.\" .\" This file and its contents are supplied under the terms of the .\" Common Development and Distribution License ("CDDL"), version 1.0. .\" You may only use this file in accordance with the terms of version .\" 1.0 of the CDDL. .\" .\" A full copy of the text of the CDDL should have accompanied this .\" source. A copy of the CDDL is also available via the Internet at .\" http://www.illumos.org/license/CDDL. .\" .\" .\" Copyright (c) 2012, Joyent, Inc. All Rights Reserved .\" Copyright (c) 2013, 2017 by Delphix. All rights reserved. .\" Copyright (c) 2016-2017, Chris Fraire . .\" Copyright 2024 OmniOS Community Edition (OmniOSce) Association. .\" Copyright 2021 Tintri by DDN, Inc. All rights reserved. .\" .Dd January 14, 2024 .Dt IPADM 8 .Os .Sh NAME .Nm ipadm .Nd configure IP and IPMP interfaces, addresses and protocols .Sh SYNOPSIS .Nm .Cm help .Nm .Cm create-if .Op Fl t .Ar interface .Nm .Cm create-ip .Op Fl t .Ar interface .Nm .Cm delete-if .Ar interface .Nm .Cm delete-ip .Ar interface .Pp .Nm .Cm create-ipmp .Op Fl t .Op Fl i Ar interface Ns Oo , Ns Ar interface Oc Ns ... .Ar ipmp-interface .Nm .Cm delete-ipmp .Ar ipmp-interface .Nm .Cm add-ipmp .Op Fl t .Fl i Ar interface Ns Oo , Ns Ar interface Oc Ns ... .Ar ipmp-interface .Nm .Cm remove-ipmp .Op Fl t .Fl i Ar interface Ns Oo , Ns Ar interface Oc Ns ... .Ar ipmp-interface .Pp .Nm .Cm disable-if .Fl t .Ar interface .Nm .Cm enable-if .Fl t .Ar interface .Nm .Cm show-if .Op Oo Fl p Oc Fl o Ar field Ns Oo , Ns Ar field Oc Ns ... .Op Ar interface .Pp .Nm .Cm set-ifprop .Op Fl t .Fl p Ar prop Ns = Ns Ar value Ns Oo , Ns Ar value Oc Ns ... .Fl m Ar protocol .Ar interface .Nm .Cm reset-ifprop .Op Fl t .Fl p Ar prop .Fl m Ar protocol .Ar interface .Nm .Cm show-ifprop .Op Oo Fl c Oc Fl o Ar field Ns Oo , Ns Ar value Oc Ns ... .Op Fl p Ar prop Ns Oo , Ns Ar prop Oc Ns ... .Op Fl m Ar protocol .Op Ar interface .Pp .Nm .Cm create-addr .Op Fl t .Fl T Cm static .Op Fl d .Fl a Oo Cm local Ns | Ns Cm remote Ns = Oc Ns .Ar addr Ns Oo / Ns Ar prefixlen Oc Ns ... .Ar addrobj .Nm .Cm create-addr .Op Fl t .Fl T Cm dhcp .Op Fl 1 .Op Fl h Ar hostname .Op Fl w Bro Ar seconds Ns | Ns Cm forever Brc .Ar addrobj .Nm .Cm create-addr .Op Fl t .Fl T Cm addrconf .Op Fl i Ar interface-id .Oo Fl p Bro Cm stateful Ns | Ns Cm stateless Brc Ns = Ns .Bro Cm yes Ns | Ns Cm no Brc Oc Ns ... .Ar addrobj .Nm .Cm delete-addr .Op Fl r .Ar addrobj .Nm .Cm show-addr .Op Oo Fl p Oc Fl o Ar field Ns Oo , Ns Ar field Oc Ns ... .Op Ar addrobj | interface Ns No / .Nm .Cm refresh-addr .Op Fl i .Ar addrobj .Nm .Cm down-addr .Op Fl t .Ar addrobj .Nm .Cm up-addr .Op Fl t .Ar addrobj .Nm .Cm disable-addr .Op Fl t .Ar addrobj .Nm .Cm enable-addr .Op Fl t .Ar addrobj .Pp .Nm .Cm set-addrprop .Op Fl t .Fl p Ar prop Ns = Ns Ar value Ns Oo , Ns Ar value Oc Ns ... .Ar addrobj .Nm .Cm reset-addrprop .Op Fl t .Fl p Ar prop .Ar addrobj .Nm .Cm show-addrprop .Op Oo Fl c Oc Fl o Ar field Ns Oo , Ns Ar field Oc Ns ... .Op Fl p Ar prop Ns Oo , Ns Ar prop Oc Ns ... .Op Ar addrobj | interface Ns No / .Pp .Nm .Cm set-prop .Op Fl t .Fl p Ar prop Ns Oo Cm + Ns | Ns Cm - Oc Ns = Ns .Ar value Ns Oo , Ns Ar value Oc Ns ... .Ar protocol .Nm .Cm reset-prop .Op Fl t .Fl p Ar prop .Ar protocol .Nm .Cm show-prop .Op Oo Fl c Oc Fl o Ar field Ns Oo , Ns Ar field Oc Ns ... .Op Fl p Ar prop Ns Oo , Ns Ar prop Oc Ns ... .Op Ar protocol .Sh DESCRIPTION The .Nm command is a stable replacement for the .Xr ifconfig 8 and .Xr ndd 8 commands. It is used to create IP interfaces and to configure IP addresses on those interfaces. It is also used to get, set or reset properties on interfaces, addresses and protocols. .Pp For subcommands that take an .Em addrobj , the .Em addrobj specifies a unique address on the system, and must be unique itself. It is made up of two parts, delimited by a .Sq / . The first part is the name of the interface and the second part is an arbitrary string up to 32 alphanumeric characters long, where the first character must be alphabetic .Pq e.g. a-z,A-Z . For example, .Qq lo0/v4 is a loopback interface .Em addrobj name, which could also be called .Qq lo0/ipv4loopback . Consumers should note that this length limit may be lifted in the future. .Pp For subcommands that take a .Em protocol , this can be one of the following values: .Cm ip , .Cm ipv4 , .Cm ipv6 , .Cm icmp , .Cm tcp , .Cm sctp or .Cm udp . .Sh SUBCOMMANDS When invoked with no arguments, .Nm shows the current address properties, in the same way as .Nm .Cm show-addr . .Pp The following subcommands are supported: .Pp .Bl -tag -compact -width Ds .It Xo .Nm .Cm help .Xc Display brief command usage. .Pp .It Xo .Nm .Cm create-if .Op Fl t .Ar interface .Xc .It Xo .Nm .Cm create-ip .Op Fl t .Ar interface .Xc Create an IP interface that will handle both IPv4 and IPv6 packets. The interface will be enabled as part of the creation process. The IPv4 interface will have the address 0.0.0.0. The IPv6 interface will have the address ::. The subcommands .Cm create-if and .Cm create-ip are functionally equivalent aliases of each other. .Bl -tag -width Ds .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm delete-if .Ar interface .Xc .It Xo .Nm .Cm delete-ip .Ar interface .Xc Permanently delete the specified IP interface. The subcommands .Cm delete-if and .Cm delete-ip are functionally equivalent aliases of each other. .Pp .It Xo .Nm .Cm create-ipmp .Op Fl t .Op Fl i Ar interface Ns Oo , Ns Ar interface Oc Ns ... .Ar ipmp-interface .Xc Create an IPMP interface that will handle both IPv4 and IPv6 packets. The interface will be enabled as part of the creation process. The IPv4 interface will have the address 0.0.0.0. The IPv6 interface will have the address ::. .Bl -tag -width Ds .It Fl i Ns \&, Ns Fl -interface Interface(s) to be added to the new IPMP interface. .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm delete-ipmp .Ar ipmp-interface .Xc Permanently delete the IPMP interface. .Pp .It Xo .Nm .Cm add-ipmp .Op Fl t .Fl i Ar interface Ns Oo , Ns Ar interface Oc Ns ... .Ar ipmp-interface .Xc Add the IP interface(s) to the IPMP interface. .Bl -tag -width "" .It Fl i Ns \&, Ns Fl -interface Interface(s) to be added to the IPMP interface. .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm remove-ipmp .Op Fl t .Fl i Ar interface Ns Oo , Ns Ar interface Oc Ns ... .Ar ipmp-interface .Xc Remove the IP interface(s) from the IPMP interface. .Bl -tag -width "" .It Fl i Ns \&, Ns Fl -interface Interface(s) to be removed from the IPMP interface. .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm disable-if .Fl t .Ar interface .Xc Disable the specified IP interface. .Bl -tag -width Ds .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm enable-if .Fl t .Ar interface .Xc Enable the specified IP interface. .Bl -tag -width Ds .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm show-if .Op Oo Fl p Oc Fl o Ar field Ns Oo , Ns Ar field Oc Ns ... .Op Ar interface .Xc Show the current IP interface configuration. .Bl -tag -width Ds .It Fl o Ns \&, Ns Fl -output Select which fields will be shown. The field value can be one of the following names: .Bl -tag -compact -width "PERSISTENT" .It Cm ALL Display all fields. .It Cm IFNAME The name of the interface. .It Cm STATE The state can be one of the following values: .Bl -tag -compact -width "disabled" .It Sy ok resources for the interface have been allocated .It Sy offline the interface is offline .It Sy failed the interface's datalink is down .It Sy down the interface is down .It Sy disabled the interface is disabled .El .It Cm CURRENT A set of single character flags indicating the following: .Bl -tag -compact -width "b" .It Sy b broadcast (mutually exclusive with .Sq p ) .It Sy m multicast .It Sy p point-to-point (mutually exclusive with .Sq b ) .It Sy v virtual interface .It Sy I IPMP .It Sy s IPMP standby .It Sy i IPMP inactive .It Sy V VRRP .It Sy a VRRP accept mode .It Sy 4 IPv4 .It Sy 6 IPv6 .El .It Cm PERSISTENT A set of single character flags showing what configuration will be used the next time the interface is enabled: .Bl -tag -compact -width "s" .It Sy s IPMP standby .It Sy 4 IPv4 .It Sy 6 IPv6 .El .El .It Fl p Ns \&, Ns Fl -parsable Print the output in a parsable format. .El .Pp .It Xo .Nm .Cm set-ifprop .Op Fl t .Fl p Ar prop Ns = Ns Ar value Ns Oo , Ns Ar value Oc Ns ... .Fl m Ar protocol .Ar interface .Xc Set a property's value(s) on the specified IP interface. .Bl -tag -width Ds .It Fl m Ns \&, Ns Fl -module Specify which protocol the setting applies to. .It Fl p Ns \&, Ns Fl -prop Specify the property name and value(s). The property name can be one of the following: .Bl -tag -compact -width "exchange_routes" .It Cm arp Address resolution protocol .Pq Cm on Ns / Ns Cm off . .It Cm exchange_routes Exchange of routing data .Pq Cm on Ns / Ns Cm off . .It Cm forwarding IP Forwarding .Pq Cm on Ns / Ns Cm off .It Cm metric Set the routing metric to the numeric value. The value is treated as extra hops to the destination. .It Cm mtu Set the maximum transmission unit to the numeric value. .It Cm nud Neighbor unreachability detection .Pq Cm on Ns / Ns Cm off .It Cm usesrc Indicates which interface to use for source address selection. A value .Cm none may also be used. .El .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm reset-ifprop .Op Fl t .Fl p Ar prop .Fl m Ar protocol .Ar interface .Xc Reset the specified IP interface's property value to the default. .Bl -tag -width Ds .It Fl m Ns \&, Ns Fl -module Specify which protocol the setting applies to. .It Fl p Ns \&, Ns Fl -prop Specify the property name. See the .Nm ipadm Cm set-ifprop subcommand for the list of property names. .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm show-ifprop .Op Oo Fl c Oc Fl o Ar field Ns Oo , Ns Ar value Oc Ns ... .Op Fl p Ar prop Ns Oo , Ns Ar prop Oc Ns ... .Op Fl m Ar protocol .Op Ar interface .Xc Display the property values for one or all of the IP interfaces. .Bl -tag -width Ds .It Fl c Ns \&, Ns Fl -parsable Print the output in a parsable format. .It Fl m Ns \&, Ns Fl -module Specify which protocol to display. .It Fl o Ns \&, Ns Fl -output Select which fields will be shown. The field value can be one of the following names: .Bl -tag -compact -width "PERSISTENT" .It Cm ALL Display all fields. .It Cm IFNAME The name of the interface. .It Cm PROPERTY The name of the property. .It Cm PROTO The name of the protocol. .It Cm PERM If the property is readable .Pq Qq r and/or writable .Pq Qq w . .It Cm CURRENT The value of the property. .It Cm PERSISTENT The persistent value of the property. .It Cm DEFAULT The default value of the property. .It Cm POSSIBLE The possible values for the property. .El .It Fl p Ns \&, Ns Fl -prop Specify which properties to display. See the .Nm ipadm Cm set-ifprop subcommand for the list of property names. .El .Pp .It Xo .Nm .Cm create-addr .Op Fl t .Fl T Cm static .Op Fl d .Fl a Oo Cm local Ns | Ns Cm remote Ns = Oc Ns .Ar addr Ns Oo / Ns Ar prefixlen Oc Ns ... .Ar addrobj .Xc Create an address on the specified IP interface using static configuration. The address will be enabled but can disabled using the .Nm ipadm Cm disable-addr subcommand. Note that .Cm addrconf address configured on the interface is required to configure .Cm static IPv6 address on the same interface. This takes the following options: .Bl -tag -width Ds .It Fl a Ns \&, Ns Fl -address Specify the address. The .Cm local or .Cm remote prefix can be used for a point-to-point interface. In this case, both addresses must be given. Otherwise, the equal sign .Pq Qq = should be omitted and the address should be provided by itself without second address. .It Fl d Ns \&, Ns Fl -down The address is down. .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm create-addr .Op Fl t .Fl T Cm dhcp .Op Fl 1 .Op Fl h Ar hostname .Op Fl w Bro Ar seconds Ns | Ns Cm forever Brc .Ar addrobj .Xc Create an address on the specified IP interface using DHCP. This takes the following options: .Bl -tag -width Ds .It Fl 1 Ns \&, Ns Fl -primary Specify that the interface is primary. One effect will be that .Xr nodename 5 will serve as .Fl h Ns \&, Ns Fl -reqhost if that switch is not otherwise specified. .It Fl h Ns \&, Ns Fl -reqhost Specify the host name to send to the DHCP server in order to request an association of a Fully Qualified Domain Name to the interface. An FQDN is determined from .Ar hostname if it is "rooted" (ending in a '.'), or if it consists of at least three DNS labels, or by appending to .Ar hostname the DNS domain name value configured in .Pa /etc/default/dhcpagent for .Xr dhcpagent 8 . Note that the DHCP server implementation ultimately determines whether and how the client-sent FQDN is used. .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .It Fl w Ns \&, Ns Fl -wait Specify the time, in seconds, that the command should wait to obtain an address; or specify .Cm forever to wait without interruption. The default value is 120. .El .Pp .It Xo .Nm .Cm create-addr .Op Fl t .Fl T Cm addrconf .Op Fl i Ar interface-id .Oo Fl p Bro Cm stateful Ns | Ns Cm stateless Brc Ns = Ns .Bro Cm yes Ns | Ns Cm no Brc Oc Ns ... .Ar addrobj .Xc Create an auto-configured address on the specified IP interface. This takes the following options: .Bl -tag -width Ds .It Fl i Ns \&, Ns Fl -interface-id Specify the interface ID to be used. .It Fl p Ns \&, Ns Fl -prop Specify which method of auto-configuration should be used. .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm delete-addr .Op Fl r .Ar addrobj .Xc Delete the given address. .Bl -tag -width Ds .It Fl r Ns \&, Ns Fl -release Indicate that the DHCP-assigned address should be released. .El .Pp .It Xo .Nm .Cm show-addr .Op Oo Fl p Oc Fl o Ar field Ns Oo , Ns Ar field Oc Ns ... .Op Ar addrobj | interface Ns No / .Xc Show the current address properties; optionally limited to those for the provided .Ar addrobj or for all address objects on the specified .Ar interface . .Bl -tag -width Ds .It Fl o Ns \&, Ns Fl -output Select which fields will be shown. The field value can be one of the following names: .Bl -tag -compact -width "PERSISTENT" .It Cm ALL Display all fields. .It Cm ADDROBJ The name of the address. .It Cm TYPE The type of the address .Pq Sy static Ns / Ns Sy dhcp Ns / Ns Sy addrconf . .It Cm STATE The state of the address. It can be one of the following values: .Bl -tag -compact -width "inaccessible" .It Sy disabled see the .Nm ipadm Cm disable-addr subcommand .It Sy down see the .Nm ipadm Cm down-addr subcommand .It Sy duplicate the address is duplicate .It Sy inaccessible the interface for this address has failed .It Sy ok the address is up .It Sy tentative duplicate address detection in progress .El .It Cm CURRENT A set of single character flags indicating the following: .Bl -tag -compact -width "U" .It Sy U up .It Sy u unnumbered .Pq matches another local address .It Sy p private, not advertised to routing .It Sy t temporary IPv6 address .It Sy d deprecated .Pq not used for outgoing packets .El .It Cm PERSISTENT A set of single character flags showing the configuration which will be used when the address is enabled. .Bl -tag -compact -width "U" .It Sy U up .It Sy p private, not advertised to routing .It Sy d deprecated .Pq not used for outgoing packets .El .It Cm ADDR The address. .El .It Fl p Ns \&, Ns Fl -parsable Print the output in a parsable format. .El .Pp .It Xo .Nm .Cm refresh-addr .Op Fl i .Ar addrobj .Xc Extend the lease for .Sy DHCP addresses. It also restarts duplicate address detection for .Cm static addresses. .Bl -tag -width "" .It Fl i Ns \&, Ns Fl -inform Obtain network configuration from DHCP without taking a lease on the address. .El .Pp .It Xo .Nm .Cm down-addr .Op Fl t .Ar addrobj .Xc Down the address. This will stop packets from being sent or received. .Bl -tag -width Ds .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm up-addr .Op Fl t .Ar addrobj .Xc Up the address. This will enable packets to be sent and received. .Bl -tag -width Ds .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm disable-addr .Op Fl t .Ar addrobj .Xc Disable the address. .Bl -tag -width Ds .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm enable-addr .Op Fl t .Ar addrobj .Xc Enable the address. .Bl -tag -width Ds .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm set-addrprop .Op Fl t .Fl p Ar prop Ns = Ns Ar value Ns Oo , Ns Ar value Oc Ns ... .Ar addrobj .Xc Set a property's value(s) on the specified .Ar addrobj . .Bl -tag -width Ds .It Fl p Ns \&, Ns Fl -prop Specify the property name and value(s). The property name can be one of the following: .Bl -tag -compact -width "deprecated" .It Cm broadcast The broadcast address (read-only). .It Cm deprecated The address should not be used to send packets but can still receive packets .Pq Cm on Ns / Ns Cm off . .It Cm prefixlen The number of bits in the IPv4 netmask or IPv6 prefix. .It Cm primary The DHCP primary interface flag (read-only). .It Cm private The address is not advertised to routing .Pq Cm on Ns / Ns Cm off . .It Cm reqhost The host name to send to the DHCP server in order to request an association of the FQDN to the interface. For a primary DHCP interface, .Xr nodename 5 is sent if this property is not defined. See the .Nm .Cm create-addr .Fl T Cm dhcp subcommand for the explanation of how an FQDN is determined. .It Cm transmit Packets can be transmitted .Pq Cm on Ns / Ns Cm off . .It Cm zone The zone the addrobj is in .Po temporary-only \(em use .Xr zonecfg 8 to make persistent .Pc . .El .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm reset-addrprop .Op Fl t .Fl p Ar prop .Ar addrobj .Xc Reset the .Ar addrobj Ns No 's property value to the default. .Bl -tag -width Ds .It Fl p Ns \&, Ns Fl -prop Specify the property name. See the .Nm ipadm Cm set-addrprop subcommand for the list of property names. .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm show-addrprop .Op Oo Fl c Oc Fl o Ar field Ns Oo , Ns Ar field Oc Ns ... .Op Fl p Ar prop Ns Oo , Ns Ar prop Oc Ns ... .Op Ar addrobj | interface Ns No / .Xc Display property values; optionally limited to those for the provided .Ar addrobj or for all address objects on the specified .Ar interface . .Bl -tag -width Ds .It Fl c Ns \&, Ns Fl -parsable Print the output in a parsable format. .It Fl o Ns \&, Ns Fl -output Select which fields will be shown. The field value can be one of the following names: .Bl -tag -compact -width "PERSISTENT" .It Cm ALL Display all fields. .It Cm ADDROBJ The name of the addrobj. .It Cm PROPERTY The name of the property. .It Cm PERM If the property is readable .Pq Qq r and/or writable .Pq Qq w . .It Cm CURRENT The value of the property. .It Cm PERSISTENT The persistent value of the property. .It Cm DEFAULT The default value of the property. .It Cm POSSIBLE The possible values for the property. .El .It Fl p Ns \&, Ns Fl -prop Specify which properties to display. See the .Nm ipadm Cm set-addrprop subcommand for the list of property names. .El .Pp .It Xo .Nm .Cm set-prop .Op Fl t .Fl p Ar prop Ns Oo Cm + Ns | Ns Cm - Oc Ns = Ns .Ar value Ns Oo , Ns Ar value Oc Ns ... .Ar protocol .Xc Set a property's value(s) on the protocol. .Bl -tag -width Ds .It Fl p Ns \&, Ns Fl -prop Specify the property name and value(s). The optional .Sy + Ns | Ns Sy - syntax can be used to add/remove values from the current list of values on the property. The property name can be one of the following: .Bl -tag -compact -width "smallest_nonpriv_port" .It Cm congestion_control The default congestion-control algorithm to be used for new connections .Pq TCP . .It Cm ecn Explicit congestion control .Pq Cm never Ns / Ns Cm passive Ns / Ns Cm active .Pq TCP . .It Cm extra_priv_ports Additional privileged ports .Pq SCTP/TCP/UDP . .It Cm forwarding Packet forwarding .Pq Cm on Ns / Ns Cm off . .It Cm hoplimit The IPv6 hoplimit. .It Cm hostmodel IP packet handling on multi-homed systems .Pq Cm weak Ns / Ns Cm strong Ns / Ns Cm src-priority .Pq IPv4/IPv6 . .Cm weak and .Cm strong correspond to the model definitions defined in RFC 1122. .Cm src-priority is a hybrid mode where outbound packets are sent from the interface with the packet's source address if possible. .It Cm largest_anon_port Largest ephemeral port .Pq SCTP/TCP/UDP . .It Cm max_buf Maximum receive or send buffer size .Pq ICMP/SCTP/TCP/UDP . This also sets the upper limit for the .Cm recv_buf and .Cm send_buf properties. .It Cm recv_buf Default receive buffer size .Pq ICMP/SCTP/TCP/UDP . The maximum value for this property is controlled by the .Cm max_buf property. .It Cm sack Selective acknowledgement .Pq Cm active Ns / Ns Cm passive Ns / Ns Cm never .Pq TCP . .It Cm send_buf Default send buffer size .Pq ICMP/SCTP/TCP/UDP . The maximum value for this property is controlled by the .Cm max_buf property. .It Cm smallest_anon_port Smallest ephemeral port .Pq SCTP/TCP/UDP . .It Cm smallest_nonpriv_port Smallest non-privileged port .Pq SCTP/TCP/UDP . .It Cm ttl The IPv4 time-to-live. .El .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm reset-prop .Op Fl t .Fl p Ar prop .Ar protocol .Xc Reset a protocol's property value to the default. .Bl -tag -width Ds .It Fl p Ns \&, Ns Fl -prop Specify the property name. See the .Nm ipadm Cm set-prop subcommand for the list of property names. .It Fl t Ns \&, Ns Fl -temporary Temporary, not persistent across reboots. .El .Pp .It Xo .Nm .Cm show-prop .Op Oo Fl c Oc Fl o Ar field Ns Oo , Ns Ar field Oc Ns ... .Op Fl p Ar prop Ns Oo , Ns Ar prop Oc Ns ... .Op Ar protocol .Xc Display the property values for one or all of the protocols. .Bl -tag -width Ds .It Fl c Ns \&, Ns Fl -parsable Print the output in a parsable format. .It Fl o Ns \&, Ns Fl -output Select which fields will be shown. The field value can be one of the following names: .Bl -tag -compact -width "PERSISTENT" .It Cm ALL Display all fields. .It Cm PROTO The name of the protocol. .It Cm PROPERTY The name of the property. .It Cm PERM If the property is readable .Pq Qq r and/or writable .Pq Qq w . .It Cm CURRENT The value of the property. .It Cm PERSISTENT The persistent value of the property. .It Cm DEFAULT The default value of the property. .It Cm POSSIBLE The possible values for the property. .El .It Fl p Ns \&, Ns Fl -prop Specify which properties to display. See the .Nm ipadm Cm set-prop subcommand for the list of property names. .El .El .Sh SEE ALSO .Xr nodename 5 , .Xr nsswitch.conf 5 , .Xr dhcp 7 , .Xr arp 8 , .Xr cfgadm 8 , .Xr dhcpagent 8 , .Xr dladm 8 , .Xr if_mpadm 8 , .Xr ifconfig 8 , .Xr ndd 8 , .Xr zonecfg 8