# # Copyright 2008 Sun Microsystems, Inc. All rights reserved. # Use is subject to license terms. # # CDDL HEADER START # # The contents of this file are subject to the terms of the # Common Development and Distribution License (the "License"). # You may not use this file except in compliance with the License. # # You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE # or http://www.opensolaris.org/os/licensing. # See the License for the specific language governing permissions # and limitations under the License. # # When distributing Covered Code, include this CDDL HEADER in each # file and include the License file at usr/src/OPENSOLARIS.LICENSE. # If applicable, add the following below this CDDL HEADER, with the # fields enclosed by brackets "[]" replaced with your own identifying # information: Portions Copyright [yyyy] [name of copyright owner] # # CDDL HEADER END # # # DO NOT EDIT -- this file is generated by the Event Registry. # # # code: DISK-8000-0X # keys: fault.io.disk.predictive-failure # msgid "DISK-8000-0X.type" msgstr "Fault" msgid "DISK-8000-0X.severity" msgstr "Major" msgid "DISK-8000-0X.description" msgstr "SMART health-monitoring firmware reported that a disk\nfailure is imminent.\n Refer to %s for more information." msgid "DISK-8000-0X.response" msgstr "None.\n" msgid "DISK-8000-0X.impact" msgstr "It is likely that the continued operation of\nthis disk will result in data loss.\n" msgid "DISK-8000-0X.action" msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u to identify the disk.\n" # # code: DISK-8000-12 # keys: fault.io.disk.over-temperature # msgid "DISK-8000-12.type" msgstr "Fault" msgid "DISK-8000-12.severity" msgstr "Major" msgid "DISK-8000-12.description" msgstr "A disk's temperature exceeded the limits established by\nits manufacturer.\n Refer to %s for more information." msgid "DISK-8000-12.response" msgstr "None.\n" msgid "DISK-8000-12.impact" msgstr "Performance degradation is likely and continued disk operation\nbeyond the temperature threshold can result in disk\ndamage and potential data loss.\n" msgid "DISK-8000-12.action" msgstr "Ensure that the system is properly cooled, that all fans are\nfunctional, and that there are no obstructions of airflow to the affected\ndisk.\n" # # code: DISK-8000-2J # keys: fault.io.disk.self-test-failure # msgid "DISK-8000-2J.type" msgstr "Fault" msgid "DISK-8000-2J.severity" msgstr "Critical" msgid "DISK-8000-2J.description" msgstr "One or more disk self tests failed.\n Refer to %s for more information." msgid "DISK-8000-2J.response" msgstr "None.\n" msgid "DISK-8000-2J.impact" msgstr "The disk has failed.\n" msgid "DISK-8000-2J.action" msgstr "Schedule a repair procedure to replace the affected disk.\nUse fmdump -v -u to identify the disk.\n" # # code: DISK-8000-3E # keys: fault.io.scsi.cmd.disk.dev.rqs.derr # msgid "DISK-8000-3E.type" msgstr "Fault" msgid "DISK-8000-3E.severity" msgstr "Critical" msgid "DISK-8000-3E.description" msgstr "A non-recoverable hardware failure was detected by the device while performing a command.\n Refer to %s for more information." msgid "DISK-8000-3E.response" msgstr "The device may be offlined or degraded.\n" msgid "DISK-8000-3E.impact" msgstr "The device has failed. The service may have been lost or degraded.\n" msgid "DISK-8000-3E.action" msgstr "Ensure that the latest drivers and patches are installed. Schedule a repair procedure to replace the affected\ndevice. Use 'fmadm faulty' to find the affected disk.\n" # # code: DISK-8000-4Q # keys: fault.io.scsi.cmd.disk.dev.rqs.merr # msgid "DISK-8000-4Q.type" msgstr "Fault" msgid "DISK-8000-4Q.severity" msgstr "Critical" msgid "DISK-8000-4Q.description" msgstr "The command was terminated with a non-recovered error condition that may have been caused by a flaw in the media or an error in the recorded data. \n Refer to %s for more information." msgid "DISK-8000-4Q.response" msgstr "The device may be offlined or degraded.\n" msgid "DISK-8000-4Q.impact" msgstr "It is likely that continued operation will result in data corruption, which may eventually cause the loss of service or the service degradation.\n" msgid "DISK-8000-4Q.action" msgstr "Schedule a repair procedure to replace the affected device. Use 'fmadm faulty' to find the affected disk.\n"