'\" te
.\"  Copyright (c) 2008, Sun Microsystems, Inc. All Rights Reserved
.\" The contents of this file are subject to the terms of the Common Development and Distribution License (the "License").  You may not use this file except in compliance with the License.
.\" You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE or http://www.opensolaris.org/os/licensing.  See the License for the specific language governing permissions and limitations under the License.
.\" When distributing Covered Code, include this CDDL HEADER in each file and include the License file at usr/src/OPENSOLARIS.LICENSE.  If applicable, add the following below this CDDL HEADER, with the fields enclosed by brackets "[]" replaced with your own identifying information: Portions Copyright [yyyy] [name of copyright owner]
.TH audit_syslog 5 "25 Sep 2008" "SunOS 5.11" "Standards, Environments, and Macros"
.SH NAME
audit_syslog \- realtime conversion of Solaris audit data to syslog messages
.SH SYNOPSIS
.LP
.nf
\fB/usr/lib/security/audit_syslog.so\fR
.fi

.SH DESCRIPTION
.sp
.LP
The \fBaudit_syslog\fR plugin module for Solaris audit,
\fB/usr/lib/security/audit_syslog.so\fR, provides realtime conversion of
Solaris audit data to syslog-formatted (text) data and sends it to a syslog
daemon as configured in \fBsyslog.conf\fR(4). The plugin's path is specified in
the audit configuration file, \fBaudit_control\fR(4).
.sp
.LP
Messages to \fBsyslog\fR are written if selected via the \fBplugin\fR option in
\fBaudit_control\fR. Syslog messages are generated with the facility code of
\fBLOG_AUDIT\fR (\fBaudit\fR in \fBsyslog.conf\fR(4)) and severity of
\fBLOG_NOTICE\fR. Audit \fBsyslog\fR messages contain data selected from the
tokens described for the binary audit log. (See \fBaudit.log\fR(4)). As with
all \fBsyslog\fR messages, each line in a \fBsyslog\fR file consists of two
parts, a \fBsyslog\fR header and a message.
.sp
.LP
The syslog header contains the date and time the message was generated, the
host name from which it was sent, \fBauditd\fR to indicate that it was
generated by the audit daemon, an ID field used internally by \fBsyslogd\fR,
and \fBaudit.notice\fR indicating the \fBsyslog\fR facility and severity
values. The \fBsyslog\fR header ends with the characters \fB]\fR, that is, a
closing square bracket and a space.
.sp
.LP
The message part starts with the event type from the header token. All
subsequent data appears only if contained in the original audit record and
there is room in the 1024-byte maximum length \fBsyslog\fR line. In the
following example, the backslash (\fB\e\fR) indicates a continuation; actual
\fBsyslog\fR messages are contained on one line:
.sp
.in +2
.nf
Oct 31 11:38:08 smothers auditd: [ID 917521 audit.notice] chdir(2) ok\e
session 401 by joeuser as root:other from myultra obj /export/home
.fi
.in -2
.sp

.sp
.LP
In the preceding example, \fBchdir(2)\fR is the event type. Following this
field is additional data, described below. This data is omitted if it is not
contained in the source audit record.
.sp
.ne 2
.mk
.na
\fB\fBok\fR or \fBfailed\fR\fR
.ad
.RS 21n
.rt  
Comes from the return or exit token.
.RE

.sp
.ne 2
.mk
.na
\fB\fBsession \fI<#>\fR\fR\fR
.ad
.RS 21n
.rt  
\fI<#>\fR is the session ID from the subject token.
.RE

.sp
.ne 2
.mk
.na
\fB\fBby \fI<name>\fR\fR\fR
.ad
.RS 21n
.rt  
\fI<name>\fR is the audit ID from the subject token.
.RE

.sp
.ne 2
.mk
.na
\fB\fBas \fI<name>\fR:\fI<group>\fR\fR\fR
.ad
.RS 21n
.rt  
\fI<name>\fR is the effective user ID and \fI<group>\fR is the effective group
ID from the subject token.
.RE

.sp
.ne 2
.mk
.na
\fB\fBin\fR \fI<zone name>\fR\fR
.ad
.RS 21n
.rt  
The zone name. This field is generated only if the \fBzonename\fR audit policy
is set.
.RE

.sp
.ne 2
.mk
.na
\fB\fBfrom \fI<terminal>\fR\fR\fR
.ad
.RS 21n
.rt  
\fI<terminal>\fR is the text machine address from the subject token.
.RE

.sp
.ne 2
.mk
.na
\fB\fBobj \fI<path>\fR\fR\fR
.ad
.RS 21n
.rt  
\fI<path>\fR is the path from the path token The path can be truncated from the
left if necessary to fit it on the line. Truncation is indicated by leading
ellipsis (\fB\&...\fR).
.RE

.sp
.ne 2
.mk
.na
\fB\fBproc_uid \fI<owner>\fR\fR\fR
.ad
.RS 21n
.rt  
\fI<owner>\fR is the effective user ID of the process owner.
.RE

.sp
.ne 2
.mk
.na
\fB\fBproc_auid \fI<owner>\fR\fR\fR
.ad
.RS 21n
.rt  
\fI<owner>\fR is the audit ID of the process owner.
.RE

.sp
.LP
The following are example \fBsyslog\fR messages:
.sp
.in +2
.nf
Nov  4  8:27:07 smothers auditd: [ID 175219 audit.notice] \e
system booted

Nov  4  9:28:17 smothers auditd: [ID 752191 audit.notice] \e
login - rlogin ok session 401 by joeuser as joeuser:staff from myultra

Nov  4 10:29:27 smothers auditd: [ID 521917 audit.notice] \e
access(2) ok session 255 by janeuser as janeuser:staff from  \e
129.146.89.30 obj /etc/passwd
.fi
.in -2
.sp

.SH OBJECT ATTRIBUTES
.sp
.LP
The \fBp_flag\fR attribute, specified by means of the \fBplugin\fR directive
(see \fBaudit_control\fR(4)), is used to further filter audit data being sent
to the \fBsyslog\fR daemon beyond the classes specified through the \fBflags\fR
and \fBnaflags\fR lines of \fBaudit_control\fR and through the user-specific
lines of \fBaudit_user\fR(4). The parameter is a comma-separated list; each
item represents an audit class (see \fBaudit_class\fR(4)) and is specified
using the same syntax used in \fBaudit_control\fR for the \fBflags\fR and
\fBnaflags\fR lines. The default (no \fBp_flags\fR listed) is that no audit
records are generated.
.SH EXAMPLES
.LP
\fBExample 1 \fROne Use of the \fBplugin\fR Line
.sp
.LP
In the specification shown below, the \fBplugin\fR line (in conjunction with
\fBflags\fR and \fBnaflags\fR) is used to allow class records for \fBlo\fR but
allows class records for \fBam\fR for failures only. Omission of the \fBfm\fR
class records results in no \fBfm\fR class records being output. The \fBpc\fR
parameter has no effect because you cannot add classes to those defined by
means of \fBflags\fR and \fBnaflags\fR and by \fBaudit_user\fR(4). You can only
remove them.

.sp
.in +2
.nf
flags: lo,am,fm
naflags: lo
plugin: name=audit_syslog.so; p_flags=lo,-am
.fi
.in -2
.sp

.LP
\fBExample 2 \fRUse of \fBall\fR
.sp
.LP
In the specification shown below, with one exception, \fBall\fR allows all
flags defined by means of \fBflags\fR and \fBnaflags\fR (and
\fBaudit_user\fR(4)). The exception the \fBam\fR metaclass, which is equivalent
to \fBss,as,ua\fR, which is modified to output all \fBua\fR events but only
failure events for \fBss\fR and \fBas\fR.

.sp
.in +2
.nf
flags: lo,am
naflags: lo
plugin: name=audit_syslog.so; p_flags=all,^+ss,^+as
.fi
.in -2
.sp

.SH ATTRIBUTES
.sp
.LP
See \fBattributes\fR(5) for a description of the following attributes:
.sp

.sp
.TS
tab() box;
cw(2.75i) |cw(2.75i) 
lw(2.75i) |lw(2.75i) 
.
\fBATTRIBUTE TYPE\fR\fBATTRIBUTE VALUE\fR
_
MT LevelMT-Safe
_
Interface StabilitySee below.
.TE

.sp
.LP
The message format and message content are Uncommitted. The configuration
parameters are Committed.
.SH SEE ALSO
.sp
.LP
\fBauditd\fR(1M), \fBaudit_class\fR(4), \fBaudit_control\fR(4),
\fBsyslog.conf\fR(4), \fBattributes\fR(5)
.sp
.LP
\fISystem Administration Guide: Security Services\fR
.SH NOTES
.sp
.LP
Use of the \fBplugin\fR configuration line to include \fBaudit_syslog.so\fR
requires that \fB/etc/syslog.conf\fR is configured to store \fBsyslog\fR
messages of facility \fBaudit\fR and severity \fBnotice\fR or above in a file
intended for Solaris audit records. An example of such a line in
\fBsyslog.conf\fR is:
.sp
.in +2
.nf
audit.notice                /var/audit/audit.log
.fi
.in -2
.sp

.sp
.LP
Messages from \fBsyslog\fR are sent to remote \fBsyslog\fR servers by means of
UDP, which does not guarantee delivery or ensure the correct order of arrival
of messages.
.sp
.LP
If the parameters specified for the \fBplugin\fR line result in no classes
being preselected, an error is reported by means of a \fBsyslog\fR alert with
the \fBLOG_DAEMON\fR facility code.
.sp
.LP
The time field in the \fBsyslog\fR header is generated by \fBsyslog\fR(3C) and
only approximates the time given in the binary audit log. Normally the time