# # Copyright (c) 2010, Oracle and/or its affiliates. All rights reserved. # # CDDL HEADER START # # The contents of this file are subject to the terms of the # Common Development and Distribution License (the "License"). # You may not use this file except in compliance with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. # See the License for the specific language governing permissions # and limitations under the License. # # When distributing Covered Code, include this CDDL HEADER in each # file and include the License file at usr/src/OPENSOLARIS.LICENSE. # If applicable, add the following below this CDDL HEADER, with the # fields enclosed by brackets "[]" replaced with your own identifying # information: Portions Copyright [yyyy] [name of copyright owner] # # CDDL HEADER END # # DO NOT EDIT -- this file is generated by the Event Registry. # # # code: STORAGE-8000-1Q # keys: fault.config.fan-fail # msgid "STORAGE-8000-1Q.type" msgstr "Fault" msgid "STORAGE-8000-1Q.severity" msgstr "Critical" msgid "STORAGE-8000-1Q.description" msgstr "The minimum number of required chassis fans '%' were not detected. The missing devices are '%'." msgid "STORAGE-8000-1Q.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-1Q.impact" msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved." msgid "STORAGE-8000-1Q.action" msgstr "Check that the minimum required number of fans are configured." # # code: STORAGE-8000-24 # keys: fault.config.fantray-fail # msgid "STORAGE-8000-24.type" msgstr "Fault" msgid "STORAGE-8000-24.severity" msgstr "Critical" msgid "STORAGE-8000-24.description" msgstr "The minimum number of required chassis fan trays '%' were not detected. The missing devices are '%'." msgid "STORAGE-8000-24.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-24.impact" msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved." msgid "STORAGE-8000-24.action" msgstr "Check that the minimum required number of fan trays are configured." # # code: STORAGE-8000-3R # keys: fault.config.psu-fail # msgid "STORAGE-8000-3R.type" msgstr "Fault" msgid "STORAGE-8000-3R.severity" msgstr "Critical" msgid "STORAGE-8000-3R.description" msgstr "The minimum number of required chassis power supplies '%' were not detected. The missing devices are '%'." msgid "STORAGE-8000-3R.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-3R.impact" msgstr "The SAS fabric is down, and user data storage is unavailable until the configuration problem is resolved." msgid "STORAGE-8000-3R.action" msgstr "Check that the minimum required number of power supplies are configured." # # code: STORAGE-8000-42 # keys: fault.device.controller.fail # msgid "STORAGE-8000-42.type" msgstr "Fault" msgid "STORAGE-8000-42.severity" msgstr "Major" msgid "STORAGE-8000-42.description" msgstr "Controller card '%' is not functioning correctly." msgid "STORAGE-8000-42.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-42.impact" msgstr "The SAS fabric may be in a degraded state." msgid "STORAGE-8000-42.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-5X # keys: fault.device.ethernet.fail # msgid "STORAGE-8000-5X.type" msgstr "Fault" msgid "STORAGE-8000-5X.severity" msgstr "Major" msgid "STORAGE-8000-5X.description" msgstr "An out-of-band management interface failure has occurred on '%'." msgid "STORAGE-8000-5X.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-5X.impact" msgstr "The SAS fabric may be in a degraded state. User data storage is still available." msgid "STORAGE-8000-5X.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-6E # keys: fault.device.fan.fail # msgid "STORAGE-8000-6E.type" msgstr "Fault" msgid "STORAGE-8000-6E.severity" msgstr "Major" msgid "STORAGE-8000-6E.description" msgstr "A fan on '%' is not functioning correctly." msgid "STORAGE-8000-6E.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-6E.impact" msgstr "The chassis may be getting inadequate cooling. If the problem persists, components may overheat and the chassis may shutdown." msgid "STORAGE-8000-6E.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-7J # keys: fault.device.psu.fail # msgid "STORAGE-8000-7J.type" msgstr "Fault" msgid "STORAGE-8000-7J.severity" msgstr "Major" msgid "STORAGE-8000-7J.description" msgstr "Power supply '%' is not functioning correctly." msgid "STORAGE-8000-7J.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-7J.impact" msgstr "The chassis may not be getting adequate power. Subsequent loss of power supplies may cause the chassis to shutdown." msgid "STORAGE-8000-7J.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-8S # keys: fault.device.sas-expander.fail # msgid "STORAGE-8000-8S.type" msgstr "Fault" msgid "STORAGE-8000-8S.severity" msgstr "Major" msgid "STORAGE-8000-8S.description" msgstr "A SAS expander on '%' is not functioning correctly." msgid "STORAGE-8000-8S.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-8S.impact" msgstr "The SAS fabric is in a degraded state. User data storage may be degraded or unavailable." msgid "STORAGE-8000-8S.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-95 # keys: fault.device.unusable-chassis-id # msgid "STORAGE-8000-95.type" msgstr "Fault" msgid "STORAGE-8000-95.severity" msgstr "Critical" msgid "STORAGE-8000-95.description" msgstr "The chassis ID was determined to be unusable." msgid "STORAGE-8000-95.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-95.impact" msgstr "The SAS fabric is down, and user data storage is unavailable." msgid "STORAGE-8000-95.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-AP # keys: fault.io.i2c.fail # msgid "STORAGE-8000-AP.type" msgstr "Fault" msgid "STORAGE-8000-AP.severity" msgstr "Critical" msgid "STORAGE-8000-AP.description" msgstr "An I2C bus on '%' is not functioning correctly." msgid "STORAGE-8000-AP.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-AP.impact" msgstr "The system is in an unknown state." msgid "STORAGE-8000-AP.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-CA # keys: fault.io.sas.log.fatal # msgid "STORAGE-8000-CA.type" msgstr "Fault" msgid "STORAGE-8000-CA.severity" msgstr "Critical" msgid "STORAGE-8000-CA.description" msgstr "A fatal error has been detected by a SAS expander on '%' requiring it to reset." msgid "STORAGE-8000-CA.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-CA.impact" msgstr "The SAS expander is not functioning correctly. The SAS fabric will be in a degraded state while the expander resets. Downstream devices may be inaccessible." msgid "STORAGE-8000-CA.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-DH # keys: fault.io.sas.log.non-fatal # msgid "STORAGE-8000-DH.type" msgstr "Fault" msgid "STORAGE-8000-DH.severity" msgstr "Major" msgid "STORAGE-8000-DH.description" msgstr "A non-fatal error has been detected by a SAS expander on '%'." msgid "STORAGE-8000-DH.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-DH.impact" msgstr "The SAS expander may not be functioning correctly. The SAS fabric may be in a degraded state. Downstream devices may be inaccessible." msgid "STORAGE-8000-DH.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-ED # keys: fault.power.ext-fail # msgid "STORAGE-8000-ED.type" msgstr "Fault" msgid "STORAGE-8000-ED.severity" msgstr "Major" msgid "STORAGE-8000-ED.description" msgstr "A power failure external to the chassis has occurred." msgid "STORAGE-8000-ED.response" msgstr "None." msgid "STORAGE-8000-ED.impact" msgstr "The chassis may not be getting adequate power. Subsequent loss of power supplies may cause the chassis to shutdown." msgid "STORAGE-8000-ED.action" msgstr "Check that external AC power is available and that all the power cords are plugged into the chassis power supplies." # # code: STORAGE-8000-FY # keys: fault.power.fail # msgid "STORAGE-8000-FY.type" msgstr "Fault" msgid "STORAGE-8000-FY.severity" msgstr "Major" msgid "STORAGE-8000-FY.description" msgstr "A power failure has occurred on '%'." msgid "STORAGE-8000-FY.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-FY.impact" msgstr "A device in the chassis may be getting inadequate power. Subsequent loss of the device may force the chassis to shutdown." msgid "STORAGE-8000-FY.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-G3 # keys: fault.sensor.read-fail # msgid "STORAGE-8000-G3.type" msgstr "Fault" msgid "STORAGE-8000-G3.severity" msgstr "Major" msgid "STORAGE-8000-G3.description" msgstr "An attempt to read a sensor on '%' failed." msgid "STORAGE-8000-G3.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-G3.impact" msgstr "Data from the affected sensor will be unavailable. Data from other sensors may be used instead if available." msgid "STORAGE-8000-G3.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-HR # keys: fault.sp.fail # msgid "STORAGE-8000-HR.type" msgstr "Fault" msgid "STORAGE-8000-HR.severity" msgstr "Critical" msgid "STORAGE-8000-HR.description" msgstr "A Service Processor on '%' is not functioning correctly." msgid "STORAGE-8000-HR.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-HR.impact" msgstr "The SAS fabric may be in a degraded state." msgid "STORAGE-8000-HR.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-J4 # keys: fault.sp.unavailable # msgid "STORAGE-8000-J4.type" msgstr "Fault" msgid "STORAGE-8000-J4.severity" msgstr "Major" msgid "STORAGE-8000-J4.description" msgstr "A Service Processor has detected that its peer is unavailable." msgid "STORAGE-8000-J4.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-J4.impact" msgstr "IMP_FAB_MB_DEG" msgid "STORAGE-8000-J4.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-KQ # keys: fault.sp.svc-fail # msgid "STORAGE-8000-KQ.type" msgstr "Fault" msgid "STORAGE-8000-KQ.severity" msgstr "Major" msgid "STORAGE-8000-KQ.description" msgstr "A Service Processor software service failure has occurred on '%'. The service which restarted was '%'." msgid "STORAGE-8000-KQ.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-KQ.impact" msgstr "The SAS fabric may be in a degraded state. User data storage is still available." msgid "STORAGE-8000-KQ.action" msgstr "Refer to the Maintenance page in the Sun ZFS Storage UI to identify the failed component. If a repair is required, the repair instructions are located in the help section of the Sun ZFS Storage UI." # # code: STORAGE-8000-LC # keys: fault.temp.fail # msgid "STORAGE-8000-LC.type" msgstr "Fault" msgid "STORAGE-8000-LC.severity" msgstr "Major" msgid "STORAGE-8000-LC.description" msgstr "Ambient temperature is outside of normal operating range." msgid "STORAGE-8000-LC.response" msgstr "The service required LED on the chassis will be illuminated." msgid "STORAGE-8000-LC.impact" msgstr "A device in the chassis may be overheating. Subsequent loss of the device may force the chassis to shutdown." msgid "STORAGE-8000-LC.action" msgstr "Check that the ambient temperature is adequately cool, and none of the chassis air inlets are blocked."