/* * CDDL HEADER START * * The contents of this file are subject to the terms of the * Common Development and Distribution License (the "License"). * You may not use this file except in compliance with the License. * * You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE * or http://www.opensolaris.org/os/licensing. * See the License for the specific language governing permissions * and limitations under the License. * * When distributing Covered Code, include this CDDL HEADER in each * file and include the License file at usr/src/OPENSOLARIS.LICENSE. * If applicable, add the following below this CDDL HEADER, with the * fields enclosed by brackets "[]" replaced with your own identifying * information: Portions Copyright [yyyy] [name of copyright owner] * * CDDL HEADER END */ /* * Copyright 2008 Sun Microsystems, Inc. All rights reserved. * Use is subject to license terms. */ /* Copyright (c) 1990 Mentat Inc. */ #ifndef _INET_ARP_H #define _INET_ARP_H #include #ifdef __cplusplus extern "C" { #endif /* * Warning: the interfaces described in this file are private to the * implementation. They may change at any time without notice and are not * documented. Do not depend on them. */ #define ARP_REQUEST 1 #define ARP_RESPONSE 2 #define RARP_REQUEST 3 #define RARP_RESPONSE 4 #define AR_IOCTL (((unsigned)'A' & 0xFF)<<8) #define CMD_IN_PROGRESS 0x10000 #define AR_ENTRY_ADD (AR_IOCTL + 1) #define AR_ENTRY_DELETE (AR_IOCTL + 2) #define AR_ENTRY_QUERY (AR_IOCTL + 3) #define AR_ENTRY_SQUERY (AR_IOCTL + 6) #define AR_MAPPING_ADD (AR_IOCTL + 7) #define AR_CLIENT_NOTIFY (AR_IOCTL + 8) #define AR_INTERFACE_UP (AR_IOCTL + 9) #define AR_INTERFACE_DOWN (AR_IOCTL + 10) #define AR_INTERFACE_ON (AR_IOCTL + 12) #define AR_INTERFACE_OFF (AR_IOCTL + 13) #define AR_DLPIOP_DONE (AR_IOCTL + 14) /* * This is not an ARP command per se, it is used to interface between * ARP and IP during close. */ #define AR_ARP_CLOSING (AR_IOCTL + 16) #define AR_ARP_EXTEND (AR_IOCTL + 17) /* Both ace_flags and area_flags; must also modify arp.c in mdb */ #define ACE_F_PERMANENT 0x0001 #define ACE_F_PUBLISH 0x0002 #define ACE_F_DYING 0x0004 #define ACE_F_RESOLVED 0x0008 /* Using bit mask extraction from target address */ #define ACE_F_MAPPING 0x0010 #define ACE_F_MYADDR 0x0020 /* IP claims to own this address */ #define ACE_F_UNVERIFIED 0x0040 /* DAD not yet complete */ #define ACE_F_AUTHORITY 0x0080 /* check for duplicate MACs */ #define ACE_F_DEFEND 0x0100 /* single transmit (area_flags only) */ #define ACE_F_OLD 0x0200 /* should revalidate when IP asks */ #define ACE_F_FAST 0x0400 /* fast probe enabled */ #define ACE_F_DELAYED 0x0800 /* rescheduled on arp_defend_rate */ #define ACE_F_DAD_ABORTED 0x1000 /* DAD was aborted on link down */ /* ared_flags */ #define ARED_F_PRESERVE_PERM 0x0001 /* preserve permanent ace */ /* ARP Command Structures */ /* arc_t - Common command overlay */ typedef struct ar_cmd_s { uint32_t arc_cmd; uint32_t arc_name_offset; uint32_t arc_name_length; } arc_t; /* * NOTE: when using area_t for an AR_ENTRY_SQUERY, the area_hw_addr_offset * field isn't what you might think. See comments in ip_multi.c where * the routine ill_create_squery() is called, and also in the routine * itself, to see how this field is used *only* when the area_t holds * an AR_ENTRY_SQUERY. */ typedef struct ar_entry_add_s { uint32_t area_cmd; uint32_t area_name_offset; uint32_t area_name_length; uint32_t area_proto; uint32_t area_proto_addr_offset; uint32_t area_proto_addr_length; uint32_t area_proto_mask_offset; uint32_t area_flags; /* Same values as ace_flags */ uint32_t area_hw_addr_offset; uint32_t area_hw_addr_length; } area_t; typedef struct ar_entry_delete_s { uint32_t ared_cmd; uint32_t ared_name_offset; uint32_t ared_name_length; uint32_t ared_proto; uint32_t ared_proto_addr_offset; uint32_t ared_proto_addr_length; uint32_t ared_flags; } ared_t; typedef struct ar_entry_query_s { uint32_t areq_cmd; uint32_t areq_name_offset; uint32_t areq_name_length; uint32_t areq_proto; uint32_t areq_target_addr_offset; uint32_t areq_target_addr_length; uint32_t areq_flags; uint32_t areq_sender_addr_offset; uint32_t areq_sender_addr_length; uint32_t areq_xmit_count; /* 0 ==> cache lookup only */ uint32_t areq_xmit_interval; /* # of milliseconds; 0: default */ /* # ofquests to buffer; 0: default */ uint32_t areq_max_buffered; uchar_t areq_sap[8]; /* to insert in returned template */ } areq_t; #define AR_EQ_DEFAULT_XMIT_COUNT 6 #define AR_EQ_DEFAULT_XMIT_INTERVAL 1000 #define AR_EQ_DEFAULT_MAX_BUFFERED 4 /* * Structure used with AR_ENTRY_LLAQUERY to map from the link_addr * (in Neighbor Discovery option format excluding the option type and * length) to a hardware address. * The response has the same format as for an AR_ENTRY_SQUERY - an M_CTL with * arel_hw_addr updated. * An IPv6 address will be passed in AR_ENTRY_LLAQUERY so that atmip * can send it in AR_CLIENT_NOTIFY messages. */ typedef struct ar_entry_llaquery_s { uint32_t arel_cmd; uint32_t arel_name_offset; uint32_t arel_name_length; uint32_t arel_link_addr_offset; uint32_t arel_link_addr_length; uint32_t arel_hw_addr_offset; uint32_t arel_hw_addr_length; uint32_t arel_ip_addr_offset; uint32_t arel_ip_addr_length; } arel_t; typedef struct ar_mapping_add_s { uint32_t arma_cmd; uint32_t arma_name_offset; uint32_t arma_name_length; uint32_t arma_proto; uint32_t arma_proto_addr_offset; uint32_t arma_proto_addr_length; uint32_t arma_proto_mask_offset; uint32_t arma_proto_extract_mask_offset; uint32_t arma_flags; uint32_t arma_hw_addr_offset; uint32_t arma_hw_addr_length; /* Offset were we start placing */ uint32_t arma_hw_mapping_start; /* the mask&proto_addr */ } arma_t; /* Structure used to notify clients of interesting conditions. */ typedef struct ar_client_notify_s { uint32_t arcn_cmd; uint32_t arcn_name_offset; uint32_t arcn_name_length; uint32_t arcn_code; /* Notification code. */ } arcn_t; /* Client Notification Codes */ #define AR_CN_BOGON 1 #define AR_CN_ANNOUNCE 2 #define AR_CN_READY 3 /* DAD complete; address usable */ #define AR_CN_FAILED 4 /* DAD failed; address unusable */ /* ARP Header */ typedef struct arh_s { uchar_t arh_hardware[2]; uchar_t arh_proto[2]; uchar_t arh_hlen; uchar_t arh_plen; uchar_t arh_operation[2]; /* The sender and target hw/proto pairs follow */ } arh_t; #ifdef __cplusplus } #endif #endif /* _INET_ARP_H */