# # Copyright 2010 Sun Microsystems, Inc. All rights reserved. # Use is subject to license terms. # # CDDL HEADER START # # The contents of this file are subject to the terms of the # Common Development and Distribution License (the "License"). # You may not use this file except in compliance with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. # See the License for the specific language governing permissions # and limitations under the License. # # When distributing Covered Code, include this CDDL HEADER in each # file and include the License file at usr/src/OPENSOLARIS.LICENSE. # If applicable, add the following below this CDDL HEADER, with the # fields enclosed by brackets "[]" replaced with your own identifying # information: Portions Copyright [yyyy] [name of copyright owner] # # CDDL HEADER END # # DO NOT EDIT -- this file is generated by the Event Registry. # # # code: SUNOS-8000-0G # keys: ereport.sunos.unix.fm_panic # msgid "SUNOS-8000-0G.type" msgstr "Error" msgid "SUNOS-8000-0G.severity" msgstr "Major" msgid "SUNOS-8000-0G.description" msgstr "Errors have been detected that require a reboot to ensure system integrity. Refer to %s for more information." msgid "SUNOS-8000-0G.response" msgstr "Solaris will attempt to save and diagnose the error telemetry" msgid "SUNOS-8000-0G.impact" msgstr "The system will sync files, save a crash dump if needed, and reboot" msgid "SUNOS-8000-0G.action" msgstr "Save the error summary below in case telemetry cannot be saved" # # code: SUNOS-8000-1L # keys: defect.sunos.eft.undiagnosable_problem # msgid "SUNOS-8000-1L.type" msgstr "Defect" msgid "SUNOS-8000-1L.severity" msgstr "Minor" msgid "SUNOS-8000-1L.description" msgstr "The EFT Diagnosis Engine encountered telemetry for which it is unable to produce a diagnosis. Refer to %s for more information." msgid "SUNOS-8000-1L.response" msgstr "Error reports from the component will be logged for examination by Sun." msgid "SUNOS-8000-1L.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "SUNOS-8000-1L.action" msgstr "Run pkgchk -n SUNWfmd to ensure that fault management software is installed properly. Contact Sun for support." # # code: SUNOS-8000-20 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus fault.io.pci.device # msgid "SUNOS-8000-20.type" msgstr "Fault" msgid "SUNOS-8000-20.severity" msgstr "Critical" msgid "SUNOS-8000-20.description" msgstr "A problem was detected in the SUNOS subsystem or controlling software. Refer to %s for more information." msgid "SUNOS-8000-20.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-20.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-20.action" msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." # # code: SUNOS-8000-3V # keys: defect.Deprecated fault.io.pci.bus fault.io.pci.device # msgid "SUNOS-8000-3V.type" msgstr "Fault" msgid "SUNOS-8000-3V.severity" msgstr "Critical" msgid "SUNOS-8000-3V.description" msgstr "A problem was detected in the PCI subsystem. Refer to %s for more information." msgid "SUNOS-8000-3V.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-3V.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-3V.action" msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." # # code: SUNOS-8000-46 # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.device # msgid "SUNOS-8000-46.type" msgstr "Fault" msgid "SUNOS-8000-46.severity" msgstr "Critical" msgid "SUNOS-8000-46.description" msgstr "A problem was detected in the PCI subsystem or controlling software. Refer to %s for more information." msgid "SUNOS-8000-46.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-46.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-46.action" msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." # # code: SUNOS-8000-5T # keys: defect.Deprecated defect.io.pci.driver fault.io.pci.bus # msgid "SUNOS-8000-5T.type" msgstr "Fault" msgid "SUNOS-8000-5T.severity" msgstr "Critical" msgid "SUNOS-8000-5T.description" msgstr "A problem was detected in the PCI subsystem or controlling software. Refer to %s for more information." msgid "SUNOS-8000-5T.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-5T.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUNOS-8000-5T.action" msgstr "Ensure latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." # # code: SUNOS-8000-69 # keys: defect.Deprecated fault.io.pci.device # msgid "SUNOS-8000-69.type" msgstr "Fault" msgid "SUNOS-8000-69.severity" msgstr "Critical" msgid "SUNOS-8000-69.description" msgstr "A problem was detected for a PCI controller Refer to %s for more information." msgid "SUNOS-8000-69.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-69.impact" msgstr "Loss of services provided by the device instances associated with this fault." msgid "SUNOS-8000-69.action" msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." # # code: SUNOS-8000-7N # keys: defect.Deprecated fault.io.pci.bus # msgid "SUNOS-8000-7N.type" msgstr "Fault" msgid "SUNOS-8000-7N.severity" msgstr "Critical" msgid "SUNOS-8000-7N.description" msgstr "A problem was detected for a PCI bus Refer to %s for more information." msgid "SUNOS-8000-7N.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-7N.impact" msgstr "Loss of services provided by the device instances associated with this fault." msgid "SUNOS-8000-7N.action" msgstr "Schedule a repair procedure to replace the affected device. Use fmdump -v -u <EVENT_ID> to identify the device or contact Sun for support." # # code: SUNOS-8000-8W # keys: defect.Deprecated defect.io.pci.driver # msgid "SUNOS-8000-8W.type" msgstr "Fault" msgid "SUNOS-8000-8W.severity" msgstr "Critical" msgid "SUNOS-8000-8W.description" msgstr "A problem was detected in the PCI controller software Refer to %s for more information." msgid "SUNOS-8000-8W.response" msgstr "One or more of device instances may be disabled" msgid "SUNOS-8000-8W.impact" msgstr "Loss of services provided by the device instances associated with this fault." msgid "SUNOS-8000-8W.action" msgstr "Ensure latest drivers and patches are installed. Use fmdump -v -u <EVENT_ID> to identify the module/package, or contact Sun for support." # # code: SUNOS-8000-91 # keys: defect.sunos.zones.upgrade # msgid "SUNOS-8000-91.type" msgstr "Defect" msgid "SUNOS-8000-91.severity" msgstr "Minor" msgid "SUNOS-8000-91.description" msgstr "\n The Solaris system or boot environment that is being upgraded\n has non-global zones installed. The current version of Live\n Upgrade cannot upgrade a boot environment that has non-global\n zones installed.\n Refer to %s for more information." msgid "SUNOS-8000-91.response" msgstr "The upgrade procedure has been terminated." msgid "SUNOS-8000-91.impact" msgstr "The Solaris system or boot environment is not upgraded." msgid "SUNOS-8000-91.action" msgstr "\n Evaluate each of the choices below and select the one that is\n best for your needs. Contact Sun for support.\n " # # code: SUNOS-8000-AK # keys: ereport.sunos.boot.upgrade.menu_lst # msgid "SUNOS-8000-AK.type" msgstr "Error" msgid "SUNOS-8000-AK.severity" msgstr "Critical" msgid "SUNOS-8000-AK.description" msgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n Refer to %s for more information." msgid "SUNOS-8000-AK.response" msgstr "No automated response.\n" msgid "SUNOS-8000-AK.impact" msgstr "Future reboots could fail until this problem is corrected.\n" msgid "SUNOS-8000-AK.action" msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details.\n" # # code: SUNOS-8000-CF # keys: ereport.sunos.boot.upgrade.menu_lst_bfu # msgid "SUNOS-8000-CF.type" msgstr "Error" msgid "SUNOS-8000-CF.severity" msgstr "Critical" msgid "SUNOS-8000-CF.description" msgstr "Solaris OS could not automatically adjust\n/boot/grub/menu.lst\nto the new boot architecture\n Refer to %s for more information." msgid "SUNOS-8000-CF.response" msgstr "No automated response.\n" msgid "SUNOS-8000-CF.impact" msgstr "Future reboots could fail until this problem is corrected.\n" msgid "SUNOS-8000-CF.action" msgstr "Examine /boot/grub/menu.lst and revise as\ndescribed in Details.\n" # # code: SUNOS-8000-DM # keys: defect.sunos.smf.svc.maintenance # msgid "SUNOS-8000-DM.type" msgstr "Defect" msgid "SUNOS-8000-DM.severity" msgstr "Major" msgid "SUNOS-8000-DM.description" msgstr "A service failed and could not be restarted. Refer to %s for more information." msgid "SUNOS-8000-DM.response" msgstr "The service has been placed into the maintenance state." msgid "SUNOS-8000-DM.impact" msgstr "The service is unavailable." msgid "SUNOS-8000-DM.action" msgstr "Run 'svcs -x' to determine why the service failed and the location of logfiles, if any." # # code: SUNOS-8000-E8 # keys: defect.sunos.eft.undiag.checkpoint # msgid "SUNOS-8000-E8.type" msgstr "Defect" msgid "SUNOS-8000-E8.severity" msgstr "Minor" msgid "SUNOS-8000-E8.description" msgstr "The diagnosis engine encountered an error while resuming diagnosis. Refer to %s for more information." msgid "SUNOS-8000-E8.response" msgstr "Error reports have been logged for examination by Sun." msgid "SUNOS-8000-E8.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "SUNOS-8000-E8.action" msgstr "Remove the diagnosis engine checkpoint file '/var/fm/fmd/ckpt/eft/eft', repair this defect, and restart the fault manager." # # code: SUNOS-8000-FU # keys: defect.sunos.eft.undiag.fme # msgid "SUNOS-8000-FU.type" msgstr "Defect" msgid "SUNOS-8000-FU.severity" msgstr "Major" msgid "SUNOS-8000-FU.description" msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis. Refer to %s for more information." msgid "SUNOS-8000-FU.response" msgstr "Error reports have been logged for examination by Sun." msgid "SUNOS-8000-FU.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "SUNOS-8000-FU.action" msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed." # # code: SUNOS-8000-G7 # keys: defect.sunos.eft.undiag.limit # msgid "SUNOS-8000-G7.type" msgstr "Defect" msgid "SUNOS-8000-G7.severity" msgstr "Minor" msgid "SUNOS-8000-G7.description" msgstr "The diagnosis engine hit a limit restriction and was unable to perform a diagnosis. Refer to %s for more information." msgid "SUNOS-8000-G7.response" msgstr "Error reports have been logged for examination by Sun." msgid "SUNOS-8000-G7.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "SUNOS-8000-G7.action" msgstr "Check the diagnosis engine configuration file '/usr/lib/fm/fmd/plugins/eft.conf' and ensure that no limit restrictions are set, then repair this defect, and restart the fault manager." # # code: SUNOS-8000-HV # keys: defect.sunos.eft.undiag.unknown # msgid "SUNOS-8000-HV.type" msgstr "Defect" msgid "SUNOS-8000-HV.severity" msgstr "Minor" msgid "SUNOS-8000-HV.description" msgstr "The diagnosis engine encountered telemetry for which it was unable to perform a diagnosis. Refer to %s for more information." msgid "SUNOS-8000-HV.response" msgstr "Error reports have been logged for examination by Sun." msgid "SUNOS-8000-HV.impact" msgstr "Automated diagnosis and response for these events will not occur." msgid "SUNOS-8000-HV.action" msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed." # # code: SUNOS-8000-J0 # keys: defect.sunos.eft.unexpected_telemetry fault.sunos.eft.unexpected_telemetry # msgid "SUNOS-8000-J0.type" msgstr "Fault" msgid "SUNOS-8000-J0.severity" msgstr "Major" msgid "SUNOS-8000-J0.description" msgstr "The diagnosis engine encountered telemetry from the listed devices for which it was unable to perform a diagnosis - %<fault-list[0].reason>.\n Refer to %s for more information." msgid "SUNOS-8000-J0.response" msgstr "Error reports have been logged for examination by Sun.\n" msgid "SUNOS-8000-J0.impact" msgstr "Automated diagnosis and response for these events will not occur.\n" msgid "SUNOS-8000-J0.action" msgstr "Ensure that the latest Solaris Kernel and Predictive Self-Healing (PSH) patches are installed.\n"