# # Copyright 2006 Sun Microsystems, Inc. All rights reserved. # Use is subject to license terms. # # CDDL HEADER START # # The contents of this file are subject to the terms of the # Common Development and Distribution License (the "License"). # You may not use this file except in compliance with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. # See the License for the specific language governing permissions # and limitations under the License. # # When distributing Covered Code, include this CDDL HEADER in each # file and include the License file at usr/src/OPENSOLARIS.LICENSE. # If applicable, add the following below this CDDL HEADER, with the # fields enclosed by brackets "[]" replaced with your own identifying # information: Portions Copyright [yyyy] [name of copyright owner] # # CDDL HEADER END # #ident "%Z%%M% %I% %E% SMI" # # DO NOT EDIT -- this file is generated by the Event Registry. # # # code: SUN4U-8000-1A # keys: fault.memory.page # msgid "SUN4U-8000-1A.type" msgstr "Fault" msgid "SUN4U-8000-1A.severity" msgstr "Minor" msgid "SUN4U-8000-1A.description" msgstr "The number of errors associated with this memory module continues to exceed acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-1A.response" msgstr "An attempt will be made to remove this memory page from service." msgid "SUN4U-8000-1A.impact" msgstr "The performance of the system may be minimally impacted as a result of removing the memory page from operation." msgid "SUN4U-8000-1A.action" msgstr "No repair action is recommended at this time." # # code: SUN4U-8000-2S # keys: fault.memory.dimm # msgid "SUN4U-8000-2S.type" msgstr "Fault" msgid "SUN4U-8000-2S.severity" msgstr "Major" msgid "SUN4U-8000-2S.description" msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-2S.response" msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." msgid "SUN4U-8000-2S.impact" msgstr "Total system memory capacity will be reduced as pages are retired." msgid "SUN4U-8000-2S.action" msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u to identify the module." # # code: SUN4U-8000-35 # keys: fault.memory.bank # msgid "SUN4U-8000-35.type" msgstr "Fault" msgid "SUN4U-8000-35.severity" msgstr "Critical" msgid "SUN4U-8000-35.description" msgstr "The number of errors associated with this memory module has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-35.response" msgstr "Pages of memory associated with this memory module are being removed from service as errors are reported." msgid "SUN4U-8000-35.impact" msgstr "Total system memory capacity will be reduced as pages are retired." msgid "SUN4U-8000-35.action" msgstr "Schedule a repair procedure to replace the affected memory module. Use fmdump -v -u to identify the module." # # code: SUN4U-8000-4Y # keys: fault.cpu.ultraSPARC-III.dcache # msgid "SUN4U-8000-4Y.type" msgstr "Fault" msgid "SUN4U-8000-4Y.severity" msgstr "Major" msgid "SUN4U-8000-4Y.description" msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-4Y.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-4Y.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-4Y.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-53 # keys: fault.cpu.ultraSPARC-III.icache # msgid "SUN4U-8000-53.type" msgstr "Fault" msgid "SUN4U-8000-53.severity" msgstr "Major" msgid "SUN4U-8000-53.description" msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-53.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-53.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-53.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-6H # keys: fault.cpu.ultraSPARC-III.l2cachedata # msgid "SUN4U-8000-6H.type" msgstr "Fault" msgid "SUN4U-8000-6H.severity" msgstr "Major" msgid "SUN4U-8000-6H.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-6H.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-6H.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-6H.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-7D # keys: fault.cpu.ultraSPARC-III.l2cachetag # msgid "SUN4U-8000-7D.type" msgstr "Fault" msgid "SUN4U-8000-7D.severity" msgstr "Major" msgid "SUN4U-8000-7D.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-7D.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-7D.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-7D.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-84 # keys: fault.cpu.ultraSPARC-IIIi.dcache # msgid "SUN4U-8000-84.type" msgstr "Fault" msgid "SUN4U-8000-84.severity" msgstr "Major" msgid "SUN4U-8000-84.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-84.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-84.impact" msgstr "System performance system may be affected." msgid "SUN4U-8000-84.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-9R # keys: fault.cpu.ultraSPARC-IIIi.icache # msgid "SUN4U-8000-9R.type" msgstr "Fault" msgid "SUN4U-8000-9R.severity" msgstr "Major" msgid "SUN4U-8000-9R.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-9R.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-9R.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-9R.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-AC # keys: fault.cpu.ultraSPARC-IIIi.l2cachedata # msgid "SUN4U-8000-AC.type" msgstr "Fault" msgid "SUN4U-8000-AC.severity" msgstr "Major" msgid "SUN4U-8000-AC.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-AC.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-AC.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-AC.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-CQ # keys: fault.cpu.ultraSPARC-IIIi.l2cachetag # msgid "SUN4U-8000-CQ.type" msgstr "Fault" msgid "SUN4U-8000-CQ.severity" msgstr "Major" msgid "SUN4U-8000-CQ.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-CQ.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-CQ.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-CQ.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-DE # keys: fault.cpu.ultraSPARC-IIIplus.dcache # msgid "SUN4U-8000-DE.type" msgstr "Fault" msgid "SUN4U-8000-DE.severity" msgstr "Major" msgid "SUN4U-8000-DE.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-DE.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-DE.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-DE.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-EJ # keys: fault.cpu.ultraSPARC-IIIplus.icache # msgid "SUN4U-8000-EJ.type" msgstr "Fault" msgid "SUN4U-8000-EJ.severity" msgstr "Major" msgid "SUN4U-8000-EJ.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-EJ.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-EJ.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-EJ.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-F2 # keys: fault.cpu.ultraSPARC-IIIplus.l2cachedata # msgid "SUN4U-8000-F2.type" msgstr "Fault" msgid "SUN4U-8000-F2.severity" msgstr "Major" msgid "SUN4U-8000-F2.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-F2.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-F2.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-F2.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-GX # keys: fault.cpu.ultraSPARC-IIIplus.l2cachetag # msgid "SUN4U-8000-GX.type" msgstr "Fault" msgid "SUN4U-8000-GX.severity" msgstr "Major" msgid "SUN4U-8000-GX.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-GX.response" msgstr "An attempt will be made to remove the affected CPU from service." msgid "SUN4U-8000-GX.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-GX.action" msgstr "Schedule a repair procedure to replace the affected CPU. Use fmdump -v -u to identify the CPU." # # code: SUN4U-8000-H5 # keys: fault.cpu.ultraSPARC-IV.dcache # msgid "SUN4U-8000-H5.type" msgstr "Fault" msgid "SUN4U-8000-H5.severity" msgstr "Major" msgid "SUN4U-8000-H5.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-H5.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-H5.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-H5.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-JS # keys: fault.cpu.ultraSPARC-IV.icache # msgid "SUN4U-8000-JS.type" msgstr "Fault" msgid "SUN4U-8000-JS.severity" msgstr "Major" msgid "SUN4U-8000-JS.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-JS.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-JS.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-JS.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-KA # keys: fault.cpu.ultraSPARC-IV.l2cachedata # msgid "SUN4U-8000-KA.type" msgstr "Fault" msgid "SUN4U-8000-KA.severity" msgstr "Major" msgid "SUN4U-8000-KA.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-KA.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-KA.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-KA.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-LP # keys: fault.cpu.ultraSPARC-IV.l2cachetag # msgid "SUN4U-8000-LP.type" msgstr "Fault" msgid "SUN4U-8000-LP.severity" msgstr "Major" msgid "SUN4U-8000-LP.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-LP.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-LP.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-LP.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-MD # keys: fault.cpu.ultraSPARC-III.fpu # msgid "SUN4U-8000-MD.type" msgstr "Fault" msgid "SUN4U-8000-MD.severity" msgstr "Major" msgid "SUN4U-8000-MD.description" msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." msgid "SUN4U-8000-MD.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-MD.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-MD.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-NH # keys: fault.cpu.ultraSPARC-IIIi.fpu # msgid "SUN4U-8000-NH.type" msgstr "Fault" msgid "SUN4U-8000-NH.severity" msgstr "Major" msgid "SUN4U-8000-NH.description" msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." msgid "SUN4U-8000-NH.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-NH.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-NH.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-P3 # keys: fault.cpu.ultraSPARC-IIIplus.fpu # msgid "SUN4U-8000-P3.type" msgstr "Fault" msgid "SUN4U-8000-P3.severity" msgstr "Major" msgid "SUN4U-8000-P3.description" msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." msgid "SUN4U-8000-P3.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-P3.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-P3.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-QY # keys: fault.cpu.ultraSPARC-IV.fpu # msgid "SUN4U-8000-QY.type" msgstr "Fault" msgid "SUN4U-8000-QY.severity" msgstr "Major" msgid "SUN4U-8000-QY.description" msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." msgid "SUN4U-8000-QY.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-QY.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-QY.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-RQ # keys: fault.cpu.ultraSPARC-IVplus.fpu # msgid "SUN4U-8000-RQ.type" msgstr "Fault" msgid "SUN4U-8000-RQ.severity" msgstr "Major" msgid "SUN4U-8000-RQ.description" msgstr "A fault has been detected in the FPU of this CPU. Refer to %s for more information." msgid "SUN4U-8000-RQ.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-RQ.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-RQ.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-SC # keys: fault.cpu.ultraSPARC-IVplus.dcache # msgid "SUN4U-8000-SC.type" msgstr "Fault" msgid "SUN4U-8000-SC.severity" msgstr "Major" msgid "SUN4U-8000-SC.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-SC.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-SC.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-SC.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-TR # keys: fault.cpu.ultraSPARC-IVplus.icache # msgid "SUN4U-8000-TR.type" msgstr "Fault" msgid "SUN4U-8000-TR.severity" msgstr "Major" msgid "SUN4U-8000-TR.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-TR.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-TR.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-TR.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-U4 # keys: fault.cpu.ultraSPARC-IVplus.pcache # msgid "SUN4U-8000-U4.type" msgstr "Fault" msgid "SUN4U-8000-U4.severity" msgstr "Major" msgid "SUN4U-8000-U4.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-U4.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-U4.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-U4.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-VX # keys: fault.cpu.ultraSPARC-IVplus.dtlb # msgid "SUN4U-8000-VX.type" msgstr "Fault" msgid "SUN4U-8000-VX.severity" msgstr "Major" msgid "SUN4U-8000-VX.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-VX.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-VX.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-VX.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-W2 # keys: fault.cpu.ultraSPARC-IVplus.itlb # msgid "SUN4U-8000-W2.type" msgstr "Fault" msgid "SUN4U-8000-W2.severity" msgstr "Major" msgid "SUN4U-8000-W2.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-W2.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-W2.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-W2.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-XJ # keys: fault.cpu.ultraSPARC-IVplus.l2cachedata # msgid "SUN4U-8000-XJ.type" msgstr "Fault" msgid "SUN4U-8000-XJ.severity" msgstr "Major" msgid "SUN4U-8000-XJ.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-XJ.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-XJ.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-XJ.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8000-YE # keys: fault.cpu.ultraSPARC-IVplus.l2cachetag # msgid "SUN4U-8000-YE.type" msgstr "Fault" msgid "SUN4U-8000-YE.severity" msgstr "Major" msgid "SUN4U-8000-YE.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8000-YE.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8000-YE.impact" msgstr "System performance may be affected." msgid "SUN4U-8000-YE.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8001-0J # keys: fault.cpu.ultraSPARC-IVplus.l3cachedata # msgid "SUN4U-8001-0J.type" msgstr "Fault" msgid "SUN4U-8001-0J.severity" msgstr "Major" msgid "SUN4U-8001-0J.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8001-0J.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8001-0J.impact" msgstr "System performance may be affected." msgid "SUN4U-8001-0J.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8001-1E # keys: fault.cpu.ultraSPARC-IVplus.l3cachetag # msgid "SUN4U-8001-1E.type" msgstr "Fault" msgid "SUN4U-8001-1E.severity" msgstr "Major" msgid "SUN4U-8001-1E.description" msgstr "The number of errors associated with this CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8001-1E.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8001-1E.impact" msgstr "System performance may be affected." msgid "SUN4U-8001-1E.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8001-2X # keys: defect.ultraSPARC-II.memory.nodiag # msgid "SUN4U-8001-2X.type" msgstr "Defect" msgid "SUN4U-8001-2X.severity" msgstr "Minor" msgid "SUN4U-8001-2X.description" msgstr "The Solaris Fault Manager received an event from the IO subsystem for which automated diagnosis software is currently unavailable. Refer to %s for more information." msgid "SUN4U-8001-2X.response" msgstr "The error information has been saved for examination by Sun." msgid "SUN4U-8001-2X.impact" msgstr "The error log will need to be manually examined using fmdump(1M) in order to determine if any human response is required." msgid "SUN4U-8001-2X.action" msgstr "Use fmdump -ev -u to view and record the undiagnosed errors." # # code: SUN4U-8001-32 # keys: fault.memory.datapath # msgid "SUN4U-8001-32.type" msgstr "Fault" msgid "SUN4U-8001-32.severity" msgstr "Major" msgid "SUN4U-8001-32.description" msgstr "Errors have been detected on multiple memory modules, suggesting that a problem exists somewhere else in the system. Refer to %s for more information." msgid "SUN4U-8001-32.response" msgstr "Error reports from the affected components will be logged for examination by Sun." msgid "SUN4U-8001-32.impact" msgstr "System performance and stability may be affected." msgid "SUN4U-8001-32.action" msgstr "Contact your service provider for further diagnosis." # # code: SUN4U-8001-4R # keys: fault.io.datapath # msgid "SUN4U-8001-4R.type" msgstr "Fault" msgid "SUN4U-8001-4R.severity" msgstr "Critical" msgid "SUN4U-8001-4R.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-4R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-4R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-4R.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-54 # keys: defect.io.pci.driver fault.io.datapath # msgid "SUN4U-8001-54.type" msgstr "Fault" msgid "SUN4U-8001-54.severity" msgstr "Critical" msgid "SUN4U-8001-54.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-54.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-54.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-54.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-6Q # keys: fault.io.datapath fault.io.pci.bus # msgid "SUN4U-8001-6Q.type" msgstr "Fault" msgid "SUN4U-8001-6Q.severity" msgstr "Critical" msgid "SUN4U-8001-6Q.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-6Q.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-6Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-6Q.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-7C # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus # msgid "SUN4U-8001-7C.type" msgstr "Fault" msgid "SUN4U-8001-7C.severity" msgstr "Critical" msgid "SUN4U-8001-7C.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-7C.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-7C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-7C.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-83 # keys: fault.io.datapath fault.io.pci.device # msgid "SUN4U-8001-83.type" msgstr "Fault" msgid "SUN4U-8001-83.severity" msgstr "Critical" msgid "SUN4U-8001-83.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-83.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-83.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-83.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-9Y # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device # msgid "SUN4U-8001-9Y.type" msgstr "Fault" msgid "SUN4U-8001-9Y.severity" msgstr "Critical" msgid "SUN4U-8001-9Y.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-9Y.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-9Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-9Y.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-AD # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-AD.type" msgstr "Fault" msgid "SUN4U-8001-AD.severity" msgstr "Critical" msgid "SUN4U-8001-AD.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-AD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-AD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-AD.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-CH # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-CH.type" msgstr "Fault" msgid "SUN4U-8001-CH.severity" msgstr "Critical" msgid "SUN4U-8001-CH.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-CH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-CH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-CH.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-DA # keys: fault.io.hbus # msgid "SUN4U-8001-DA.type" msgstr "Fault" msgid "SUN4U-8001-DA.severity" msgstr "Critical" msgid "SUN4U-8001-DA.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-DA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-DA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-DA.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-EP # keys: defect.io.pci.driver fault.io.hbus # msgid "SUN4U-8001-EP.type" msgstr "Fault" msgid "SUN4U-8001-EP.severity" msgstr "Critical" msgid "SUN4U-8001-EP.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-EP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-EP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-EP.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-F5 # keys: fault.io.hbus fault.io.pci.bus # msgid "SUN4U-8001-F5.type" msgstr "Fault" msgid "SUN4U-8001-F5.severity" msgstr "Critical" msgid "SUN4U-8001-F5.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-F5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-F5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-F5.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-GS # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus # msgid "SUN4U-8001-GS.type" msgstr "Fault" msgid "SUN4U-8001-GS.severity" msgstr "Critical" msgid "SUN4U-8001-GS.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-GS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-GS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-GS.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-H2 # keys: fault.io.hbus fault.io.pci.device # msgid "SUN4U-8001-H2.type" msgstr "Fault" msgid "SUN4U-8001-H2.severity" msgstr "Critical" msgid "SUN4U-8001-H2.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-H2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-H2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-H2.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-JX # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device # msgid "SUN4U-8001-JX.type" msgstr "Fault" msgid "SUN4U-8001-JX.severity" msgstr "Critical" msgid "SUN4U-8001-JX.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-JX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-JX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-JX.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-KE # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-KE.type" msgstr "Fault" msgid "SUN4U-8001-KE.severity" msgstr "Critical" msgid "SUN4U-8001-KE.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-KE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-KE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-KE.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-LJ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-LJ.type" msgstr "Fault" msgid "SUN4U-8001-LJ.severity" msgstr "Critical" msgid "SUN4U-8001-LJ.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-LJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-LJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-LJ.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-MC # keys: fault.io.datapath fault.io.hbus # msgid "SUN4U-8001-MC.type" msgstr "Fault" msgid "SUN4U-8001-MC.severity" msgstr "Critical" msgid "SUN4U-8001-MC.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-MC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-MC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-MC.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-NQ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus # msgid "SUN4U-8001-NQ.type" msgstr "Fault" msgid "SUN4U-8001-NQ.severity" msgstr "Critical" msgid "SUN4U-8001-NQ.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-NQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-NQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-NQ.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-P4 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus # msgid "SUN4U-8001-P4.type" msgstr "Fault" msgid "SUN4U-8001-P4.severity" msgstr "Critical" msgid "SUN4U-8001-P4.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-P4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-P4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-P4.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-QR # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus # msgid "SUN4U-8001-QR.type" msgstr "Fault" msgid "SUN4U-8001-QR.severity" msgstr "Critical" msgid "SUN4U-8001-QR.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-QR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-QR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-QR.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-RH # keys: fault.io.datapath fault.io.hbus fault.io.pci.device # msgid "SUN4U-8001-RH.type" msgstr "Fault" msgid "SUN4U-8001-RH.severity" msgstr "Critical" msgid "SUN4U-8001-RH.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-RH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-RH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-RH.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-SD # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device # msgid "SUN4U-8001-SD.type" msgstr "Fault" msgid "SUN4U-8001-SD.severity" msgstr "Critical" msgid "SUN4U-8001-SD.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-SD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-SD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-SD.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-TY # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-TY.type" msgstr "Fault" msgid "SUN4U-8001-TY.severity" msgstr "Critical" msgid "SUN4U-8001-TY.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-TY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-TY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-TY.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-U3 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device # msgid "SUN4U-8001-U3.type" msgstr "Fault" msgid "SUN4U-8001-U3.severity" msgstr "Critical" msgid "SUN4U-8001-U3.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-U3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-U3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-U3.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-VS # keys: fault.io.schizo # msgid "SUN4U-8001-VS.type" msgstr "Fault" msgid "SUN4U-8001-VS.severity" msgstr "Critical" msgid "SUN4U-8001-VS.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-VS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-VS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-VS.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-W5 # keys: defect.io.pci.driver fault.io.schizo # msgid "SUN4U-8001-W5.type" msgstr "Fault" msgid "SUN4U-8001-W5.severity" msgstr "Critical" msgid "SUN4U-8001-W5.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-W5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-W5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-W5.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8001-XP # keys: fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8001-XP.type" msgstr "Fault" msgid "SUN4U-8001-XP.severity" msgstr "Critical" msgid "SUN4U-8001-XP.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8001-XP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-XP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-XP.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8001-YA # keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8001-YA.type" msgstr "Fault" msgid "SUN4U-8001-YA.severity" msgstr "Critical" msgid "SUN4U-8001-YA.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8001-YA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8001-YA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8001-YA.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-0R # keys: fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-0R.type" msgstr "Fault" msgid "SUN4U-8002-0R.severity" msgstr "Critical" msgid "SUN4U-8002-0R.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-0R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-0R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-0R.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-14 # keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-14.type" msgstr "Fault" msgid "SUN4U-8002-14.severity" msgstr "Critical" msgid "SUN4U-8002-14.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-14.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-14.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-14.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-2Q # keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-2Q.type" msgstr "Fault" msgid "SUN4U-8002-2Q.severity" msgstr "Critical" msgid "SUN4U-8002-2Q.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-2Q.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-2Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-2Q.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-3C # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-3C.type" msgstr "Fault" msgid "SUN4U-8002-3C.severity" msgstr "Critical" msgid "SUN4U-8002-3C.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-3C.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-3C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-3C.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-4J # keys: fault.io.datapath fault.io.schizo # msgid "SUN4U-8002-4J.type" msgstr "Fault" msgid "SUN4U-8002-4J.severity" msgstr "Critical" msgid "SUN4U-8002-4J.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-4J.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-4J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-4J.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-5E # keys: defect.io.pci.driver fault.io.datapath fault.io.schizo # msgid "SUN4U-8002-5E.type" msgstr "Fault" msgid "SUN4U-8002-5E.severity" msgstr "Critical" msgid "SUN4U-8002-5E.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-5E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-5E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-5E.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-6X # keys: fault.io.datapath fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-6X.type" msgstr "Fault" msgid "SUN4U-8002-6X.severity" msgstr "Critical" msgid "SUN4U-8002-6X.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-6X.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-6X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-6X.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-72 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-72.type" msgstr "Fault" msgid "SUN4U-8002-72.severity" msgstr "Critical" msgid "SUN4U-8002-72.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-72.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-72.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-72.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-8A # keys: fault.io.datapath fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-8A.type" msgstr "Fault" msgid "SUN4U-8002-8A.severity" msgstr "Critical" msgid "SUN4U-8002-8A.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-8A.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-8A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-8A.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-9P # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-9P.type" msgstr "Fault" msgid "SUN4U-8002-9P.severity" msgstr "Critical" msgid "SUN4U-8002-9P.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-9P.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-9P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-9P.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-A5 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-A5.type" msgstr "Fault" msgid "SUN4U-8002-A5.severity" msgstr "Critical" msgid "SUN4U-8002-A5.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-A5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-A5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-A5.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-CS # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-CS.type" msgstr "Fault" msgid "SUN4U-8002-CS.severity" msgstr "Critical" msgid "SUN4U-8002-CS.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-CS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-CS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-CS.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-D3 # keys: fault.io.hbus fault.io.schizo # msgid "SUN4U-8002-D3.type" msgstr "Fault" msgid "SUN4U-8002-D3.severity" msgstr "Critical" msgid "SUN4U-8002-D3.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-D3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-D3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-D3.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-EY # keys: defect.io.pci.driver fault.io.hbus fault.io.schizo # msgid "SUN4U-8002-EY.type" msgstr "Fault" msgid "SUN4U-8002-EY.severity" msgstr "Critical" msgid "SUN4U-8002-EY.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-EY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-EY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-EY.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-FD # keys: fault.io.hbus fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-FD.type" msgstr "Fault" msgid "SUN4U-8002-FD.severity" msgstr "Critical" msgid "SUN4U-8002-FD.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-FD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-FD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-FD.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-GH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-GH.type" msgstr "Fault" msgid "SUN4U-8002-GH.severity" msgstr "Critical" msgid "SUN4U-8002-GH.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-GH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-GH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-GH.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-HC # keys: fault.io.hbus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-HC.type" msgstr "Fault" msgid "SUN4U-8002-HC.severity" msgstr "Critical" msgid "SUN4U-8002-HC.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-HC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-HC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-HC.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-JQ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-JQ.type" msgstr "Fault" msgid "SUN4U-8002-JQ.severity" msgstr "Critical" msgid "SUN4U-8002-JQ.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-JQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-JQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-JQ.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-K4 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-K4.type" msgstr "Fault" msgid "SUN4U-8002-K4.severity" msgstr "Critical" msgid "SUN4U-8002-K4.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-K4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-K4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-K4.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-LR # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-LR.type" msgstr "Fault" msgid "SUN4U-8002-LR.severity" msgstr "Critical" msgid "SUN4U-8002-LR.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-LR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-LR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-LR.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-M2 # keys: fault.io.datapath fault.io.hbus fault.io.schizo # msgid "SUN4U-8002-M2.type" msgstr "Fault" msgid "SUN4U-8002-M2.severity" msgstr "Critical" msgid "SUN4U-8002-M2.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-M2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-M2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-M2.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-NX # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo # msgid "SUN4U-8002-NX.type" msgstr "Fault" msgid "SUN4U-8002-NX.severity" msgstr "Critical" msgid "SUN4U-8002-NX.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-NX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-NX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-NX.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-PE # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-PE.type" msgstr "Fault" msgid "SUN4U-8002-PE.severity" msgstr "Critical" msgid "SUN4U-8002-PE.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-PE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-PE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-PE.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-QJ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo # msgid "SUN4U-8002-QJ.type" msgstr "Fault" msgid "SUN4U-8002-QJ.severity" msgstr "Critical" msgid "SUN4U-8002-QJ.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-QJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-QJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-QJ.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-RS # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-RS.type" msgstr "Fault" msgid "SUN4U-8002-RS.severity" msgstr "Critical" msgid "SUN4U-8002-RS.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-RS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-RS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-RS.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-S5 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-S5.type" msgstr "Fault" msgid "SUN4U-8002-S5.severity" msgstr "Critical" msgid "SUN4U-8002-S5.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-S5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-S5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-S5.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-TP # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-TP.type" msgstr "Fault" msgid "SUN4U-8002-TP.severity" msgstr "Critical" msgid "SUN4U-8002-TP.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-TP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-TP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-TP.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-UA # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo # msgid "SUN4U-8002-UA.type" msgstr "Fault" msgid "SUN4U-8002-UA.severity" msgstr "Critical" msgid "SUN4U-8002-UA.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-UA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-UA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-UA.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-VH # keys: fault.io.xmits # msgid "SUN4U-8002-VH.type" msgstr "Fault" msgid "SUN4U-8002-VH.severity" msgstr "Critical" msgid "SUN4U-8002-VH.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-VH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-VH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-VH.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-WD # keys: defect.io.pci.driver fault.io.xmits # msgid "SUN4U-8002-WD.type" msgstr "Fault" msgid "SUN4U-8002-WD.severity" msgstr "Critical" msgid "SUN4U-8002-WD.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-WD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-WD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-WD.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8002-XY # keys: fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8002-XY.type" msgstr "Fault" msgid "SUN4U-8002-XY.severity" msgstr "Critical" msgid "SUN4U-8002-XY.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8002-XY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-XY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-XY.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8002-Y3 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8002-Y3.type" msgstr "Fault" msgid "SUN4U-8002-Y3.severity" msgstr "Critical" msgid "SUN4U-8002-Y3.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8002-Y3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8002-Y3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8002-Y3.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-0Y # keys: fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-0Y.type" msgstr "Fault" msgid "SUN4U-8003-0Y.severity" msgstr "Critical" msgid "SUN4U-8003-0Y.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-0Y.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-0Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-0Y.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-13 # keys: defect.io.pci.driver fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-13.type" msgstr "Fault" msgid "SUN4U-8003-13.severity" msgstr "Critical" msgid "SUN4U-8003-13.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-13.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-13.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-13.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-2H # keys: fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-2H.type" msgstr "Fault" msgid "SUN4U-8003-2H.severity" msgstr "Critical" msgid "SUN4U-8003-2H.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-2H.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-2H.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-2H.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-3D # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-3D.type" msgstr "Fault" msgid "SUN4U-8003-3D.severity" msgstr "Critical" msgid "SUN4U-8003-3D.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-3D.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-3D.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-3D.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-4P # keys: fault.io.datapath fault.io.xmits # msgid "SUN4U-8003-4P.type" msgstr "Fault" msgid "SUN4U-8003-4P.severity" msgstr "Critical" msgid "SUN4U-8003-4P.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-4P.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-4P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-4P.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-5A # keys: defect.io.pci.driver fault.io.datapath fault.io.xmits # msgid "SUN4U-8003-5A.type" msgstr "Fault" msgid "SUN4U-8003-5A.severity" msgstr "Critical" msgid "SUN4U-8003-5A.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-5A.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-5A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-5A.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-6S # keys: fault.io.datapath fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-6S.type" msgstr "Fault" msgid "SUN4U-8003-6S.severity" msgstr "Critical" msgid "SUN4U-8003-6S.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-6S.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-6S.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-6S.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-75 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-75.type" msgstr "Fault" msgid "SUN4U-8003-75.severity" msgstr "Critical" msgid "SUN4U-8003-75.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-75.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-75.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-75.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-8E # keys: fault.io.datapath fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-8E.type" msgstr "Fault" msgid "SUN4U-8003-8E.severity" msgstr "Critical" msgid "SUN4U-8003-8E.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-8E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-8E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-8E.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-9J # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-9J.type" msgstr "Fault" msgid "SUN4U-8003-9J.severity" msgstr "Critical" msgid "SUN4U-8003-9J.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-9J.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-9J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-9J.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-A2 # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-A2.type" msgstr "Fault" msgid "SUN4U-8003-A2.severity" msgstr "Critical" msgid "SUN4U-8003-A2.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-A2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-A2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-A2.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-CX # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-CX.type" msgstr "Fault" msgid "SUN4U-8003-CX.severity" msgstr "Critical" msgid "SUN4U-8003-CX.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-CX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-CX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-CX.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-D4 # keys: fault.io.hbus fault.io.xmits # msgid "SUN4U-8003-D4.type" msgstr "Fault" msgid "SUN4U-8003-D4.severity" msgstr "Critical" msgid "SUN4U-8003-D4.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-D4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-D4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-D4.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-ER # keys: defect.io.pci.driver fault.io.hbus fault.io.xmits # msgid "SUN4U-8003-ER.type" msgstr "Fault" msgid "SUN4U-8003-ER.severity" msgstr "Critical" msgid "SUN4U-8003-ER.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-ER.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-ER.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-ER.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-FC # keys: fault.io.hbus fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-FC.type" msgstr "Fault" msgid "SUN4U-8003-FC.severity" msgstr "Critical" msgid "SUN4U-8003-FC.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-FC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-FC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-FC.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-GQ # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-GQ.type" msgstr "Fault" msgid "SUN4U-8003-GQ.severity" msgstr "Critical" msgid "SUN4U-8003-GQ.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-GQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-GQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-GQ.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-HD # keys: fault.io.hbus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-HD.type" msgstr "Fault" msgid "SUN4U-8003-HD.severity" msgstr "Critical" msgid "SUN4U-8003-HD.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-HD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-HD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-HD.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-JH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-JH.type" msgstr "Fault" msgid "SUN4U-8003-JH.severity" msgstr "Critical" msgid "SUN4U-8003-JH.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-JH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-JH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-JH.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-K3 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-K3.type" msgstr "Fault" msgid "SUN4U-8003-K3.severity" msgstr "Critical" msgid "SUN4U-8003-K3.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-K3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-K3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-K3.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-LY # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-LY.type" msgstr "Fault" msgid "SUN4U-8003-LY.severity" msgstr "Critical" msgid "SUN4U-8003-LY.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-LY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-LY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-LY.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-M5 # keys: fault.io.datapath fault.io.hbus fault.io.xmits # msgid "SUN4U-8003-M5.type" msgstr "Fault" msgid "SUN4U-8003-M5.severity" msgstr "Critical" msgid "SUN4U-8003-M5.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-M5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-M5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-M5.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-NS # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.xmits # msgid "SUN4U-8003-NS.type" msgstr "Fault" msgid "SUN4U-8003-NS.severity" msgstr "Critical" msgid "SUN4U-8003-NS.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-NS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-NS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-NS.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-PA # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-PA.type" msgstr "Fault" msgid "SUN4U-8003-PA.severity" msgstr "Critical" msgid "SUN4U-8003-PA.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-PA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-PA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-PA.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-QP # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.xmits # msgid "SUN4U-8003-QP.type" msgstr "Fault" msgid "SUN4U-8003-QP.severity" msgstr "Critical" msgid "SUN4U-8003-QP.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-QP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-QP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-QP.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-RX # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-RX.type" msgstr "Fault" msgid "SUN4U-8003-RX.severity" msgstr "Critical" msgid "SUN4U-8003-RX.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-RX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-RX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-RX.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-S2 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-S2.type" msgstr "Fault" msgid "SUN4U-8003-S2.severity" msgstr "Critical" msgid "SUN4U-8003-S2.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-S2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-S2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-S2.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-TJ # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-TJ.type" msgstr "Fault" msgid "SUN4U-8003-TJ.severity" msgstr "Critical" msgid "SUN4U-8003-TJ.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-TJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-TJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-TJ.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-UE # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.xmits # msgid "SUN4U-8003-UE.type" msgstr "Fault" msgid "SUN4U-8003-UE.severity" msgstr "Critical" msgid "SUN4U-8003-UE.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-UE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-UE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-UE.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-VQ # keys: fault.io.schizo fault.io.xmits # msgid "SUN4U-8003-VQ.type" msgstr "Fault" msgid "SUN4U-8003-VQ.severity" msgstr "Critical" msgid "SUN4U-8003-VQ.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-VQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-VQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-VQ.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-WC # keys: defect.io.pci.driver fault.io.schizo fault.io.xmits # msgid "SUN4U-8003-WC.type" msgstr "Fault" msgid "SUN4U-8003-WC.severity" msgstr "Critical" msgid "SUN4U-8003-WC.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-WC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-WC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-WC.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8003-XR # keys: fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8003-XR.type" msgstr "Fault" msgid "SUN4U-8003-XR.severity" msgstr "Critical" msgid "SUN4U-8003-XR.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8003-XR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-XR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-XR.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8003-Y4 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8003-Y4.type" msgstr "Fault" msgid "SUN4U-8003-Y4.severity" msgstr "Critical" msgid "SUN4U-8003-Y4.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8003-Y4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8003-Y4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8003-Y4.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-0A # keys: fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-0A.type" msgstr "Fault" msgid "SUN4U-8004-0A.severity" msgstr "Critical" msgid "SUN4U-8004-0A.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-0A.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-0A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-0A.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-1P # keys: defect.io.pci.driver fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-1P.type" msgstr "Fault" msgid "SUN4U-8004-1P.severity" msgstr "Critical" msgid "SUN4U-8004-1P.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-1P.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-1P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-1P.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-25 # keys: fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-25.type" msgstr "Fault" msgid "SUN4U-8004-25.severity" msgstr "Critical" msgid "SUN4U-8004-25.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-25.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-25.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-25.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-3S # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-3S.type" msgstr "Fault" msgid "SUN4U-8004-3S.severity" msgstr "Critical" msgid "SUN4U-8004-3S.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-3S.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-3S.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-3S.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-43 # keys: fault.io.datapath fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-43.type" msgstr "Fault" msgid "SUN4U-8004-43.severity" msgstr "Critical" msgid "SUN4U-8004-43.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-43.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-43.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-43.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-5Y # keys: defect.io.pci.driver fault.io.datapath fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-5Y.type" msgstr "Fault" msgid "SUN4U-8004-5Y.severity" msgstr "Critical" msgid "SUN4U-8004-5Y.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-5Y.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-5Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-5Y.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-6D # keys: fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-6D.type" msgstr "Fault" msgid "SUN4U-8004-6D.severity" msgstr "Critical" msgid "SUN4U-8004-6D.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-6D.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-6D.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-6D.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-7H # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-7H.type" msgstr "Fault" msgid "SUN4U-8004-7H.severity" msgstr "Critical" msgid "SUN4U-8004-7H.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-7H.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-7H.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-7H.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-8R # keys: fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-8R.type" msgstr "Fault" msgid "SUN4U-8004-8R.severity" msgstr "Critical" msgid "SUN4U-8004-8R.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-8R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-8R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-8R.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-94 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-94.type" msgstr "Fault" msgid "SUN4U-8004-94.severity" msgstr "Critical" msgid "SUN4U-8004-94.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-94.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-94.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-94.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-AQ # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-AQ.type" msgstr "Fault" msgid "SUN4U-8004-AQ.severity" msgstr "Critical" msgid "SUN4U-8004-AQ.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-AQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-AQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-AQ.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-CC # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-CC.type" msgstr "Fault" msgid "SUN4U-8004-CC.severity" msgstr "Critical" msgid "SUN4U-8004-CC.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-CC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-CC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-CC.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-DJ # keys: fault.io.hbus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-DJ.type" msgstr "Fault" msgid "SUN4U-8004-DJ.severity" msgstr "Critical" msgid "SUN4U-8004-DJ.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-DJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-DJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-DJ.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-EE # keys: defect.io.pci.driver fault.io.hbus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-EE.type" msgstr "Fault" msgid "SUN4U-8004-EE.severity" msgstr "Critical" msgid "SUN4U-8004-EE.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-EE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-EE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-EE.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-FX # keys: fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-FX.type" msgstr "Fault" msgid "SUN4U-8004-FX.severity" msgstr "Critical" msgid "SUN4U-8004-FX.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-FX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-FX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-FX.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-G2 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-G2.type" msgstr "Fault" msgid "SUN4U-8004-G2.severity" msgstr "Critical" msgid "SUN4U-8004-G2.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-G2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-G2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-G2.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-HS # keys: fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-HS.type" msgstr "Fault" msgid "SUN4U-8004-HS.severity" msgstr "Critical" msgid "SUN4U-8004-HS.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-HS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-HS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-HS.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-J5 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-J5.type" msgstr "Fault" msgid "SUN4U-8004-J5.severity" msgstr "Critical" msgid "SUN4U-8004-J5.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-J5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-J5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-J5.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-KP # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-KP.type" msgstr "Fault" msgid "SUN4U-8004-KP.severity" msgstr "Critical" msgid "SUN4U-8004-KP.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-KP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-KP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-KP.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-LA # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-LA.type" msgstr "Fault" msgid "SUN4U-8004-LA.severity" msgstr "Critical" msgid "SUN4U-8004-LA.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-LA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-LA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-LA.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-MH # keys: fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-MH.type" msgstr "Fault" msgid "SUN4U-8004-MH.severity" msgstr "Critical" msgid "SUN4U-8004-MH.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-MH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-MH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-MH.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-ND # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-ND.type" msgstr "Fault" msgid "SUN4U-8004-ND.severity" msgstr "Critical" msgid "SUN4U-8004-ND.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-ND.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-ND.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-ND.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-PY # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-PY.type" msgstr "Fault" msgid "SUN4U-8004-PY.severity" msgstr "Critical" msgid "SUN4U-8004-PY.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-PY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-PY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-PY.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-Q3 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-Q3.type" msgstr "Fault" msgid "SUN4U-8004-Q3.severity" msgstr "Critical" msgid "SUN4U-8004-Q3.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-Q3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-Q3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-Q3.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-RC # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-RC.type" msgstr "Fault" msgid "SUN4U-8004-RC.severity" msgstr "Critical" msgid "SUN4U-8004-RC.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-RC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-RC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-RC.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-SQ # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-SQ.type" msgstr "Fault" msgid "SUN4U-8004-SQ.severity" msgstr "Critical" msgid "SUN4U-8004-SQ.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-SQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-SQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-SQ.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-T4 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-T4.type" msgstr "Fault" msgid "SUN4U-8004-T4.severity" msgstr "Critical" msgid "SUN4U-8004-T4.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-T4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-T4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-T4.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-UR # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.schizo fault.io.xmits # msgid "SUN4U-8004-UR.type" msgstr "Fault" msgid "SUN4U-8004-UR.severity" msgstr "Critical" msgid "SUN4U-8004-UR.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-UR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-UR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-UR.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-V2 # keys: fault.io.psycho # msgid "SUN4U-8004-V2.type" msgstr "Fault" msgid "SUN4U-8004-V2.severity" msgstr "Critical" msgid "SUN4U-8004-V2.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-V2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-V2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-V2.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-WX # keys: defect.io.pci.driver fault.io.psycho # msgid "SUN4U-8004-WX.type" msgstr "Fault" msgid "SUN4U-8004-WX.severity" msgstr "Critical" msgid "SUN4U-8004-WX.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-WX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-WX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-WX.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8004-XE # keys: fault.io.datapath fault.io.psycho # msgid "SUN4U-8004-XE.type" msgstr "Fault" msgid "SUN4U-8004-XE.severity" msgstr "Critical" msgid "SUN4U-8004-XE.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8004-XE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-XE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-XE.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8004-YJ # keys: defect.io.pci.driver fault.io.datapath fault.io.psycho # msgid "SUN4U-8004-YJ.type" msgstr "Fault" msgid "SUN4U-8004-YJ.severity" msgstr "Critical" msgid "SUN4U-8004-YJ.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8004-YJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8004-YJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8004-YJ.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-0E # keys: fault.io.hbus fault.io.psycho # msgid "SUN4U-8005-0E.type" msgstr "Fault" msgid "SUN4U-8005-0E.severity" msgstr "Critical" msgid "SUN4U-8005-0E.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-0E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-0E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-0E.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-1J # keys: defect.io.pci.driver fault.io.hbus fault.io.psycho # msgid "SUN4U-8005-1J.type" msgstr "Fault" msgid "SUN4U-8005-1J.severity" msgstr "Critical" msgid "SUN4U-8005-1J.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-1J.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-1J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-1J.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-22 # keys: fault.io.datapath fault.io.hbus fault.io.psycho # msgid "SUN4U-8005-22.type" msgstr "Fault" msgid "SUN4U-8005-22.severity" msgstr "Critical" msgid "SUN4U-8005-22.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-22.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-22.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-22.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-3X # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.psycho # msgid "SUN4U-8005-3X.type" msgstr "Fault" msgid "SUN4U-8005-3X.severity" msgstr "Critical" msgid "SUN4U-8005-3X.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-3X.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-3X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-3X.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-44 # keys: fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-44.type" msgstr "Fault" msgid "SUN4U-8005-44.severity" msgstr "Critical" msgid "SUN4U-8005-44.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-44.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-44.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-44.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-5R # keys: defect.io.pci.driver fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-5R.type" msgstr "Fault" msgid "SUN4U-8005-5R.severity" msgstr "Critical" msgid "SUN4U-8005-5R.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-5R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-5R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-5R.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-6C # keys: fault.io.datapath fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-6C.type" msgstr "Fault" msgid "SUN4U-8005-6C.severity" msgstr "Critical" msgid "SUN4U-8005-6C.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-6C.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-6C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-6C.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-7Q # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-7Q.type" msgstr "Fault" msgid "SUN4U-8005-7Q.severity" msgstr "Critical" msgid "SUN4U-8005-7Q.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-7Q.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-7Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-7Q.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-8Y # keys: fault.io.hbus fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-8Y.type" msgstr "Fault" msgid "SUN4U-8005-8Y.severity" msgstr "Critical" msgid "SUN4U-8005-8Y.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-8Y.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-8Y.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-8Y.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-93 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-93.type" msgstr "Fault" msgid "SUN4U-8005-93.severity" msgstr "Critical" msgid "SUN4U-8005-93.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-93.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-93.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-93.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-AH # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-AH.type" msgstr "Fault" msgid "SUN4U-8005-AH.severity" msgstr "Critical" msgid "SUN4U-8005-AH.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-AH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-AH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-AH.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-CD # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.psycho # msgid "SUN4U-8005-CD.type" msgstr "Fault" msgid "SUN4U-8005-CD.severity" msgstr "Critical" msgid "SUN4U-8005-CD.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-CD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-CD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-CD.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-DP # keys: fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-DP.type" msgstr "Fault" msgid "SUN4U-8005-DP.severity" msgstr "Critical" msgid "SUN4U-8005-DP.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-DP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-DP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-DP.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-EA # keys: defect.io.pci.driver fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-EA.type" msgstr "Fault" msgid "SUN4U-8005-EA.severity" msgstr "Critical" msgid "SUN4U-8005-EA.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-EA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-EA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-EA.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-FS # keys: fault.io.datapath fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-FS.type" msgstr "Fault" msgid "SUN4U-8005-FS.severity" msgstr "Critical" msgid "SUN4U-8005-FS.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-FS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-FS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-FS.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-G5 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-G5.type" msgstr "Fault" msgid "SUN4U-8005-G5.severity" msgstr "Critical" msgid "SUN4U-8005-G5.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-G5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-G5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-G5.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-HX # keys: fault.io.hbus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-HX.type" msgstr "Fault" msgid "SUN4U-8005-HX.severity" msgstr "Critical" msgid "SUN4U-8005-HX.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-HX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-HX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-HX.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-J2 # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-J2.type" msgstr "Fault" msgid "SUN4U-8005-J2.severity" msgstr "Critical" msgid "SUN4U-8005-J2.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-J2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-J2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-J2.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-KJ # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-KJ.type" msgstr "Fault" msgid "SUN4U-8005-KJ.severity" msgstr "Critical" msgid "SUN4U-8005-KJ.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-KJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-KJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-KJ.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-LE # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-LE.type" msgstr "Fault" msgid "SUN4U-8005-LE.severity" msgstr "Critical" msgid "SUN4U-8005-LE.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-LE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-LE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-LE.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-MQ # keys: fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-MQ.type" msgstr "Fault" msgid "SUN4U-8005-MQ.severity" msgstr "Critical" msgid "SUN4U-8005-MQ.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-MQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-MQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-MQ.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-NC # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-NC.type" msgstr "Fault" msgid "SUN4U-8005-NC.severity" msgstr "Critical" msgid "SUN4U-8005-NC.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-NC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-NC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-NC.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-PR # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-PR.type" msgstr "Fault" msgid "SUN4U-8005-PR.severity" msgstr "Critical" msgid "SUN4U-8005-PR.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-PR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-PR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-PR.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-Q4 # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-Q4.type" msgstr "Fault" msgid "SUN4U-8005-Q4.severity" msgstr "Critical" msgid "SUN4U-8005-Q4.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-Q4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-Q4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-Q4.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-RD # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-RD.type" msgstr "Fault" msgid "SUN4U-8005-RD.severity" msgstr "Critical" msgid "SUN4U-8005-RD.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-RD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-RD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-RD.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-SH # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-SH.type" msgstr "Fault" msgid "SUN4U-8005-SH.severity" msgstr "Critical" msgid "SUN4U-8005-SH.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-SH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-SH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-SH.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-T3 # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-T3.type" msgstr "Fault" msgid "SUN4U-8005-T3.severity" msgstr "Critical" msgid "SUN4U-8005-T3.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-T3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-T3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-T3.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-UY # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.psycho # msgid "SUN4U-8005-UY.type" msgstr "Fault" msgid "SUN4U-8005-UY.severity" msgstr "Critical" msgid "SUN4U-8005-UY.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-UY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-UY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-UY.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-V5 # keys: fault.io.tomatillo # msgid "SUN4U-8005-V5.type" msgstr "Fault" msgid "SUN4U-8005-V5.severity" msgstr "Critical" msgid "SUN4U-8005-V5.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-V5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-V5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-V5.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-WS # keys: defect.io.pci.driver fault.io.tomatillo # msgid "SUN4U-8005-WS.type" msgstr "Fault" msgid "SUN4U-8005-WS.severity" msgstr "Critical" msgid "SUN4U-8005-WS.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-WS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-WS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-WS.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8005-XA # keys: fault.io.datapath fault.io.tomatillo # msgid "SUN4U-8005-XA.type" msgstr "Fault" msgid "SUN4U-8005-XA.severity" msgstr "Critical" msgid "SUN4U-8005-XA.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8005-XA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-XA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-XA.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8005-YP # keys: defect.io.pci.driver fault.io.datapath fault.io.tomatillo # msgid "SUN4U-8005-YP.type" msgstr "Fault" msgid "SUN4U-8005-YP.severity" msgstr "Critical" msgid "SUN4U-8005-YP.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8005-YP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8005-YP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8005-YP.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-04 # keys: fault.io.hbus fault.io.tomatillo # msgid "SUN4U-8006-04.type" msgstr "Fault" msgid "SUN4U-8006-04.severity" msgstr "Critical" msgid "SUN4U-8006-04.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-04.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-04.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-04.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-1R # keys: defect.io.pci.driver fault.io.hbus fault.io.tomatillo # msgid "SUN4U-8006-1R.type" msgstr "Fault" msgid "SUN4U-8006-1R.severity" msgstr "Critical" msgid "SUN4U-8006-1R.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-1R.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-1R.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-1R.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-2C # keys: fault.io.datapath fault.io.hbus fault.io.tomatillo # msgid "SUN4U-8006-2C.type" msgstr "Fault" msgid "SUN4U-8006-2C.severity" msgstr "Critical" msgid "SUN4U-8006-2C.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-2C.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-2C.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-2C.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-3Q # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.tomatillo # msgid "SUN4U-8006-3Q.type" msgstr "Fault" msgid "SUN4U-8006-3Q.severity" msgstr "Critical" msgid "SUN4U-8006-3Q.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-3Q.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-3Q.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-3Q.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-4E # keys: fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-4E.type" msgstr "Fault" msgid "SUN4U-8006-4E.severity" msgstr "Critical" msgid "SUN4U-8006-4E.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-4E.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-4E.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-4E.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-5J # keys: defect.io.pci.driver fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-5J.type" msgstr "Fault" msgid "SUN4U-8006-5J.severity" msgstr "Critical" msgid "SUN4U-8006-5J.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-5J.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-5J.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-5J.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-62 # keys: fault.io.datapath fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-62.type" msgstr "Fault" msgid "SUN4U-8006-62.severity" msgstr "Critical" msgid "SUN4U-8006-62.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-62.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-62.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-62.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-7X # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-7X.type" msgstr "Fault" msgid "SUN4U-8006-7X.severity" msgstr "Critical" msgid "SUN4U-8006-7X.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-7X.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-7X.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-7X.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-8P # keys: fault.io.hbus fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-8P.type" msgstr "Fault" msgid "SUN4U-8006-8P.severity" msgstr "Critical" msgid "SUN4U-8006-8P.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-8P.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-8P.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-8P.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-9A # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-9A.type" msgstr "Fault" msgid "SUN4U-8006-9A.severity" msgstr "Critical" msgid "SUN4U-8006-9A.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-9A.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-9A.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-9A.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-AS # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-AS.type" msgstr "Fault" msgid "SUN4U-8006-AS.severity" msgstr "Critical" msgid "SUN4U-8006-AS.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-AS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-AS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-AS.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-C5 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.tomatillo # msgid "SUN4U-8006-C5.type" msgstr "Fault" msgid "SUN4U-8006-C5.severity" msgstr "Critical" msgid "SUN4U-8006-C5.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-C5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-C5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-C5.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-DY # keys: fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-DY.type" msgstr "Fault" msgid "SUN4U-8006-DY.severity" msgstr "Critical" msgid "SUN4U-8006-DY.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-DY.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-DY.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-DY.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-E3 # keys: defect.io.pci.driver fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-E3.type" msgstr "Fault" msgid "SUN4U-8006-E3.severity" msgstr "Critical" msgid "SUN4U-8006-E3.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-E3.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-E3.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-E3.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-FH # keys: fault.io.datapath fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-FH.type" msgstr "Fault" msgid "SUN4U-8006-FH.severity" msgstr "Critical" msgid "SUN4U-8006-FH.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-FH.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-FH.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-FH.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-GD # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-GD.type" msgstr "Fault" msgid "SUN4U-8006-GD.severity" msgstr "Critical" msgid "SUN4U-8006-GD.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-GD.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-GD.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-GD.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-HQ # keys: fault.io.hbus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-HQ.type" msgstr "Fault" msgid "SUN4U-8006-HQ.severity" msgstr "Critical" msgid "SUN4U-8006-HQ.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-HQ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-HQ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-HQ.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-JC # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-JC.type" msgstr "Fault" msgid "SUN4U-8006-JC.severity" msgstr "Critical" msgid "SUN4U-8006-JC.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-JC.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-JC.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-JC.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-KR # keys: fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-KR.type" msgstr "Fault" msgid "SUN4U-8006-KR.severity" msgstr "Critical" msgid "SUN4U-8006-KR.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-KR.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-KR.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-KR.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-L4 # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-L4.type" msgstr "Fault" msgid "SUN4U-8006-L4.severity" msgstr "Critical" msgid "SUN4U-8006-L4.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-L4.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-L4.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-L4.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-MX # keys: fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-MX.type" msgstr "Fault" msgid "SUN4U-8006-MX.severity" msgstr "Critical" msgid "SUN4U-8006-MX.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-MX.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-MX.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-MX.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-N2 # keys: defect.io.pci.driver fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-N2.type" msgstr "Fault" msgid "SUN4U-8006-N2.severity" msgstr "Critical" msgid "SUN4U-8006-N2.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-N2.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-N2.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-N2.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-PJ # keys: fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-PJ.type" msgstr "Fault" msgid "SUN4U-8006-PJ.severity" msgstr "Critical" msgid "SUN4U-8006-PJ.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-PJ.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-PJ.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-PJ.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-QE # keys: defect.io.pci.driver fault.io.datapath fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-QE.type" msgstr "Fault" msgid "SUN4U-8006-QE.severity" msgstr "Critical" msgid "SUN4U-8006-QE.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-QE.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-QE.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-QE.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-R5 # keys: fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-R5.type" msgstr "Fault" msgid "SUN4U-8006-R5.severity" msgstr "Critical" msgid "SUN4U-8006-R5.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-R5.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-R5.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-R5.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-SS # keys: defect.io.pci.driver fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-SS.type" msgstr "Fault" msgid "SUN4U-8006-SS.severity" msgstr "Critical" msgid "SUN4U-8006-SS.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-SS.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-SS.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-SS.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-TA # keys: fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-TA.type" msgstr "Fault" msgid "SUN4U-8006-TA.severity" msgstr "Critical" msgid "SUN4U-8006-TA.description" msgstr "\n\nA problem was detected in a system core bus.\n Refer to %s for more information." msgid "SUN4U-8006-TA.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-TA.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-TA.action" msgstr "\n\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4U-8006-UP # keys: defect.io.pci.driver fault.io.datapath fault.io.hbus fault.io.pci.bus fault.io.pci.device fault.io.tomatillo # msgid "SUN4U-8006-UP.type" msgstr "Fault" msgid "SUN4U-8006-UP.severity" msgstr "Critical" msgid "SUN4U-8006-UP.description" msgstr "\n\nThe system has diagnosed a problem, the suspects include one or more \nPCI buses, devices and one or more PCI controller drivers, based on the \nerror telemetry detected by the PCI subsystem.\n Refer to %s for more information." msgid "SUN4U-8006-UP.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8006-UP.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8006-UP.action" msgstr "\n\nUse fmdump -v -u to identify the \nsuspected device(s). Schedule a repair of the most likely suspect \nlisted in the output. If the most likely suspect is a package then run \npkgchk on the package(s).\n" # # code: SUN4U-8006-VD # keys: fault.cpu.ultraSPARC-IIIiplus.dcache # msgid "SUN4U-8006-VD.type" msgstr "Fault" msgid "SUN4U-8006-VD.severity" msgstr "Major" msgid "SUN4U-8006-VD.description" msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8006-VD.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8006-VD.impact" msgstr "System performance may be affected." msgid "SUN4U-8006-VD.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8006-WH # keys: fault.cpu.ultraSPARC-IIIiplus.icache # msgid "SUN4U-8006-WH.type" msgstr "Fault" msgid "SUN4U-8006-WH.severity" msgstr "Major" msgid "SUN4U-8006-WH.description" msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8006-WH.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8006-WH.impact" msgstr "System performance may be affected." msgid "SUN4U-8006-WH.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8006-X3 # keys: fault.cpu.ultraSPARC-IIIiplus.l2cachedata # msgid "SUN4U-8006-X3.type" msgstr "Fault" msgid "SUN4U-8006-X3.severity" msgstr "Major" msgid "SUN4U-8006-X3.description" msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8006-X3.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8006-X3.impact" msgstr "System performance may be affected." msgid "SUN4U-8006-X3.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8006-YY # keys: fault.cpu.ultraSPARC-IIIiplus.l2cachetag # msgid "SUN4U-8006-YY.type" msgstr "Fault" msgid "SUN4U-8006-YY.severity" msgstr "Major" msgid "SUN4U-8006-YY.description" msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8006-YY.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8006-YY.impact" msgstr "System performance may be affected." msgid "SUN4U-8006-YY.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8007-03 # keys: fault.cpu.ultraSPARC-IIIiplus.fpu # msgid "SUN4U-8007-03.type" msgstr "Fault" msgid "SUN4U-8007-03.severity" msgstr "Major" msgid "SUN4U-8007-03.description" msgstr "The number of errors associated with a CPU has exceeded acceptable levels. Refer to %s for more information." msgid "SUN4U-8007-03.response" msgstr "The fault manager will attempt to remove the affected CPU from service." msgid "SUN4U-8007-03.impact" msgstr "System performance may be affected." msgid "SUN4U-8007-03.action" msgstr "Schedule a repair procedure to replace the affected CPU, the identity of which can be determined using fmdump -v -u ." # # code: SUN4U-8007-1Y # keys: fault.asic.cds.dp # msgid "SUN4U-8007-1Y.type" msgstr "Fault" msgid "SUN4U-8007-1Y.severity" msgstr "Critical" msgid "SUN4U-8007-1Y.description" msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." msgid "SUN4U-8007-1Y.response" msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" msgid "SUN4U-8007-1Y.impact" msgstr "System performace may be affected.\n" msgid "SUN4U-8007-1Y.action" msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative.\n" # # code: SUN4U-8007-2D # keys: fault.asic.dx.dp # msgid "SUN4U-8007-2D.type" msgstr "Fault" msgid "SUN4U-8007-2D.severity" msgstr "Critical" msgid "SUN4U-8007-2D.description" msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." msgid "SUN4U-8007-2D.response" msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" msgid "SUN4U-8007-2D.impact" msgstr "System performace may be affected.\n" msgid "SUN4U-8007-2D.action" msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative.\n" # # code: SUN4U-8007-3H # keys: fault.asic.sdi.dp # msgid "SUN4U-8007-3H.type" msgstr "Fault" msgid "SUN4U-8007-3H.severity" msgstr "Critical" msgid "SUN4U-8007-3H.description" msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." msgid "SUN4U-8007-3H.response" msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" msgid "SUN4U-8007-3H.impact" msgstr "System performace may be affected.\n" msgid "SUN4U-8007-3H.action" msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative.\n" # # code: SUN4U-8007-4A # keys: fault.asic.cp.dp # msgid "SUN4U-8007-4A.type" msgstr "Fault" msgid "SUN4U-8007-4A.severity" msgstr "Critical" msgid "SUN4U-8007-4A.description" msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." msgid "SUN4U-8007-4A.response" msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" msgid "SUN4U-8007-4A.impact" msgstr "System performace may be affected.\n" msgid "SUN4U-8007-4A.action" msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative.\n" # # code: SUN4U-8007-5P # keys: fault.asic.rp.dp # msgid "SUN4U-8007-5P.type" msgstr "Fault" msgid "SUN4U-8007-5P.severity" msgstr "Critical" msgid "SUN4U-8007-5P.description" msgstr "A hardware problem was detected on the datapath interconnect.\n Refer to %s for more information." msgid "SUN4U-8007-5P.response" msgstr "One or more CPUs may be offlined. Additionally, page retires for memory in the impacted region may be disabled.\n" msgid "SUN4U-8007-5P.impact" msgstr "System performace may be affected.\n" msgid "SUN4U-8007-5P.action" msgstr "Schedule a repair procedure to replace the affected component(s). The System Controller (SC) diagnostic messages have the authoritative information on the affected component(s). fmdump -v -u can also be used, but the SC is authoritative.\n" # # code: SUN4U-8007-65 # keys: fault.io.oberon # msgid "SUN4U-8007-65.type" msgstr "Fault" msgid "SUN4U-8007-65.severity" msgstr "Critical" msgid "SUN4U-8007-65.description" msgstr "Oberon PCI-Express hostbridge fault\n Refer to %s for more information." msgid "SUN4U-8007-65.response" msgstr "This fault requires user and/or service interaction and currently does not have an automated response agent." msgid "SUN4U-8007-65.impact" msgstr "Possible loss of devices that may be attached to the system via this device/bus and/or system downtime." msgid "SUN4U-8007-65.action" msgstr "Ensure that the latest drivers and patches are installed, schedule a repair procedure to replace the affected device if necessary, or contact Sun for support." # # code: SUN4U-8007-7S # keys: fault.cpu.SPARC64-VI.chip # msgid "SUN4U-8007-7S.type" msgstr "Fault" msgid "SUN4U-8007-7S.severity" msgstr "Critical" msgid "SUN4U-8007-7S.description" msgstr "The number of errors associated with this CHIP has exceeded acceptable levels.\nRefer to %s for more information.\n Refer to %s for more information." msgid "SUN4U-8007-7S.response" msgstr "An attempt will be made to remove the affected CHIP from service.\n" msgid "SUN4U-8007-7S.impact" msgstr "The system will not be functioning at the same performance level with the CHIP removal.\n" msgid "SUN4U-8007-7S.action" msgstr "Schedule a repair procedure to replace the affected CHIP. Use fmdump -v -u\n to identify the smallest CPU/Strand ID of the affected CORE on this\nCHIP.\n" # # code: SUN4U-8007-8J # keys: fault.cpu.SPARC64-VI.core # msgid "SUN4U-8007-8J.type" msgstr "Fault" msgid "SUN4U-8007-8J.severity" msgstr "Critical" msgid "SUN4U-8007-8J.description" msgstr "The number of errors associated with this CHIP has exceeded acceptable levels.\nRefer to %s for more information.\n Refer to %s for more information." msgid "SUN4U-8007-8J.response" msgstr "An attempt will be made to remove the affected CORE from service.\n" msgid "SUN4U-8007-8J.impact" msgstr "The system will not be functioning at the same performance level with the CORE removal.\n" msgid "SUN4U-8007-8J.action" msgstr "Schedule a repair procedure to replace the affected CORE. Use fmdump -v -u\n to identify the smallest CPU/Strand ID of the affected CORE on this\nCORE.\n" # # code: SUN4U-8007-9E # keys: fault.cpu.SPARC64-VI.strand # msgid "SUN4U-8007-9E.type" msgstr "Fault" msgid "SUN4U-8007-9E.severity" msgstr "Critical" msgid "SUN4U-8007-9E.description" msgstr "The number of errors associated with this STRAND has exceeded acceptable levels.\nRefer to %s for more information.\n Refer to %s for more information." msgid "SUN4U-8007-9E.response" msgstr "An attempt will be made to remove the affected STRAND from service.\n" msgid "SUN4U-8007-9E.impact" msgstr "The system will not be functioning at the same performance level with the STRAND removal.\n" msgid "SUN4U-8007-9E.action" msgstr "Schedule a repair procedure to replace the affected STRAND. Use fmdump -v -u\n to identify the smallest CPU/Strand ID of the affected CORE on this\nSTRAND.\n" # # code: SUN4U-8007-AX # keys: fault.io.pci.device-invreq fault.io.tomatillo # msgid "SUN4U-8007-AX.type" msgstr "Fault" msgid "SUN4U-8007-AX.severity" msgstr "Critical" msgid "SUN4U-8007-AX.description" msgstr "Either the transmitting device sent an invalid request or the receiving device failed to respond.\n Refer to %s for more information." msgid "SUN4U-8007-AX.response" msgstr "One or more device instances may be disabled\n" msgid "SUN4U-8007-AX.impact" msgstr "Loss of services provided by the device instances associated with this fault\n" msgid "SUN4U-8007-AX.action" msgstr "Ensure that the latest drivers and patches are installed. If a plug-in card is involved check for badly-seated cards or bent pins. Otherwise schedule a repair procedure to replace the affected device(s). Use fmdump -v -u to identify the devices or contact Sun for support.\n"