# # Copyright 2005 Sun Microsystems, Inc. All rights reserved. # Use is subject to license terms. # # CDDL HEADER START # # The contents of this file are subject to the terms of the # Common Development and Distribution License, Version 1.0 only # (the "License"). You may not use this file except in compliance # with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. # See the License for the specific language governing permissions # and limitations under the License. # # When distributing Covered Code, include this CDDL HEADER in each # file and include the License file at usr/src/OPENSOLARIS.LICENSE. # If applicable, add the following below this CDDL HEADER, with the # fields enclosed by brackets "[]" replaced with your own identifying # information: Portions Copyright [yyyy] [name of copyright owner] # # CDDL HEADER END # #ident "%Z%%M% %I% %E% SMI" # # # code: SUN4-8000-0Y # keys: fault.io.fire.asic # msgid "SUN4-8000-0Y.type" msgstr "Fault" msgid "SUN4-8000-0Y.severity" msgstr "Critical" msgid "SUN4-8000-0Y.description" msgstr "\nA problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." msgid "SUN4-8000-0Y.response" msgstr "One or more device instances may be disabled" msgid "SUN4-8000-0Y.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-0Y.action" msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4-8000-13 # keys: fault.io.ebus # msgid "SUN4-8000-13.type" msgstr "Fault" msgid "SUN4-8000-13.severity" msgstr "Critical" msgid "SUN4-8000-13.description" msgstr "\nA problem was detected in the system core bus.\n Refer to %s for more information." msgid "SUN4-8000-13.response" msgstr "One or more device instances may be disabled" msgid "SUN4-8000-13.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-13.action" msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4-8000-2H # keys: fault.io.datapath # msgid "SUN4-8000-2H.type" msgstr "Fault" msgid "SUN4-8000-2H.severity" msgstr "Critical" msgid "SUN4-8000-2H.description" msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." msgid "SUN4-8000-2H.response" msgstr "None" msgid "SUN4-8000-2H.impact" msgstr "None" msgid "SUN4-8000-2H.action" msgstr "None" # # code: SUN4-8000-3D # keys: fault.io.hbus # msgid "SUN4-8000-3D.type" msgstr "Fault" msgid "SUN4-8000-3D.severity" msgstr "Critical" msgid "SUN4-8000-3D.description" msgstr "\nA problem was detected in the system core bus.\n Refer to %s for more information." msgid "SUN4-8000-3D.response" msgstr "One or more device instances may be disabled" msgid "SUN4-8000-3D.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-3D.action" msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4-8000-4P # keys: fault.io.fire.pciex.device # msgid "SUN4-8000-4P.type" msgstr "Fault" msgid "SUN4-8000-4P.severity" msgstr "Critical" msgid "SUN4-8000-4P.description" msgstr "\nA problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." msgid "SUN4-8000-4P.response" msgstr "One or more device instances may be disabled" msgid "SUN4-8000-4P.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-4P.action" msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4-8000-5A # keys: defect.io.fire.pciex.driver # msgid "SUN4-8000-5A.type" msgstr "Defect" msgid "SUN4-8000-5A.severity" msgstr "Critical" msgid "SUN4-8000-5A.description" msgstr "\nA problem was detected in the PCI-Express subsystem software.\n Refer to %s for more information." msgid "SUN4-8000-5A.response" msgstr "One or more device instances may be disabled" msgid "SUN4-8000-5A.impact" msgstr "Loss of services provided by the device instances associated with\nthis problem" msgid "SUN4-8000-5A.action" msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u to identify the module/package, or contact Sun for support." # # code: SUN4-8000-6S # keys: fault.io.datapath fault.io.fire.asic # msgid "SUN4-8000-6S.type" msgstr "Fault" msgid "SUN4-8000-6S.severity" msgstr "Critical" msgid "SUN4-8000-6S.description" msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." msgid "SUN4-8000-6S.response" msgstr "None" msgid "SUN4-8000-6S.impact" msgstr "None" msgid "SUN4-8000-6S.action" msgstr "None" # # code: SUN4-8000-75 # keys: fault.io.fire.asic fault.io.fire.pciex.device # msgid "SUN4-8000-75.type" msgstr "Fault" msgid "SUN4-8000-75.severity" msgstr "Critical" msgid "SUN4-8000-75.description" msgstr "\nA problem was detected in the PCI-Express subsystem.\n Refer to %s for more information." msgid "SUN4-8000-75.response" msgstr "One or more device instances may be disabled" msgid "SUN4-8000-75.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-75.action" msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4-8000-8E # keys: defect.io.fire.pci.driver defect.io.fire.pciex.driver # msgid "SUN4-8000-8E.type" msgstr "Defect" msgid "SUN4-8000-8E.severity" msgstr "Critical" msgid "SUN4-8000-8E.description" msgstr "\nA problem was detected in the PCI-Express subsystem software.\n Refer to %s for more information." msgid "SUN4-8000-8E.response" msgstr "One or more device instances may be disabled" msgid "SUN4-8000-8E.impact" msgstr "Loss of services provided by the device instances associated with this problem" msgid "SUN4-8000-8E.action" msgstr "Ensure latest driver and patch are installed. Use fmdump -v -u to identify the module/package, or contact Sun for support." # # code: SUN4-8000-9J # keys: fault.io.fire.pci.device fault.io.fire.pciex.device # msgid "SUN4-8000-9J.type" msgstr "Fault" msgid "SUN4-8000-9J.severity" msgstr "Critical" msgid "SUN4-8000-9J.description" msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." msgid "SUN4-8000-9J.response" msgstr "None" msgid "SUN4-8000-9J.impact" msgstr "None" msgid "SUN4-8000-9J.action" msgstr "None" # # code: SUN4-8000-A2 # keys: fault.io.fire.pci.device # msgid "SUN4-8000-A2.type" msgstr "Fault" msgid "SUN4-8000-A2.severity" msgstr "Critical" msgid "SUN4-8000-A2.description" msgstr "\nA problem was detected in the PCI subsystem.\n Refer to %s for more information." msgid "SUN4-8000-A2.response" msgstr "One or more device instances may be disabled" msgid "SUN4-8000-A2.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-A2.action" msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4-8000-CX # keys: defect.io.fire.pciex.driver fault.io.datapath fault.io.fire.asic # msgid "SUN4-8000-CX.type" msgstr "Fault" msgid "SUN4-8000-CX.severity" msgstr "Critical" msgid "SUN4-8000-CX.description" msgstr "This is an unexpected diagnosis. Please contact Sun support for details. Refer to %s for more information." msgid "SUN4-8000-CX.response" msgstr "None" msgid "SUN4-8000-CX.impact" msgstr "None" msgid "SUN4-8000-CX.action" msgstr "None" # # code: SUN4-8000-D4 # keys: fault.io.fire.asic fault.io.fire.pci.device fault.io.fire.pciex.device # msgid "SUN4-8000-D4.type" msgstr "Fault" msgid "SUN4-8000-D4.severity" msgstr "Critical" msgid "SUN4-8000-D4.description" msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information." msgid "SUN4-8000-D4.response" msgstr "One or more device instances may be disabled" msgid "SUN4-8000-D4.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-D4.action" msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n" # # code: SUN4-8000-ER # keys: fault.io.fire.asic fault.io.fire.pci.device # msgid "SUN4-8000-ER.type" msgstr "Fault" msgid "SUN4-8000-ER.severity" msgstr "Critical" msgid "SUN4-8000-ER.description" msgstr "A problem has been detected in the PCI/PCI-Express subsystem. Refer to %s for more information." msgid "SUN4-8000-ER.response" msgstr "One or more device instances may be disabled" msgid "SUN4-8000-ER.impact" msgstr "Loss of services provided by the device instances associated with this fault" msgid "SUN4-8000-ER.action" msgstr "\nSchedule a repair procedure to replace the affected device. Use\nfmdump -v -u EVENT_ID to identify the device or contact\nSun for support.\n"