xref: /illumos-gate/usr/src/cmd/fm/dicts/INTEL.po (revision 92a0208178405fef708b0283ffcaa02fbc3468ff)
1#
2# Copyright 2008 Sun Microsystems, Inc.  All rights reserved.
3# Use is subject to license terms.
4#
5# CDDL HEADER START
6#
7# The contents of this file are subject to the terms of the
8# Common Development and Distribution License (the "License").
9# You may not use this file except in compliance with the License.
10#
11# You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
12# or http://www.opensolaris.org/os/licensing.
13# See the License for the specific language governing permissions
14# and limitations under the License.
15#
16# When distributing Covered Code, include this CDDL HEADER in each
17# file and include the License file at usr/src/OPENSOLARIS.LICENSE.
18# If applicable, add the following below this CDDL HEADER, with the
19# fields enclosed by brackets "[]" replaced with your own identifying
20# information: Portions Copyright [yyyy] [name of copyright owner]
21#
22# CDDL HEADER END
23#
24# DO NOT EDIT -- this file is generated by the Event Registry.
25#
26#
27# code: INTEL-8000-1J
28# keys: fault.cpu.intel.internal
29#
30msgid "INTEL-8000-1J.type"
31msgstr "Fault"
32msgid "INTEL-8000-1J.severity"
33msgstr "Major"
34msgid "INTEL-8000-1J.description"
35msgstr "An internal error has been encountered on this cpu.  Refer to %s for more information."
36msgid "INTEL-8000-1J.response"
37msgstr "The system will attempt to offline this cpu to remove it from service."
38msgid "INTEL-8000-1J.impact"
39msgstr "Performance of this system may be affected."
40msgid "INTEL-8000-1J.action"
41msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
42#
43# code: INTEL-8000-22
44# keys: fault.cpu.intel.l0cache
45#
46msgid "INTEL-8000-22.type"
47msgstr "Fault"
48msgid "INTEL-8000-22.severity"
49msgstr "Major"
50msgid "INTEL-8000-22.description"
51msgstr "A level 0 cache on this cpu is faulty.  Refer to %s for more information."
52msgid "INTEL-8000-22.response"
53msgstr "The system will attempt to offline this cpu to remove it from service."
54msgid "INTEL-8000-22.impact"
55msgstr "Performance of this system may be affected."
56msgid "INTEL-8000-22.action"
57msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
58#
59# code: INTEL-8000-3X
60# keys: fault.cpu.intel.l1cache
61#
62msgid "INTEL-8000-3X.type"
63msgstr "Fault"
64msgid "INTEL-8000-3X.severity"
65msgstr "Major"
66msgid "INTEL-8000-3X.description"
67msgstr "A level 1 cache on this cpu is faulty.  Refer to %s for more information."
68msgid "INTEL-8000-3X.response"
69msgstr "The system will attempt to offline this cpu to remove it from service."
70msgid "INTEL-8000-3X.impact"
71msgstr "Performance of this system may be affected."
72msgid "INTEL-8000-3X.action"
73msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
74#
75# code: INTEL-8000-44
76# keys: fault.cpu.intel.l2cache
77#
78msgid "INTEL-8000-44.type"
79msgstr "Fault"
80msgid "INTEL-8000-44.severity"
81msgstr "Major"
82msgid "INTEL-8000-44.description"
83msgstr "A level 2 cache on this cpu is faulty.  Refer to %s for more information."
84msgid "INTEL-8000-44.response"
85msgstr "The system will attempt to offline this cpu to remove it from service."
86msgid "INTEL-8000-44.impact"
87msgstr "Performance of this system may be affected."
88msgid "INTEL-8000-44.action"
89msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
90#
91# code: INTEL-8000-5R
92# keys: fault.cpu.intel.cache
93#
94msgid "INTEL-8000-5R.type"
95msgstr "Fault"
96msgid "INTEL-8000-5R.severity"
97msgstr "Major"
98msgid "INTEL-8000-5R.description"
99msgstr "A cache on this cpu is faulty.  Refer to %s for more information."
100msgid "INTEL-8000-5R.response"
101msgstr "The system will attempt to offline this cpu to remove it from service."
102msgid "INTEL-8000-5R.impact"
103msgstr "Performance of this system may be affected."
104msgid "INTEL-8000-5R.action"
105msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
106#
107# code: INTEL-8000-6C
108# keys: fault.cpu.intel.l0dtlb
109#
110msgid "INTEL-8000-6C.type"
111msgstr "Fault"
112msgid "INTEL-8000-6C.severity"
113msgstr "Major"
114msgid "INTEL-8000-6C.description"
115msgstr "A level 0 Data TLB on this cpu is faulty.  Refer to %s for more information."
116msgid "INTEL-8000-6C.response"
117msgstr "The system will attempt to offline this cpu to remove it from service."
118msgid "INTEL-8000-6C.impact"
119msgstr "Performance of this system may be affected."
120msgid "INTEL-8000-6C.action"
121msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
122#
123# code: INTEL-8000-7Q
124# keys: fault.cpu.intel.l1dtlb
125#
126msgid "INTEL-8000-7Q.type"
127msgstr "Fault"
128msgid "INTEL-8000-7Q.severity"
129msgstr "Major"
130msgid "INTEL-8000-7Q.description"
131msgstr "A level 1 Data TLB on this cpu is faulty.  Refer to %s for more information."
132msgid "INTEL-8000-7Q.response"
133msgstr "The system will attempt to offline this cpu to remove it from service."
134msgid "INTEL-8000-7Q.impact"
135msgstr "Performance of this system may be affected."
136msgid "INTEL-8000-7Q.action"
137msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
138#
139# code: INTEL-8000-8Y
140# keys: fault.cpu.intel.l2dtlb
141#
142msgid "INTEL-8000-8Y.type"
143msgstr "Fault"
144msgid "INTEL-8000-8Y.severity"
145msgstr "Major"
146msgid "INTEL-8000-8Y.description"
147msgstr "A level 2 Data TLB on this cpu is faulty.  Refer to %s for more information."
148msgid "INTEL-8000-8Y.response"
149msgstr "The system will attempt to offline this cpu to remove it from service."
150msgid "INTEL-8000-8Y.impact"
151msgstr "Performance of this system may be affected."
152msgid "INTEL-8000-8Y.action"
153msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
154#
155# code: INTEL-8000-93
156# keys: fault.cpu.intel.dtlb
157#
158msgid "INTEL-8000-93.type"
159msgstr "Fault"
160msgid "INTEL-8000-93.severity"
161msgstr "Major"
162msgid "INTEL-8000-93.description"
163msgstr "A Data TLB on this cpu is faulty.  Refer to %s for more information."
164msgid "INTEL-8000-93.response"
165msgstr "The system will attempt to offline this cpu to remove it from service."
166msgid "INTEL-8000-93.impact"
167msgstr "Performance of this system may be affected."
168msgid "INTEL-8000-93.action"
169msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
170#
171# code: INTEL-8000-AH
172# keys: fault.cpu.intel.l0itlb
173#
174msgid "INTEL-8000-AH.type"
175msgstr "Fault"
176msgid "INTEL-8000-AH.severity"
177msgstr "Major"
178msgid "INTEL-8000-AH.description"
179msgstr "A level 0 Instruction TLB on this cpu is faulty.  Refer to %s for more information."
180msgid "INTEL-8000-AH.response"
181msgstr "The system will attempt to offline this cpu to remove it from service."
182msgid "INTEL-8000-AH.impact"
183msgstr "Performance of this system may be affected."
184msgid "INTEL-8000-AH.action"
185msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
186#
187# code: INTEL-8000-CD
188# keys: fault.cpu.intel.l1itlb
189#
190msgid "INTEL-8000-CD.type"
191msgstr "Fault"
192msgid "INTEL-8000-CD.severity"
193msgstr "Major"
194msgid "INTEL-8000-CD.description"
195msgstr "A level 1 Instruction TLB on this cpu is faulty.  Refer to %s for more information."
196msgid "INTEL-8000-CD.response"
197msgstr "The system will attempt to offline this cpu to remove it from service."
198msgid "INTEL-8000-CD.impact"
199msgstr "Performance of this system may be affected."
200msgid "INTEL-8000-CD.action"
201msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
202#
203# code: INTEL-8000-DP
204# keys: fault.cpu.intel.l2itlb
205#
206msgid "INTEL-8000-DP.type"
207msgstr "Fault"
208msgid "INTEL-8000-DP.severity"
209msgstr "Major"
210msgid "INTEL-8000-DP.description"
211msgstr "A level 2 Instruction TLB on this cpu is faulty.  Refer to %s for more information."
212msgid "INTEL-8000-DP.response"
213msgstr "The system will attempt to offline this cpu to remove it from service."
214msgid "INTEL-8000-DP.impact"
215msgstr "Performance of this system may be affected."
216msgid "INTEL-8000-DP.action"
217msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
218#
219# code: INTEL-8000-EA
220# keys: fault.cpu.intel.itlb
221#
222msgid "INTEL-8000-EA.type"
223msgstr "Fault"
224msgid "INTEL-8000-EA.severity"
225msgstr "Major"
226msgid "INTEL-8000-EA.description"
227msgstr "An Instruction TLB on this cpu is faulty.  Refer to %s for more information."
228msgid "INTEL-8000-EA.response"
229msgstr "The system will attempt to offline this cpu to remove it from service."
230msgid "INTEL-8000-EA.impact"
231msgstr "Performance of this system may be affected."
232msgid "INTEL-8000-EA.action"
233msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
234#
235# code: INTEL-8000-FS
236# keys: fault.cpu.intel.l0tlb
237#
238msgid "INTEL-8000-FS.type"
239msgstr "Fault"
240msgid "INTEL-8000-FS.severity"
241msgstr "Major"
242msgid "INTEL-8000-FS.description"
243msgstr "A level 0 TLB on this cpu is faulty.  Refer to %s for more information."
244msgid "INTEL-8000-FS.response"
245msgstr "The system will attempt to offline this cpu to remove it from service."
246msgid "INTEL-8000-FS.impact"
247msgstr "Performance of this system may be affected."
248msgid "INTEL-8000-FS.action"
249msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
250#
251# code: INTEL-8000-G5
252# keys: fault.cpu.intel.l1tlb
253#
254msgid "INTEL-8000-G5.type"
255msgstr "Fault"
256msgid "INTEL-8000-G5.severity"
257msgstr "Major"
258msgid "INTEL-8000-G5.description"
259msgstr "A level 1 TLB on this cpu is faulty.  Refer to %s for more information."
260msgid "INTEL-8000-G5.response"
261msgstr "The system will attempt to offline this cpu to remove it from service."
262msgid "INTEL-8000-G5.impact"
263msgstr "Performance of this system may be affected."
264msgid "INTEL-8000-G5.action"
265msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
266#
267# code: INTEL-8000-HX
268# keys: fault.cpu.intel.l2tlb
269#
270msgid "INTEL-8000-HX.type"
271msgstr "Fault"
272msgid "INTEL-8000-HX.severity"
273msgstr "Major"
274msgid "INTEL-8000-HX.description"
275msgstr "A level 2 TLB on this cpu is faulty.  Refer to %s for more information."
276msgid "INTEL-8000-HX.response"
277msgstr "The system will attempt to offline this cpu to remove it from service."
278msgid "INTEL-8000-HX.impact"
279msgstr "Performance of this system may be affected."
280msgid "INTEL-8000-HX.action"
281msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
282#
283# code: INTEL-8000-J2
284# keys: fault.cpu.intel.tlb
285#
286msgid "INTEL-8000-J2.type"
287msgstr "Fault"
288msgid "INTEL-8000-J2.severity"
289msgstr "Major"
290msgid "INTEL-8000-J2.description"
291msgstr "A TLB on this cpu is faulty.  Refer to %s for more information."
292msgid "INTEL-8000-J2.response"
293msgstr "The system will attempt to offline this cpu to remove it from service."
294msgid "INTEL-8000-J2.impact"
295msgstr "Performance of this system may be affected."
296msgid "INTEL-8000-J2.action"
297msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
298#
299# code: INTEL-8000-KJ
300# keys: fault.cpu.intel.l0dcache
301#
302msgid "INTEL-8000-KJ.type"
303msgstr "Fault"
304msgid "INTEL-8000-KJ.severity"
305msgstr "Major"
306msgid "INTEL-8000-KJ.description"
307msgstr "A level 0 Data Cache on this cpu is faulty.  Refer to %s for more information."
308msgid "INTEL-8000-KJ.response"
309msgstr "The system will attempt to offline this cpu to remove it from service."
310msgid "INTEL-8000-KJ.impact"
311msgstr "Performance of this system may be affected."
312msgid "INTEL-8000-KJ.action"
313msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
314#
315# code: INTEL-8000-LE
316# keys: fault.cpu.intel.l1dcache
317#
318msgid "INTEL-8000-LE.type"
319msgstr "Fault"
320msgid "INTEL-8000-LE.severity"
321msgstr "Major"
322msgid "INTEL-8000-LE.description"
323msgstr "A level 1 Data Cache on this cpu is faulty.  Refer to %s for more information."
324msgid "INTEL-8000-LE.response"
325msgstr "The system will attempt to offline this cpu to remove it from service."
326msgid "INTEL-8000-LE.impact"
327msgstr "Performance of this system may be affected."
328msgid "INTEL-8000-LE.action"
329msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
330#
331# code: INTEL-8000-MQ
332# keys: fault.cpu.intel.l2dcache
333#
334msgid "INTEL-8000-MQ.type"
335msgstr "Fault"
336msgid "INTEL-8000-MQ.severity"
337msgstr "Major"
338msgid "INTEL-8000-MQ.description"
339msgstr "A level 2 Data Cache on this cpu is faulty.  Refer to %s for more information."
340msgid "INTEL-8000-MQ.response"
341msgstr "The system will attempt to offline this cpu to remove it from service."
342msgid "INTEL-8000-MQ.impact"
343msgstr "Performance of this system may be affected."
344msgid "INTEL-8000-MQ.action"
345msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
346#
347# code: INTEL-8000-NC
348# keys: fault.cpu.intel.dcache
349#
350msgid "INTEL-8000-NC.type"
351msgstr "Fault"
352msgid "INTEL-8000-NC.severity"
353msgstr "Major"
354msgid "INTEL-8000-NC.description"
355msgstr "A Data Cache on this cpu is faulty.  Refer to %s for more information."
356msgid "INTEL-8000-NC.response"
357msgstr "The system will attempt to offline this cpu to remove it from service."
358msgid "INTEL-8000-NC.impact"
359msgstr "Performance of this system may be affected."
360msgid "INTEL-8000-NC.action"
361msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
362#
363# code: INTEL-8000-PR
364# keys: fault.cpu.intel.l0icache
365#
366msgid "INTEL-8000-PR.type"
367msgstr "Fault"
368msgid "INTEL-8000-PR.severity"
369msgstr "Major"
370msgid "INTEL-8000-PR.description"
371msgstr "A level 0 Instruction Cache on this cpu is faulty.  Refer to %s for more information."
372msgid "INTEL-8000-PR.response"
373msgstr "The system will attempt to offline this cpu to remove it from service."
374msgid "INTEL-8000-PR.impact"
375msgstr "Performance of this system may be affected."
376msgid "INTEL-8000-PR.action"
377msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
378#
379# code: INTEL-8000-Q4
380# keys: fault.cpu.intel.l1icache
381#
382msgid "INTEL-8000-Q4.type"
383msgstr "Fault"
384msgid "INTEL-8000-Q4.severity"
385msgstr "Major"
386msgid "INTEL-8000-Q4.description"
387msgstr "A level 1 Instruction Cache on this cpu is faulty.  Refer to %s for more information."
388msgid "INTEL-8000-Q4.response"
389msgstr "The system will attempt to offline this cpu to remove it from service."
390msgid "INTEL-8000-Q4.impact"
391msgstr "Performance of this system may be affected."
392msgid "INTEL-8000-Q4.action"
393msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
394#
395# code: INTEL-8000-RD
396# keys: fault.cpu.intel.l2icache
397#
398msgid "INTEL-8000-RD.type"
399msgstr "Fault"
400msgid "INTEL-8000-RD.severity"
401msgstr "Major"
402msgid "INTEL-8000-RD.description"
403msgstr "A level 2 Instruction Cache on this cpu is faulty.  Refer to %s for more information."
404msgid "INTEL-8000-RD.response"
405msgstr "The system will attempt to offline this cpu to remove it from service."
406msgid "INTEL-8000-RD.impact"
407msgstr "Performance of this system may be affected."
408msgid "INTEL-8000-RD.action"
409msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
410#
411# code: INTEL-8000-SH
412# keys: fault.cpu.intel.icache
413#
414msgid "INTEL-8000-SH.type"
415msgstr "Fault"
416msgid "INTEL-8000-SH.severity"
417msgstr "Major"
418msgid "INTEL-8000-SH.description"
419msgstr "An Instruction Cache on this cpu is faulty.  Refer to %s for more information."
420msgid "INTEL-8000-SH.response"
421msgstr "The system will attempt to offline this cpu to remove it from service."
422msgid "INTEL-8000-SH.impact"
423msgstr "Performance of this system may be affected."
424msgid "INTEL-8000-SH.action"
425msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
426#
427# code: INTEL-8000-T3
428# keys: fault.cpu.intel.bus_interconnect
429#
430msgid "INTEL-8000-T3.type"
431msgstr "Fault"
432msgid "INTEL-8000-T3.severity"
433msgstr "Major"
434msgid "INTEL-8000-T3.description"
435msgstr "Excessive errors from a bus, memory or IO.  Refer to %s for more information."
436msgid "INTEL-8000-T3.response"
437msgstr "No automated response action is possible"
438msgid "INTEL-8000-T3.impact"
439msgstr "System may panic or be reset by BIOS"
440msgid "INTEL-8000-T3.action"
441msgstr "Schedule a repair procedure to check seating of memory dimms. Schedule a repair procedure to check seating of io cards"
442#
443# code: INTEL-8000-UY
444# keys: fault.cpu.intel.bus_interconnect_memory
445#
446msgid "INTEL-8000-UY.type"
447msgstr "Fault"
448msgid "INTEL-8000-UY.severity"
449msgstr "Major"
450msgid "INTEL-8000-UY.description"
451msgstr "Excessive errors from memory accesses.  Refer to %s for more information."
452msgid "INTEL-8000-UY.response"
453msgstr "No automated response action is possible"
454msgid "INTEL-8000-UY.impact"
455msgstr "System may panic or be reset by BIOS"
456msgid "INTEL-8000-UY.action"
457msgstr "Schedule a repair procedure to reseat or replace memory dimms"
458#
459# code: INTEL-8000-V5
460# keys: fault.cpu.intel.bus_interconnect_io
461#
462msgid "INTEL-8000-V5.type"
463msgstr "Fault"
464msgid "INTEL-8000-V5.severity"
465msgstr "Major"
466msgid "INTEL-8000-V5.description"
467msgstr "Excessive errors from IO accesses.  Refer to %s for more information."
468msgid "INTEL-8000-V5.response"
469msgstr "No automated response action is possible"
470msgid "INTEL-8000-V5.impact"
471msgstr "System may panic or be reset by BIOS"
472msgid "INTEL-8000-V5.action"
473msgstr "Schedule a repair procedure to check seating of io cards"
474#
475# code: INTEL-8000-WS
476# keys: fault.cpu.intel.nb.fsb
477#
478msgid "INTEL-8000-WS.type"
479msgstr "Fault"
480msgid "INTEL-8000-WS.severity"
481msgstr "Critical"
482msgid "INTEL-8000-WS.description"
483msgstr "Front Side bus between CPU and northbridge  Refer to %s for more information."
484msgid "INTEL-8000-WS.response"
485msgstr "System panic or reset by BIOS"
486msgid "INTEL-8000-WS.impact"
487msgstr "System may panic or be reset by BIOS"
488msgid "INTEL-8000-WS.action"
489msgstr "Schedule a repair procedure to replace the affected CPU.  Use 'fmadm faulty' to identify the module."
490#
491# code: INTEL-8000-XA
492# keys: fault.memory.intel.fbd.berr
493#
494msgid "INTEL-8000-XA.type"
495msgstr "Fault"
496msgid "INTEL-8000-XA.severity"
497msgstr "Major"
498msgid "INTEL-8000-XA.description"
499msgstr "A fault occurred on a memory dimm channel  Refer to %s for more information."
500msgid "INTEL-8000-XA.response"
501msgstr "System panic or reset by BIOS"
502msgid "INTEL-8000-XA.impact"
503msgstr "System may not boot"
504msgid "INTEL-8000-XA.action"
505msgstr "reseat or replace dimms on channel.  Use 'fmadm faulty' to identify the channel."
506#
507# code: INTEL-8000-YP
508# keys: fault.memory.intel.fbd.alert
509#
510msgid "INTEL-8000-YP.type"
511msgstr "Fault"
512msgid "INTEL-8000-YP.severity"
513msgstr "Critical"
514msgid "INTEL-8000-YP.description"
515msgstr "Memory Controller detected a corrupted acknowledgment on a retry of a non-redundant memory write or configuration write  Refer to %s for more information."
516msgid "INTEL-8000-YP.response"
517msgstr "System panic or reset by BIOS"
518msgid "INTEL-8000-YP.impact"
519msgstr "System may be unexpectedly reset"
520msgid "INTEL-8000-YP.action"
521msgstr "reseat or replace dimm.  Use 'fmadm faulty' to identify the dimm."
522#
523# code: INTEL-8001-0A
524# keys: fault.memory.intel.fbd.crc
525#
526msgid "INTEL-8001-0A.type"
527msgstr "Fault"
528msgid "INTEL-8001-0A.severity"
529msgstr "Critical"
530msgid "INTEL-8001-0A.description"
531msgstr "Memory Controller detected a corrupted CRC error on a non-redundant retry of memory or dimm configuration read.  Refer to %s for more information."
532msgid "INTEL-8001-0A.response"
533msgstr "System panic or reset by BIOS"
534msgid "INTEL-8001-0A.impact"
535msgstr "System may not boot"
536msgid "INTEL-8001-0A.action"
537msgstr "reseat or replace dimm.  Use 'fmadm faulty' to identify the dimm."
538#
539# code: INTEL-8001-1P
540# keys: fault.memory.intel.fbd.ch
541#
542msgid "INTEL-8001-1P.type"
543msgstr "Fault"
544msgid "INTEL-8001-1P.severity"
545msgstr "Major"
546msgid "INTEL-8001-1P.description"
547msgstr "Memory Controller detected a corrupted CRC error on a non-redundant retry of memory or dimm configuration read  Refer to %s for more information."
548msgid "INTEL-8001-1P.response"
549msgstr "Hardware redundancy or correction of memory errors may be lost"
550msgid "INTEL-8001-1P.impact"
551msgstr "There may be a loss of hardware redundancy or performance"
552msgid "INTEL-8001-1P.action"
553msgstr "reseat or replace dimm.  Use 'fmadm faulty' to identify the dimm."
554#
555# code: INTEL-8001-25
556# keys: fault.memory.intel.fbd.reset_timeout
557#
558msgid "INTEL-8001-25.type"
559msgstr "Fault"
560msgid "INTEL-8001-25.severity"
561msgstr "Critical"
562msgid "INTEL-8001-25.description"
563msgstr "Memory Controller detected fast reset timeout while trying to recover from read or write  Refer to %s for more information."
564msgid "INTEL-8001-25.response"
565msgstr "System panic or reset by BIOS"
566msgid "INTEL-8001-25.impact"
567msgstr "System may not boot"
568msgid "INTEL-8001-25.action"
569msgstr "reseat or replace dimm.  Use 'fmadm faulty' to identify the dimms."
570#
571# code: INTEL-8001-3S
572# keys: fault.memory.intel.fbd.otf
573#
574msgid "INTEL-8001-3S.type"
575msgstr "Fault"
576msgid "INTEL-8001-3S.severity"
577msgstr "Major"
578msgid "INTEL-8001-3S.description"
579msgstr "Intelligent throttling is disabled in the memory controller and the thermal sensor detected over temperature  Refer to %s for more information."
580msgid "INTEL-8001-3S.response"
581msgstr "System panic or reset by BIOS"
582msgid "INTEL-8001-3S.impact"
583msgstr "System may be unexpectedly reset"
584msgid "INTEL-8001-3S.action"
585msgstr "Enable intelligent throttling in BIOS or supply more cooling"
586#
587# code: INTEL-8001-43
588# keys: fault.cpu.intel.nb.ie
589#
590msgid "INTEL-8001-43.type"
591msgstr "Fault"
592msgid "INTEL-8001-43.severity"
593msgstr "Critical"
594msgid "INTEL-8001-43.description"
595msgstr "Northbridge has detected an internal error  Refer to %s for more information."
596msgid "INTEL-8001-43.response"
597msgstr "System panic or reset by BIOS"
598msgid "INTEL-8001-43.impact"
599msgstr "System may be unexpectedly reset"
600msgid "INTEL-8001-43.action"
601msgstr "Replace motherboard"
602#
603# code: INTEL-8001-5Y
604# keys: fault.cpu.intel.nb.dma
605#
606msgid "INTEL-8001-5Y.type"
607msgstr "Fault"
608msgid "INTEL-8001-5Y.severity"
609msgstr "Major"
610msgid "INTEL-8001-5Y.description"
611msgstr "Northbridge dma controller has detected an error  Refer to %s for more information."
612msgid "INTEL-8001-5Y.response"
613msgstr "System panic or reset by BIOS"
614msgid "INTEL-8001-5Y.impact"
615msgstr "System may be unexpectedly reset"
616msgid "INTEL-8001-5Y.action"
617msgstr "Replace motherboard"
618#
619# code: INTEL-8001-6D
620# keys: fault.memory.intel.fbd.mem_ds
621#
622msgid "INTEL-8001-6D.type"
623msgstr "Fault"
624msgid "INTEL-8001-6D.severity"
625msgstr "Major"
626msgid "INTEL-8001-6D.description"
627msgstr "The memory controller has deployed the spare dimm rank to replace a rank which has had too many errors  Refer to %s for more information."
628msgid "INTEL-8001-6D.response"
629msgstr "There is no spare rank for this memory controller"
630msgid "INTEL-8001-6D.impact"
631msgstr "There is a loss of hardware redundancy"
632msgid "INTEL-8001-6D.action"
633msgstr "Replace faulty dimm. Use 'fmadm faulty' to identify the dimm."
634#
635# code: INTEL-8001-7H
636# keys: fault.memory.intel.page_ce
637#
638msgid "INTEL-8001-7H.type"
639msgstr "Fault"
640msgid "INTEL-8001-7H.severity"
641msgstr "Minor"
642msgid "INTEL-8001-7H.description"
643msgstr "A page of memory has reported excessive correctable ECC errors.  Refer to %s for more information."
644msgid "INTEL-8001-7H.response"
645msgstr "\n\nIf Solaris is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n"
646msgid "INTEL-8001-7H.impact"
647msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n"
648msgid "INTEL-8001-7H.action"
649msgstr "No repair action is recommended at this time."
650#
651# code: INTEL-8001-8R
652# keys: fault.memory.intel.page_ue
653#
654msgid "INTEL-8001-8R.type"
655msgstr "Fault"
656msgid "INTEL-8001-8R.severity"
657msgstr "Major"
658msgid "INTEL-8001-8R.description"
659msgstr "A page of memory has encountered an uncorrectable multiple-bit error. This fault class is an internal implementation peculiarity and can be ignored by system administrators; action is only necessary if it is followed by a related dimm fault diagnosis (as should always be the case for uncorrectable errors).  Refer to %s for more information."
660msgid "INTEL-8001-8R.response"
661msgstr "\n\nIf Solaris is running on bare-metal (native boot) an attempt will be made to remove this memory page from service.\n"
662msgid "INTEL-8001-8R.impact"
663msgstr "\n\nRemoving a single page from service (where supported) has a negligible impact on performance.\n"
664msgid "INTEL-8001-8R.action"
665msgstr "No repair action is recommended at this time."
666#
667# code: INTEL-8001-94
668# keys: fault.memory.intel.dimm_ce
669#
670msgid "INTEL-8001-94.type"
671msgstr "Fault"
672msgid "INTEL-8001-94.severity"
673msgstr "Minor"
674msgid "INTEL-8001-94.description"
675msgstr "A memory module is experiencing excessive correctable ECC errors.  Refer to %s for more information."
676msgid "INTEL-8001-94.response"
677msgstr "\n\nIf Solaris is running on bare-metal (native) then affected memory pages associated with this memory module will be removed from service.\n"
678msgid "INTEL-8001-94.impact"
679msgstr "\n\nPage retirement (where supported) is capped at a small fraction of memory to avoid performance impact.\n"
680msgid "INTEL-8001-94.action"
681msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm faulty -u ' to identify the module."
682#
683# code: INTEL-8001-AQ
684# keys: fault.memory.intel.dimm_ue
685#
686msgid "INTEL-8001-AQ.type"
687msgstr "Fault"
688msgid "INTEL-8001-AQ.severity"
689msgstr "Critical"
690msgid "INTEL-8001-AQ.description"
691msgstr "A memory module has experienced an uncorrectable multiple-bit error.  Refer to %s for more information."
692msgid "INTEL-8001-AQ.response"
693msgstr "\n\nIf Solaris is running on bare-metal (native) then affected memory pages associated with this memory module will be removed from service.\n"
694msgid "INTEL-8001-AQ.impact"
695msgstr "\n\nPage retirement (where supported) is capped at a small fraction of memory to avoid performance impact.\n"
696msgid "INTEL-8001-AQ.action"
697msgstr "Schedule a repair procedure to replace the affected memory module. Use 'fmadm -u ' to identify the module."
698#
699# code: INTEL-8001-CC
700# keys: fault.cpu.intel.nb.otf
701#
702msgid "INTEL-8001-CC.type"
703msgstr "Fault"
704msgid "INTEL-8001-CC.severity"
705msgstr "Major"
706msgid "INTEL-8001-CC.description"
707msgstr "Northbridge detected over temperature  Refer to %s for more information."
708msgid "INTEL-8001-CC.response"
709msgstr "System panic or reset by BIOS"
710msgid "INTEL-8001-CC.impact"
711msgstr "System may be unexpectedly reset"
712msgid "INTEL-8001-CC.action"
713msgstr "Supply more cooling"
714#
715# code: INTEL-8001-DJ
716# keys: fault.cpu.intel.quickpath.mem_parity
717#
718msgid "INTEL-8001-DJ.type"
719msgstr "Fault"
720msgid "INTEL-8001-DJ.severity"
721msgstr "Major"
722msgid "INTEL-8001-DJ.description"
723msgstr "Bad parity detected in memory write buffer or byte mask.  Refer to %s for more information."
724msgid "INTEL-8001-DJ.response"
725msgstr "System panic or reset by BIOS"
726msgid "INTEL-8001-DJ.impact"
727msgstr "System may panic or be reset by BIOS"
728msgid "INTEL-8001-DJ.action"
729msgstr "Schedule a repair procedure to replace processor. Use 'fmadm faulty' to identify FRU."
730#
731# code: INTEL-8001-EE
732# keys: fault.cpu.intel.quickpath.mem_addr_parity
733#
734msgid "INTEL-8001-EE.type"
735msgstr "Fault"
736msgid "INTEL-8001-EE.severity"
737msgstr "Major"
738msgid "INTEL-8001-EE.description"
739msgstr "Bad parity detected in memory address within controller.  Refer to %s for more information."
740msgid "INTEL-8001-EE.response"
741msgstr "System panic or reset by BIOS"
742msgid "INTEL-8001-EE.impact"
743msgstr "System may panic or be reset by BIOS"
744msgid "INTEL-8001-EE.action"
745msgstr "Schedule a repair procedure to replace processor. Use 'fmadm faulty' to identify FRU."
746#
747# code: INTEL-8001-FX
748# keys: fault.cpu.intel.quickpath.mem_bad_addr
749#
750msgid "INTEL-8001-FX.type"
751msgstr "Fault"
752msgid "INTEL-8001-FX.severity"
753msgstr "Major"
754msgid "INTEL-8001-FX.description"
755msgstr "Memory address is outside range mapped to memory dimms.  Refer to %s for more information."
756msgid "INTEL-8001-FX.response"
757msgstr "System panic or reset by BIOS"
758msgid "INTEL-8001-FX.impact"
759msgstr "System may panic or be reset by BIOS"
760msgid "INTEL-8001-FX.action"
761msgstr "Schedule a repair procedure to replace processor. Use 'fmadm faulty' to identify FRU."
762#
763# code: INTEL-8001-G2
764# keys: fault.cpu.intel.quickpath.mem_spare
765#
766msgid "INTEL-8001-G2.type"
767msgstr "Fault"
768msgid "INTEL-8001-G2.severity"
769msgstr "Major"
770msgid "INTEL-8001-G2.description"
771msgstr "A fatal error occured while trying to deploy spare memory.  Refer to %s for more information."
772msgid "INTEL-8001-G2.response"
773msgstr "System panic or reset by BIOS"
774msgid "INTEL-8001-G2.impact"
775msgstr "System may panic or be reset by BIOS"
776msgid "INTEL-8001-G2.action"
777msgstr "Replace faulty dimm. Use 'fmadm faulty' to identify the dimm."
778#
779# code: INTEL-8001-HS
780# keys: fault.cpu.intel.quickpath.mem_bad_id
781#
782msgid "INTEL-8001-HS.type"
783msgstr "Fault"
784msgid "INTEL-8001-HS.severity"
785msgstr "Major"
786msgid "INTEL-8001-HS.description"
787msgstr "Memory controller received bad transaction tracker ID from interconnect.  Refer to %s for more information."
788msgid "INTEL-8001-HS.response"
789msgstr "System panic or reset by BIOS"
790msgid "INTEL-8001-HS.impact"
791msgstr "System may panic or be reset by BIOS"
792msgid "INTEL-8001-HS.action"
793msgstr "Schedule a repair procedure to replace processor. Use 'fmadm faulty' to identify FRU."
794#
795# code: INTEL-8001-J5
796# keys: fault.cpu.intel.quickpath.mem_redundant
797#
798msgid "INTEL-8001-J5.type"
799msgstr "Fault"
800msgid "INTEL-8001-J5.severity"
801msgstr "Minor"
802msgid "INTEL-8001-J5.description"
803msgstr "Memory Mirroring lost due to error.  Refer to %s for more information."
804msgid "INTEL-8001-J5.response"
805msgstr "There is no spare copy of memory"
806msgid "INTEL-8001-J5.impact"
807msgstr "There is a loss of hardware redundancy"
808msgid "INTEL-8001-J5.action"
809msgstr "Replace faulty dimm. Use 'fmadm faulty' to identify the dimm."
810#
811# code: INTEL-8001-KP
812# keys: fault.cpu.intel.quickpath.interconnect
813#
814msgid "INTEL-8001-KP.type"
815msgstr "Fault"
816msgid "INTEL-8001-KP.severity"
817msgstr "Major"
818msgid "INTEL-8001-KP.description"
819msgstr "Quickpath Deteced Error.  Refer to %s for more information."
820msgid "INTEL-8001-KP.response"
821msgstr "System panic or reset by BIOS"
822msgid "INTEL-8001-KP.impact"
823msgstr "System may panic or be reset by BIOS"
824msgid "INTEL-8001-KP.action"
825msgstr "Schedule a repair procedure to check seating of proccessors"