'\" te .\" Copyright (c) 2007, Sun Microsystems, Inc. All Rights Reserved .\" Copyright 2019 Joyent, Inc. .\" The contents of this file are subject to the terms of the Common Development and Distribution License (the "License"). You may not use this file except in compliance with the License. .\" You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE or http://www.opensolaris.org/os/licensing. See the License for the specific language governing permissions and limitations under the License. .\" When distributing Covered Code, include this CDDL HEADER in each file and include the License file at usr/src/OPENSOLARIS.LICENSE. If applicable, add the following below this CDDL HEADER, with the fields enclosed by brackets "[]" replaced with your own identifying information: Portions Copyright [yyyy] [name of copyright owner] .TH SVCPROP 1 "Dec 11, 2019" .SH NAME svcprop \- retrieve values of service configuration properties .SH SYNOPSIS .nf \fBsvcprop\fR [\fB-fqtv\fR] [\fB-C\fR | \fB-c\fR | \fB-s\fR \fIsnapshot\fR] [\fB-z\fR \fIzone\fR] [\fB-p\fR [\fIname\fR/]\fIname\fR]... {\fIFMRI\fR | \fIpattern\fR}... .fi .LP .nf \fBsvcprop\fR \fB-w\fR [\fB-fqtv\fR] [\fB-z\fR \fIzone\fR] [\fB-p\fR [\fIname\fR/]\fIname\fR] {\fIFMRI\fR | \fIpattern\fR} .fi .SH DESCRIPTION The \fBsvcprop\fR utility prints values of properties in the service configuration repository. Properties are selected by \fB-p\fR options and the operands. .sp .LP Without the \fB-C\fR, \fB-c\fR, or \fB-s\fR options, \fBsvcprop\fR accesses effective properties. The effective properties of a service are its directly attached properties. The effective properties of a service instance are the union of properties in the composed view of its \fBrunning\fR snapshot and the properties in nonpersistent property groups in the composed view of the instance's directly attached properties. See \fBsmf\fR(5) for an explanation of property composition. If the \fBrunning\fR snapshot does not exist then the instance's directly attached properties are used instead. .SS "Output Format" By default, when a single property is selected, the values for each are printed on separate lines. Empty \fBASCII\fR string values are represented by a pair of double quotes (\fB""\fR). Bourne shell metacharacters ('\fB;\fR', '\fB&\fR\&', \&'\fB(\fR', '\fB)\fR', '\fB|\fR', '\fB^\fR', '\fB<\fR\&', '\fB>\fR', newline, space, tab, backslash, '\fB"\fR', single-quote, '\fB`\fR') in \fBASCII\fR string values are quoted by backslashes (\fB\e\fR). .sp .LP When multiple properties are selected, a single line is printed for each. Each line comprises a property designator, a property type, and the values (as described above), separated by spaces. By default, if a single \fIFMRI\fR operand has been supplied, the property designator consists of the property group name and the property name joined by a slash (\fB/\fR). If multiple \fIFMRI\fR operands are supplied, the designator is the canonical \fIFMRI\fR for the property. .sp .LP If access controls prohibit reading the value of a property, and no property or property group is specified explicitly by a \fB-p\fR option, the property is displayed as if it had no values. If one or more property or property group names is specified by a \fB-p\fR option, and any property value cannot be read due to access controls, an error results. .sp .LP Error messages are printed to the standard error stream. .SH OPTIONS The following options are supported: .sp .ne 2 .na \fB\fB-C\fR\fR .ad .RS 14n Uses the directly attached properties, without composition. .RE .sp .ne 2 .na \fB\fB-c\fR\fR .ad .RS 14n For service instances, uses the composed view of their directly attached properties. .RE .sp .ne 2 .na \fB\fB-f\fR\fR .ad .RS 14n Selects the multi-property output format, with full FMRIs as designators. .RE .sp .ne 2 .na \fB\fB-p\fR \fIname\fR\fR .ad .RS 14n For each service or service instance specified by the operands, selects all properties in the \fIname\fR property group. For property groups specified by the operands, selects the \fIname\fR property. .RE .sp .ne 2 .na \fB\fB-p\fR \fIpg\fR/\fIprop\fR\fR .ad .RS 14n Selects property \fIprop\fR in property group \fIpg\fR for each of the services or service instances specified by the operands. .RE .sp .ne 2 .na \fB\fB-q\fR\fR .ad .RS 14n Quiet. Produces no output. .RE .sp .ne 2 .na \fB\fB-s\fR \fIname\fR\fR .ad .RS 14n Uses the composed view of the \fIname\fR snapshot for service instances. .RE .sp .ne 2 .na \fB\fB-t\fR\fR .ad .RS 14n Selects the multi-property output format. .RE .sp .ne 2 .na \fB\fB-v\fR\fR .ad .RS 14n Verbose. Prints error messages for nonexistent properties, even if option -q is also used. .RE .sp .ne 2 .na \fB\fB-w\fR\fR .ad .RS 14n Waits until the specified property group or the property group containing the specified property changes before printing. .sp This option is only valid when a single entity is specified. If more than one operand is specified, or an operand matches more than one instance, an error message is printed and no action is taken. The -C option is implied. .RE .sp .ne 2 .na \fB-z\fR \fIzone\fR .ad .RS 14n Uses properties from the service or instance in the specified \fIzone\fR. This option is only applicable from the global zone, see \fBzones\fR(5). .SH OPERANDS The following operands are supported: .sp .ne 2 .na \fB\fIFMRI\fR\fR .ad .RS 11n The FMRI of a service, a service instance, a property group, or a property. .sp Instances and services can be abbreviated by specifying the instance name, or the trailing portion of the service name. Properties and property groups must be specified by a full FMRI. For example, given the FMRI: .sp .in +2 .nf svc:/network/smtp:sendmail .fi .in -2 .sp The following are valid abbreviations: .sp .in +2 .nf sendmail :sendmail smtp smtp:sendmail network/smtp .fi .in -2 .sp The following are invalid abbreviations: .sp .in +2 .nf mail network network/smt .fi .in -2 .sp Abbreviated forms of FMRIs are unstable and should not be used in scripts or other permanent tools. If an abbreviation matches multiple instances, \fBsvcprop\fR acts on each instance. .RE .sp .ne 2 .na \fBpattern\fR .ad .RS 11n A glob pattern which is matched against the FMRIs of services and instances in the repository. See \fBfnmatch\fR(5). If a pattern matches multiple services or instances, \fBsvcprop\fR acts on each service or instance. .RE .SH EXAMPLES \fBExample 1 \fRDisplaying the Value of a Single Property .sp .LP The following example displays the value of the state property in the restarter property group of instance \fBdefault\fR of service \fBsystem/cron\fR. .sp .in +2 .nf example% svcprop -p restarter/state system/cron:default online .fi .in -2 .sp .LP \fBExample 2 \fRRetrieving Whether a Service is Enabled .sp .LP Whether a service is enabled is determined by its \fB-general/enabled\fR property. This property takes immediate effect, so the \fB-c\fR option must be used: .sp .in +2 .nf example% svcprop -c -p general/enabled system/cron:default true .fi .in -2 .sp .LP \fBExample 3 \fRDisplaying All Properties in a Property Group .sp .LP On a default installation of Solaris, the following example displays all properties in the \fBgeneral\fR property group of each instance of the \fBnetwork/ntp\fR service: .sp .in +2 .nf example% svcprop -p general ntp general/package astring SUNWntpr general/enabled boolean true general/entity_stability astring Unstable .fi .in -2 .sp .LP \fBExample 4 \fRTesting the Existence of a Property .sp .LP The following example tests the existence of the \fBgeneral/enabled\fR property for all instances of service identity: .sp .in +2 .nf example% svcprop -q -p general/enabled identity: example% echo $? 0 .fi .in -2 .sp .LP \fBExample 5 \fRWaiting for Property Change .sp .LP The following example waits for the \fBsendmail\fR instance to change state. .sp .in +2 .nf example% svcprop -w -p restarter/state sendmail .fi .in -2 .sp .LP \fBExample 6 \fRRetrieving the Value of a Boolean Property in a Script .sp .LP The following example retrieves the value of a boolean property in a script: .sp .in +2 .nf set -- `svcprop -c -t -p general/enabled service` code=$? if [ $code -ne 0 ]; then echo "svcprop failed with exit code $code" return 1 fi if [ $2 != boolean ]; then echo "general/enabled has unexpected type $2" return 2 fi if [ $# -ne 3 ]; then echo "general/enabled has wrong number of values" return 3 fi value=$3 \&... .fi .in -2 .sp .LP \fBExample 7 \fRUsing \fBsvcprop\fR in a Script .sp .in +2 .nf example% cat getval #!/bin/sh svcprop -p $1 $2 | ( read value v2 if [ -n "$v2" ]; then echo "Multiple values!"; exit; fi echo $value ) .fi .in -2 .sp .SH EXIT STATUS The following exit values are returned: .sp .ne 2 .na \fB\fB0\fR\fR .ad .RS 5n Successful completion. .RE .sp .ne 2 .na \fB\fB1\fR\fR .ad .RS 5n An error occurred. .RE .sp .ne 2 .na \fB\fB2\fR\fR .ad .RS 5n Invalid command line options were specified. .RE .SH SEE ALSO \fBsvcs\fR(1), \fBinetd\fR(1M), \fBsvcadm\fR(1M), \fBsvccfg\fR(1M), \fBsvc.startd\fR(1M), \fBservice_bundle\fR(4), \fBattributes\fR(5), \fBfnmatch\fR(5), \fBsmf\fR(5), \fBsmf_method\fR(5), \fBsmf_security\fR(5), \fBzones\fR(5)