# # Copyright 2005 Sun Microsystems, Inc. All rights reserved. # Use is subject to license terms. # # CDDL HEADER START # # The contents of this file are subject to the terms of the # Common Development and Distribution License, Version 1.0 only # (the "License"). You may not use this file except in compliance # with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. # See the License for the specific language governing permissions # and limitations under the License. # # When distributing Covered Code, include this CDDL HEADER in each # file and include the License file at usr/src/OPENSOLARIS.LICENSE. # If applicable, add the following below this CDDL HEADER, with the # fields enclosed by brackets "[]" replaced with your own identifying # information: Portions Copyright [yyyy] [name of copyright owner] # # CDDL HEADER END # #ident "%Z%%M% %I% %E% SMI" # # code: SUNOS-8000-0G # keys: ereport.sunos.unix.fm_panic # msgid "SUNOS-8000-0G.type" msgstr "Error" msgid "SUNOS-8000-0G.severity" msgstr "Major" msgid "SUNOS-8000-0G.description" msgstr "Errors have been detected that require a reboot to ensure system integrity. Refer to %s for more information." msgid "SUNOS-8000-0G.response" msgstr "Solaris will attempt to save and diagnose the error telemetry" msgid "SUNOS-8000-0G.impact" msgstr "The system will sync files, save a crash dump if needed, and reboot" msgid "SUNOS-8000-0G.action" msgstr "Save the error summary below in case telemetry cannot be saved" # # code: SUNOS-8000-1L # keys: defect.sunos.eft.undiagnosable_problem # msgid "SUNOS-8000-1L.type" msgstr "Defect" msgid "SUNOS-8000-1L.severity" msgstr "Minor" msgid "SUNOS-8000-1L.description" msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis. This may indicate an incomplete EFT file provided or a defect in the diagnosis algorithm. Refer to %s for more information." msgid "SUNOS-8000-1L.response" msgstr "Error reports from the component will be logged for examination by Sun." msgid "SUNOS-8000-1L.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "SUNOS-8000-1L.action" msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." # # code: SUNOS-8000-20 # keys: defect.io.pci.driver fault.io.pci.device fault.io.pci.bus # msgid "SUNOS-8000-20.type" msgstr "Fault" msgid "SUNOS-8000-20.severity" msgstr "Critical" msgid "SUNOS-8000-20.description" msgstr "A problem was detected in the SUNOS subsystem or controlling software" msgid "SUNOS-8000-20.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-20.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-20.action" msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." # # code: SUNOS-8000-3V # keys: fault.io.pci.bus fault.io.pci.device # msgid "SUNOS-8000-3V.type" msgstr "Fault" msgid "SUNOS-8000-3V.severity" msgstr "Critical" msgid "SUNOS-8000-3V.description" msgstr "A problem was detected in the PCI subsystem" msgid "SUNOS-8000-3V.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-3V.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-3V.action" msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u to identify the device or contact Sun for support." # # code: SUNOS-8000-46 # keys: defect.io.pci.driver fault.io.pci.device # msgid "SUNOS-8000-46.type" msgstr "Fault" msgid "SUNOS-8000-46.severity" msgstr "Critical" msgid "SUNOS-8000-46.description" msgstr "A problem was detected in the PCI subsystem or controlling software" msgid "SUNOS-8000-46.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-46.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-46.action" msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." # # code: SUNOS-8000-5T # keys: defect.io.pci.driver fault.io.pci.bus # msgid "SUNOS-8000-5T.type" msgstr "Fault" msgid "SUNOS-8000-5T.severity" msgstr "Critical" msgid "SUNOS-8000-5T.description" msgstr "A problem was detected in the PCI subsystem or controlling software" msgid "SUNOS-8000-5T.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-5T.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-5T.action" msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." # # code: SUNOS-8000-69 # keys: fault.io.pci.device # msgid "SUNOS-8000-69.type" msgstr "Fault" msgid "SUNOS-8000-69.severity" msgstr "Critical" msgid "SUNOS-8000-69.description" msgstr "A problem was detected for a PCI controller" msgid "SUNOS-8000-69.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-69.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-69.action" msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u to identify the device or contact Sun for support." # # code: SUNOS-8000-7N # keys: fault.io.pci.bus # msgid "SUNOS-8000-7N.type" msgstr "Fault" msgid "SUNOS-8000-7N.severity" msgstr "Critical" msgid "SUNOS-8000-7N.description" msgstr "A problem was detected for a PCI bus" msgid "SUNOS-8000-7N.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-7N.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-7N.action" msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u to identify the device or contact Sun for support." # # code: SUNOS-8000-8W # keys: defect.io.pci.driver # # msgid "SUNOS-8000-8W.type" msgstr "Fault" msgid "SUNOS-8000-8W.severity" msgstr "Critical" msgid "SUNOS-8000-8W.description" msgstr "A problem was detected in the PCI controller software" msgid "SUNOS-8000-8W.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-8W.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-8W.action" msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u to identify the module/package, or contact Sun for support."