xref: /illumos-gate/usr/src/man/man1/kill.1 (revision b49b27dcb66b2c7f4a23f7bc158e2dde5cd79030)
te
Copyright (c) 2007, Sun Microsystems, Inc. All Rights Reserved
Copyright 1989 AT&T
Portions Copyright (c) 1982-2007 AT&T Knowledge Ventures
Portions Copyright (c) 1992, X/Open Company Limited All Rights Reserved
Sun Microsystems, Inc. gratefully acknowledges The Open Group for permission to reproduce portions of its copyrighted documentation. Original documentation from The Open Group can be obtained online at http://www.opengroup.org/bookstore/.
The Institute of Electrical and Electronics Engineers and The Open Group, have given us permission to reprint portions of their documentation. In the following statement, the phrase "this text" refers to portions of the system documentation. Portions of this text
are reprinted and reproduced in electronic form in the Sun OS Reference Manual, from IEEE Std 1003.1, 2004 Edition, Standard for Information Technology -- Portable Operating System Interface (POSIX), The Open Group Base Specifications Issue 6, Copyright (C) 2001-2004 by the Institute of Electrical
and Electronics Engineers, Inc and The Open Group. In the event of any discrepancy between these versions and the original IEEE and The Open Group Standard, the original IEEE and The Open Group Standard is the referee document. The original Standard can be obtained online at http://www.opengroup.org/unix/online.html.
This notice shall appear on any product containing this material.
The contents of this file are subject to the terms of the Common Development and Distribution License (the "License"). You may not use this file except in compliance with the License. You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE or http://www.opensolaris.org/os/licensing.
See the License for the specific language governing permissions and limitations under the License. When distributing Covered Code, include this CDDL HEADER in each file and include the License file at usr/src/OPENSOLARIS.LICENSE. If applicable, add the following below this CDDL HEADER, with
the fields enclosed by brackets "[]" replaced with your own identifying information: Portions Copyright [yyyy] [name of copyright owner]
KILL 1 "Aug 11, 2009"
NAME
kill - terminate or signal processes
SYNOPSIS

/usr/bin/kill -s signal_name pid...

/usr/bin/kill -l [exit_status]

/usr/bin/kill [-signal_name] pid...

/usr/bin/kill [-signal_number] pid...
DESCRIPTION

The kill utility sends a signal to the process or processes specified by each pid operand.

For each pid operand, the kill utility performs actions equivalent to the kill(2) function called with the following arguments:

1. The value of the pid operand is used as the pid argument.

2. The sig argument is the value specified by the -s option, the -signal_name option, or the -signal_number option, or, if none of these options is specified, by SIGTERM.

The signaled process must belong to the current user unless the user is the super-user.

See NOTES for descriptions of the shell built-in versions of kill.

OPTIONS

The following options are supported: -l

(The letter ell.) Writes all values of signal_name supported by the implementation, if no operand is specified. If an exit_status operand is specified and it is a value of the ? shell special parameter and wait corresponding to a process that was terminated by a signal, the signal_name corresponding to the signal that terminated the process is written. If an exit_status operand is specified and it is the unsigned decimal integer value of a signal number, the signal_name corresponding to that signal is written. Otherwise, the results are unspecified.

-s signal_name

Specifies the signal to send, using one of the symbolic names defined in the <signal.h> description. Values of signal_name is recognized in a case-independent fashion, without the SIG prefix. In addition, the symbolic name 0 is recognized, representing the signal value zero. The corresponding signal is sent instead of SIGTERM.

-signal_name

Equivalent to -s signal_name.

-signal_number

Specifies a non-negative decimal integer, signal_number, representing the signal to be used instead of SIGTERM, as the sig argument in the effective call to kill(2).

OPERANDS

The following operands are supported: pid

One of the following:

1. A decimal integer specifying a process or process group to be signaled. The process or processes selected by positive, negative and zero values of the pid operand is as described for the kill function. If process number 0 is specified, all processes in the process group are signaled. If the first pid operand is negative, it should be preceded by -- to keep it from being interpreted as an option.

2. A job control job ID that identifies a background process group to be signaled. The job control job ID notation is applicable only for invocations of kill in the current shell execution environment.

The job control job ID type of pid is available only on systems supporting the job control option.
exit_status

A decimal integer specifying a signal number or the exit status of a process terminated by a signal.

USAGE

Process numbers can be found by using ps(1).

The job control job ID notation is not required to work as expected when kill is operating in its own utility execution environment. In either of the following examples:

example% nohup kill %1 &
example% system( "kill %1");

kill operates in a different environment and does not share the shell's understanding of job numbers.

OUTPUT

When the -l option is not specified, the standard output is not be used.

When the -l option is specified, the symbolic name of each signal is written in the following format:

"%s%c", <signal_name>, <separator>

where the <signal_name> is in upper-case, without the SIG prefix, and the <separator> is either a newline character or a space character. For the last signal written, <separator> is a newline character.

When both the -l option and exit_status operand are specified, the symbolic name of the corresponding signal is written in the following format:

"%s\en", <signal_name>
EXAMPLES

Example 1 Sending the kill signal

Any of the commands:

example% kill -9 100 -165
example% kill -s kill 100 -165
example% kill -s KILL 100 -165

sends the SIGKILL signal to the process whose process ID is 100 and to all processes whose process group ID is 165, assuming the sending process has permission to send that signal to the specified processes, and that they exist.

Example 2 Avoiding ambiguity with an initial negative number

To avoid an ambiguity of an initial negative number argument specifying either a signal number or a process group, the former is always be the case. Therefore, to send the default signal to a process group (for example, 123), an application should use a command similar to one of the following:

example% kill -TERM -123
example% kill -- -123
ENVIRONMENT VARIABLES

See environ(5) for descriptions of the following environment variables that affect the execution of kill: LANG, LC_ALL, LC_CTYPE, LC_MESSAGES, and NLSPATH.

EXIT STATUS

The following exit values are returned: 0

At least one matching process was found for each pid operand, and the specified signal was successfully processed for at least one matching process.

>0

An error occurred.

ATTRIBUTES

See attributes(5) for descriptions of the following attributes:

"/usr/bin/kill, csh, ksh, sh"
ATTRIBUTE TYPE ATTRIBUTE VALUE
CSI Enabled
Interface Stability Committed
Standard See standards(5).
"ksh93"
ATTRIBUTE TYPE ATTRIBUTE VALUE
CSI Enabled
Interface Stability Uncommitted
SEE ALSO

csh(1), getconf(1), jobs(1), ksh(1), ksh93(1), ps(1), sh(1), shell_builtins(1), wait(1), kill(2), signal(3C), signal.h(3HEAD), attributes(5), environ(5), standards(5)

NOTES

The number of realtime signals supported is defined by the getconf(1) value _POSIX_RTSIG_MAX.

"sh"

The Bourne shell, sh, has a built-in version of kill to provide the functionality of the kill command for processes identified with a jobid. The sh syntax is:

kill [ -sig ] [ pid ] [ %job ]...
kill -l
"csh"

The C-shell, csh, also has a built-in kill command, whose syntax is:

kill [-sig][pid][%job]...
kill -l

The csh kill built-in sends the TERM (terminate) signal, by default, or the signal specified, to the specified process ID, the job indicated, or the current job. Signals are either specified by number or by name. There is no default. Typing kill does not send a signal to the current job. If the signal being sent is TERM (terminate) or HUP (hangup), then the job or process is sent a CONT (continue) signal as well. -l

Lists the signal names that can be sent.

"ksh"

The syntax of the ksh kill is:

kill [-sig][pid][%job]...
kill -l

The ksh kill sends either the TERM (terminate) signal or the specified signal to the specified jobs or processes. Signals are either specified by number or by names (as specified in signal.h(3HEAD) stripped of the SIG prefix). If the signal being sent is TERM (terminate) or HUP (hangup), then the job or process is sent a CONT (continue) signal if it is stopped. The argument job can be the process id of a process that is not a member of one of the active jobs. In the second form, kill -l, the signal numbers and names are listed.

"ksh93"

The syntax of the ksh93 kill is:

kill [-n signum] [-s signame] job ...
kill [-n signum] [-s signame] -l [arg ...]

With the first form in which -l is not specified, kill sends a signal to one or more processes specified by job. This normally terminates the processes unless the signal is being caught or ignored.

Specify job as one of the following: number

The process id of job.

-number

The process group id of job.

%number

The job number.

%string

The job whose name begins with string.

%?string

The job whose name contains string.

%+

%%

The current job.

%-

The previous job.

If the signal is not specified with either the -n or the -s option, the SIGTERM signal is used.

If -l is specified, and no arg is specified, then kill writes the list of signals to standard output. Otherwise, arg can be either a signal name, or a number representing either a signal number or exit status for a process that was terminated due to a signal. If a name is specified the corresponding signal number is written to standard output. If a number is specified the corresponding signal name is written to standard output. -l

List signal names or signal numbers rather than sending signals as described above. The -n and -s options cannot be specified.

-n signum

Specify a signal number to send. Signal numbers are not portable across platforms, except for the following: 0

No signal.

1

HUP

2

INT

3

QUIT

6

ABRT

9

KILL

14

ALRM

15

TERM

-s signame

Specify a signal name to send. The signal names are derived from their names in <signal.h> without the SIG prefix and are case insensitive. kill -l generates the list of signals on the current platform.

kill in ksh93 exits with one of the following values: 0

At least one matching process was found for each job operand, and the specified signal was successfully sent to at least one matching process.

>0

An error occurred.