nSchedule a repair procedure to replace the affected resource, the identity of which can be determined using fmdump -v -u <EVENT_ID>.\n" 891# 892# code: SUN4V-8001-QC 893# keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-u 894# 895msgid "SUN4V-8001-QC.type" 896msgstr "Fault" 897msgid "SUN4V-8001-QC.severity" 898msgstr "Critical" 899msgid "SUN4V-8001-QC.description" 900msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected a fatal\ninternal problem.\n Refer to %s for more information." 901msgid "SUN4V-8001-QC.response" 902msgstr "No automated reponse.\n" 903msgid "SUN4V-8001-QC.impact" 904msgstr "The system's integrity is compromised.\n" 905msgid "SUN4V-8001-QC.action" 906msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 907# 908# code: SUN4V-8001-R3 909# keys: fault.asic.ultraSPARC-T2plus.interconnect.opu-c 910# 911msgid "SUN4V-8001-R3.type" 912msgstr "Fault" 913msgid "SUN4V-8001-R3.severity" 914msgstr "Major" 915msgid "SUN4V-8001-R3.description" 916msgstr "The ultraSPARC-T2plus Coherency Interconnect has detected an internal problem.\n Refer to %s for more information." 917msgid "SUN4V-8001-R3.response" 918msgstr "No automated reponse.\n" 919msgid "SUN4V-8001-R3.impact" 920msgstr "The system's integrity is compromised.\n" 921msgid "SUN4V-8001-R3.action" 922msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 923# 924# code: SUN4V-8001-SY 925# keys: fault.cpu.ultraSPARC-T2plus.chip 926# 927msgid "SUN4V-8001-SY.type" 928msgstr "Fault" 929msgid "SUN4V-8001-SY.severity" 930msgstr "Critical" 931msgid "SUN4V-8001-SY.description" 932msgstr "An ultraSPARC-T2plus Interconnect has detected a fatal communication\nproblem with a CPU.\n Refer to %s for more information." 933msgid "SUN4V-8001-SY.response" 934msgstr "No automated reponse.\n" 935msgid "SUN4V-8001-SY.impact" 936msgstr "The system's integrity is seriously compromised.\n" 937msgid "SUN4V-8001-SY.action" 938msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 939# 940# code: SUN4V-8001-TD 941# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-c fault.cpu.ultraSPARC-T2plus.chip 942# 943msgid "SUN4V-8001-TD.type" 944msgstr "Fault" 945msgid "SUN4V-8001-TD.severity" 946msgstr "Minor" 947msgid "SUN4V-8001-TD.description" 948msgstr "The number of CRC errors between an ultraSPARC-T2plus\nCoherency Interconnect and a CPU has exceeded acceptable levels.\n Refer to %s for more information." 949msgid "SUN4V-8001-TD.response" 950msgstr "No automated reponse.\n" 951msgid "SUN4V-8001-TD.impact" 952msgstr "The system's integrity is seriously compromised.\n" 953msgid "SUN4V-8001-TD.action" 954msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 955# 956# code: SUN4V-8001-UH 957# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-f fault.cpu.ultraSPARC-T2plus.chip 958# 959msgid "SUN4V-8001-UH.type" 960msgstr "Fault" 961msgid "SUN4V-8001-UH.severity" 962msgstr "Major" 963msgid "SUN4V-8001-UH.description" 964msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a single-lane\nfailure communicating with a CPU.\n Refer to %s for more information." 965msgid "SUN4V-8001-UH.response" 966msgstr "No automated reponse.\n" 967msgid "SUN4V-8001-UH.impact" 968msgstr "The system's performance may be impacted.\n" 969msgid "SUN4V-8001-UH.action" 970msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 971# 972# code: SUN4V-8001-VA 973# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u fault.cpu.ultraSPARC-T2plus.chip 974# 975msgid "SUN4V-8001-VA.type" 976msgstr "Fault" 977msgid "SUN4V-8001-VA.severity" 978msgstr "Critical" 979msgid "SUN4V-8001-VA.description" 980msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal\nfault commnicating with a CPU.\n Refer to %s for more information." 981msgid "SUN4V-8001-VA.response" 982msgstr "No automated reponse.\n" 983msgid "SUN4V-8001-VA.impact" 984msgstr "The system's integrity is seriously compromised.\n" 985msgid "SUN4V-8001-VA.action" 986msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 987# 988# code: SUN4V-8001-WP 989# keys: fault.asic.ultraSPARC-T2plus.interconnect.lfu-u 990# 991msgid "SUN4V-8001-WP.type" 992msgstr "Fault" 993msgid "SUN4V-8001-WP.severity" 994msgstr "Critical" 995msgid "SUN4V-8001-WP.description" 996msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal internal\nfault and has automatically reset.\n Refer to %s for more information." 997msgid "SUN4V-8001-WP.response" 998msgstr "No automated reponse.\n" 999msgid "SUN4V-8001-WP.impact" 1000msgstr "The system's integrity is seriously compromised.\n" 1001msgid "SUN4V-8001-WP.action" 1002msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 1003# 1004# code: SUN4V-8001-X5 1005# keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-u fault.cpu.ultraSPARC-T2plus.chip 1006# 1007msgid "SUN4V-8001-X5.type" 1008msgstr "Fault" 1009msgid "SUN4V-8001-X5.severity" 1010msgstr "Critical" 1011msgid "SUN4V-8001-X5.description" 1012msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal communication\nfault with a CPU.\n Refer to %s for more information." 1013msgid "SUN4V-8001-X5.response" 1014msgstr "No automated reponse.\n" 1015msgid "SUN4V-8001-X5.impact" 1016msgstr "The system's performance may be compromised.\n" 1017msgid "SUN4V-8001-X5.action" 1018msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 1019# 1020# code: SUN4V-8001-YS 1021# keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c fault.cpu.ultraSPARC-T2plus.chip 1022# 1023msgid "SUN4V-8001-YS.type" 1024msgstr "Fault" 1025msgid "SUN4V-8001-YS.severity" 1026msgstr "Major" 1027msgid "SUN4V-8001-YS.description" 1028msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fault\ncommunicating with a CPU.\n Refer to %s for more information." 1029msgid "SUN4V-8001-YS.response" 1030msgstr "No automated reponse.\n" 1031msgid "SUN4V-8001-YS.impact" 1032msgstr "The system's integrity may be seriously compromised.\n" 1033msgid "SUN4V-8001-YS.action" 1034msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 1035# 1036# code: SUN4V-8002-0C 1037# keys: fault.asic.ultraSPARC-T2plus.interconnect.gpd-c 1038# 1039msgid "SUN4V-8002-0C.type" 1040msgstr "Fault" 1041msgid "SUN4V-8002-0C.severity" 1042msgstr "Major" 1043msgid "SUN4V-8002-0C.description" 1044msgstr "The ultraSPARC-T2plus Interconnect has detected a fault communicating\nwith the service processor.\n Refer to %s for more information." 1045msgid "SUN4V-8002-0C.response" 1046msgstr "No automated reponse.\n" 1047msgid "SUN4V-8002-0C.impact" 1048msgstr "The system's performance may be impacted.\n" 1049msgid "SUN4V-8002-0C.action" 1050msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 1051# 1052# code: SUN4V-8002-1Q 1053# keys: fault.asic.fpga fault.asic.ultraSPARC-T2plus.interconnect.gpd-c 1054# 1055msgid "SUN4V-8002-1Q.type" 1056msgstr "Fault" 1057msgid "SUN4V-8002-1Q.severity" 1058msgstr "Major" 1059msgid "SUN4V-8002-1Q.description" 1060msgstr "ultraSPARC-T2plus Coherency Interconnect detected a fault on the LPC bus.\n Refer to %s for more information." 1061msgid "SUN4V-8002-1Q.response" 1062msgstr "No automated reponse.\n" 1063msgid "SUN4V-8002-1Q.impact" 1064msgstr "The system's performance may be impacted.\n" 1065msgid "SUN4V-8002-1Q.action" 1066msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 1067# 1068# code: SUN4V-8002-24 1069# keys: fault.asic.ultraSPARC-T2plus.interconnect.asu 1070# 1071msgid "SUN4V-8002-24.type" 1072msgstr "Fault" 1073msgid "SUN4V-8002-24.severity" 1074msgstr "Critical" 1075msgid "SUN4V-8002-24.description" 1076msgstr "An ultraSPARC-T2plus Coherency Interconnect has detected a fatal fault.\n Refer to %s for more information." 1077msgid "SUN4V-8002-24.response" 1078msgstr "No automated reponse.\n" 1079msgid "SUN4V-8002-24.impact" 1080msgstr "The system's integrity is seriously compromised.\n" 1081msgid "SUN4V-8002-24.action" 1082msgstr "Schedule a repair procedure to replace the affected component, the identity\nof which can be determined by using fmdump -v -u <EVENT_ID>.\n" 1083# 1084# code: SUN4V-8002-3R 1085# keys: fault.memory.dimm-page-retires-excessive 1086# 1087msgid "SUN4V-8002-3R.type" 1088msgstr "Fault" 1089msgid "SUN4V-8002-3R.severity" 1090msgstr "Major" 1091msgid "SUN4V-8002-3R.description" 1092msgstr "The number of correctable errors associated with this memory module has exceeded acceptable levels.\n Refer to %s for more information." 1093msgid "SUN4V-8002-3R.response" 1094msgstr "Pages of memory associated with this memory module have been removed from service, up to a limit which has now been reached.\n" 1095msgid "SUN4V-8002-3R.impact" 1096msgstr "Total system memory capacity has been reduced.\n" 1097msgid "SUN4V-8002-3R.action" 1098msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n" 1099# 1100# code: SUN4V-8002-42 1101# keys: fault.memory.dimm-ue-imminent 1102# 1103msgid "SUN4V-8002-42.type" 1104msgstr "Fault" 1105msgid "SUN4V-8002-42.severity" 1106msgstr "Critical" 1107msgid "SUN4V-8002-42.description" 1108msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n Refer to %s for more information." 1109msgid "SUN4V-8002-42.response" 1110msgstr "None at this time.\n" 1111msgid "SUN4V-8002-42.impact" 1112msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n" 1113msgid "SUN4V-8002-42.action" 1114msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n" 1115# 1116# code: SUN4V-8002-5X 1117# keys: fault.memory.dram-ue-imminent 1118# 1119msgid "SUN4V-8002-5X.type" 1120msgstr "Fault" 1121msgid "SUN4V-8002-5X.severity" 1122msgstr "Critical" 1123msgid "SUN4V-8002-5X.description" 1124msgstr "A pattern of correctable errors has been observed suggesting the potential exists that an uncorrectable error may occur.\n Refer to %s for more information." 1125msgid "SUN4V-8002-5X.response" 1126msgstr "None at this time.\n" 1127msgid "SUN4V-8002-5X.impact" 1128msgstr "None at this time. However, the potential uncorrectable error warrants proactive service action to avoid any unplanned system outages.\n" 1129msgid "SUN4V-8002-5X.action" 1130msgstr "Schedule a repair procedure to replace the DIMM. Use fmadm faulty to identify the DIMM to replace.\n" 1131